A17-0021_Cut Sheets_1492020720.pdf
I � Gamewell Gamewell FIRE CONTROL INSTRUMENTS Retrofit Kits by Honeywell Description Gamewell to E3 Series® The Gamewell Retrofit Kits offered by Gamewell-FCI pro- vide a simple way to convert the following existing Gamewell legacy Systems to a new E3 Series®fire alarm panel. • IF602 panel • IF610 panel • IF632 panel � migamor The Retrofit Kits offer a cost-effective solution to change `opo the Gamewell legacy panels without replacing the existing ` °° �' oda ddd Gamewell backbox. This solution eliminates the expensive cost of repairing walls, buying new cabinets or replacing T the existing Gamewell backbox. • ��� ■1.. •Ipp All retrofit kits provide backplates that mount directly into iCZ . �I:p. the Gamewell backboxes. Each backplate includes mount- ing patterns to allow an easy installation of the E3 Series plates and sub-assemblies. The front panel displays can be retrofitted to the E3 Series LCD-E3/LCD-SLP using a simple mounting plate. IF600XL retrofit kits include a 3-bay 11111 slot door for addressable switch buttons, LED drivers, and a paging microphone. IF600XL B-Slim Gamewell RAN annunciator can also be retrofitted to accommodate an E3 Series supported annunicator by Features reusing the existing backbox. Retrofitting is a cost effective way to upgrade your facilities' • Listed under UL®Standard 864, 9th edition. fire alarm control panel without swapping out smoke detec- • Cost effective solution for upgrading an existing system tors and notification devices. Changing your legacy without buying a complete E3 Series System. Gamewell System to the Gamewell-FCI,E3 Series System • Upgrades to the state-of-the-art E3 Series fire alarm converts your fire alarm system, so that it is compliant with control panels. the most current UL®and NFPA codes and standards. • Offers a simple plate system for easy installation. Installation • Allows the existing cabinet to remain mounted on the wall. To retrofit from a Gamewell panel to an E3 Series System, • Reuses the existing System Sensor or Apollo detectors/ refer to the following time-saving steps which can save a modules, and notification devices. lot in setup and labor costs. • Remote annunciator retrofit available. 1. Remove all field wiring from the legacy Gamewell control boards that are installed inside the cabinet. 2. Remove the front door or inner doors. E3 Series Features 3. Unscrew the Gamewell panel mounting plate from the For additional information on the E3 Series features, refer backbox. to the E3 Series Data Sheet Part Number: 9020-0637. 4. Install the new retrofit mounting plate for E3 Series sub-assemblies or plates. 5. Install the new E3 Series panels and connect with the existing wiring. SIGNALING 6. Auto configure the system or custom program the E3 Series. E3Aeries®is a registered trademark of Honeywell International Inc. LISTED UL is a registered trademark of Underwriter's Laboratories Inc. SI 869 ISO 9001 GAMEWELL-FCI QUALITY SYSTEMS 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel: (203)484-7161 •Fax:(203)484-7118 Specifications are for information only,are not intended for installation purposes,and are subject to change without notice.No responsibility is assumed by Gamewell-FCI for their use. ©2014 by Honeywell International Inc. All rights reserved. www.gamewell-fci.com 9021-60678 Rev. D page 1 of 2 Gamewell RAN2 Retrofit Ordering Information Figure 1.1 illustrates the Gamewell RAN2 retrofit. Part Number Description IF600-RETROFIT Gamewell1F602/IF610 (System Sensor or Apollo Retrofit) The Retrofit Kit includes the following: • Front door • Backbox mounting plate Display plate Loop Cards The 1F600 Retrofit Kit supports up to two ILI loop cards: uY/Ef81 eL b E u ILI-MB-E3 • 1L195-MB-E3 - )Gxn�N�E04f ICSNON�[C4E Si�fw4[ NO • ILI-S-E3 • 1L195-S-E3 The following E3 Series sub-assemblies can be used in the 1F600 Retrofit Kit. • PM-9/PM-9G Power Supply(required) Figure 1 Gamewell RAN-7100 • LCD-E3 LCD Display(required) Retrofit Cabinet Installation • LCD-SLP LCD Touchscreen Display(optional) Figure 2 shows an IF600XL/632 configuration. • DACT-E3 Dialer(optional) • RPT-E3-FO/RPT-E3-UTP Network Repeater(optional) 10 IF600XL-RETROFIT Gamewell IF602XL,IF610XL, IF632 A (System Sensor or Apollo Retrofit) The Retrofit Kit includes the following plates: • Inner display door • Inner dead front cover :� �f, • Inner 3-bay door • Backbox mounting plate 1 The above mounting plates support one of the following E3 ; Series mounting plates(sold separately). •izbat- __. • E3-ILI-C • E3-INCL-C j4 igo it 1,,„..-70,-,,,,..• E3-ILI-C Mounting Plate: E3-ILI-C Mounting Plate accommodates the following: • Choice of two ILI loop cards • ILI-MB-E3 • 1L195-MB-E3 • ILI S E3 • 1L195-S-E3 E3-INCC-C Mounting Plate: Figure 2 IF600XL/632 E3-INCC-C Mounting Plate accommodates the following: • Figure 3 shows an 1F600 configuration. Choice of one ILI loop cards: • ILI-MB-E3 • 1L195-MB-E3 • ILI-S-E3 • ILI95-S-E3 1.440411 Optional-Select One of the following INI-VG Series boards: • INI-VGC Command Center �11111111 • INI-VGE Voice Gateway • INI-VGE Bulk Voice Gateway VIIW.C4°74 • 11 C1‘11 ii • o 11411141111111/4 Figure 3 IF600 GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 9021-60678 Rev. D page 2 of 2 www.gamewell-fci.com Gamewell ILIMBE3 Fe' INS FIRE TCORUMENTSNTROL Series by Honeywell Description Intelligent Loop Interface-Main Board ILI-MB-E3 • yit _ The Intelligent Loop Interface-Main Board (ILI-MB-E3) is `,i'•` , "" 1- E_,--•-•-•44:0 _•: the main interface for the E3 Series® product line. With its •Ua"4 I- ,rz � = state-of-the-art 32 bit RISC processor, this compact"panel "+e ¶S�.....�`°I'.rte # on a board" provides a powerful addition to Gamewell- — f ) FCI's single pair conductor solutions. This intuitive design provides two (2), signaling line circuits, two (2), notification aPplication circuits, local energycity box output, auxiliary • r; ': ti - I relay functions, and auxiliary power output.These features, ILI-IvB-E3 combined with built-in network and serial protocols, allow this module to support a host of new and existing products, Features resulting in a building block approach to fire alarm panel design. ILI-MB-E3 and ILI-S-E3: • Listed under UL Standard 864, 9th Edition The ILI-MB-E3 is network ready and occupies one of 64 • Network ready integral 625K baud ARCNET nodes,operating at 625K baud.When this sub-assembly is • 115.2K baud RS-232 integrated with proven Broadband components, the result • Signaling line circuits with: is a flexible yet powerful integrated audio solution. When -Two(2), Class A, Style 6, 7*or Class B, Style 4 transmitting to remote locations, the optional RPT-E3 pro- circuits vides the ILI-MB-E3 with valuable signal boosting and tran- -40 Character user-defined text per device sient protection,as well as connectivity using both wire and -Capacity of 159 sensors and 159 addressable fiber-optic cables. modules per circuit • 4100 event history log The ILI-MB-E3 provides two (2), signaling line circuits and *Style 7 wiring requires the use of System Sensor M500X terminals for the connections to up to 159 detectors and Isolator Modules. 159 modules per SLC in Velociti°. In clip mode, each SLC ILI-MB-E3 Only: supports 99 detectors and 98 modules. The RS-485 inter- • Two(2),notification appliance circuits,Class"A",Style Z face can support up to a total of sixteen (16), ASM-16 and/ or Class B, Style Y rated at 2.0 amps. per circuit or sixteen (16),ANU-48 remote LED driver modules. • RS-485 supporting sixteen (16),ASM-16 switch mod- ules and/or ANU-48 LED driver modules The ILI-MB-E3 relay outputs include system alarm, super- • Alarm, trouble, and supervisory dry contacts Form"C", visory, and system trouble contacts. The ILI-MB-E3 pro- rated at 2 amp. @ 30 VDC(resistive) vides output for a local energy city master box or remote • Supports six(6),local/remote LCD-E3 annunciators and location which is non power-limited. All other wiring is five (5), LCD-7100 annunciators power-limited. An ISO 9000-2000 Company SIGNALING yr� ® MEA City of 1,, 1 Chicago City of E3 Series,®NetSOLO,°and Velociti®are registered trademarks of Honeywell International LISTED APPROVEDApproved f`° Approved Denver Inc. a•::i Approved S1869 3025415 231-06-E 71650694:268 ci•::z 71654694:269 rho,rise GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 Specifications are for information only,are not intended for-installation purposes,and are subject to change without notice.No responsibility is assumed by Gamewell-Fa far their use. cr2037byHoneywell International Inc. Al rights reserved. www.gamewell-fci.com 9020-0605 Rev.el page 1 of 2 'c zz Y,i 0_ ` - i y-- r ` ' l',.u. .