HomeMy WebLinkAboutB16-0092_A6.4_1480456830.pdfDOOR SET IN A BED OF
SEALANT OVER FLASHING
SEALANT JOINT
NEW CONC. SLAB W/ THICKENED SLAB
EDGE & W/ RADIANT IN-FLOOR HEAT
W.P MEMBRANE UNDER SILL CONT. TO
TOE OF STL. ANGLE
NEW 3" STONE FLOORING ASSEMBLY - APPROX.
1 1/2" TO 2" OF STONE OVER 1" TO 1 1/2" GROUT
OVER CONC. SLAB W/ HEAT TUBE SLOPED @ MIN.
1/4:12 W/ THICKENED EDGE RE: STRUCT.
STONE VENEER BEYOND
TRIM @ WINDOW BEYOND
FINISH @ FLOOR RE:SPEC
PFSM FLASHING TO MATCH WINDOW COLOR
SEPARATE DISSIMILAR METALS FROM STEEL
HEADER WITH ICE AND WATER SHIELD AND
SEALANT. TURNS UP 1/2" @ BACKSIDE OF
DOOR SILL
EXTERIOR
INTERIOR
OUT SWING PATIO DOOR TO
MATCH EXISTING RE:
WINDOW SCHEDULE
DRAINAGE MEDIUM OVER RIGID
INSULATION PANEL AND
CONTINUOUS OVER STEEL
ANGLE LEDGER RE: SPEC
STEEL ANGLE LEDGER EXPANSION
BOLTED TO THICKENED CONCRETE
EDGE. COAT W/ DAMP PROOFING
RE:STRUCT.
V.I.F.
6" STEP
LINE OF EXISTING STONE PATIO TO BE REMOVED
PORTION OF EXISTING SLAB TO BE
REMOVED FOR NEW THICKENED SLAB EDGE
EXISTING SLAB TO REMAIN
2" CONT. RIGID FOAM
INSULATION PANEL UNDER SLAB
2" RIGID INSULATION
CONCRETE FOUNDATION WALL
RE: STRUCT.
GRID
LINE
ALUMINUM L 1/2" X 1/2" X 1/8" ACROSS BACK
OF R.O. TO SERVE AS BACKDAM; ANCHOR TO
SLAB
WRAP W.P. MEMBRANE UP WALL AND SEAL
TO B.O. DOOR SILL EXTERIOR
@ SIM CONDITION, STEP IS 1 1/2"
CUT FLAGSTONE
3 1/4" RIGID INSULATION
US Mail Only: P. O. Box 2378
Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Scale
Date
Drawn by
Checked by
Issue
Date
4/6/2016
4:18:52 PM
3" = 1'-0"
84 BEAVER
DAM
REMODEL
VAIL, CO
A6.4
ROOF
DETAILS
4-05-2016
CWF
HB
4-05-2016
PERMIT SET
3" = 1'-0" 1
EXISTING DOOR DETAIL @ SILL
REVISION SCHEDULE
# DESCRIPTION DATE
05/12/16