HomeMy WebLinkAboutB16-0336_P-PA-003_1478900717.pdfPLUMBING DETAILS P-PA-003 ACTIVITY Draw Design Manager BY Check P L A N N I N G A R C H I T E C T U R E E N G I N E E R I N G I N T E R I O R S EST. 1915 DATE REVISIONS DESCRIPTION NO. FILE LOG STAMP 2016 © LEO A DALY Company Project No. 012-10378-000 AUGUST 19, 2016 5307 E. Mockingbird Lane, Suite 400 Dallas, TX 75206 USA Tel 214-526-1144 Fax 214-526-1411 GO, KA Monroe & Newell alibre VAIL CASCADE RESORT 1300 WESTHAVEN DRIVE VAIL, CO 81657 OWNER: VAIL HOTEL PARTNERS 1880 CENTURY PARK EAST SUITE 1016 LOS ANGELES, CA 90067 & SCREW CLEANOUT WALL FLOOR LINE PLUGGED TEE W/ CHROME WALLCOVER WASTE OR VENT MAY EXTEND AS A AS CLEANOUT TO GRADE. BALANCE OF PIPING SAME 1/8"C.I. BEND PIPE (TYP.) INSULATION (TYP.) AND SMALLER FOR PIPE 2 1/2" HANGER ROD PIPE INSULATION H.W. PIPE 3" AND PIPE ROLLER FOR UNISTRUT CHANNEL AND LARGER LOCK NUTS(TYP. FOR ALL SUPPORTS) DOUBLE NUTS OR FLAT WASHERS SHIELD FOR PIPE 3" FOR PIPE 2-1/2" AND SMALLER LARGER PIPE CLAMP & SHIELD HALF ROUND OR FULL ROUND EXTEND 2" BEYOND AND INSULATION SHALL SINGLE PIPE RUNS CLEVIS HANGER FOR GALVANIZED IRON SHEET SHIELD GALV. SHIELD EACH WAY. INSULATION AT EACH HANGER PROVIDE A SECTION OF HIGH POINT. INSULATION MAY BE COMPRESSION STRENGTH BALL VALVE (TYP.) CHECK VALVE (TYP.) LINE FULL SIZE OF VALVE OUTLET AMTROL MODEL ST-5 (ASME) BLADDER TYPE EXPANSION TANK 120°F FINISHED FLOOR D WATER THERMOMETER PRESS. RELIEF VALVE ASME RATED TEMP. & 4" HOUSEKEEPING PAD HEATER CIRCULATING PUMP, CP-1 1 1/2" DHW SUPPLY 1 1/2" DCW SUPPLY 1" HWR WH-1 VACUUM RELIEF (TYP.) AQUASTAT INTERLOCKED WITH TIMECLOCK SUPPORT AT THIS POINT HUB JOINT FINISHED FLOOR FILL "P" TRAP DEEP SEAL STRAINER SCALE: WATER HEATER DETAIL N.T.S. 8 SCALE: PIPING HANGERS AND SUPPORT DETAIL N.T.S. 5 SCALE: WALL CLEANOUT DETAIL N.T.S. 6 SCALE: FLOOR DRAIN DETAIL N.T.S. 7 ABOVE UNIT FOR MAINTENANCE 1'-6" MINIMUM CLEARANCE VALVE BALL TEST COCKS BALL VALVE BALL VALVE STRAINER ASSEMBLY BACKFLOW PREVENTER DISCHARGE TO FLOOR DRAIN RELIEF VALVE OUTLET TO FLOOR FITTING AIR GAP BOTTOM FOR MAINTENANCE 2'-6" MINIMUM CLEARANCE AT CLAMP CORNERS AT 45° ANGLE CHAMFER RISER CONCRETE FLOOR SLAB PLAN VIEW RISER CLAMP RISER ELEVATION VIEW IF REQUIRED (SEE SPECS) INSULATION SLEEVE SHEET METAL GALVANIZED 1 1/2" STEEL PIPE MIN. 3" STOP PLATE 1 1/4" ANCHOR AND WATER WELD ALL AROUND HOT DIP SLEEVE TO REGALVANIZED AFTER WELDING BOLT AND NUT PRESSURE PLATE RUBBER SEALING ELEMENT PRESSURE PLATE CAULK WITH LINK SEAL SCHEDULE 40 GALV. STEEL PIPE. SIZE AS REQUIRED ( NON-INSULATED PIPE OR CONDUIT ) LINK SEAL FIRE RESISTIVE FOR FIRE RATED WALLS PROVIDE NOTE: STAINLESS STEEL VENT CLAMP FLASHING SEALANT ROOF DECK ROOFING MIN. 12" 10" 12" SCALE: PLUMBING VENT THRU ROOF X DETAIL N.T.S. 3 SCALE: PIPE SLEEVE THRU WALL DETAIL N.T.S. 1 SCALE: TYPICAL FLOOR PENETRATION DETAIL N.T.S. 2 SCALE: REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTER ASSEMBLY N.T.S. 4 10/26/16