� Specifications rt,�, k"r'„ , - A����;• Operating Voltage: 24 VDC FWR = s, 71111 t; -;'- (from PM-9 Power Supply) if:; Y,-' 11 ;;Q ,s-1_'� ; Operating Current: 0.081 amp. 1-Iki-, I I 1 1=� F* Alarm Current: 0.150 amp. max. 3- :94ss�.4;�� '1= ..•••� r . n Operating Temperature: 32°to 120° F 0°to 49° C) Relative Humidity: 0 to 93%, non-condensing ILI-S-E3 at 90° F (32° C) SLC 40 Ohms maximum line impedance.- ILI-S-E3 0.5 laf maximum line capacitance. The Intelligent Loop Interface-Expansion Board (ILI-S-E3) provides the E3 Series control panel with two(2),additional signaling line circuits.The layout is similar to the ILI-MB-E3 Ordering Information except a number of components are omitted. The ILI-S-E3 occupies one node on the Broadband network. The ILI-S- Model Description E3 provides two(2), signaling line circuits and terminals for ILI-MB-E3 Intelligent Loop Interface-Main Board the connections to up to 159 detectors and 159 modules ILI-S-E3 Intelligent Loop Interface-Expansion Board per SLC in Velociti mode. In clip mode, each SLC supports 99 detectors and 98 modules. Installation Typically, the ILI-MB-E3 or ILI-S-E3 can be mounted in the following E3 Series cabinets: • Cabinet B and D, backbox • Cabinet C, INX-E3 sub-assembly plate • Cabinet C, INCC-E3 sub-assembly plate For instructions on installing the ILI-MB-E3 or ILI-S-E3, refer to the E3 Series°Expandable Emergency Evacuation Installation/Operating Manual, Part Number: 9000-0574, the ILI-MB-E3 Installation Instructions, Part Number: 9000- 0579,or the ILI-S-E3 Installation Instructions, Part Number: 9000-0569. GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 9000-0605 Rev.el page 2 of 2 www.gamewell-fci.com Gamewell RPT-E3 CI Fei IN FIRESTCORUMENTSROL NT by Honeywell Description Network Repeater The ARCNET Repeater Module (RPT-E3) is an optional component of the E3 Series®and S3 Series fire alarm con ' - �=�;• • trot panels. It allows the following remotable E3 Series and -•,1- ,r.lrr• y„ _ .•i S3 Series sub-assemblies to connect to the Broadband r:�.....•.l f 0 r °L`i ;,I a. 11/• network from the remote locations: • ILI-MB-E3/IL195-E3 Series •°•t ai{}s„ .i 'gE • S3 Series, SLP(Smart Loop Panel) _ ga'.r l- . ate_.• • ANX-SR/ANX-MR-UTP/ANX-MR-FO '•- {_i •��s,::`' b ii�J • NGA __ "I. �:�.m•. The RPT-E3 comes standard with network connections • - •• 2- ' ••.• using unshielded,twisted pair, copper wire.The following g.• ..,�_: optional fiber-optic network connections usingadd-on 7-1' .� ' ` modules are available. • t 4.1.011. . • FML-E3 multi-mode fiber module (optional) • FSL-E3 single-mode fiber module(optional) RPT-E3-UTP Installation Features The RPT-E3 is adaptable for an installation in the standard E3 Series and S3 Series cabinets. Typically,the RPT-E3 module is mounted on standoffs on the top of the right side • Listed under UL®Standard 864, 9th Edition. of the ILI-MB-E3/IL195-MB-E3/ANX modules and SLP • Provides the capability for networked E3 Series and S3 motherboard. Series sub-assemblies to connect in Styles 4 or 7 For instructions on the installation of the RPT-E3, refer to configurations. the following documents: • Standard with unshielded, twisted-pair copper wire • E3 Series®Expandable Emergency Evacuation network connection. Installation/Operation Manual, P/N: 9000-0574 • Add-on fiber-optic modules allow the network connec- • RPT-E3-UTP Installation Instructions, P/N: 9000-0580 tion through single or multi-mode fiber-optic cables. • S3 Series UL Listing Document, P/N: LS10005-051GF E Specifications • 625K baud ARCNET Repeater. Operating Voltage: 24 VDC FWR Operating Current: 0.016 amp Ordering Information Alarm Current: 0.017 amp Operating Temperature: 32°to 120° F(0°to 49°C) Relative Humidity: 0 to 93%, non-condensing at Part Number Description 90° F (32° C) RPT-E3-UTP Network Repeater, unshielded,twisted-pair Wiring Specifications: Copper Wire: 16 to 18 AWG twisted-pair, unshielded FML-E3 Multi-mode fiber-optic module for Up to 3,000 ft. (914.4 m)between RPT-E3-UTP(one channel) each node. FSL-E3 Single-mode fiber-optic module for Fiber-Optic Cable: Up to 200 microns(optimized for RPT-E3-UTP(one channel) (FML-E3 only) 62.5/125 microns). Up to 8 dB loss between nodes. Fiber-Optic Cable: Optimized for 9/125 micrometer SIGNALING (FSL-E3 only) cable)@ 1310 nm. MEA m Upto 30dB loss between nodes. ® ® City of Approved `r Chicago City of E3Series(saregisteredtrademarkofl-bneywellInternationalInc. LISTED APPROVED FDNY: Approved Denver UL®is a registered trademark of Uxlennaiters Laboratories Inc. S1869 3025415 COA#6077 7165-1703:0125 cies,, Approved aeee2 High Roe ISO 9001 aaiMANUFACTURING YTE GAMEWELL-FCI niir SS 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 Specifications are for information only,are not intended for installation purposes,and are subject to change without notice.No responsibility is as red by Garneeell-Fa for their use. C2013byHoneywell International Inc. Al rights reserved. www.gamewell-fci.com 9020-0609 Rev.L page 1 of 1 Gamewell DACT-E3 m Fe i INS FIRE TRUMENTS CONTROL by Honeywell Description Digital Alarm The Digital Alarm Communicator Transmitter(DACT-E3) is Communicator Transmitter an optional component of the E3 Series® Expandable 7° ., ,, M ki.V:ar.ti, 1IA Emergency Evacuation System. The DACT-E3 sends digi _ n € ==,p �: p�,,�3 tal signals over the telephone network to a central station. , --.„.;110i ,'yD..9 •':":=1. This module can be located in the main cabinet or remotely . mI jr' .ni•''iiiiiiiiiiii°°°' "' located via a local RS-485 serial interface. ,` :_,,,,,, The DACT-E3 is compatible with digital alarm communica- , ^ ' :,,, Li„i,,,',i • i 6.4, tor receivers (DACRs) that receive the following signaling """'T`;• r formats: R"° i ii W • SIA DC8 • 3+1 2300 Hz 1-, .. ..•G • SIA DCS20 • 4+2 1400 Hz - Ng': n- • Ademco Contact ID • 4+2 2300 Hz own `l .� .� • 3+1 1400 Hz fi :• , - "•` In addition to the DACT-E3 being compatible with digital 11r 1 signaling formats, the DACT-E3 features numerous for- ° mats for communication to a central station. As a digital DACT-E3 communicator, the DACT-E3 complies with FCC Part 8, Telecommunication Standards for DC and AC Ringer Features Equivalence. • Listed under UL®Standard 864, 9th Edition Installation Instructions • Communicates with the E3, ILI-MB-E3/ILI95-MB-E3 The DACT-E3 is adaptable for installation in standard E3 sub-assembly via RS-485 Series°System cabinets. Typically, the DACT-E3 module • Communicates in a variety of formats (including full mounts on standoffs on top of the left side of the ILI-MB- Contact ID) E3/ILI95-MB-E3 module. Either unit can be easily con- • Transmits and verifies data to the central station nected to the backbox or sub-assembly plate depending on • Offers pre-programmed dialing to the central station the cabinet module. phone number Note: For instructions on installing the DACT-E3, refer to • Performs on and off-hook status to the phone lines • Traces proper central station"ACK"and"Kiss off'tone the E3 Series® Expandable Emergency Evacuation Instal • lation/Operation Manual, Part Number: 9020-0574 or the Activates hang-up and release phone lines • DACT-E3 Installation Instructions Part Number:9000-0581. Compatible with the IPDACT Internet Communicator Specifications Ordering Information Operating Voltage: 24 VDC(from the PM-9/PM-9G Part Number Description power supply) DACT-E3 Digital alarm communicator transmitter Operating Current: 0.018 amp Alarm Current: 0.018 amp An ISO 9001-2000 Company Operating Temperature: 32°to 120° F (0 to 49° C) SIGNALING Relative Humidity: 0 to 93%, non-condensing at 90° F(32° C) u� ®MEA11j Clt,.°f Chicago City of APPROVED De R LISTED 3025415 ApprovedFDNY: 7165.1703:012SApproved Approved r E3 Series®and NetSOLO�are registered traderr�rics of Ha,eywell International Inc. COA#5077 UL®is a registered trademark of Underwiters laboratories Inc. High RIs. GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 Specifications are for information only,are not intended for installation purposes,and are subject to change without notice.No responsibility is assumed by Gamewell-Fa for their use. �� 011 byHa,eywell International Inc. al rights reserved. www.gamewell-fci.com 9020-0610 Rev. I page 1 of 1 Gamewell pm_g CI FCI INS FIRE TRUMENTS CONTROL by Honeywell Description PM-9 Power Supply The Gamewell-FCI, PM-9 Power Supply is a switching power supply that provides 9 amperes of filtered and regu- lated 24 VDC (nominal). It provides the power to the INX . —_ 4 j ,� PNOWCTio .. Y'- 0_ Transponder assembly and all of the E3 Series compo- - ,� _ •��. ',`'. nents. It is a component of the followingsystems. `"H" - S • E3 Series®Expandable Emergency Evacuation System 0,,...