HomeMy WebLinkAboutB16-0359_Line Diagram_1478908807.pdfPage 4 of 4 9/1/2016
P.O. Box 7627, Avon, CO 81620 | P: 970.306.4233 | F: 866.403.3485 | www.activeenergies.com
4 #10 PV Wire
1# 6G Bare Cu
Conductors in Free Air
Inverter w/
Integrated DC Disconnect
SolarEdge SE7600A-US
NEMA 3R / Arc Fault / Rapid Shutdown
Max AC Output: 32A @ 240V
Located on south side of home
DC Grounding
Electrode Conductor
solid bare #6 Cu
per NEC 250.66(C)
Service Panel
south side of home
Line Diagram
Stadler Residence
2703 Cortina Lane
Vail, CO 81657
9.6 kW Utility Interactive Photovoltaic
System
Modules: 96 SunTegra STS-100M-B4U
Voc = 15.32V
Isc = 8.72A
Optimizers: 32 integrated SolarEdge P300
2 String X 16 Modules/Inverter
Inverter: SolarEdge SE7600A-US
Operating Voltage: 350V
Operating Current: 23A
Max System Voltage: 500V
Max Output Current: 30A
Tilt Angle: 26.57º
Array Azimuth: 150°
Production: 13,756kWh/yr
Notes:
- See Calculation Sheet for conductor
sizing.
- All conductors are copper unless
otherwise noted.
- Inverter listed (UL-1741) to de-
energize upon loss of utility voltage
per NEC 690.61.
- Inverter has integral ground-fault
protection per NEC 690.5
- 240V 1 Phase Service Panel rating
of 200A (bus rating 200 amp and 200
Main disconnect) to accommodate
40A + 200A = 240A supply (up to
120% of connected power sources
from residential installations per NEC
690.64(B)(2))
Array mounted on roof
96 Canadian Solar CS6P-265P-SD Solar Panels
32 integrated SolarEdge P300 DC Optimizers
On south
side of
home
Pass-Thru
Box
Located on
roof
Placard on meter and main panel stating
”Photovoltaic System Connected”
per Holy Cross specifications
60A, 40a
fused
Disconnect
adjacent to
meter
+/-40'
¾" C EMT/FMC
2 #10 THWN-2
1 #10 Ground
+/-10'
¾" C EMT/PVC/FNMC/NM-B
3 #8 THWN-2
1 #10 Ground
...
Backfeed
Fuses:
40A
2p
240v
40A
1 2 3 4 5 6 7 9 8 46 47 48
... 49 50 51 52 53 54 55 57 56 94 95 96
09/22/16