Loading...
HomeMy WebLinkAboutB16-0092_A3.1A_1480456820.pdfFD 1 A5.1 2 A5.1 FD 1 A6.1 2 A6.1 1 A6.2 1 A6.2 LINE OF CONCRETE WALL AT GARAGE BELOW REBUILD EXISTING GROUTED STONE PATIO. EXISTING RAISED SLAB TO REMAIN REBUILD EXISTING SANDSET STONE PATIO OVER NEW SLAB OVER LOWER EXISTING SLAB TO REMAIN EXISTING SANDSET STONE PATIO TO BE REPLACED WITH NEW GROUTED STONE PATIO WITH CENTER DRAINS TO MATCH EXISTING NEW STONE CAP SLOPE TO DRAIN EXISTING BEDROOM EXISTING BEDROOM EXISTING HANDRAIL TO BE REMOVED AND REUSED, TYP. T.O. EXISTING FINISH FLOOR @ 70' - 9" WALLS TO BE REPLACED W/ CMU CONSTRUCTION AND STONE TO MATCH EXISTING EXISTING WALLS, TYP. 1% SLOPE 1% SLOPE 1% SLOPE 1% SLOPE 1% SLOPE 1% SLOPE 1% SLOPE 1 A5.2 EXISTING BEAM BELOW FD FD EXISTING RAISED PATIO TO REMAIN REMOVE EXISTING MUDSET SANDSTONE PATIO TO TIE NEW W.P.M. INTO EXISTING. REBUILD PATIO. APPROX. LINE OF REBUILD; ADJUST AS REQ'D OVER GARAGE BELOW SLAB ON GRADE 4 A6.1 4' - 6 1/4" 11' - 0" 11' - 0" 10' - 8" 6' - 7" 6' - 7" 2' - 3 1/8" 5' - 6" 5' - 6" 5' - 6" 5' - 6" 5' - 4 1/2" FD FD 3/16" / 12" 3/16" / 12" 1/8" / 12" 3/16" / 12" 3/16" / 12" 1/8" / 12" 1/8" / 12" 3/16" / 12" 1/8" / 12" 1/8" / 12" 3/16" / 12" 3/16" / 12" 3/16" / 12" 1/8" / 12" 3/16" / 12" 1/8" / 12" 3/16" / 12" 1/16" / 12" 1/16" / 12" 3/16" / 12" 3/16" / 12" ASSUMPTION OF EXISTING T.O. PATIO @ 70' - 3 3/4" V.I.F. T.O. DRAIN @ 70' - 2 5/8" T.O. DRAIN @ 70' - 3 3/8" T.O. DRAIN @ 70' - 2 5/8" T.O. DRAIN @ 70' - 2 3/4" T.O. DRAIN @ 70' - 3" T.O. DRAIN @ 70' - 2 3/4" T.O. PATIO @ 70' - 3 3/4" T.O. PATIO @ 70' - 3 3/4" T.O. PATIO @ 70' - 3 3/4" T.O. PATIO @ 70' - 3 3/4" T.O. PATIO @ 70' - 3 3/4" T.O. PATIO @ 70' - 3 3/4" 10' - 1 3/8" 5 1/4" T.O. EXISTING FINISH FLOOR @ 70' - 9" FD 5 1/4" V.I.F. EXISTING FLOOR DRAIN V.I.F. EXISTING ELEVATOR 1/8" / 12" 3/16" / 12" 3/16" / 12" 4 A6.2 EXISTING STL. BEAM BELOW V.I.F. 3/16" / 12" T.O. EXISTING PATIO @ 70' - 7 1/8" V.I.F. VERIFY EXISTING SLOPED CONDITIONS & PATIO HEIGHT IN FIELD EXISTING PATIO (TO REMAIN) 4' - 0" +/- 3' - 1 1/2" OVER GARAGE SLAB ON GRADE 4 A6.3 SIM WRAP NEW W.P. MEMBRANE 24" UP FACE OF CMU COLUMN AND WALL 24" ABOVE T.O. SLAB DOWNSPOUT. VERIFY LOCATION IN FIELD. HARD PIPE INTO DECK DRAIN SYSTEM DOWNSPOUT. VERIFY LOCATION IN FIELD. TIE INTO DECK DRAIN SYSTEM ADJUST AS REQUIRED TO TIE IN NEW W.P. MEMBRANE TO EXISTING 1 A6.1 SIM 1/8" / 12" VERIFY HEIGHT IN FIELD V.I.F. 8 5/16" 3' - 6" NEW WOOD/STEEL FRAMED WALLS, FLOORS, ROOFS AND COLUMNS SHOWN GRAY WITH SOLID BLACK LINES NEW STONE VENEER SHOWN WITH DIAGONAL HATCH NEW CMU WALL SHOWN WITH CROSS HATCH EXISTING WALL, FLOORS, ROOFS AND COLUMNS TO BE DEMOLISHED SHOWN WHITE WITH DASHED BLACK LINES EXISTING WALL, FLOORS, ROOFS AND COLUMNS TO REMAIN SHOWN WHITE WITH SOLID BLACK LINES GENERAL NOTES: 1.) SEE SECTIONS FOR TOP OF EXISTING BEAM INFORMATION. 2.) PROPOSED PATIO HEIGHTS ARE SHOWN BASED ON ASSUMPTIONS OF EXISTING CONDITIONS INCLUDING EXISTING BEAM HEIGHTS AND EXISTING ADJACENT PATIO HEIGHTS. V.I.F. ALL EXISTING CONDITIONS. 3.) ALL NOTES APPLY TO NEW CONSTRUCTION EXCEPT WHERE NOTED WITH "EXISTING". US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Scale Date Drawn by Checked by Issue Date 4/6/2016 4:18:34 PM As indicated 84 BEAVER DAM REMODEL VAIL, CO A3.1A ENLARGED LOWER LEVEL 4-05-2016 CWF HB 4-05-2016 PERMIT SET 1/2" = 1'-0" 1 LOWER LEVEL FLOOR PLAN - NORTH/WEST REVISION SCHEDULE # DESCRIPTION DATE 05/12/16