�- I. ,f' III -J-L'ie—.'=� • E3 Series Combined Fire and Mass Notification System • E3 Series Broadband Voice Evacuation System I .;i'2,. w_ ...: w , '�*I- : • • NetSOLO®System ,i1 `_• �=- ��. _ ' g.I. `-4, ��,_ -. R. The PM-9 has an internal battery charging circuit capable Ii .$'•=-i.^��- ;"' ,.::-.61i - : - lM� of maintaining up to 55 NH batteries. This module is 4 I'' - ";'.,1:''' designed for use with the Gamewell-FCI distributed audio ~x $ networks. PM-9 Installation Typically, the PM-9 Module can be mounted in the follow- Features ing E3 Series cabinets: • Cabinet B and D, backbox • Cabinet C, INX-E3 sub-assembly plate • Listed under UL®Standard 864, 9th Edition. • Cabinet C, INCL E3 sub assembly plate • Listed under UL Standard UL2572 for Mass • Cabinet D, E3-INX-D Plate • Cabinet D, E3-ILI-D Plate Notification. • For information on the installation of the PM-9, refer to the Includes 9 ampere, filtered, regulated power following documents: supply. • E3 Series Expandable Emergency Evacuation • Provides 1 ampere battery charging current. Installation/Operating Manual, P/N: 9000-0574 • Offers energy and space saving switching • PM-9 Installation Instructions, P/N: 9000-0548 technology. • Mass Notification System Manual, P/N:LS10013-000GF-E • Contains an integral battery charger capable of Specifications recharging up to 55 AH batteries. (Batteries not furnished). Input Voltage: 120 VAC 60 Hz @ 3.5 A. max. Ordering Information Output Voltage: 24 VDC(nominal) FWR Output Current: 9 amperes Part Number Description Output Current: 1 ampere battery charging PM-9 Power supply current Alarm Current: 0.050 amp 29229 AC Line Filter Kit Operating Temperature: 32°to 120° F(0°to 49° C) Relative Humidity: 0 to 93% (non-condensing)at 90° F(32° C) Dimensions: 10 1/2"W x 5" H x 2" D mum (27x13x5cm) SIGNALING03,4 Ci of ® ® �L FM MEAof Chicago DENCiVER E3 Series and NetSOLO are registered trademarks of i-loneywell International Inc. LISTED APPROVED Approved t� Approved Approved UL®is a registered trademark of Underwriter's Laboratories Inc. S1669 Vd.14 3017416 FDNY: 7165-1703:0125 Class 1 S1949 Vd.19 COA#6077 Class 2 High Rise ISO 9001 =memo GAMEWELL-FCI PIIGIIIY SYSTEMS 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 Specifications are far information only,are not intended far installation purposes,and are subject to change without notice.No responsibility is assumed by Gamewell-Fa for their use. 2o13byHoneywell International Ina al rights r . www.gamewell-fci.com 9020-0555 Rev.0 page 1 of 1 Gamewell HPFF12 FEiFIRE TRUMENTS CONTROL INS by Honeywell Description Notification Appliance Circuit (NAC) The Honeywell HPFF12 and HPFF12CM are Notification Expander Power Supply Appliance Circuit (NAC) Expander Power Supplies designed to extend the power capabilities of existing NACs and provide power for auxiliary devices. The HPFF12 con- nects on nects to any 12 or 24V Fire Alarm Control Panel (FACP)or L+'"'' stand alone panel. It is available in 12.0 amps and provides regulated and fil- _ '.•' ' tered 24VDC power to four NACs and an auxiliary output. The NAC outputs are rated at 3.0 amps each and the auxil- . , iary output is rated at 2.0 amps (this output is continuously • - supplied, even in alarm, and therefore must be taken into account for power supply loading and battery size calcula- tions). The combined output cannot exceed 12.0 amps. The HPFF12 provide independent output circuit supervi- I PFF12 sion so that in the event of an NAC fault they can notify the Features attached FACP. In addition, they have a trouble memory • Complies with UL®Standard 864 9th Edition feature that displays past troubles (by NAC)for rapid diag • Four(4)Class 2 power limited, supervised notification nostics. Synchronization is built-in for five appliance application circuits(NACs)capable of supplying brands. The HPFF12 has two fully independent supervised +24VDC at 3.0 amp maximum each initiating circuits that can be used for synchronized strobes • NAC output circuits may be configured as any ofthefdlowing: and coded horns. - Four Class B (Style Y). -Two Class A(Style Z). The NAC outputs may be configured as any of the follow- -Two Class B&oneClassA -Four Class A(requires the ing: HPP31076 Class A adapter). • Four Class B(Style Y) • Two Class B and one Class A • Four field-programmable operational modes: • TWD aassA(Style Z) • Four Class A with the optional -Pass-through -Sync generator HPP31076 Class A adapter installed -Temporal generator - Pass-through Filtered These power supplies contain an internal Battery charger • Temporal coding and sync protocols compatible with capable of charging up to 26.0 amp-hour (AH) batteries. the following notification appliance brands: The HPFF12 is mounted in a lockable wall cabinet that can -System Sensor -Amseco accommodate up to two 18AH batteries. - Faraday -Cooper-Wheelock The HPFF12CM is designed to mount in a large lockable -Gentex equipment enclosure (CAB-4; order separately). Up to • Protocol pass-through for synchronizing large systems three HPFF12CM power supplies can be mounted in a • Two fully independent supervised input/output control EQBB-D4, in positions 2, 3, and 4. Each HPFF12CM circuits accommodates two 12AH batteries. • Redundant activation operation for survivability One of the most challenging aspects of a retrofit application • Supports FACP's Selectable Silence ability is locating the existing End-of-Line (EOL) resistor value. In • 2.0 amp auxiliary continuously supplied output retrofit applications that do not have the standard 3.9k EOL • Eight status LEDs resistor value, the HPFF12 uses a single resistor that • Supervised AC input, battery voltage, auxiliary output, matches the existing EOL and can be used as a reference charger, and earth ground faults for all the outputs.This feature speeds installation and sys- tem checkout, because the actual EOL does not need to be located and changed in the circuit. The reference resistor SIGNALING value must be within the End-of-Line resistor range of 1.9k to 25k. Lb) UL®is a registered trademark of Underwriters Laboratories Inc LISTED APPROVED S24562 7315-1637:0102 (ISO 9001 GAMEWELL-FCI MINHAINC QUALITY SpYSTEMYS 12 Clintonville Road,Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 Specifications are far information only,are not intended for installation purposes,and are subject to change without notice.No responsibility is awl Inad by Gamewell-Fa far their use. 2O13byF-biel International Inc. wlrights reserved. www.gamewell-fci.com 9021-60628 Rev.C page 1 of 2 Specifications Features (Continued) • Trouble indication for supervision of the following: Primary Input Power: 120VAC, 60Hz, 5.4A; - NAC circuits -Battery charger voltage 240VAC, 50Hz, 3.2A on -Auxiliary output -Earth ground faults units with E suffix Secondary Power: 24 volt operation: -AC input two(2), 7-24 AH batteries • Optional two-hour delay for AC loss Battery Charging Capacity Up to 26 AH batteries • Separate Trouble and AC Fail Form-C relay contacts HPFF12 Cabinet: Holds up to two 18AH • The Trouble Form-C relay contacts selectable for batteries immediate or a 2 hour delay with AC failure HPFFI2CM: Holds up to two 12AH • 26 AH battery charger capability; wall cabinet supports batteries two 12V 18AH batteries, while the Multi-pack equip- Total Output Current: 12.0A max. ment cabinets supports two 12V 12AH batteries Standby Current: 0.075 A • NAC Overload protection and indication Auxiliary Power Output: 2.0A under all conditions • Provision for mounting single (AOM-2SF) or 6 circuit NAC Output Ratings: 24VDC fully regulated 3.0A addressable control (MMO-6SF) or relay modules max per circuit(12.0A total) (AOM-2RF)inside the enclosure. End-of-Line Resistor 1.9K to 25k ohm, % watt. (Use mounting kit P/N:90474). Range: Product ships with 4 sepa- rate programming resistors. Ordering Information They are 3.9K(5 each-only need one for programming), Part Number Description 2.2K(1 each),4.7K(1 each) HPFF12 12.0A fire rated power supply. Unit and 10K(1 each) includes red enclosure, battery cable Common Trouble: 2.0A at 30VDC and installation instructions. Relay Fail Relay: 2.0A at 30VDC 120VAC/60Hz Input Control Circuits: Compatible with 12 and 24 HPFFI2E 240VAC/50Hz version of HPFF12 VDC control panel NACs HPFFI2CM 12.0A fire rated power supply(chassis Input Control Current 5.68 mA @ 12VDC, mounted). Unit includes mounting hard- (alarm): 12.28 mA @ 24 VDC ware, battery cable and instructions for Temperature Rating: 32°F to 120°F(0°C to 49°C) installation in a large equipment enclosure. 