HomeMy WebLinkAboutB16-0092_A6.3_1478906469.pdfWINDOW RE: WINDOW SCHEDULE
FILL W/ EXPANDING SPRAY
FOAM INSULATION AND SHIM
AS REQ'D
STONE VENEER TO MATCH EXISTING
1/2" PLYWOOD
BUILDING PAPER LAPS
OVER TOP OF FLASHING
1 1/2" MIN
LAP WATERPROOF
MEMBRANE OVER NAILING
FLANGE AND CONTINUE UP
UNDER FLASHING, UNDER
CHANNEL, AND UNDER
BUILDING PAPER
STEEL ANGLES LAG BOLTED INTO
BLOCKING AND WOOD HEADER
ATTACHMENT TO BE DESIGN BUILD
BY STONE MASON RE: STRUCT.
GRID
LINE
METAL FLASHING WITH DRIP
EDGE TO MATCH WINDOW
COLOR
HEADER RE: STRUCT.
STONE HEADER TO MATCH
EXISTING
INTERIOR TRIM TO MATCH
EXISTING
PROVIDE CAULK JOINT BETWEEN
WINDOW FRAME AND R.O. @
INTERIOR TYP.
WINDOW SET IN BED OF
SEALANT OVER W.P.
MEMBRANE
STONE VENEER TO
MATCH EXISTING
1/2" PLYWOOD
30 # BUILDING PAPER RE: SPEC.
LAP WATERPROOF
MEMBRANE OVER BLDG.
PAPER AND UNDER
WINDOW SILL
2" STONE SILL SLOPED TO
DRAIN @ 10% MIN. TO MATCH
EXISTING STONE
INTERIOR EXTERIOR
INTERIOR TRIM TO MATCH
EXISTING
PROVIDE CAULK JOINT BETWEEN
WINDOW FRAME AND R.O. @
INTERIOR TYP.
LAP ICE AND WATER SHIELD OVER FLASHING
EXISTING FOUNDATION WALL TO REMAIN
NEW CMU WALL RE:STRUCT.
SLOPE @ 10% MIN.
NEW CMU WALL RE:STRUCT. 1/2"
1/2" AIR SPACE
SHIM AS REQ'D
SHIM AS REQ'D
1/2"
1/2" AIR SPACE
P.T. PLATE
P.T. PLATE
STEEL ANGLE EXPLANSION BOLTED
TO FOUNDATION WALL RE: STRUCT.
METAL DRIP EDGE FLASHING TO MATCH ROOF
NEW STANDING SEAM METAL ROOF TO MATCH EXISTING
2X6 DOUG-FIR T&G DECKING
ROOFS TO BE PROTECTED WITH SNOW GUARDS
PER MANF. RECOMMENDATIONS PER ROOF
PITCH AND SNOW LOADS RE: SPEC
T.O. BEAM
RE: STRUCT.
CURVED 6 3/4"X9" GLULAM
RE: STRUCTURAL
5/8" PLYWOOD OVER 1X SLEEPERS TO
CREATE WIRE CHASE FOR EXTERIOR
MONOPOINT LIGHT FIXTURES RE: RCP
9"
6X8 TIMBER TO MATCH EXISTING
WOOD BRACE TO MATCH EXISTING
ATTACHED GLULAM TO TIMBER W/
COUNTER-SUNK LAG BOLTS
10 3/4"
METAL FLASHING TO MATCH ROOF
EXTENDS OVER STANDING SEAM
ROOFING 6" MIN. AND OVER 2X
BUILD UP AND UP WALL UNDER
BUILDING 6" MIN.
2X6 T&G ROOF SHEATHING W/ 1/8" X
1/8" REVEAL @ JOINTS RE: STRUCT.
6 3/4" X 9" GLU-LAM RAFTERS RE: STRUCT.
EXISTING WALL
METAL STANDING SEAM TO
MATCH EXISTING RE: SPEC
VYCOR ICE AND WATER SHIELD
- EXTENDS UP WALL 3' MIN.
RE: SPEC
REPLACE STONE VENEER TO MATCH
EXISTING AS REQ'D
DRAINAGE MEDIUM AND AIR
FILTRATION BARRIER LAPS OVER
FLASHING TO ALLOW WALL TO DRAIN
SOLID WOOD BLOCKING RE:
STRUCT.
MIN 6"
MIN 3"
INTERIOR
EXTERIOR
EXISTING DOOR
5/8" PLYWOOD OVER 1X SLEEPERS TO
CREATE WIRE CHASE FOR EXTERIOR
MONOPOINT LIGHT FIXTURES RE: RCP
REPLACE STONE VENEER TO MATCH
EXISTING AS REQ'D
CURVED STEEL ANGLE ATTACHED TO
EXISTING STRUCTURE RE: STRUCT.
