HomeMy WebLinkAboutB16-0330_S1_1478903980.pdf7. GENERAL A. ENGINEER'S ACCEPTANCE SHALL BE SECURED FOR ALL STRUCTURAL SUBSTITUTIONS. B. VERIFY ALL OPENINGS THROUGH FLOORS, WALLS AND ROOFS WITH MECHANICAL AND ELECTRICAL CONTRACTORS. VERIFICATION OF LOCATIONS, SIZES, LINTELS AND CONNECTIONS ARE CONTRACTOR'S COMPLETE RESPONSIBILITY. C. ENGINEER'S APPROVAL OF CONNECTIONS AND SUPPORTS SHALL BE OBTAINED PRIOR TO ATTACHING MECHANICAL AND ELECTRICAL ITEMS TO THE STRUCTURE. RESPECTIVE SUB-CONTRACTORS SHALL FURNISH ALL HANGERS, CONNECTIONS, ETC. REQUIRED FOR INSTALLATION OF THEIR ITEMS. D. WATERPROOFING, VAPOR BARRIERS, WATER-STOP, ETC. SHALL BE AS SHOWN ON THE ARCHITECTURAL DRAWINGS AND AS INDICATED IN THE SPECIFICATIONS. E. ALL MASONRY AND STONE VENEERS SHALL BE ATTACHED TO EXTERIOR WALLS AS SPECIFIED IN SECTION 1405 OF THE INTERNATIONAL BUILDING CODE. F. ALL DIMENSIONS ON STRUCTURAL DRAWINGS SHALL BE CHECKED AGAINST EXISTING FIELD CONDITIONS AND/OR ARCHITECTURAL DRAWINGS. DO NOT SCALE DRAWINGS. PROJECT: 327 ROCKLEDGE ROAD LANDSCAPE WALLS, VAIL, COLORADO G3 # 1630 DATE: APRIL 4, 2016 1. LIVE LOADS USED IN DESIGN: A. PATIO: 100 psf B. IMPORTANCE FACTORS DESIGN CATEGORY: B SEISMIC FACTOR (IE): 1.0 SNOW FACTOR (IS): 1.0 WIND FACTOR (IW): 1.0 C. WIND (Vult) 115 MPH (Vasd) 89.1 MPH WIND FACTOR: 1.0 D. SNOW GROUND SNOW LOAD (Pg): 100 PSF FLAT ROOF SNOW LOAD (Pf): 100 PSF EXPOSURE FACTOR (Ce): 1.0 THERMAL FACTOR (Ct): 1.0 E. SEISMIC: SITE CLASS: D DESIGN CATEGORY: B SS 0.35 S1: 0.07 SDS: 0.35 SD1: 0.111 SEISMIC RESPONSE COEFFICIENT (Cs): 0.07 RESPONSE MODIFICATION FACTOR (R): 6 ANALYSIS PROCEDURE: SIMPLIFIED METHOD F. BUILDING CODE USED IN DESIGN: 2012 IRC 2. TESTING, INSPECTIONS AND OBSERVATIONS: A. PERIODIC OBSERVATIONS OF CONSTRUCTION BY THE STRUCTURAL ENGINEER SHALL NOT REPLACE REQUIRED INSPECTIONS BY THE GOVERNING AUTHORITY OR SERVE AS "SPECIAL INSPECTIONS" AS MAY BE REQUIRED BY CHAPTER 17 OF THE INTERNATIONAL BUILDING CODE. 3. FOUNDATIONS A. MAXIMUM ALLOWABLE SOIL BEARING PRESSURE USED IN DESIGN: 2000 psf. B. THE CONTRACTOR SHALL RETAIN A STATE LICENSED SOILS ENGINEER TO REVIEW THE SUB-GRADE AND PROVIDE WRITTEN DOCUMENTATION THAT THE SOIL BEARING CAPACITY IS EQUAL OR GREATER THAN INDICATED ABOVE. C. ALL FOOTING BEARING ELEVATIONS SHOWN ON THE CONSTRUCTION DOCUMENTS ARE ASSUMED TO BEAR ON UNDISTURBED NATURAL SOIL. ACTUAL FIELD CONDITIONS SHALL BE VERIFIED BY THE CONTRACTOR AND APPROVED BY THE SOILS ENGINEER PRIOR TO PLACING CONCRETE. THE BOTTOM OF ALL FOOTINGS SHALL BE A MINIMUM OF 3'-6" BELOW GRADE. D. CONTRACTOR SHALL BACKFILL EQUALLY ON EACH SIDE OF FOUNDATION WALLS IN 12" MAXIMUM VERTICAL LIFTS OR AS RECOMMENDED IN THE PROJECT SOILS REPORT. REFER TO SOILS REPORT FOR BACKFILL MATERIAL. E. CENTER ALL FOOTINGS UNDER WALLS, COLUMNS OR GRIDS UNLESS NOTED OTHERWISE ON PLANS. F. CONTRACTOR SHALL NOTIFY SOILS ENGINEER AFTER EXCAVATION IS COMPLETE SO THAT CONDITIONS MAY BE REVIEWED PRIOR TO PLACEMENT OF ANY FILL OR CONCRETE. 