HomeMy WebLinkAboutB16-0402_A1.0_1490108418.pdfOutside changes include rebuilding north, west, and south decking and adjusted grading to allow for lower window sills to meet egress code at the lower
level. The existing windows, roofing, deck surfaces, deck membranes and exterior finishes of the home are proposed to be replaced as part of the
remodel. Proposed new insulation panels will wrap all exterior walls and new siding applied. A new steel railing is proposed at the new deck to meet code.
Some windows have increased head heights and lowered sill heights, see drawings and window schedule for locations and sizes. The east deck and
railing are to remain as-is.
It is proposed that the lower level bedrooms will be reconfigured to maximize space via relocation of existing walls and doors. Lower level bathrooms will
have added walls to support pocket doors. All vanities in the house will be replaced and/or relocated. Downstairs bedroom #4 will receive new sliding
doors in the closet, and a sliding barn door to the guest suite from the foyer is proposed. Guest suite living will receive a new window to match the other
windows. The wet bar will receive an under counter washer/dryer combo unit. The existing washer/dryer location in the utility room will be relocated within
the same space, and the existing walls will be demolished. A proposed mechanical room will take their place. Existing lockers are to be demolished and
rebuilt in the downstairs hall. Lower level bathrooms are to be reconfigured with new walls as shown, and new vanities/fixtures throughout. Separate
lockable closets are to be provided in all bedrooms except #2 and #4. On the main floor, the master bathroom's dividing walls will be demolished and
rebuilt according to plan. A single vanity is to be relocated. A separate shower and tub are to be built. The door locations to this bathroom and the
master bedroom will be moved outward to allow for furniture on the master bedroom wall. The main living area will receive new clerestory windows and a
new window configuration of the existing windows. The dining area and kitchen will be one single space as the walls separating them will be demolished.
New and larger windows will replace the existing, and a new door added in the dining room. The stairwell on the main level will be enclosed with drywall.
The upper level will receive minor changes including separate lockable closets, new swing doors, and new vanities. The interior railings and stairs are to
remain as-is.
PROPOSED SQUARE FOOTAGE ANALYSIS:
1250 PTARMIGAN ROAD, VAIL, CO, 81657
Zone District: Two-family Primary/Secondary Residential (PS)
Lot is .437 acres, equal to 19,036 SF
Allowable GRFA
.46 SF/1 SF of site area < 10,000 SF of site area 10,000 x 0.46 equals 4,600 SF
.38 SF per 1 SF of site area > 10,000 SF of site area 5,000 x 0.38 equals 1,900 SF
.13 SF per 1 SF of site area > 15,000 SF of site area 4,036 x 0.13 equals 525 SF
_______________________________________________________________________________
Total Allowed Gross Residential Floor Area (GRFA) for entire lot 7,025 SF
Proposed Square Footage Summary
Habitable SF GRFA
Lower Level 2,068 SF 1,386* SF
Main Level 2,184 SF 2,184 SF
Upper Level 1,111 SF 1,804 SF
Garage area over 600 SF 0 SF 0 SF
______________________________________
Total 5,363 SF 5,374 SF
Total Allowable GRFA 7,025 SF
Total Remaining GRFA 1,651 SF
*(See sheet A2.1 for Lower Level GRFA calculations)
Site Coverage
Allowable Site Coverage is 20% of the lot 3,807 SF
Proposed Site Coverage 2,645 SF
Proposed Site Coverage for Roofs beyod 4' 111 SF
Total Proposed Site Coverage SF
Total Remaining Site Coverage 1,051 SF
Landscape Area
Lot Size 19,036 SF
60% Landscape Area Requirement 11,421 SF
Lot Size 19,036 SF
LESS
Building Footprint / Driveway 3,840 SF
Total Landscape Area 15,196 SF
Total Hardscape Area Provided (1.2%) 177 SF
Total Softscape Area Provided 15,019 SF
Setbacks
20' from front
15' from sides
15' from rear
Patio can extend to 1/2 the distance of the setback
Decks can encroach set back 5'
Roof or architectural projections can encroach 4'
Height
Flat or mansard roofs not to exceed 30'
Sloping roof not to exceed 33'
Garage
Allow 600 sq. ft. per unit. before area counts towards GRFA
Parking Required per Chapter 10
If a dwelling unit's gross residential floor area is 5,500 square feet or more: 5 spaces
Scale
Date
Drawn by
Checked by
US Mail Only: P. O. Box 2378
Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
4
1
A5.1
A
3.2
PROJECT DIRECTORY
1
2
3
4
A9.1
A6.1
1
A6.1
1
100
LIVING
1
A4.1
SIM.
SYMBOL LEGEND
ABBREVIATIONS
MATERIAL LEGEND
DRAWING LIST:
VICINITY MAP
100
A
BUILDING
SECTION NO.
SECTION CUT
SHEET NO.
DETAIL NO.
DETAIL CUT
SHEET NO.