120VAC/60Hz Relative Humidity: 10%to 93% non-condensing HPFFI2CME 240VAC/50Hz version of the Cabinet Dimensions: HPFF12CM HPFF12 Cabinet: 16.65"W x 19.0" H x 5.2"D HPP31076 Class A(Style Z)NAC Adaptor. Increase (42.29 Wx 48.26 H x 13.23 D cm) Class A circuits from 2 to 4 CAB-4 Cabinet: 24"W x 45.9" H x 5.15" D FCI-VDR-D4B Louvered door with PK-625 lock and key (60.96 Wx 116.52 Hx 13.1 Dam) for EQBB-C4 or EQBB-D4 backbox Figure 1 illustrates the HPFF12CM power supply. EQBB-C4 CAB-4 backbox enclosure for up to two (2) HPFF12CM power supplies EQBB-D4 CAB-4 backbox enclosure for up to . Iii. three(3) HPFF12CM power supplies I MMO-6SF Six-circuit supervised addressable con- 1 trol module activated through FACP pro- fgramming on a select basis to control 11 ,-� power supply activation or output _ *', AOM-2SF Supervised addressable control module — activated through FACP programming to activate power supply 90474 Mounting kit; required to attach an • addressable module onto the control cir- • ;" cuit board (included with power supply) 17070 Replacement PK-625 lock for HPFF12 cabinet - ' ' 2400-0002 Replacement key for HPFF12 cabinet Jam: Figure 1 I-FFF12CM Enclosed in the E013B-D4 Cabinet GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 9021-60628 Rev.C page 2 of 2 www.gamewell-fci.com Gamewell Velociti® Series FIRECONTROL ASD-PL2F, ASD-PTL2F by Honeywell and ASD-PL2FR Description Analog, Addressable Photoelectronic Smoke Sensor The Gamewell-FCI Velociti® Series, analog address- able plug-in smoke sensors with integral communica- tion provide features that surpass conventional sensors. Sensitivity can be programmed in the con- trol panel software, and is continuously monitored and reported to the panel. Point ID capability allows " each sensor's address to be set, providing exact locations for selective maintenance when the cham- ber contamination reaches an unacceptable level. ASD-PL2FASD-PTL2F ASD-PL2FR The ASD-PL2F photoelectric sensor's unique optical sensing chamber is engineered to sense smoke pro- Features duced by a wide range of combustion sources. Dual electronic thermistors add 135°F (57°C) fixed-tern- • Sleek, low-profile design perature thermal sensing on the ASD-PTL2F model. • Visual rotary, decimal switch addressing (01-159) • Built-in functional test switch activated by an external The Velociti® Series use a communication protocol magnet that substantially increases the speed of communica- • Bicolor LEDs flash green whenever the sensor is tion between the sensors and certain Gamewell-FCI addressed,and light steady red on alarm* analog addressable fire alarm controls. These • devices operate in a grouped fashion. If one of the Optional relay, isolator, or sounder bases • devices in the group has a status change, the panel's Low standby current microprocessor stops the group poll and concen- • Analog addressable communication trates on the single device. The net effect is a • Stable communication technique with noise immunity response speed up to five times greater than earlier • Optional remote, single-gang LED Indicator(RA100Z) designs. • Compatible with Gamewell-FCI analog addressable panels Ordering Information Note:*Only the red LED is operative in panels that do not operate in Velociti®mode. Model Description ASD-PL2F Analog, addressable photoelectronic smoke sensor ASD-PTL2F Analog, addressable photoelectronic smoke sensor with thermal sensing ASD-PL2FR Analog, addressable photoelectronic smoke sensor used with the DNR duct base when An ISO 9001-2000 Company the remote test is required. SIGNALING PIM Velociti®is a registered trademark of Honeywell International Inc. ® ® MEA UL®is a registered trademark of U derwriters Laboratories Inc. LISTED APPROVED ApprovedEVo r S1913 3023594 21302-EVd.VI 7272-1703:0121 GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1653 USA•Tel:(203)484-7161 •Fax:(203)484-7118 Specifications are for information only,are not intended for installation purposes,and are subject to change without notice.No responsibility is assumed by Gamewell-FG for their use. �©2011 byhbneywell International Ina All rights reserved. www.gamewell-fci.com 9020-0617 Rev. I page 1 of 2 Installation Specifications ASD-PL2F plug-in sensors use a separate base to ASD-PL2F, ASD-PTL2F, ASD-PL2FR: simplify installation, service, and maintenance. A Dimensions: 2.1" (5.1 cm)height special tool allows maintenance personnel to plug-in Diameter: 4.1" (10.4cm)installed in the B501 base and remove sensors without using a ladder. 6.1" (15.5 cm)installed in the B210LP base Shipping Weight:5.2 oz. (147 g) Mount the base on a box which is at least 1.5" (3.8cm) Operating ASD-PL2F: deep. Suitable mounting base boxes include: Temperature: 32° F to 120° F(0° C to 49° C) ASD-PTL2F: • 4.0" (10.2 cm)square box 32° F to 100° F(0° C to 38° C) • 3.5" (8.9 cm)or 4.0"(10.2 cm)octagonal box UL®-Listed 0-4000 ft./min. (1,219.2 m/min.), • Single-gang box(except relay or isolator bases) Velocity Range: suitable for installation in ducts. • With B200S or B200SR base, mounted on a 4.0" Relative 10-93% (non-condensing) (10.2cm)octagonal or square box Humidity: • With B224RB or B224B1 base, mounted on a 3.5" Thermal Ratings: Fixed-temperature setpoint 135° F(57° C) (8.9 cm)octagonal box, ora 4.0"(10.2 cm)octagonal or square box Electrical Specifications NOTE: Because of the inherent supervision provided Voltage Range: 15-32 volts DC peak by the SLC, end-of-line resistors are not required. Standby Current: (max.avg.): .0003 A @ 24 VDC Wiring "T-taps" or branches are permitted for Style 4 (one communication every 5 (Class "B")wiring. seconds with LED blink enabled) Maximum Alarm- Current: .0065 A @ 24 VDC(LED)lit). Sensor Spacing Gamewell-FCI recommends that the spacing sensors Bases and Options be used in compliance with NFPA 72. B501 Plug-in sensor base without flange Dimensions: 4.1" (10.4 cm)diameter B210LP Flanged mounting base Dimensions: 6.1" (15.5cm)diameter B210LPBP Flanged mounting base bulk pack Dimensions: 6.1" (15.5cm)diameter B224RB Plug-in sensor base with auxiliary Relay Base relay, SPDT, rated 2 amps @ 30 VDC (resistive) Screw terminals: Up to 14 AWG (2.0 mm2) 2 coil latching relay 1 Form C contact UL/CSA Rating: 0.9 A @ 125 VAC, inductive 0.9 A @ 110 VDC, inductive 3 A @ 30 VDC, resistive Dimensions: 6.1" (15.5cm)diameter Maximum: 25 devices between isolator bases. B200S Intelligent sensor sounder base Dimensions: 6.875"(17.5 cm)diameter B200SR Standard sounder base, UL 8649th Edition compliant, ULC Listed Dimensions: 6.875"(17.5 cm)diameter RA100Z Remote LED Annunciator BCK-200 Black detector covers(box of 10) DNR Duct smoke housing GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1653 USA•Tel:(203)484-7161 •Fax:(203)484-7118 9020-0617 Rev. I page 2 of 2 www.gamewell-fci.com ameweiiVelociti Series FeFIRE TRUMENTS CONTROL ' INS AMM-21F by Honeywell Description Addressable Dual Monitor Module The Gamewell-FCI Velociti® Series, addressable dual monitor module, AMM-21F, features two (2), Style B, Class e • B initiating device circuits, each with an end-of-line resistor. This module provides addresses for any device or group of devices connected to each circuit. Any alarm initiating devices with normally open (N.O.) dry contacts, such as heat detectors, 4-wire projected beam smoke detectors, 4- _ wire smoke detectors, water flow switches, tamper switches, manual stations, etc. may be installed in these circuits. AMM-21F Features The Velociti® Series use a communication protocol that substantially increases the speed of communication • Compact size allows easy installation between the sensors and certain Gamewell-FCI analog • addressable fire alarm controls.These devices operate in a Class B, Style B, initiating device circuits grouped fashion. If one of the devices in the group has a • Visual rotary, decimal switch addressing (01-159) status change, the panel's microprocessor stops the group • 40 ohm line resistance for each initiating circuit poll and concentrates on the single device.The net effect is • Accommodates any normally open contact device response speed up to five times greater than earlier • Bicolor LEDs flash green whenever the module is designs. addressed,and light steady red on alarm* *Note: Only the red LED is operative in panels that do not operate The first circuit address is set via a rotary switch. The sec- in Velociti®mode. and circuit is automatically assigned the next higher address. The module has a single panel-controlled red Specifications LED. Supervisory current: 0.0075 amp. The AMM-21F module is designed for installation in the sig- Alarm current: .0057 amp. (LED lit) naling