Loading...
HomeMy WebLinkAboutB16-0092_A6.3_1480456828.pdfWINDOW RE: WINDOW SCHEDULE FILL W/ EXPANDING SPRAY FOAM INSULATION AND SHIM AS REQ'D STONE VENEER TO MATCH EXISTING 1/2" PLYWOOD BUILDING PAPER LAPS OVER TOP OF FLASHING 1 1/2" MIN LAP WATERPROOF MEMBRANE OVER NAILING FLANGE AND CONTINUE UP UNDER FLASHING, UNDER CHANNEL, AND UNDER BUILDING PAPER STEEL ANGLES LAG BOLTED INTO BLOCKING AND WOOD HEADER ATTACHMENT TO BE DESIGN BUILD BY STONE MASON RE: STRUCT. GRID LINE METAL FLASHING WITH DRIP EDGE TO MATCH WINDOW COLOR HEADER RE: STRUCT. STONE HEADER TO MATCH EXISTING INTERIOR TRIM TO MATCH EXISTING PROVIDE CAULK JOINT BETWEEN WINDOW FRAME AND R.O. @ INTERIOR TYP. WINDOW SET IN BED OF SEALANT OVER W.P. MEMBRANE STONE VENEER TO MATCH EXISTING 1/2" PLYWOOD 30 # BUILDING PAPER RE: SPEC. LAP WATERPROOF MEMBRANE OVER BLDG. PAPER AND UNDER WINDOW SILL 2" STONE SILL SLOPED TO DRAIN @ 10% MIN. TO MATCH EXISTING STONE INTERIOR EXTERIOR INTERIOR TRIM TO MATCH EXISTING PROVIDE CAULK JOINT BETWEEN WINDOW FRAME AND R.O. @ INTERIOR TYP. LAP ICE AND WATER SHIELD OVER FLASHING EXISTING FOUNDATION WALL TO REMAIN NEW CMU WALL RE:STRUCT. SLOPE @ 10% MIN. NEW CMU WALL RE:STRUCT. 1/2" 1/2" AIR SPACE SHIM AS REQ'D SHIM AS REQ'D 1/2" 1/2" AIR SPACE P.T. PLATE P.T. PLATE STEEL ANGLE EXPLANSION BOLTED TO FOUNDATION WALL RE: STRUCT. METAL DRIP EDGE FLASHING TO MATCH ROOF NEW STANDING SEAM METAL ROOF TO MATCH EXISTING 2X6 DOUG-FIR T&G DECKING ROOFS TO BE PROTECTED WITH SNOW GUARDS PER MANF. RECOMMENDATIONS PER ROOF PITCH AND SNOW LOADS RE: SPEC T.O. BEAM RE: STRUCT. CURVED 6 3/4"X9" GLULAM RE: STRUCTURAL 5/8" PLYWOOD OVER 1X SLEEPERS TO CREATE WIRE CHASE FOR EXTERIOR MONOPOINT LIGHT FIXTURES RE: RCP 9" 6X8 TIMBER TO MATCH EXISTING WOOD BRACE TO MATCH EXISTING ATTACHED GLULAM TO TIMBER W/ COUNTER-SUNK LAG BOLTS 10 3/4" METAL FLASHING TO MATCH ROOF EXTENDS OVER STANDING SEAM ROOFING 6" MIN. AND OVER 2X BUILD UP AND UP WALL UNDER BUILDING 6" MIN. 2X6 T&G ROOF SHEATHING W/ 1/8" X 1/8" REVEAL @ JOINTS RE: STRUCT. 6 3/4" X 9" GLU-LAM RAFTERS RE: STRUCT. EXISTING WALL METAL STANDING SEAM TO MATCH EXISTING RE: SPEC VYCOR ICE AND WATER SHIELD - EXTENDS UP WALL 3' MIN. RE: SPEC REPLACE STONE VENEER TO MATCH EXISTING AS REQ'D DRAINAGE MEDIUM AND AIR FILTRATION BARRIER LAPS OVER FLASHING TO ALLOW WALL TO DRAIN SOLID WOOD BLOCKING RE: STRUCT. MIN 6" MIN 3" INTERIOR EXTERIOR EXISTING DOOR 5/8" PLYWOOD OVER 1X SLEEPERS TO CREATE WIRE CHASE FOR EXTERIOR MONOPOINT LIGHT FIXTURES RE: RCP REPLACE STONE VENEER TO MATCH EXISTING AS REQ'D CURVED STEEL ANGLE ATTACHED TO EXISTING STRUCTURE RE: STRUCT. 