1' - 0"
STEEL ANGLE LAG BOLTED INTO
SOLID BLOCKING RE: STRUCT.
DOOR SET IN A BED OF
SEALANT OVER FLASHING
SEALANT JOINT
NEW CONC. SLAB W/ THICKENED SLAB
EDGE & W/ RADIANT IN-FLOOR HEAT
W.P MEMBRANE UNDER SILL CONT. TO
TOE OF STL. ANGLE
4" ASSEMBLY CONSISTS OF 2"+/- FLAGSTONE TO
MATCH EXISTING OVER +/- 1 1/2" GROUT OVER 1/2"
ASSEMBLY OF CONTINUOUS DRAINAGE MEDIUM (RE:
SPEC) AND CONT. W.P. DECK MEMBRANE. PROVIDE
HEAT TUBE ATTACHED TO WELDED WIRE MESH IN 1
1/2" GROUT BED. (RE: SPEC)..
STONE VENEER BEYOND
TRIM @ WINDOW BEYOND
FINISH @ FLOOR RE:SPEC
PFSM FLASHING TO MATCH WINDOW COLOR
SEPARATE DISSIMILAR METALS FROM STEEL
HEADER WITH ICE AND WATER SHIELD AND
SEALANT. TURNS UP 1/2" @ BACKSIDE OF
DOOR SILL
EXTERIOR
INTERIOR
OUT SWING PATIO DOOR TO
MATCH EXISTING RE:
WINDOW SCHEDULE
DRAINAGE MEDIUM OVER RIGID
INSULATION PANEL AND
CONTINUOUS OVER STEEL
ANGLE LEDGER RE: SPEC
STEEL ANGLE LEDGER EXPANSION
BOLTED TO THICKENED CONCRETE
EDGE. COAT W/ DAMP PROOFING
RE:STRUCT.
V.I.F.
6" STEP
LINE OF EXISTING STONE PATIO TO BE REMOVED
PORTION OF EXISTING SLAB TO BE
REMOVED FOR NEW THICKENED SLAB EDGE
EXISTING SLAB TO REMAIN
2" CONT. RIGID FOAM
INSULATION PANEL UNDER SLAB
2" RIGID INSULATION
CONCRETE FOUNDATION WALL
RE: STRUCT.
GRID
LINE
ALUMINUM L 1/2" X 1/2" X 1/8" ACROSS BACK
OF R.O. TO SERVE AS BACKDAM; ANCHOR TO
SLAB
EXTEND W.P. MEMBRANE INTO SILL OF R.O.,
CONTINUOUSLY UP BACKDAM, AND
CONTINUOUSLY ONTO B.O. JAMBS OF R.O.
TO SERVE AS END DAMS
@ SIM CONDITION, STEP IS 1 1/2"
CUT FLAGSTONE
3 1/4" RIGID INSULATION
SLOPE @ 1.5%
EXISTING WALL AND FLOOR ASSEMBLY
REMOVE EXISTING STONE ABOVE DECK TO INSTALL NEW
W.P. MEMBRANE AND DRAINAGE MIN. 24" UP WALL.
CONTINUOUS STEEL
CHANNEL ATTCHED TO
EXISTING FLOOR
STRUCTURE. HANG
BEAMS ON CONTINUOUS
CHANNEL RE: STRUCT.
LAP 2ND LAYER DRAINAGE MEDIUM OVER FLASHING
OVER CONTINUOUS W.P. MEMBRANE
REBUILD EXISTING FLOOR/WALL AND
PROVIDE BLOCKING AS REQ'D TO SUPPORT
NEW DECK CONSTRUCTION.
CONCRETE TURN UP
2# CLOSED CELL SPRAY
FOAM INSULATION AT
UNDERSIDE OF SLAB TO
ACHIEVE R49.
COPPER FLASHING W/ HEMMED EDGE W/
COTTEN WICKS 20" X 16" O.C.
US Mail Only: P. O. Box 2378
Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Scale
Date
Drawn by
Checked by
Issue
Date
4/6/2016
4:18:51 PM
As indicated
84 BEAVER
DAM
REMODEL
VAIL, CO
A6.3
DETAILS
4-05-2016
EW
HB
4-05-2016
PERMIT SET
3" = 1'-0" 3
NEW WINDOW HEAD/SILL DETAIL
1 1/2" = 1'-0" 1
FAMILY ROOM ROOF DETAIL
1 1/2" = 1'-0" 2
FAMILY ROOF DETAIL AT WALL
3" = 1'-0"
4
DOOR SILL DETAIL @ BUNKROOM (EAST)
3" = 1'-0" 5
STEEL C-CHANNEL @ EXISTING FLOOR
REVISION SCHEDULE
# DESCRIPTION DATE
05/12/16