HomeMy WebLinkAboutB16-0092_A3.2A_1480456822.pdf1 A5.1 2 A5.1 3 A5.1 82' - 6" V.I.F. 81' - 0" V.I.F. FD FD 80' - 5" 80' - 4 7/8" EXISTING RAILING TO BE REMOVED AND REUSED NEW STONE CAP SLOPED TO DRAIN WALLS TO BE REPLACED W/ CMU CONSTRUCTION AND STONE TO MATCH EXISTING DECK TO BE REMOVED AND REPLACED W/ 4" STONE PATIO ASSEMBLY OVER NEW CONCRETE SLAB AND STEEL DECKING OVER STEEL FRAMING RE: STRUCT. DINING ROOM LIVING ROOM 6" 1% SLOPE 1% SLOPE 1% SLOPE 1% SLOPE 80' - 6" V.I.F. EXISTING WALL, TYP. LINE OF FOUNDATION WALL BELOW EXISTING SLAB ON GRADE AND PATIO TO BE REMOVED AND REBUILT EXISTING WOOD FRAMING TO BE REMOVED AND REBUILT WITH NEW STEEL FRAMING EXISTING PATIO/STAIRPATH TO REMAINEXISTING SLAB ONGRADE AND PATIO TO BEREMOVED AND REBUILT3 A6.2 2 A6.2 5/16" / 12" 3/16" / 12" 5/16" / 12" 3/16" / 12" NEW WOOD/STEEL FRAMED WALLS, FLOORS, ROOFS AND COLUMNS SHOWN GRAY WITH SOLID BLACK LINES NEW STONE VENEER SHOWN WITH DIAGONAL HATCH NEW CMU WALL SHOWN WITH CROSS HATCH EXISTING WALL, FLOORS, ROOFS AND COLUMNS TO BE DEMOLISHED SHOWN WHITE WITH DASHED BLACK LINES EXISTING WALL, FLOORS, ROOFS AND COLUMNS TO REMAIN SHOWN WHITE WITH SOLID BLACK LINES 1 A5.3 2 A5.3 3 A5.3 82' - 3 1/2" V.I.F. 82' - 3 1/2" V.I.F. FD FD EXISTING GATE TO BE REMOVED AND REUSED EXISTING RAILING TO BE REMOVED AND REUSED NEW STONE CAP SLOPED TO DRAIN TO MATCH EXISTING WALLS TO BE REMOVED AND REPLACED W/ CMU CONSTRUCTION AND STONE TO MATCH EXISTING 1 1/2" EXISTING MASTER BEDROOM EXISTING MASTER BATHROOM 2 A6.2 A4.1 1 1% SLOPE1% SLOPE 1% SLOPE 1% SLOPE 1% SLOPE 82' - 6" V.I.F. EXISTING STRUCTURE TO BE REMOVED AND REBUILT REBUILT DECKEXISTING PATH OVER SLABON GRADE TO REMAIN T.O. EXISTING PATIO @ 82' - 3" V.I.F. 1/8" / 12"1/4" / 12" 1/4" / 12" 82' - 4 1/2" V.I.F. 1" / 12" 4 A6.3 SIM 1/8" / 12" 1/4" / 12" 1/4" / 12" 1/4" / 12" GENERAL NOTES: 1.) SEE SECTIONS FOR TOP OF EXISTING BEAM INFORMATION. 2.) PROPOSED PATIO HEIGHTS ARE SHOWN BASED ON ASSUMPTIONS OF EXISTING CONDITIONS INCLUDING EXISTING BEAM HEIGHTS AND EXISTING ADJACENT PATIO HEIGHTS. V.I.F. ALL EXISTING CONDITIONS. 3.) ALL NOTES APPLY TO NEW CONSTRUCTION EXCEPT WHERE NOTED WITH "EXISTING". US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Scale Date Drawn by Checked by Issue Date 4/6/2016 4:27:40 PM As indicated 84 BEAVER DAM REMODEL VAIL, CO A3.2A ENLARGED MAIN LEVEL 4-05-2016 EW HB 4-05-2016 PERMIT SET 1/2" = 1'-0" 1 MAIN LEVEL FLOOR PLAN - WEST 1/2" = 1'-0" 2 MAIN LEVEL FLOOR PLAN - EAST REVISION SCHEDULE # DESCRIPTION DATE 05/12/16