1' - 0" STEEL ANGLE LAG BOLTED INTO SOLID BLOCKING RE: STRUCT. DOOR SET IN A BED OF SEALANT OVER FLASHING SEALANT JOINT NEW CONC. SLAB W/ THICKENED SLAB EDGE & W/ RADIANT IN-FLOOR HEAT W.P MEMBRANE UNDER SILL CONT. TO TOE OF STL. ANGLE 4" ASSEMBLY CONSISTS OF 2"+/- FLAGSTONE TO MATCH EXISTING OVER +/- 1 1/2" GROUT OVER 1/2" ASSEMBLY OF CONTINUOUS DRAINAGE MEDIUM (RE: SPEC) AND CONT. W.P. DECK MEMBRANE. PROVIDE HEAT TUBE ATTACHED TO WELDED WIRE MESH IN 1 1/2" GROUT BED. (RE: SPEC).. STONE VENEER BEYOND TRIM @ WINDOW BEYOND FINISH @ FLOOR RE:SPEC PFSM FLASHING TO MATCH WINDOW COLOR SEPARATE DISSIMILAR METALS FROM STEEL HEADER WITH ICE AND WATER SHIELD AND SEALANT. TURNS UP 1/2" @ BACKSIDE OF DOOR SILL EXTERIOR INTERIOR OUT SWING PATIO DOOR TO MATCH EXISTING RE: WINDOW SCHEDULE DRAINAGE MEDIUM OVER RIGID INSULATION PANEL AND CONTINUOUS OVER STEEL ANGLE LEDGER RE: SPEC STEEL ANGLE LEDGER EXPANSION BOLTED TO THICKENED CONCRETE EDGE. COAT W/ DAMP PROOFING RE:STRUCT. V.I.F. 6" STEP LINE OF EXISTING STONE PATIO TO BE REMOVED PORTION OF EXISTING SLAB TO BE REMOVED FOR NEW THICKENED SLAB EDGE EXISTING SLAB TO REMAIN 2" CONT. RIGID FOAM INSULATION PANEL UNDER SLAB 2" RIGID INSULATION CONCRETE FOUNDATION WALL RE: STRUCT. GRID LINE ALUMINUM L 1/2" X 1/2" X 1/8" ACROSS BACK OF R.O. TO SERVE AS BACKDAM; ANCHOR TO SLAB EXTEND W.P. MEMBRANE INTO SILL OF R.O., CONTINUOUSLY UP BACKDAM, AND CONTINUOUSLY ONTO B.O. JAMBS OF R.O. TO SERVE AS END DAMS @ SIM CONDITION, STEP IS 1 1/2" CUT FLAGSTONE 3 1/4" RIGID INSULATION SLOPE @ 1.5% EXISTING WALL AND FLOOR ASSEMBLY REMOVE EXISTING STONE ABOVE DECK TO INSTALL NEW W.P. MEMBRANE AND DRAINAGE MIN. 24" UP WALL. CONTINUOUS STEEL CHANNEL ATTCHED TO EXISTING FLOOR STRUCTURE. HANG BEAMS ON CONTINUOUS CHANNEL RE: STRUCT. LAP 2ND LAYER DRAINAGE MEDIUM OVER FLASHING OVER CONTINUOUS W.P. MEMBRANE REBUILD EXISTING FLOOR/WALL AND PROVIDE BLOCKING AS REQ'D TO SUPPORT NEW DECK CONSTRUCTION. CONCRETE TURN UP 2# CLOSED CELL SPRAY FOAM INSULATION AT UNDERSIDE OF SLAB TO ACHIEVE R49. COPPER FLASHING W/ HEMMED EDGE W/ COTTEN WICKS 20" X 16" O.C. US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Scale Date Drawn by Checked by Issue Date 4/6/2016 4:18:51 PM As indicated 84 BEAVER DAM REMODEL VAIL, CO A6.3 DETAILS 4-05-2016 EW HB 4-05-2016 PERMIT SET 3" = 1'-0" 3 NEW WINDOW HEAD/SILL DETAIL 1 1/2" = 1'-0" 1 FAMILY ROOM ROOF DETAIL 1 1/2" = 1'-0" 2 FAMILY ROOF DETAIL AT WALL 3" = 1'-0" 4 DOOR SILL DETAIL @ BUNKROOM (EAST) 3" = 1'-0" 5 STEEL C-CHANNEL @ EXISTING FLOOR REVISION SCHEDULE # DESCRIPTION DATE 05/12/16