line circuit of any Gamewell-FCI addressable control Operating temperature: 32°to 120° F(0°to 49° C) panel. The AMM-21F is designed to mount in a 4" square Relative humidity: 10 to 93% (non-condensing) junction box, 2 1/8"deep.The initiating device circuit of the Dimensions: 4 1/2" H x 4"W x 1 1/4" D AMM-21F can support a maximum line resistance of up to (11 Hx 10.2Wx3Dcm)(Mounts in a 4" 40 ohms allowing the use of linear heat detection devices. square by 21/8"deep box). End-of-line resistor: 47 K ohms Ordering Information Model Description AMM-2IF Monitor module,two circuit, Style B, Class B SIGNALING Velociti®and E3 Series°are registered trademarks of Honeywell UL ® MEA International Inc. LISTED APPROVED Approved S1949 3023594 227-03-EVd.IV 7300-1703:0107 ISO 9001 GAMEWELL-FCI QUALITY s"arEm"5 12 Clintonville Road,Northford,CT 06472-1653 USA•Tel:(203)484-7161 •Fax:(203)484-7118 Specifications are far information only,are not intended far installation purposes,and are subject to change without notice.No responsibility is assumed by Gamewdl-Fa for their use. ©2013 Honeywell International Inc. Alltights reserved. www.gamewell-fci.com 9020-0629 Rev. E page 1 of 1 I � Gamewell Velociti® S FIRE CONTROL INSTRUMENTS AOM-2SF by Honeywell Description Addressable Output Relay Supervised Control Module The Gamewell-FCI Velociti® Series addressable output __ supervised control module (AOM-2SF) allows a i^• A� • 1, Gamewell-FCI analog addressable fire alarm control panel 4 to switch an external power supply,such as a DC supply or """" _ © audio amplifier (up to 80 VRMs) to notification appliances. _ + The AOM-25F notification appliance circuit can be wired �•w .�.. either Class A(Style Z)or Class B (Style Y). It also super- _ qb vises the wiring to the connected loads and reports their status to the panel as NORMAL, OPEN or SHORT ik ♦ I P CIRCUIT.The module contains a panel controlled LED. AOM-2SF The Velociti® Series use a communication protocol that Features substantially increases the speed of communication between the SLC devices and certain Gamewell-FCI ana • Listed under UL®Standard 864 and UL2572 for Mass log addressable fire alarm control panels. These devices Detifon. • Designed as a compact size to allow easy installation. operate in a grouped fashion. If one of the devices in the • Includes Class A,Style Z,or Class B,Style Y notification group has a status change, the panel's microprocessor appliance circuit. stops the group poll and concentrates on the single device. • Accommodates audio amplifiers up to 80 VRMs. The net result is a superior response speed up to five • FM Listed as suitable for a releasing device service. times greater than the earlier designs. • Includes a bicolor LED that flashes green whenever the module is addressed, and lights steady red upon The AOM-25F module is designed for installation in the activation*. signaling line circuit of any Gamewell-FCI analog address- *Note: Only the red LED is operative in panels that do not operate in able fire alarm control panel. The signaling line circuits of Velociti®mode. Gamewell-FCI analog addressable fire alarm control pan- els are designed to accommodate up to 159 modules per Specifications circuit. The AOM-2SF is designed to mount in a 4" (10.16 cm)square junction box 2 1/8"(5.5 cm)deep. Supervisory Current: .000375 amps Table 1 lists the relay contact ratings. Alarm Current: .0065 amps Current Maximum Load Operating Temperature: 32°to 120° F(0°to 49°C) Rating Voltage Description Application Relative Humidity: 10 to 93% relative humidity 3A 30 VDC Resistive Non-Coded (non-condensing) 2A 30 VDC Resistive Coded Dimensions: 4 1/2"H x 4"W x 1 1/4" D 0.9A 110 VDC Resistive Non-Coded (11.4 H x 10.2 W x 3.2 D cm) 0.5A 125 VAC Resistive Non-Coded Ordering Information 0.5A 30 VDC Inductive (L/R=5ms) Coded 1A 30 VDC Inductive(L/R=2ms) Coded Part Number Description AOM-2SF Addressable output supervised 0.5A 125 VAC Inductive(PF=.35) Non-Coded 0.7A 75 VAC Inductive Non-Coded control module SIGNALING Table 1: Relay Contact Ratings Velociti®is a registered trademark of Honeywell International Inc. L ® MEA sOa a®is a registered trademark of Underwriters Laboratories Inc. LISTED APPROVED Approved •' S1949 3023594 227-03-E VoI.IV 7300-1703:0102 iso 9001 GAMEWELL-FCI ENGINEERING QUALITY SYSTEMS MANUFACTURING SEES12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 Specifications are for information only,are not intended for installation purposes,and are subject to change without notice.No responsibility is assumed by Gamewell-FCI for their use. ©2014 Honeywell International Inc. All rights reserved. www.gamewell-fci.com 9020-0627 Rev.G page 1 of 1 Gamewell Velociti Series mi FCI INS FIRE TRUMENTS CONTROL AO M-2R F by Honeywell Description Addressable Output Relay Control Module The Gamewell-FCI Velociti® Series, addressable output , relay control module (AOM-2RF) allows an Gamewell-FCI 4, • % I* analog addressable fire alarm control to switch discrete relay contacts by code command. The relay provides two iu . o (2), isolated sets of Form-C contacts which transfer simul- taneously. Circuit connections to the relay contacts are not supervised by the module. The Velociti® Series use a communication protocol that 46 • substantially increases the speed of communication .^ _ - between the sensors and certain Gamewell-FCI analog addressable fire alarm controls.These devices operate in a ACN1-2RF grouped fashion. If one of the devices in the group has a Features status change, the panel's microprocessor stops the group poll and concentrates on the single device.The net effect is response speed up to five times greater than earlier • Two(2)sets of Form"C"contacts designs. • Visual rotary, decimal switch addressing (01-159) • Bicolor LEDs flash green whenever the sensor is The AOM-2RF Module is designed for installation in the addressed, and light steady red on alarm* signaling line circuit of any Gamewell-FCI analog address- able fire control panel. The module contains a panel con- • trolled LED. The AOM-2RF is designed to mount in a 4" Note: Only the red LED is operative in panels that do not operate square junction box 2 1/8"deep. in Velociti®mode. Specifications Relay Contact Ratings Supervisory current: .000375 amps. Current Maximum Load Alarm current: .0065 amps. Rating Voltage Description Application Operating temperature: 32°to 120° F(0°to 49° C) 3A 30 VDC Resistive Non-Coded Relative humidity: 10 to 93% relative humidity 2A 30 VDC Resistive Coded (non-condensing) 0.9A 110 VDC Resistive Non-Coded Dimensions: 4 1/2" H x 4"W x 1 1/4" 0.5A 125 VAC Resistive Non-Coded (11.4x 10.2 x3.2 cm) 0.5A 30 VDC Inductive Coded Ordering Information (L/R=Sms) 1A 30 VDC Inductive Coded Model Description (L/R=2ms) AOM-2RF Addressable output relay control module 0.5A 125 VAC Inductive Non-Coded (PF=.35) An ISO 9001-2000 Company 0.7A 75 VAC Inductive Non-Coded SIGNALING Velociti®Series is a registered trademark of Honeywell International Inc. ® ® MEA I LISTED APPROVED Approved I S1949 3023594 227-03EVd.IV 073060694178 GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1653 USA•Tel:(203)484-7161 •Fax:(203)484-7118 Specifications are for information only,are not intended for installation purposes,and are subject to change without notice.No responsibility is assumed by Gamewell-FG for their use. x©2011 Honeywell Intematicnal Inc. Al rights reserved. www.gamewell-fci.com 9020-0625 Rev. D1 page 1 of 1 GameweII Velociti® Series FIRE CONTROL ' INSTRUMENTS B200sR_LF by Honeywell Description Low Frequency Intelligent The Gamewell-FCI, B200SR-LF sounder base sets a new Sounder Base standard for performance, installation and aesthetics. The B200SR-LF low frequency sounder base is designed to comply with the NFPA 72 sleeping space requirement to produce a fundamental frequency of 520 Hz+/ 10%with a - • square wave or its equivalent. Studies show that a lower frequency, centered around 520 Hz, is the ideal frequency _ • to awaken sleeping occupants, even those occupants with mild to severe hearing loss. In addition, it offers maximum j flexibility in installation, configuration and operation to com- cix k ))) ply or exceed the UL Standards 268 and 464 requirements. ` ' U • F The B200SR sounder base is compatible with the B501 BH • Series sounder base installations. By removing the jumper, the device enables users to select one of two B501-sup- ported tones(ANSI Temporal 3 or Continuous). Installation --- The sounder base offers the following installation features: B200SR-LF • Pre-wired mounting plate that fits various junction box sizes. Features • The housing locks to a mounting plate with two retaining screws to prevent tamper resistance. • Complies with UL Standard 464 for 520 Hz. low Specifications frequency. • Complies with UL Standard 268. Physical Specifications: • Supports 520 Hz+/- 10%square wave tone. Base Diameter: 6.875"(17.46 cm) • Includes a tone selection via an onboard jumper. Base Height: 2.0"(5.08 cm)less sensor • Compatible with the B501 BH-Series sounder base Shipping Weight: 0.60 lb.