HomeMy WebLinkAboutB16-0443_A2.0_1478908869.pdfPLAN LEGEND:
EXISTING CONSTRUCTION TO
REMAIN
NEW 8" CMU WALL CONSTRUCTION
ADDITIONAL STORAGE SQUARE
FOOTAGE FOR LA CANTINA
PROPOSED FLOOR PLAN
SCALE: 1/4" = 1'-0"
NORTH
ENLARGE
STORAGE
AREA
NEW OPENING IN
EXISTING WALL
EXISTING ELEVATOR
EXISTING STAIR
2
A2.0
NEW
BAR
A2.0
1
EXISTING FIRE/HEAT
DETECTOR TO BE MOVED ONE
STRUCTURE TEE EAST TO
REMAIN IN PARKING GARAGE
EXISTING
KITCHEN
EXISTING
BAR
EXISTING
RESTAURANT SEATING
EXISTING
INDOOR PATIO
EXISTING
FOOD
STORAGE
EXISTING
DISHWASHING
EXISTING WALK-IN
EXISTING
ICE MACHINE
EXISTING
FREEZER
EXISTING GATE
EXISTING GATE
EXISTING TELEPHONE
EXISTING COLUMN
ADA ACCESSIBLE TABLE WITH
27" KNEE CLEARANCE
28" - 34" TABLE TOP HEIGHT
AND ACCESSIBLE ROUTE WITH
CLEAR FLOOR AREA OF 30"x48"
EXISTING
GREASE
TRAP
12"x12" EXISTING
HAND SINK
12"x12" EXISTING
HAND SINK
REMOVE EXISTING WALL AND
DOORS
EXISTING FIRE/HEAT
DETECTOR TO BE MOVED ONE
STRUCTURE TEE EAST TO
REMAIN IN PARKING GARAGE
AT ENLARGED STORAGE:
x
NEW WALLS TO BE 3 HOUR RATED CONCRETE
BLOCK - SEE UL DESIGN #UL U914 (2/A0.0)
x
NEW FLOOR TO BE POURED CONCRETE TO
MATCH KITCHEN FLOOR LEVEL
x
PROVIDE 3 HOUR RATED DROPPED CEILING
w/STEEL FURRING w/DRYWALL AND PAINT
FINISH - SEE UL DESIGN #UL J502 (1/A0.0)
EXISTING CONSTRUCTION TO
BE REMOVED
EXISTING ELEVATOR
NEW
BAR
KEG COOLER
59"x22"
REFRIGERATOR
WORK TOP
27"x30"
FROZEN
DRINK
MACHINE
22"x24"
SANDWICH
REFRIGERATOR
27"x30"
TABLE
24"x24"
BEER
COOLER
30"x30"
ICE WELL
20"x24"
DUMP
SINK
19"x18"
GLASSES
BOTTLE
RACK
24"x24"
CASH
REGISTER
SUPPLIES
19"x30"
SOILED
TABLE
CART
19"X24"
EXISTING MOP SINK
AND HAND SINK
LOW WALL
COLD WATER TO ICE
WELL - BEVERAGE
CARBONATOR TO BE
LOCATED BELOW ICE
WELL TO HAVE BACK
FLOW PREVENTER
ALL BAR EQUIPMENT
TO BE DRAINED
INDIRECTLY TO
FLOOR SINK WITH 2"
AIR GAP
NEW FLOOR SINK TO
CONNECT TO EXISTING
3" SEWER BELOW
PROVIDE HOT & COLD
WATER TO DUMP SINK
NEW WOOD FRAMED
KNEE WALL TO
SUPPORT BAR
EXISTING
FLOOR SINK
12'x12' MOP &
CHEMICAL STORAGE
EXISTING
MECHANICAL
EXISTING
SKI MUSEUM
EXISTING
PARKING GARAGE
NEW
STORAGE
ROOM
EXISTING
SPACE
EXISTING DOOR
AT NEW STORAGE ROOM:
x
NEW WALL TO BE 3 HOUR RATED CONCRETE
BLOCK - SEE UL DESIGN #UL U914 (2/A0.0)
x
PROVIDE 3 HOUR RATED DROPPED CEILING
w/STEEL FURRING w/DRYWALL AND PAINT
FINISH - SEE UL DESIGN #UL J502 (1/A0.0)
NEW 3'-0" HOLLOW METAL DOOR
A2.0
PROPOSED FLOOR PLAN
LA CANTINA RENOVATIONS
LEVEL THREE, VAIL TRANSPORTATION CENTER
241 SOUTH FRONTAGE ROAD, VAIL, COLORADO
EAGLE COUNTY ACCT #:R046881
TOV PERMIT
ENLARGED PLAN @ NEW BAR
SCALE: 1/2" = 1'-0"
NORTH
A2.0
2
3
NEW STORAGE ROOM
SCALE: 1/2" = 1'-0"
NORTH
A2.0
11/09/16