ROOM NUMBER
EXTERIOR ELEVATION
DOOR MARK
DETAIL CUT
REFERENCE GRID LINE
SPOT ELEVATION
DRAWING REVISION
INTERIOR ELEVATION
WINDOW MARK
Galvanized
Laminated Wood Beam
General Contractor
Hardware
Gypsum Wallboard
Grade
Gypsum
RW
RO
SEW
SECT
SAN
SHLV
Cpt Carpet
Ceramic
CER
SIM
SHT
W/
Reinforce (d)
REINF
FD Floor Drain
With (comb. form)
Required
Round Head Sheet Metal Screw
GA
FDN
FTG
Room
RM
RHSM
REQD
Gauge
Foundation
Footing
WD
W/O
Wood
Without
and Air Conditioning
Heating, Ventilating,
Lavatory
Manufacturer
Laminate
Inside Diameter
Miscellaneous
Mechanical
Not In Contract
Medicine Cabinet
Masonry Opening
Horizontal
On Center
Not to Scale
Oriented Strand Board
Opposite
Outside Diameter
Property
Plywood
Perforated (d)
Prefinished Sheet Metal
Penny (nails, etc.)
Refrigerator
Radius or Riser
Not Applicable
AAD
ADD
AGG
ADJ
AOR
BM
ARCH
ALT
BD
BS
BET
BRG
AFF
CL
BLDG
CAB
CLOS
CMU
CJ
CONC
COL
DP
DIA
DET
CONT
BO
DR
DN
DW
EL
EA
DRWG
DS
EQ
EJ
EXIST
EXT
FE CABT
FOC
FOS
FP
FL
FIN
DIM
GC
GALV
Glass
GLB
GR
GL
Head
HD
HDW
GWB
Highway
Height
HWY
HT
HVAC
GYP
Addendum
Attic Access Door
Aggregate
Adjacent
Area of Refuge
Alternate
Beam
Architectural
Board
Between
Both Sides
Bearing
Above Finished Floor
Interior
Joint
JT
INT
ID
MO
MFG
LAV
LAM
Maximum
Material
MAX
MC
MTL
Minimum
NIC
MISC
MIN
MECH
Cabinet
Building
Centerline
Closet
Concrete
Column
Construction Joint
Detail
Diameter
Damproofing
Continuous
Concrete Masonry Unit
HOR
Bottom Of
Opening
OPG
OC
NTS
d
OD
OSB
OPP
Plate
PL
PFSM
PLWD
PERF
Project
Product
PROD
PROP
PROJ
Drain
Dishwasher
Down
Elevation
Each
Drawing
Downspout
Equal
Existing
Exterior
Expansion Joint
Face Of Concrete
Face Of Stud
Fire Extinguisher Cabinet
Refer
REF
REFR
Floor
Fireproof R
Finish
NA
Dimension
Tounge and Groove
Toilet Paper Holder
Sound- Transmission Class
Vinyl Asbestos Tile
United States Gage
Unless Noted Otherwise
Uniform Building Code
SL
SQ
SPEC
STC
SM
SUB
STRUCT
STL
TV
TEL
SUSP
SUPPL
IE
THK
TEMP
TO
T&B
T&G
TPH
STD
Roof Window
Sewer
Sanitary
Section
Rough Opening
Sliding
Shelves
Similar
Square
Specification
Sheet Metal
Sheet
Steel
Substitute
Structure (al)
Television
Telephone
Suspend (ed)
Supplement (al)
That Is
Thick
Tempered
Top Of
Top and Bottom
Standard
UG
TYP
TS
USG
UBC
UNFIN
U.N.O.
VENT
VIF
VERT
VAR
VAT
WC
V
WT
WIN
WP
Typical
Underground
Tube Steel
Unfinished
Variable
Vertical
Ventilate
Verify In Field
Voltage
Water Closet
Weight
Window
Waterproof
T Tread
FINISHED WOOD
ROUGH FRAMING OR
ROUGH SAWN TRIM
WOOD BLOCKING
CONCRETE
STONE
TILE
GLAZING
FRAME WALL
CONCRETE MASONRY
PARTICLE BD. OR
GLU-LAM WOOD
WOOD FIBER BD.
RIGID INSULATION
CARPET
ACOUSTICAL CEILING
STEEL
PLYWOOD
SHEET METAL
BATT INSULATION
GYP. WALL BOARD/
STUCCO/ PLASTER
ALUMINUM OR
SECTION PLAN
SECTION PLAN
ROCK/
SOIL/ COMPACTED FILL
SAND
NON-COMPACTED FILL
Issue Date:
ELEV. 100'-0"
T.O. PWD.
SITE ELEV. = 116'-0"
Power Actuated Fastened
PAF
Issue Date
CODE: 2015 TOWN OF VAIL, OCCUPANCY TYPE: SINGLE FAMILY HOME
ENERGY CONSERVATION: THE BUILDING COMPLIES WITH THE ENERGY CONSERVATION REQUIREMENT FROM CHAPTER 4 OF THE 2015
INTERNATIONAL ENERGY CODE PER ZONE 6B ADOPTED BY THE TOWN OF VAIL, AND AS DEMONSTRATED BY PRESCRIPTIVE BUILDING
THERMAL ENVELOPE, AS FOLLOWS:
Maximum Glazing U-Factor of .30 for new single family dwelling units per Town of Vail amendments, this can be a weighted average.