(272 gm) installations. Operating For applicable sensor Operat- • Includes a pre-wire mounting plate that fits various Temperature Range: ing Temperature Range, refer junction box sizes. to the Base/Sensor Cross Ref- • Offers a mechanical locking feature that prevents the erence Chart at the link: removal of an attached sensor head. www.systemsensor.com Operating Humidity 10%to 93% relative humidity Range: (non-condensing) Ordering Information Electrical Specifications: External Supply Voltage: 16 to 33 VDC(VFWR) Part Number Description External Supply Standby B200SR-LF Low Frequency Intelligent Current: 1 mA maximum Addressable Sensor Sounder Base Alarm Current: 65 mA max. @ 33.0 VDC 90 mA max. @ 24.0 VDC Note: The B2�00SR-LF sounder base is compatible with sR 125 mA max. @ 16.0 VDC the E3 Serieand S3 Series TM fire alarm control panels. SLC Operating Voltage: 15 to 32 VDC SLC Standby Current: Refer to applicable sensor specification Sound Output: High Volume: Greater than 85 dBA minimum measured in a UL reverberant room at 10 ft. 24 Volts(in con- SIGNALING tinuous tone) E3 Series is a registered trademark and the S3 SeriesTM is a trademark of Honeywell Inter120 - national Inc. LISTED UL®is a registered trademark of Underwriters Laboratories Inc. S1911 (ISO 9001 GAMEWELL-FCI "UALITY SYSTEMS YS°TURING EMS 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel: (203)484-7161 •Fax: (203)484-7118 QUALITY sysrFrws Specifications are for information only,are not intended for installation purposes,and are subject to change without notice.No responsibility is assumed by Gamewell-FCI for their use. ©2014 by Honeywell International Inc. All rights reserved. www.gamewell-fci.com 9021-60843 Rev.A page 1 of 1 Gamewell Velociti® Series FIRE CONTROL Fei INSTRUMENTS ATD-L2F, AID-H L2F by Honeywell Description Addressable Thermal Sensor The Gamewell-FCI Velociti® Series, addressable plug-in thermal sensors with integral communication provide fea- tures that surpass conventional sensors. Point ID capabil- ity allows each sensor's address to be set, providing exact locations for pinpointing alarm locations and for selective maintenance. ATD thermal sensors use an innovative thermistor sensing circuit to produce 135°F/57°C fixed- temperature (ATD-L2F). The ATD-RL2F provides a combi- nation 15°/minute rate-of-rise with 135° fixed thermal detection that is included in a low-profile package. The ATD-HL2F provides fixed high-temperature detection at 190°F/88°C.These thermal sensors provide cost-effective, addressable property protection in a variety of applica- tions. ATQL2F The Velociti® Series uses a communication protocol that substantially increases the speed of communication between the sensors and Gamewell-FCI analog address- Features able fire alarm controls. These devices operate in a grouped fashion. If one of the devices in the group has a • Sleek, low-profile design status change, the panel's microprocessor stops the group • Visual rotary switch addressing poll and identifies the single device with the status change. The net effect is response speed up to five times greater • Built-in functional test switch activated by an external than earlier designs. magnet Installation • Bicolor LEDs flash green whenever the sensor is ATD plug-in sensors use a separate base to simplify instal- addressed, and light steadily red on alarm* lation, service, and maintenance. A special tool allows • Optional relay, isolator, or sounder bases maintenance personnel to plug-in and remove sensors without using a ladder. • Low standby current • Addressable communication Mount the base on a box which is at least 1.5" (3.8 cm) deep. Suitable mounting base boxes include: • Stable communication technique with noise immunity • 4.0"(10.2 cm)square box. • Optional remote, single-gang LED accessory • 3.5"(8.9 cm)or 4.0" (10.2 cm)octagonal box. (RA-100Z) • Single-gang box(except relay or isolator base). • Suitable for installation in ducts • With B200S or B200SR base, mounted on a 4.0" (10.2 cm)octagonal or square box. Note:"Only the red LED is operative in panels that do not operate • With B224RB or B224B1 base, mounted on a 3.5"(8.9 in Velociti®mode. cm)octagonal box, or a 4.0"(10.2 cm)octagonal or square box. NOTE: Because of the inherent supervision provided by the SLC, end-of-line resistors are not required. Wiring "T- An ISO 9001-2000 Company taps"or branches are permitted for Style 4 (Class"B") wiring. SIGNALING Velociti®and E3 Series®are registered trademarks of Honeywell International Inc. ® ® MEA UL®is a registered trademark of Underwriters Laboratories Inc. LISTEDAPPROVED Approved ULC°is a registered trademark of Underwriters Laboratories Canada Inc. 23323023594 219-02-E Vol.VI 7270-1703:0115 GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 Specifications are for information only,are not intended for installation purposes,and are subject to change without notice.No responsibility is assumed by Gamewell-FG far their use. �©2011 by Honeywell International Inc. All rights reserved. www.gamewell-fci.com 9020-0620 Rev. E page 1 of 2 Specifications Specifications ATD-L2F/ATD-RL2F Bases and Options Dimensions: 2.1" (5.3cm)Height B501 Plug-in sensor base without flange 4.1" (10.4cm)diameter installed in Dimensions: 4.1"(10.4 cm)diameter the B501 base B210LP Flanged mounting base 6.1" (15.5cm)diameter installed in Dimensions: 6.1"(15.5cm)diameter the B210LP base B210LPBP Flanged mounting base bulk pack Shipping Weight: 4.8 oz. (137 g) Dimensions: 6.1"(15.5 cm)diameter Operating B224RB Plug-in sensor base with auxiliary relay, Temperature: SPDT ATD-L2F or 2 coil latching relay 1 Form C contact UL/ ATD-RL2F —4° F to 100° F(-20° C to 38°C) CSA Rating: ATD-HL2 —4° F to 150°F (-20 C to 66°C) 0.9 A @ 125 VAC (inductive) Sensor Spacing: UL®approved for 50 ft. (15.2 m) 0.9 @ 110 VDC(inductive) center to center 3.A @ 30 VDC (resistive) FM approved for 25 x 25 ft. Dimensions: 6.1"(15.5cm)diameter (7.6 x 7.6 m)spacing B224B1 Plug-in sensor isolator base for Style 7 Relative Humidity: 10—93%(non-condensing) operation ATD-L2F Fixed-temperature setpoint Dimensions: 6.1"(15.5cm)diameter 135°F (57°C) Maximum 25 devices between isolator ATD-RL2F Combination 135° F fixed bases temperature and 15° F(8.3°c)/per B200S Intelligent sensor sounder base minute rate-of-rise° Dimensions: 6.875" (17.5 cm)diameter ATD-HL2F Fixed-temperature setpoint B200SR Standard sounder base, UL 864 9th 190°F (88°C) Edition compliant, ULC Listed Dimensions: 6.875" (17.5 cm)diameter RA-100Z Remote LED Annunciator Electrical Specifications BCK-200 Black detector covers(box of 10) Voltage Range: 15-32 Volts DC peak Ordering Information Standby Current: 200 mA @ 24 VDC (without communication) (max.avg.) .0003 A @ 24 VDC Part Number Description (one communication every 5 seconds ATD-L2F Addressable thermal sensor,fixed, 135° F with LED blink enabled) ATD-RL2F Addressable thermal sensor, combination LED Current fixed,135° F and 15°/minute rate-of-rise. (max.) .0065 A @ 24 VDC(LED lit) ATD-HL2F Addressable thermal sensor,fixed, 190° F GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 9020-0620 Rev.E page 2 of 2 www.gamewell-fci.com Gamewell Velociti®Series FCI INSTRUMENTSL mes_coF by Honeywell Description Advanced Multi-Criteria Fire/CO Detector The Advanced Multi-Criteria Fire/CO Detector(MCS- COF)is an addressable device that provides both fire and carbon monoxide (CO) detection. For fire detec- tion, the detector combines the following four sepa- rate sensing elements in one unit. r� • Smoke • Carbon Monoxide (CO) • Light/flame • Heat f These elements sense multiple components of a fire. • / This approach enables an enhanced sensitivity to 1111, real fire with a heightened immunity to nuisance par- ticulate. For CO, the detector's electrochemical sens • - ing cell creates a separate signal for life safety CO • detection. - Released through the incomplete burning of various fuels, CO is a colorless, odorless and deadly gas that is virtually impossible to detect with the human MCS-COF in a B200S Sounder Base senses. Because the potential exists for dangerous levels of CO to accumulate in almost any building, Features legislation mandates the use of CO detection in