Date: 7-13-16
Inspection Report
Client: Kumar & Associates/HP Geotech (Job #16-7-139)
Project: 84 Beaver Dam Remodel
Address: 84 Beaver Dam Rd Vail, CO
Building Permit No: B 16-0092
Inspection of shop fabrication or field work at job site: Field
Report#l
Page 1of1
Report: Visually inspected field welding at steel beam connection angle clips to
existing beam East end of lower level framing, and high strength A325 bolting at
steel beam connection angle clips lower level framing & main level framing areas.
Also inspected anchor bolting at steel deck support ledger angles/channels to
concrete walls lower & main level framing areas. Note anchor bolt diameter &
spacing was verified, as I was not present during the installation of the anchor
bolts.
The field welding & bolting inspected above appeared to be in general
conformance with the construction documents, and the quality requirements of the
AWS DI.I Structural Welding Code & AISC/RCSC Specification for A325/A490
bolting.
lnspectorfrechnician: Douglas E Young
,