HomeMy WebLinkAboutB16-0336_E-PA-201_1478900636.pdfSEE NOTE I FFD CONV. OUTLET 48" AFF SEE NOTE A SEE NOTE A SEE NOTE A SEE NOTE A LOUVERS LOUVERS NOTE: PROVIDE LOUVERS IN MILLWORK TO DISSIPATE HEAT FROM COMPRESSORS INSIDE MILLWORK EQUIPMENT DISCONNECTED REMOVED & REPLACED BY GC MILLWORK COUNTER FRONT REMOVED BY GC NEW COUNTER FRONT & SHELVES BY GC FS ADA SEATING 13'-10" CLEAR INSIDE BAR DYE MINIMUM SEE NOTE G SEE NOTE G AFD SEE NOTE D FS FS FS CONV. OUTLET 48" AFF CONV. OUTLET 48" AFF SEE NOTE A SEE NOTE A SEE NOTE A SEE NOTE A SEE NOTE A SEE NOTE A SEE NOTE G AFD SEE NOTE D AFD SEENOTE D FS FS FS ENLARGED ELECTRICAL FOOD AND BEVERAGE PLANS E-PA-201 1. --- 1. REFER TO E-PA-004 FOR CONSTRUCTION NOTES. 2. REFER TO ARCHITECTURAL DRAWINGS FOR DIMENSIONS, HEIGHT, FINISH AND SECURITY REQUIREMENTS. 3. COORDINATE MOUNTING HEIGHTS, COLORS AND LOCATION OF ALL WIRING DEVICE WITH ARCHITECT AND KITCHEN CONSULTANT. 4. ALL WIRING DEVICES MUST BE GANGED. 5. FURNISH & INSTALL REQUIRED JUNCTION BOXES IN ORDER TO COMPLY WITH NEC REQUIREMENTS. 6. ALL WIRE SHALL BE #12 EXCEPT FOR THE FOLLOWING: (A) WHERE OTHERWISE NOTED (B) FOR 120V CONDUCTOR LENGTHS IN EXCESS OF 75 FEET SHALL BE #10 AWG (C) CABLE AMPACITY DERATING BASED ON MULTICURRENT CONDUCTORS IN SAME RACEWAY (D) NEUTRAL CONDUCTOR SHALL BE #10 MIN. 7. ALL PENETRATIONS THRU FIRE RATED WALLS SHALL BE SEALED WITH LISTED MATERIALS/SYSTEMS TO RESTORE THE ORIGINAL FIRE RATING. 8. REFER TO PLUMBING PLANS FOR EXACT LOCATIONS OF MECHANICAL EQUIPMENT. 9. THE CASH REGISTER UNITS REQUIRE ISOLATED GROUND RECEPTACLES. OUTLET FOR CASH REGISTERS NEEDS TO BE 16" A.F.F. GENERAL CONTRACTOR TO CHECK THE ENTIRE SYSTEM FOR PROPER GROUNDING AND PROPER PANEL NEUTRAL BONDING. 10. ALL RECEPTACLES IN KITCHEN/PREPARATION AREAS SHALL BE GFI RECEPTACLES. 11. ELECTRICAL CONTRACTOR TO COORDINATE ALL KITCHEN EQUIPMENT REQUIREMENTS AND LOCATIONS BEFORE ANY ROUGH-IN WITH OWNER AND KITCHEN SUPPLIER. 12. ALL DISCONNECTS SHOWN FOR A/C UNITS ARE FURNISHED, INSTALLED AND WIRED BY ELECTRICAL CONTRACTOR. ENCLOSURES SHALL BE NEMA 3R. 13. WIRE GFCI DEVICE SUCH THAT THE DOWNSTREAM DEVICES ARE NOT AFFECTED BY GROUND FAULT INTERRUPTION (I.E., NON FEED THRU). EACH GFCI DEVICE SHALL BE SELF PROTECTING ONLY. 14. ANY UNAUTHORIZED CHANGES TO THE EQUIPMENT, DESIGN, OR INSTALLATION OF THE ELECTRICAL SYSTEMS WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ENGINEER IS UNACCEPTABLE AND GROUNDS FOR REMOVAL OF ALL LIABILITY OF THE ARCHITECT/ENGINEER FOR THE REVISED DESIGN. 15. CONTRACTOR SHALL VERIFY NAMEPLATE DATA OF ALL NEW AND EXISTING EQUIPMENT PRIOR TO INSTALLATION AND NOTIFY THE ENGINEER OF ANY DISCREPANCIES FOUND DURING THIS VERIFICATION. 16. VERIFY ALL DATA LINE RUNS WITH OWNER. 17. REFER TO KITCHEN CONSULTANT DRAWINGS FOR MORE DETAIL. 18. CONCRETE FLOOR SLAB SHALL BE INFRARAYED PRIOR TO TRENCHING OR CORING. ALL WORK, INCLUDING CORE DRILLING, X-RAY, INSTALLATION OF FIRE STOPPING, AND CONDUIT/CABLE INSTALLATION SHALL BE PERFORMED DURING NON-BUSINESS HOURS, INCLUDED IN BASE BID. ACTIVITY Draw Design Manager BY Check P L A N N I N G A R C H I T E C T U R E E N G I N E E R I N G I N T E R I O R S EST. 1915 DATE REVISIONS DESCRIPTION NO. FILE LOG STAMP 2016 © LEO A DALY Company Project No. 012-10378-000 AUGUST 19, 2016 5307 E. Mockingbird Lane, Suite 400 Dallas, TX 75206 USA Tel 214-526-1144 Fax 214-526-1411 GO, KA Monroe & Newell alibre VAIL CASCADE RESORT 1300 WESTHAVEN DRIVE VAIL, CO 81657 OWNER: VAIL HOTEL PARTNERS 1880 CENTURY PARK EAST SUITE 1016 LOS ANGELES, CA 90067 DESIGN DEVELOPMENT / PROGRESS THIS DOCUMENT IS RELEASED FOR TH PURPOSE OF DESIGN DEVELOPMENT AND PROGRESS UNDER THE AUTHORIT OF MARK B. MURPHY, PE #45799 ON JU 8, 2016. IT IS NOT TO BE USED FOR OTHER PURPOSES. 08/19/2016 DESIGN DEVELOPMENT / PROGRESS THIS DOCUMENT IS RELEASED FOR TH PURPOSE OF DESIGN DEVELOPMENT AND PROGRESS UNDER THE AUTHORIT OF MARK B. MURPHY, PE #45799 ON JU 8, 2016. IT IS NOT TO BE USED FOR OTHER PURPOSES. 08/19/2016 10/26/16