com- mercial spaces in the U.S. The MCS-COF is Listed to the UL® 2075 Standard for system-connected life • Offers the unique function to detect the following safety carbon monoxide monitoring. four major elements of a fire: It is designed to be used with the Gamewell-FCI, E3 - Smoke - Carbon Monoxide (CO) Series or S3 Series fire alarm control panel only. The - Light/flame - Heat MCS-COF should be used in conjunction with the • Supplies a separate CO detection signal. B200S intelligent sounder base, which can generate • Presents the highest nuisance alarm immunity. either of the following patterns: • Produces an automatic drift compensation of • Temp 3 pattern for fire. smoke sensor and CO cell. • Temp 4 pattern for CO alarm indication. • Uses only one address on the SLC. The B200S recognizes the System Sensor synchro- • Includes the EasyTest CO testing capability. nization protocol. This feature enables it to be used • Complies with UL®Listed Standard 268 and UL® as a component of the general evacuation signal, Listed Standard 2075. along with other System Sensor horns, horn strobes, • Separates the audible signal for fire or CO alarm and chimes, when the MCS-COF is connected to a when used with the B200S Base. power supply or Fire Alarm Control Panel (FACP) • Provides the CO cell end-of-life warning and fault. output that is capable of generating the System Sen- sor synchronization pulses. With each sounder base carrying a unique address, the FACP can then com- mand an individual sounder, or a group of sounders, to activate. The command set from the panel can be tailored to the specific event, allowing selection of SIGNALING PEW volume, tone, and group. For more information on the B200S, refer to Data Sheet P/N: 9021-60671. (1G147 E3 Series®is a registered trademark of Honeywell International Inc. UL®is a registered traderrak of Underwriters Laboratories Inc. LISTED WWI S1195 7275-1703:0175 -1S0 9001GAMEWELL-FCI °"°"`"MANUFACTURING 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 Specifications are for information cnly,are not intended for installation purposes,and are subject to change without notice.No responsibility is assured by Gamewell-FG for their use. �©2013byHoneywell International Inc. AIrights reserved. www.gamewell-fci.com 9021-60708 Rev.C page 1 of 2 Specifications Specifications (Continued) Physical Specifications CO Monitoring UL Standard Reference -Alarm Base Diameter: 6.875"(17.46 cm)installed in a B200S Thresholds are as follows: base Parts per Base Height: 3.46"(8.79 cm)installed in B200S base Million 70±5ppm 150±5ppm 400± 10ppm Shipping Weight: 4.6 oz Detector Color: Ivory Response Material: Bayblend FR110 Time, min. 60-240 10-50 4-15 Operating Note: Per UL Standard 2075,the MCS-COF has been Temperature Range:32° F to 100° F (0° C to 38° C) tested to the sensitivity limits defined in UL Standard 2034. Operating Humidity Range: 15 to 90% relative humidity (non-condensing) Ordering Information Air Velocity: 0 to 4,000 ft/min (0 to 20 m/sec) Electrical Specifications Part Number Description Operating Voltage MCS-COF Advanced Multi-Criteria Fire/CO Range: 15 to 32 VDC Detector Note: Due to the unique nature of this Maximum Standby Current: 300 pA at 24 VDC (no communica- detector, pleaseconsult your Fire Panel Control Panel Manufaacturer for tion every 5 seconds with LED blink the specific model and compatibility. enabled). Accessories: Maximum Alarm BCurrent(LED on): 7.2 mA at 24 VDC 02-0 MAddressable Sounder Base M02-04-01 Detector Test Magnet M02-09-01 Telescoping Test Magnet Sensitivity Settings & Suggested Applications Level 1: 1% per foot(30.48 cm)of smoke. Very clean environments: Used in Laboratories. Level 2: 2% per foot(30.48cm)of smoke. Clean environments: Used in offices. Level 3: 3% per foot(30.48cm)of smoke. Moderately clean environments: Used in hotel rooms, dorm rooms. Level 4: 3% per foot (30.48 cm)of smoke with different algorithm processing and weighting of sensor elements. Used in hotel rooms near a shower, boiler rooms. Level 5: 4% per foot(30.48 cm)of smoke. Used in equipment rooms, kitchens, paint shop. Level 6: Thermal alarm at 135° F (57° C). Warning:After the CO cell has reached the end-of-life,the CO sensor no longer provides life safety protection. How- ever, when the fire detector enters Photo, Thermal, Infra- red (PTIR)mode,the following sensitivities apply: Level 1: 1% per foot(30.48 cm)of smoke.Very clean environments: Used in Laboratories. Level 2: 2% per foot(30.48cm)of smoke. Clean environments: Used in offices. Level 5: 3% per foot(30.48 cm)of smoke. Moderately clean environments: Used in hotel rooms, dorm rooms. Level 6: Thermal alarm at 135° F (57° C). GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1653 USA•Tel: (203)484-7161 •Fax: (203)484-7118 9021-60708 Rev.C page 2 of 2 www.gamewell-fci.com GameweII Intelligent mi Fei INFIRE CONTROL STRUMENTS Bases by Honeywell Description B501 , B224RB, B224B1, and B210LP, The Intelligent Velociti® and CLIPTM mounting bases Mounting Kits, and Accessories and kits provide a variety of ways to install Gamewell-FCI detectors in any application. These . mounting bases are non-addressable and are avail- - able in both the Velociti and Clip protocols. The intel- ligent detectors can be mounted in any of the _. following, depending on the junction box selection .--,.-I.) _ (see Table 1 -Junction Box Selection Guide). 14 • flanged bases • flangeless bases Figure B501 Mounting Rase Figure 2 B210LP Mounting Rase • plastic rings Relay, isolator, and sounder bases can be used to meet local code requirements. Relay bases provide ,i \ ,/ �`\ one Form-C contact relay for the control of auxiliary ] F functions such as door closure and elevator recall. Isolator bases allow loops to continue to operate '.,-i under fault conditions and automatically restore when the fault is removed. Sounder bases are avail- Figure 3B224BIMounting Base Figure 4B224RBMounting Bag= able in a combination temporal 3 and continuous Features tone model. All sounder bases offer the following features. The Intelligent Bases provide a variety of mounting • Complies with UL Standards 268 and 464. options to meet your installation challenges. The • Includes the following three types of bases that bases come in flanged or flangeless versions so that comply with local code requirements: you can mount the bases to a variety of junction - Relay - Isolator boxes. See Table 1 for the Junction Box Selection - Sounder Guide. You can use the SMB600 surface mounting • Offers temporal and non-temporal pattern box to mount the following bases: versions. • B224RB relay base • B210LP relay base Relay Base Feature • B224B1 isolator base • Relay bases provide one Form-C contact relay. Isolator Base Feature Specifications • Isolator bases include data communications lines to operate under fault condition. System Temperature and Humidity Ranges: Installation Features These bases comply with the NFPA requirements for The bases offer the following flexible installation operation at 0°C to 49°C (32°F to 120°F); and at a characteristics. relative humidity(non-condensing)of 85% at 30°C • Has multiple accessory options. (86°F) per NFPA, and 93% ±2% at 32°C ±2°C • Includes an installation mounting kit and (89.6°F ± 1.1°F) per ULCe. However, the useful life accessories for several types of model options. of the system's standby batteries and the electronic • Supports 12-24 AWG gauge wire ranges to components may be adversely affected by extreme provide the bases with flexible installation. temperature ranges and humidity. Therefore, it is • Contains bases that enable quick and secure recommended that the bases and all peripherals be detectorlu in. installed in an environment with a nominal room tem- p g perature of 15°C to 27°C (60°F to 80°F) • Provides SEMS screws for easy wiring connections. SIGNALING Velociti®is a registered traderrcuk&C7ipT^is a trademark of Honeywell International Inc. el • UL®is a registered traderrerk of Undevmiters Laboratories Inc. C.at03f'.41 ULG°is a registered trademark of Underwriters Laboratories of Canada Inc. LISTED I APPROVED S911 3035027 7135-1653:0213 ISO ENGINEERING E MANUFACTURING GAMEWELL-FCI QUALITY SYSTEMS 12 Clintonville Road, Northford,CT 06472-1653 USA•Tel:(203)484-7161 •Fax: (203)484-7118 Specifications are for infonration only,are not intended for installation purposes,and are subject to change without notice.No responsibility is assumed by Cemewell-Fa for their use. C2014HoneywellInternational Inc. All rights reserved. www.gamewell-fci.com 9021-60540 Rev. F page 1 of 2 Temperature Range: Ordering Information For B501, B224RB, B224B1, and