4. SLAB ON GRADE D. THE PREPARATION OF THE SUB-GRADE FOR THE SLAB ON GRADE SHALL BE PERFORMED IN STRICT ACCORDANCE WITH THE PROJECT SOILS REPORT RECOMMENDATIONS. CONTRACTOR SHALL DIRECT ALL QUESTIONS REGARDING SUB-GRADE PREPARATION TO THE GEOTECHNICAL ENGINEER. E. MOVEMENT OF THE SLAB ON GRADE MAY CAUSE DAMAGE TO ANYTHING CONNECTED TO BOTH THE SLAB AND TO OTHER PORTIONS OF THE STRUCTURE. ISOLATION DETAILS FOR NON-BEARING PARTITIONS, BASEBOARDS, PIPING AND OTHER SENSITIVE ITEMS MAY BE REQUIRED. REFER TO THE APPROPRIATE DRAWINGS AND/OR CONSULT WITH THE RESPONSIBLE MEMBER OF THE DESIGN TEAM PRIOR TO CONNECTING ITEMS TO BOTH THE SLAB ON GRADE AND OTHER PORTIONS OF THE STRUCTURE. PROVIDE FRACTURE MEMBRANE BETWEEN SLABS AND ANY BRITTLE SLAB FINISHES (STONE OR TILE). 5. CONCRETE A. ALL CAST-IN-PLACE CONCRETE SHALL BE MADE WITH TYPE I/II PORTLAND CEMENT, STONE AGGREGATE, AND SHALL SATISFY THE FOLLOWING REQUIREMENTS: CONCRETE ITEM F'c MIX TYPE MAX. W/C RATIO % AIR FOOTINGS 3000 psi STD. N/A N/A FOUNDATION WALLS 3000 psi STD N/A N/A EXTERIOR CONCRETE SLABS 4500 psi STD 0.45 6% - 8% (MAXIMUM SLUMP FOR EXTERIOR CONCRETE SHALL NOT EXCEED 4") B. CONTRACTOR SHALL SAW-CUT OR TROWEL CUT JOINTS IN SLABS ON GRADE AND IN TOPPING SLABS WHERE INDICATED ON PLAN. UNLESS NOTED OTHERWISE, JOINTS SHALL BE SPACED AT 12'-0" MAXIMUM IN EACH DIRECTION AND CUT 1/4 OF THE SLAB DEPTH X 3/16" WIDE WITHIN 12 HOURS AFTER PLACEMENT. ALL SLAB REINFORCEMENT SHALL BE CONTINUOUS THROUGH CONTROL JOINTS. C. ALL SLABS, TOPPINGS, FOOTINGS AND WALLS SHALL NOT HAVE JOINTS IN A HORIZONTAL PLANE. ANY STOP IN CONCRETE WORK SHALL BE MADE WITH VERTICAL BULKHEADS AND HORIZONTAL SHEAR KEYS UNLESS NOTED OTHERWISE. PROVIDE CONSTRUCTION JOINT LOCATIONS FOR REVIEW BY THE STRUCTURAL ENGINEER PRIOR TO PLACING CONCRETE. D. ALL CONCRETE WORK AND REINFORCEMENT DETAILING SHALL BE IN ACCORDANCE WITH ACI-318, LATEST EDITION, UNLESS NOTED OTHERWISE. USE STANDARD HOOKS FOR ALL FOOTING DOWELS UNLESS NOTED OTHERWISE. PROVIDE 3/4" CHAMFER AT ALL PERMANENTLY EXPOSED EDGES OF CONCRETE UNLESS NOTED OTHERWISE. 6. REINFORCEMENT A. ALL REINFORCING SHALL BE HIGH-STRENGTH DEFORMED BARS CONFORMING TO ASTM A615, GRADE 60 EXCEPT TIES, STURRUPS AND PLATE ANCHORS WHICH SHALL BE ASTM, A615, GRADE 40 OR ASTM A706, GRADE 60. B. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A 185, GRADE 65 AND SHALL BE LAPPED ONE FULL MESH AND BE SECURELY WIRED TOGETHER AT SPLICES. C. MINIMUM CONCRETE COVER FOR REINFORCEMENT C1. CONCRETE CAST AGAINST EARTH 3" C2. CONCRETE CAST IN FORMS (EXPOSED TO EARTH/WEATHER) 2" D. REINFORCEMENT PLACEMENT AND TOLERANCES SHALL BE IN ACCORDANCE WITH ACI-318 LATEST EDITION. ALL REINFORCING SHALL BE ACCURATELY LOCATED, TIED IN PLACE AND SECURED AGAINST DISPLACEMENT PRIOR TO PLACING CONCRETE. E. NO SPLICES OF REINFORCEMENT SHALL BE MADE EXCEPT AS DETAILED OR AUTHORIZED BY THE STRUCTURAL ENGINEER. LAP SPLICES,WHERE PERMITTED, SHALL BE A MINIMUM OF 48 BAR DIAMETERS FOR #6 BARS AND SMALLER AND 80 BAR DIAMETERS FOR #7 AND #8 BARS UNLESS NOTED OTHERWISE. ALL BARS SHALL BE CONTINUOUS AROUND CORNERS. F. PLACE (2) #5 BARS AROUND ALL OPENINGS IN CONCRETE WALLS AND SLABS. ALSO PROVIDE (2) #5 X 4'-0" DIAGONALLY AT EACH RE-ENTRANT CORNER. 8#+. %1.14#&1  41%-.'&)' 41#& 5 .#0&5%#2' #&&+6+10 09/12/16