HomeMy WebLinkAboutB16-0336_FS-1E_1478900582.pdfR3 R2 R1 R4 R7 R14 R14 R9 R9 R9 R10 R10 R10 R11 R10 CONV. OUTLET 48" AFF B16 B9 B9 B5 B11 B13 B5 B18 B19 LOUVERS LOUVERS EQUIPMENT DISCONNECTED REMOVED & REPLACED BY GC MILLWORK COUNTER FRONT REMOVED BY GC NEW COUNTER FRONT & SHELVES BY GC B23 B22 B21 B1 B2 VAIL CASCADE RESORT 1300 WESTHAVEN DRIVE VAIL, CO 81657 OWNER: DEVELOPER: DESTINATION HOTELS &RESORTS 10333 EAST DRY CREEK ROAD, SUITE 450 ENGLEWOOD, CO 80112 © FAX (303) 623-6602 (303) 623-4927 Denver, Colorado 80202 1400 Glenarm Place, Suite 101 FAX (970) 949-4054 (970) 949-7768 Avon, Colorado 81620 70 Benchmark Road, Suite 204 P.O. Box 1597 Engineers, Inc. Monroe & Newell Email: avon@monroe-newell.com Email: denver@monroe-newell.com FoodStrategy, Inc. 1300 Piccard Drive Suite 207 Rockville, MD 20850 Phone: 301-926-8181 Fax: 301-926-8199 www.foodstrategy.com SEE SHEET FS-1UL FOR NOTE: EQUIPMENT SCHEDULE & UTILITY LOAD SCHEDULE SEE SHEET FS-1N FOR NOTE: NOTES AND DETAILS FLUORESCENT LIGHT FLT 14. 13. 12. 11. 10. 9. 8. 7. 6. 5. -4. 3. 2. 1. WORK DESCRIBED IN THESE NOTES IS TO BE PERFORMED UNDER DIVISION 16 (ELECTRICAL) IPW INTERCONNECTED POWER WIRING LT LIGHT ELECTRICAL CONNECTION/JUNCTION BOX ELECTRICAL SYMBOLS DUPLEX RECEPTACLE SINGLE RECEPTACLE DATA OUTLET PHONE OUTLET DR EC/JB DO PO SR ELECTRICAL NOTES QUAD RECEPTACLE QR 15. 16. 17. 18. 19. 20. 21. THIS DRAWING LOCATES FINAL ELECTRICAL POINTS OF CONNECTION FOR EACH FOODSERVICE EQUIPMENT ITEM. IT DOES NOT INDICATE UTILITY ROUGH - IN LOCATIONS. LOCATIONS, SIZES, AND HEIGHTS ABOVE THE FLOOR ARE APPROXIMATELY AS THEY WILL OCCUR ON THE EQUIPMENT ITEMS SHOWN. THE DESIGN OF SYSTEMS TO ACCOMMODATE THESE REQUIREMENTS IS TO BE IN ACCORDANCE WITH ALL APPLICABLE CODES AND MEET WITH THE APPROVAL OF ALL GOVERNING AUTHORITIES. UTILITIES SHOWN ARE FOR FOODSERVICE EQUIPMENT ITEMS ONLY. THIS DRAWING MUST BE USED IN CONJUNCTION WITH THE ELECTRICAL DRAWINGS FOR OTHER REQUIRED UTILITIES. CONCEAL ALL UTILITIES IN WALLS AND STUB - OUT OF WALLS AS REQUIRED FOR CONNECTIONS. DO NOT STUB OUT OF THE FLOOR UNLESS INDICATED ON PLANS AND/OR RUN EXPOSED ON THE FACE OF THE WALL. CONDUIT EXPOSED ABOVE WORK SURFACES TO BE STAINLESS STEEL OR CHROME PLATED. N/A N/A N/A PROVIDE CONDUIT AND WIRING BETWEEN ELECTRIC DEFROST UNIT COOLERS AND CONDENSING UNITS. PROVIDE COMPUTER GRADE, CLEAN, ISOLATED GROUND SERVICE FOR POINT - OF - SALE (POS) EQUIPMENT AND/OR ELECTRONIC POS AND/OR CASH REGISTERS. PROVIDE EMPTY CONDUIT BETWEEN POS AND/OR CASH REGISTER LOCATIONS AND CENTRAL OFFICE LOCATION, ETC. VERIFY EXACT LOCATIONS. SEE SPECIAL CONDITIONS PLAN OF EACH AREA FOR SIZE AND LOCATION OF CONDUIT FOR BEVERAGE SYSTEM LINES. CONDUITS FOR BEVERAGE SYSTEMS SHALL BE WATERTIGHT AND HAVE 24” (600MM) MINIMUM RADIUS BENDS AND PULL BOXES EVERY 75' (22.5 METERS) OR EVERY 3 BENDS. N/A PROVIDE DUPLEX CONVENIENCE OUTLET (120/1 O , 20A) AT 48” (1200MM) ABOVE FINISHED FLOOR UNLESS OTHERWISE INDICATED. N/A PROVIDE DISCONNECT SWITCH FOR EQUIPMENT AS REQUIRED. LOCATE SWITCH SO IT DOES NOT INTERFERE WITH EQUIPMENT FUNCTION. ALL CONTROL WIRINGS, INTERCONNECTIONS AND FINAL CONNECTIONS BY ELECTRICAL TRADE. IF EQUIPMENT COMES IN SECTIONS, ELECTRICAL TRADE TO RECONNECT ELECTRICAL LINES. N/A PROVIDE WATER PROOF SWITCH BEHIND EACH EVAPORATOR COIL IN WALK-INS AS MEANS OF DISCONNECT. N/A KITCHEN EQUIPMENT CONTRACTOR TO PROVIDE LIGHT FIXTURES AND BULBS LOOSE AT ALL WALK INS. ELECTRICAL TRADE TO PENETRATE WALK IN PANELS, EXTEND CONDUITS THROUGH OPENING FROM LIGHT FIXTURE OR ALARMS ETC, INSULATE INSIDE OF CONDUITS AND SEAL OPENINGS. ELECTRICAL TRADE TO PROVIDE JB ON TOP OF WALK IN, INSTALL LIGHT FIXTURES AND BULBS AND CONNECT. N/A N/A 1/4" = 1'-0" 0000000000000000 1' 5' 10' 10/26/16