Loading...
HomeMy WebLinkAboutWindow Specs_1.pdfCM-8 CASEMENT Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com Architect Series®Designer Series®ProLine 450 Series Rev. 08/22/2016 GLAZING PERFORMANCE - TOTAL UNIT Aluminum-Clad Exterior Vent Glazing ThicknessType of Glazing NFRC Certified Product # Glass (mm) Gap Fill Performance Values1 Shaded Areas Meet ENERGY STAR® Performance Criteria in Zones Shown Ext.Int.U-FactorSHGCVLT %CRU. S.Canada 2 Zone ER Zone HIGH ALTITUDE GLAZING N NC SC S 1 2 3 11/16"Advanced Low-E IG PEL-N-11-09108-00001 2.5 2.5 air 0.31 0.26 48 58 with grilles-between-the-glass PEL-N-11-09730-00001 0.31 0.24 44 58 with integral grilles PEL-N-11-09318-00001 0.32 0.24 44 58 11/16"Advanced Low-E IG PEL-N-11-09109-00001 3 3 air 0.32 0.26 48 57 with grilles-between-the-glass PEL-N-11-09731-00001 0.32 0.24 43 57 with integral grilles PEL-N-11-09319-00001 0.32 0.24 43 57 11/16"SunDefense Low-E IG PEL-N-11-09121-00001 2.5 2.5 air 0.31 0.20 45 58 with grilles-between-the-glass PEL-N-11-09743-00001 0.31 0.18 41 58 with integral grilles PEL-N-11-09331-00001 0.32 0.18 41 58 11/16"SunDefense Low-E IG PEL-N-11-09122-00001 3 3 air 0.31 0.20 44 57 with grilles-between-the-glass PEL-N-11-09744-00001 0.31 0.18 40 57 with integral grilles PEL-N-11-09332-00001 0.32 0.18 40 57 11/16"AdvancedComfort Low-E IG PEL-N-11-10652-00001 2.5 2.5 air 0.27 0.26 47 45 21 with grilles-between-the-glass PEL-N-11-10694-00001 0.27 0.23 43 45 20 with integral grilles PEL-N-11-10666-00001 0.28 0.23 43 45 18 11/16"AdvancedComfort Low-E IG PEL-N-11-10653-00001 3 3 air 0.27 0.26 47 44 21 with grilles-between-the-glass PEL-N-11-10695-00001 0.27 0.23 42 44 20 with integral grilles PEL-N-11-10667-00001 0.28 0.23 42 44 18 11/16"NaturalSun Low-E IG PEL-N-11-09079-00001 2.5 2.5 air 0.32 0.48 55 57 28 with grilles-between-the-glass PEL-N-11-09701-00001 0.32 0.44 50 57 25 with integral grilles PEL-N-11-09289-00001 0.33 0.44 50 57 24 11/16"NaturalSun Low-E IG PEL-N-11-09080-00001 3 3 air 0.32 0.47 54 56 27 with grilles-between-the-glass PEL-N-11-09702-00001 0.32 0.43 49 56 25 with integral grilles PEL-N-11-09290-00001 0.33 0.43 49 56 24 (1) Glazing performance values are calculated for Pine using NFRC 100, NFRC 200 and NFRC 500. Thermal performance of other wood species may vary. ENERGY STAR® values are updated to 2016 (Version 6) criteria. (2) The values shown are based on Canada's updated ENERGY STAR® 2015 initiative. See the Product Performance section for more detailed information or visit www.energystar.gov for Energy Star guidelines. R-Value = 1/U-Factor SHGC = Solar Heat Gain Coefficient VLT % = Visible Light Transmission CR = Condensation Resistance ER = Canadian Energy Rating Climate Zones