HomeMy WebLinkAboutWindow Specs_1.pdfCM-8
CASEMENT
Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com
Architect Series®Designer Series®ProLine 450 Series
Rev. 08/22/2016
GLAZING PERFORMANCE - TOTAL UNIT
Aluminum-Clad Exterior
Vent
Glazing ThicknessType of Glazing NFRC Certified
Product #
Glass (mm)
Gap
Fill
Performance Values1 Shaded Areas Meet ENERGY STAR® Performance Criteria in Zones Shown
Ext.Int.U-FactorSHGCVLT %CRU. S.Canada 2
Zone ER Zone
HIGH ALTITUDE GLAZING N NC SC S 1 2 3
11/16"Advanced Low-E IG PEL-N-11-09108-00001 2.5 2.5 air 0.31 0.26 48 58
with grilles-between-the-glass PEL-N-11-09730-00001 0.31 0.24 44 58
with integral grilles PEL-N-11-09318-00001 0.32 0.24 44 58
11/16"Advanced Low-E IG PEL-N-11-09109-00001 3 3 air 0.32 0.26 48 57
with grilles-between-the-glass PEL-N-11-09731-00001 0.32 0.24 43 57
with integral grilles PEL-N-11-09319-00001 0.32 0.24 43 57
11/16"SunDefense Low-E IG PEL-N-11-09121-00001 2.5 2.5 air 0.31 0.20 45 58
with grilles-between-the-glass PEL-N-11-09743-00001 0.31 0.18 41 58
with integral grilles PEL-N-11-09331-00001 0.32 0.18 41 58
11/16"SunDefense Low-E IG PEL-N-11-09122-00001 3 3 air 0.31 0.20 44 57
with grilles-between-the-glass PEL-N-11-09744-00001 0.31 0.18 40 57
with integral grilles PEL-N-11-09332-00001 0.32 0.18 40 57
11/16"AdvancedComfort Low-E IG PEL-N-11-10652-00001 2.5 2.5 air 0.27 0.26 47 45 21
with grilles-between-the-glass PEL-N-11-10694-00001 0.27 0.23 43 45 20
with integral grilles PEL-N-11-10666-00001 0.28 0.23 43 45 18
11/16"AdvancedComfort Low-E IG PEL-N-11-10653-00001 3 3 air 0.27 0.26 47 44 21
with grilles-between-the-glass PEL-N-11-10695-00001 0.27 0.23 42 44 20
with integral grilles PEL-N-11-10667-00001 0.28 0.23 42 44 18
11/16"NaturalSun Low-E IG PEL-N-11-09079-00001 2.5 2.5 air 0.32 0.48 55 57 28
with grilles-between-the-glass PEL-N-11-09701-00001 0.32 0.44 50 57 25
with integral grilles PEL-N-11-09289-00001 0.33 0.44 50 57 24
11/16"NaturalSun Low-E IG PEL-N-11-09080-00001 3 3 air 0.32 0.47 54 56 27
with grilles-between-the-glass PEL-N-11-09702-00001 0.32 0.43 49 56 25
with integral grilles PEL-N-11-09290-00001 0.33 0.43 49 56 24
(1) Glazing performance values are calculated for Pine using NFRC 100, NFRC 200 and NFRC 500. Thermal performance of
other wood species may vary. ENERGY STAR® values are updated to 2016 (Version 6) criteria.
(2) The values shown are based on Canada's updated ENERGY STAR® 2015 initiative.
See the Product Performance section for more detailed information or visit www.energystar.gov for Energy Star guidelines.
R-Value = 1/U-Factor
SHGC = Solar Heat Gain Coefficient
VLT % = Visible Light Transmission
CR = Condensation Resistance
ER = Canadian Energy Rating
Climate Zones