B210LP 32°F to 120°F (0°C to 49° C) Intelligent Bases Humidity Range: 10%to 93% RH, Part Number Description non condensing B501 Flangeless mounting base Wire Gauge: Dimensions: 4.1" (10.41 cm)diameter For B224131, B224RB: 14 to 24 AWG B501BP Flangeless mounting base bulk pack Dimensions: 4.1" (10.41 cm)diameter Electrical Ratings B224B1 Isolator base Dimensions: 6.875" (17.462 cm)diameter For B224RB, B224B1: B224RB Relay base Operating Voltage: 15 to 32 VDC (powered by SLC) Dimensions: 6.875" (17.462 cm)diameter Standby Ratings: <500 pA maximum @ 24 VDC B210LP Flanged mounting base Set Time Dimensions: 6.1" (15.5cm)diameter (B224RB only): Short delay: 55-90 mseconds B210LPBP Flanged mounting base bulk pack Long delay: 6 to 9 seconds Dimensions: 6.1" (15.5 an)diameter Reset Time XR2B Detector removal tool (B224RB only): 20 mseconds maximum (T55-127-000 included). Relay XP-4 Extension pole for XR2B Characteristics (5 to 15 ft/1.524 to 4.572 m) (B224RB only): Two-coil Latching Relay T55-127-000 Detector removal head. One Form-C Contact BCK-200B Black detector kit. Ratings (UL/CSA): 0.9 A @ 125 VAC (inductive) WCK-200B White detector kit. 0.9 A @ 110 VDC(inductive) 3.0 A @ 30 VDC(resistive) Mounting Kits and Accessories Part Number Description SMB600 Surface mounting kit,flanged. F110 Accessory retrofit flange ring for B210LP F110BP Accessory retrofit flange ring for the B210LPBP bulk pack of 15. F210 Accessory with a new smaller flange ring for the B210LP. M02-04-01 Detector test magnet. M02-09-00 Test magnet with telescoping handle. Table 1 shows the Junction Box Selection Guide. Table 1: Junction Box Selection Guide 3.5" 4.0" 4.0" 4.0"Square with Single-Gang Octagonal Octagonal Square 3.0"mud ring 50 mm 60 mm 70 mm 75 mm B501 No Yes No No Yes Yes Yes Yes No B210LP Yes Yes Yes Yes Yes No No No No B224B1 No Yes Yes Yes Yes No Yes Yes Yes B224RB No Yes Yes Yes Yes No Yes Yes Yes NOTE:The box depth is contingent on the base and the wire size. For information on applicable local codes for appropriate recommendation, refer to the National Electrical Code. GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1653 USA•Tel: (203)484-7161 •Fax: (203)484-7118 9021-60540 Rev. F page 2 of 2 www.gamewell-fci.com Gamewell MS-i Series Fe' FIRE TCORUMENTSNTROL INS by Honeywell Description Non-Coded, Manual Fire Alarm Stations The Gamewell-FCI, MS-7 Series manual fire alarm sta- tions are available in a wide variety of configurations. The Stations comply with the Americans with Disabilities Act 1 J R E (ADA) 5-lb. maximum pull force requirement. Operating instructions and Braille text are engraved in the handle. All stations have a key lock/reset which is keyed alike with I USIH Gamewell-FCI fire alarm control panels and other manual r PUPLLH OOWN I fire alarm stations. MS-7AF Velociti Addressable Station The MS-7AF Velociti®Series addressable station is a dou- ble action station designed for installation in the signaling line circuit of Gamewell-FCI analog addressable control aGariewell panels. Activation of the station causes its assigned " address to register at the control panel. The door contains I - an LED which flashes green in normal condition and lights MS-7 steady red when the station has been activated.* The sta- tion features screw terminals. Features MS-7ASF Velociti Addressable Station The MS-7ASF Velociti® Series addressable station is a • Addressable stations compatible with all Gamewell-FCI single action station designed for installation in the signal analog addressable fire alarm controls ing line circuit of Gamewell-FCI analog addressable con- trol panels. Activation of the station causes its assigned • Conventional stations suitable for use with any UL® address to register at the control panel. The door contains Listed control panel an LED which flashes green in normal condition and lights steady red when the station has been activated.* The sta- • Both single and double action stations available tion features screw terminals. • Tumbler lock for test and reset keyed alike with The Velociti® Series stations use a communication proto- Gamewell-FCI controls col that substantially increases the speed of communica- tion between the sensors and certain Gamewell-FCI • Surface or semi-flush mounting analog addressable fire alarm controls. These devices operate in a grouped fashion. If one of the devices in the • Shock and vibration resistant group has a status change, the panel's microprocessor stops the group poll and focuses on the single device. The net effect is response speed up to five times greater than • Stations(MS-7LOB)Listed for outdoor applications earlier designs. • Complies with ADA pull force requirements MS-7 Double Action Station *Only the red LED is operative in panels that do not oper- The MS-7 double action station is used with conventional ate in Velociti mode. fire alarm control panels. It features a set of single pole contacts and screw terminals for connection to an initiating circuit. An ISO 9001-2000 Company Velodti®is a registered trademark of Fbneyvtell International Inc. SIGNALING y, UL®is a registered trademark of Underwriter's Laboratories Inc. 0 is a registered trademark of GE Plastics,a subsidiary of General FNI MEA `r s: s l7edricCorrpany LISTED 67�WNII 07150.003t 261 GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 Specifications are for information only,are not intended for-installation purposes,and are subject to change without notice.No responsibility is armed by Gameeell-FG far their use. ©2010 by l-b eywell International Inc. Al rights reserved. www.gamewell-fci.com 9020-0616 Rev. D page 1 of 2 MS-7S Single Action Station Specifications The MS-7S single action station is used with conventional fire alarm control panels. It features a set of single pole Material: Lexan® contacts and wire leads for connection to an initiating drcuit. Contact Ratings: 0.25 amps. @ 30 VAC/VDC MS-7SP Double Action Station (resistive) The MS-7SP is a double action station similar to the MS-7 Dimensions: 5 5/8" H x 4 1/4"W x 1 1/4"D station, with the additional feature of both English and (14 x 10.1 x 3.2 cm) Spanish instructions molded into the unit. Operating Temperature MS-7LR Dual-action Agent Release Station (MS-7AF, MS-7ASF): 32°to 120° F (0°to 49° C) The MS-7LR is designed for use with the Gamewell-FCI (MS-7LOB): -30°to 150° F(-35°to 66° C) fire alarm control panels with releasing capabilities and Relative Humidity Flex Series releasing systems. It features a set of single (MS-7AF, MS-7ASF): 10 to 93% (non-condensing) pole contacts and screw terminals for connection to an ini- (MS-7LOB): 85%±5%@ 86°±3.6° tiating circuit. (30°±2° C) Alarm Current: .0030 amp. 0.007 for LED MS-7LRA Agent Release Station with Abort Supervisory Current The MS-7LRA is designed for use with the Gamewell-FCI (MS-7AF, MS-7ASF): .00030 amps. fire alarm control panels with releasing capabilities and Flex Series releasing systems where system abort capabil- ities are required. It consists of an MS-7LR mounted on a Ordering Information plate with an abort switch and LED indicators for system normal, and system activated status. Part Number Description MS-7LOB Double Action Station MS-7 Double action station (Listed for Outdoor Applications) MS-7AF** Velociti addressable double action The MS-7LOB station must be mounted on a Model SB-I/O station backbox. In retrofit applications,the station is UL Listed for MS-7ASF** Velociti addressable single action station use with the WP-10 backbox. It is intended for use with MS-7S Single action station,wire leads conventional control panels and has a set of single pole MS-7SP Double action station, English and contacts and screw terminals. Spanish instructions Mounting MS-7LR Agent release station, dual-action MS-7LRA Agent release station with abort switch, The MS-7 interior stations may be surface mounted or LED indicators, dual-action semi-flush mounted on a standard double-gang, or 4-inch MS-7LOB Double action station, outdoor use (10.2 cm)square electrical box.An optional trim ring (Includes SB-I/O- Indoor/outdoor use (BG12TR)may also be used for semi-flush mounting. backbox) NYC-Plate SB-I/O Indoor/outdoor use backbackbox The NYC-Plate provides the backplate for the manual pull SB-10 Surface backbox station. (See Figure 1). BG12TR Trim ring for semi-flush mount, plastic NY-PLATE NYC backplate for manual pull station **For use with the Gamewell-FCI analog addressable control panels only. FIRE [4.r.trozi t1=1 Figure 1 NYC-Plate GAMEWELL-FCI 12 Clintonville Road, Northford,CT 06472-1610 USA•Tel:(203)484-7161 •Fax:(203)484-7118 9020-0616 Rev.D page 2 of 2 www.gamewell-fci.com