HomeMy WebLinkAboutB16-0092_A10.1_1480456845.pdfTELEPHONE/
DATA
GFI
WP
220
TV
FAN
3
D
DUPLEX OUTLET
SWITCHED OUTLET (ONE SIDE ONLY)
GROUND FAULT INTERRUPT OUTLET
WATER PROOF GFI OUTLET
220 OUTLET
FLOOR MOUNTED DUPLEX
TELEVISION / PROVIDE 2 RG-6 AND 2 CAT-V
2 CAT V TELEPHONE
RECESSED DIRECTIONAL DOWN LIGHT
FLAT OR SLOPED CEILING
RECESSED 4-LIGHT MULTIPLE
DIRECTIONAL DOWN LIGHT
SURFACE MOUNTED FIXTURE @ WALL
WALL MOUNTED UP LIGHT FIXTURE
WALL MOUNTED STEP LIGHT FIXTURE
SURFACE MOUNTED FLORESCENT
SURFACE MOUNTED ON CEILING
LED LIGHTING UNDER CABINET LIGHTING
SURFACE MOUNTED FLORESCENT MOUNTED ABOVE DOOR HEAD
JUNCTION BOX
EXHAUST FAN
SWITCH
3-WAY SWITCH / 4-WAY SWITCH
DIMMER SWITCH (MAY BE SHOWN AS 3-WAY)
MONOPOINT
J-BOX
MOTORIZED SHADE W/ BUILT-IN POCKET
TRU- FIG DUPLEX OUTLET
TF
DUPLEX OUTLET W/ (2) USB PORTS
USB
GENERAL NOTES:
1. LOCATION OF OUTLETS AND OTHER ELECTRICAL DEVICES IS DIAGRAMMATIC -- ACTUAL PLACEMENT
OF ELEMENTS, WORK, MATERIALS AND EQUIPMENT SHALL CONFORM TO THE LATEST EDITIONS OF
LOCAL, STATE OF COLORADO, AND NATIONAL CODES AND ORDINANCES.
2. OUTLETS TO BE LOCATED VERTICTAL AND CENTER @ 16" ABOVE FINISHED FLOOR, AND SWITCHES
42" ABOVE FINISHED FLOOR, UNLESS OTHERWISE SPECIFIED. AT LOCATIONS WHERE THIS IS NOT
POSSIBLE, CONSULT THE ARCHITECT.
3. PROVIDE SMOKE DETECTORS AS REQUIRED. SMOKE DETECTORS WILL BE CONNECTED TO THE
ALARM SYSTEM
4. ALL DIMENSIONS TO CENTER LINE OF FIXTURE. COORDINATE FIXTURE LOCATION WITH STRUCTURE
AND TO ALIGN AND CENTER FIXTURES AS CLOSE AS POSSIBLE. PROVIDE GFI OUTLET @ EVERY
VANITY, EXCEPT FOR POWDER ROOMS.
5. COORDINATE SWITCHED OUTLETS LOCATIONS AT VANITY WALLS AND FLOORS WITH FURNITURE
PLANS AND INTERIOR DOCUMENTS
6. PROVIDE CARBON MONOXIDE DETECTORS THROUGHOUT THE HOUSE PER R315. CARBON MONOXIDE
DETECTORS WILL BE CONNECTED TO THE ALARM SYSTEM.
7. OUTLETS ABOVE VANITIES TO BE VERTICAL WITH CENTERLINE AT 46" AFF EXCEPT AS NOTED.
VERIFY LOCATION & HEIGHT WITH OWNER
8. VERIFY ALL APPLIANCE ELECTRICAL LOADS WITH OWNER SPECS.
9. PROVIDE POWER AS REQUIRED PER MECHANICAL CONTRACTOR AND SPEC.
10. COORDINATE OUTLET W/ FURNITURE PLANS PER INTERIOR DESIGNER
11. PROVIDE J-BOX FOR HEAT TAPE LOW ON WALL @ ALL DOWNSPOUT LOCATIONS.
12. ALL SWITCHES TO BE DIMMERS.
CNTR
OUTLET W/ USB
REMOVE 4 OUTLETS HIGH
UP ON WALLS
OUTLET W/ USB FLUSH
ON COUNTER TOP
TELEPHONE/
DATA
WILL BE A CHANDELIER.
PROVIDE FAN RATED J-BOX.
ACTIVE LEAF ON
EAST SIDE.
1' - 4"
3' - 5 1/2"
8' - 2 1/2"
3' - 7 1/8"
2' - 0"
A
A
A
A
A
J-BOX
2' - 6"
8' - 1 3/8"
2' - 0 5/8"
4' - 3 3/8"
2' - 0 5/8"3' - 0"
3' - 0"
J-BOX
Q
Q
BENCH
REPLACE EXISTING CAN
FAN
EXISTING BATH FAN
A2
A
A
A
A
PROVIDE SOLID JAMB AND
HEADER TO MATCH CURB DETAIL
@ SHOWER.
SHOWER NICHE TO
MATCH EXISTING
TILE CEILING TO MATCH
EXISTING BATH.
3' - 4 5/8"
WP
0' - 10"1' - 6 7/8"
1' - 3 1/2"
2' - 6 1/8"
2' - 6 1/8"
1' - 4 1/2"
BUILT-IN CABINET
BELOW
EXISTING HEADER
A
A
A
A
LUTRON MOTORIZED SHADE PER
AV CONSULTANT
MOUNT LURTON SHADE
SWITCH ON WALL
CENTERED ABOVE LIGHT
SWITCH
EXISTING CLOSET LIGHT CNTR
TV OUTLET FOR FUTURE TV
TV
ACTIVE LEAF ON
EXISTING DOOR
US Mail Only: P. O. Box 2378
Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Scale
Date
Drawn by
Checked by
Issue Date 9/1/2016 4:37:01 PM
As indicated
84 BEAVER DAM REMODEL
VAIL, CO
A10.1
LOWER
LEVEL RCP
9 - 1 - 2016
CWF
HB
9 - 1 - 2016
PROGRESS SET
REVISION SCHEDULE
# DESCRIPTION DATE
2 LIGHTING
PLAN AND
MOTORIZED
SHADE
9-1-16
1/4" = 1'-0"
ELECTRICAL LEGEND
Lighting Fixture Schedule
Type Mark Type Manufacturer Model Type Comments Count
A FLAT CEILING RECESSED CAN NORA LIGHT W/ HALO
TRIM
NLIC-401 - 3004WHH OR
3009WHWB
3004WHH - WHITE W/ HAZE REFLECTOR @ DRYWALL CEILING.
3009WHWB - WHITE W/ WHITE BAFFLE @ DRYWALL CEILING. WALL
WASHER LOCATIONS - 3" LOW VOLTAGE UNIVERSAL IC HOUSING -
PROVIDE SORAA VIVID 2 LED MR16 35 DEGREE FL, 2700K LAMP
13
A2 FLAT CEILING MOISTURE RESISTANT
RECESSED CAN
NORA LIGHT W/ HALO
TRIM
NLIC-401 - 3008FG WHITE TRIM W/ MOISTURE RESISTANT LENSE 1
J-BOX J-BOX CEILING FAN RATED TDB TDB INTERIOR DECORATIVE FIXTURE TO BE SELECTED BY INTERIOR
DESIGN, EXTERIOR DECOARTIVE FIXTURE TO BE REUSED EXISTING
FIXTURE
2
Grand total: 16
1/2" = 1'-0"
1
BUNK ROOM REFLECTED CEILING PLAN
11/29/16