HomeMy WebLinkAboutB16-0092_A3.2A_1480456822.pdf1
A5.1
2
A5.1
3
A5.1
82' - 6" V.I.F.
81' - 0" V.I.F.
FD
FD
80' - 5"
80' - 4 7/8"
EXISTING RAILING TO BE
REMOVED AND REUSED
NEW STONE CAP SLOPED TO DRAIN
WALLS TO BE REPLACED W/ CMU
CONSTRUCTION AND STONE TO
MATCH EXISTING
DECK TO BE REMOVED AND REPLACED W/
4" STONE PATIO ASSEMBLY OVER NEW
CONCRETE SLAB AND STEEL DECKING
OVER STEEL FRAMING RE: STRUCT.
DINING ROOM
LIVING
ROOM
6"
1% SLOPE
1% SLOPE
1% SLOPE
1% SLOPE
80' - 6" V.I.F.
EXISTING WALL, TYP.
LINE OF FOUNDATION WALL BELOW
EXISTING
SLAB ON
GRADE
AND
PATIO TO BE
REMOVED
AND
REBUILT
EXISTING
WOOD
FRAMING TO BE REMOVED
AND
REBUILT
WITH
NEW
STEEL
FRAMING
EXISTING PATIO/STAIRPATH TO REMAINEXISTING SLAB ONGRADE
AND PATIO TO BEREMOVED AND REBUILT3
A6.2
2
A6.2
5/16" / 12"
3/16" / 12"
5/16" / 12" 3/16" / 12"
NEW WOOD/STEEL FRAMED WALLS, FLOORS, ROOFS
AND COLUMNS SHOWN GRAY WITH SOLID BLACK LINES
NEW STONE VENEER SHOWN WITH DIAGONAL HATCH
NEW CMU WALL SHOWN WITH CROSS HATCH
EXISTING WALL, FLOORS, ROOFS AND COLUMNS TO BE
DEMOLISHED SHOWN WHITE WITH DASHED BLACK LINES
EXISTING WALL, FLOORS, ROOFS AND COLUMNS TO
REMAIN SHOWN WHITE WITH SOLID BLACK LINES
1
A5.3
2
A5.3
3
A5.3
82' - 3 1/2" V.I.F.
82' - 3 1/2" V.I.F.
FD
FD
EXISTING GATE TO BE
REMOVED AND REUSED
EXISTING RAILING TO BE
REMOVED AND REUSED
NEW STONE CAP SLOPED TO
DRAIN TO MATCH EXISTING
WALLS TO BE REMOVED AND
REPLACED W/ CMU CONSTRUCTION
AND STONE TO MATCH EXISTING
1 1/2"
EXISTING
MASTER
BEDROOM
EXISTING
MASTER
BATHROOM
2
A6.2
A4.1
1
1% SLOPE1% SLOPE
1% SLOPE
1% SLOPE
1% SLOPE
82' - 6" V.I.F. EXISTING STRUCTURE TO BE
REMOVED AND REBUILT
REBUILT DECKEXISTING PATH OVER SLABON GRADE TO REMAIN
T.O. EXISTING PATIO @ 82' - 3" V.I.F.
1/8" / 12"1/4" / 12"
1/4" / 12"
82' - 4 1/2" V.I.F.
1" / 12"
4
A6.3
SIM
1/8" / 12"
1/4" / 12"
1/4" / 12"
1/4" / 12"
GENERAL NOTES:
1.) SEE SECTIONS FOR TOP OF EXISTING BEAM
INFORMATION.
2.) PROPOSED PATIO HEIGHTS ARE SHOWN BASED ON
ASSUMPTIONS OF EXISTING CONDITIONS INCLUDING
EXISTING BEAM HEIGHTS AND EXISTING ADJACENT PATIO
HEIGHTS. V.I.F. ALL EXISTING CONDITIONS.
3.) ALL NOTES APPLY TO NEW CONSTRUCTION EXCEPT
WHERE NOTED WITH "EXISTING".
US Mail Only: P. O. Box 2378
Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Scale
Date
Drawn by
Checked by
Issue
Date
4/6/2016
4:27:40 PM
As indicated
84 BEAVER
DAM
REMODEL
VAIL, CO
A3.2A
ENLARGED
MAIN LEVEL
4-05-2016
EW
HB
4-05-2016
PERMIT SET
1/2" = 1'-0"
1
MAIN LEVEL FLOOR PLAN - WEST
1/2" = 1'-0" 2
MAIN LEVEL FLOOR PLAN - EAST
REVISION SCHEDULE
# DESCRIPTION DATE
05/12/16