The Jeld-Wen windows and doors with dual glazed Low E glazing (Low E on two surfaces) exceeds this requirement - Average U-Value = .28. See 8.5 x 11
window proposal from manufacture for summary of U-values.
Occupancy Type: Single Family
Building complies with the Energy Conservation requirement in Chapter 4 of the 2015 IECC per Zone 6B as adopted by Town of Vail as follows:
The following is a summary for the climate zone 6B of Table 402.1.1 requirements of the IECC, as adopted by Town of Vail, and an outline of the provided R
values of the assemblies of the building which are defined in the Construction Document Drawings and Specifications:
Ceilings & Roofs Insulation - Requirement of R-49 which is reduced to R-38 per 402.2.1 since the construction techniques provide a full R-38 insulation value
over the wall top plate.
@ Typical Roof Condition - Provide approximate insulation value of R-39.6 2# closed cell spray foam insulation in existing 6" cold rack cavity and 1/2" sheathing
(for 6 1/2" total depth), over existing roof sheathing.
@ Master Bedroom Roof Condition - Provides approximate insulation value of R-38 over the wall top plate per the sum of the existing cavity insulation and the
new R-16.5 2 1/2" polyiso foam insulation panels and 1/2" sheathing (for 3" total depth), over existing roof sheathing.
Exterior Walls Insulation - Requires R-20: Providing approximate R-20 per the sum of the existing cavity insulation and the new 3" nail base insulation panel (1/2"
exterior sheathing, R-9 2 1/2" rigid fiberglass insulation panels) with exterior wall finish (stucco, wood siding, or stone veneer), over existing wall sheathing.
CODE INFORMATION
PROJECT INFORMATION
ARCHITECT
BERGLUND ARCHITECTS, LLC
P.O. Box 2378
210 Edwards Village Blvd
Suite A103
Edwards, CO 81632
Phone: (970) 926-4301
Fax: (970) 926-4364
hans@berglundarchitects.com
STRUCTURAL
ENGINEER
LANDSCAPE
ARCHITECT
CLIENTS
CONTRACTOR SURVEYOR
Eagle Valley Surveying
Contact: Mike Post
41199 hwy 6 & 24, Eagle Vail
Avon, CO 81632
Phone: (970) 949-1406
Fax: (970) 479-0055
mikepost@evsurvey.com
MECHANICAL
ENGINEER
SOILS ENGINEER
HP Geotech
Contact: Steve Pawlak
5020 County Road 154
Glenwood Springs, CO
81601
Phone: (970) 945-7988
Fax: (970) 945-8454
KRM Consultants Inc.
Contact: Tim Hennum
P.O. Box 4572
Vail, CO 81658
Office: (970) 949-9391
Fax: (970 949-0839
krm@krmconsultants.com
Kissane Construction
Contact: Jeff Kissane
Phone: (970) 376-6184
jeff@kissaneconstruction.com
Trammell Crow
Contact: Tommy Bishop
3819 Maple Avenue
Dallas, TX 75219
Phone: (214) 455-0191
tommybishopasid@gmail.com
DESIGN BUILD
DESIGN BUILD
PROJECT DESCRIPTION
1/4" = 1'-0"
8/26/2016 3:28:27 PM
1250 PTARMIGAN ROAD
VAIL VILLAGE SUB, LOT 3 & 4, PT OF
BLOCK 8, VAIL, CO
A1.0
COVER
SHEET
August 26th, 2016
CROW RESIDENCE
August 26th, 2016
BUILDING PERMIT SET
August 26th, 2016
BUILDING PERMIT SET
CROW RESIDENCE
A1.0 COVER SHEET
SURVEY
ARCHITECTURAL DRAWINGS
A2.0 SITE PLAN
A2.1 AREA CALCS
A3.1 LOWER LEVEL FLOOR PLAN
A3.2 MAIN LEVEL FLOOR PLAN
A3.3 UPPER LEVEL FLOOR PLANN
A3.4 ROOF PLAN
A4.1 ELEVATIONS
A4.2 ELEVATIONS
A4.3 ELEVATIONS
A4.4 ELEVATIONS
A4.8 3D VIEWS
A5.1 BUILDING SECTIONS
A5.2 BUILDING SECTIONS
A5.3 BUILDING SECTIONS
A5.4 BUILDING SECTIONS
A5.5 BUILDING SECTIONS
A5.6 BUILDING SECTIONS
A5.7 BUILDING SECTIONS
A6.1 WALL DETAILS
A6.2 ROOF DETAILS
A6.2A ROOF DETAILS
A6.2B ROOF DETAILS
A6.3 DECK DETAILS
A6.4 DECK DETAILS
A6.5 DECK DETAILS
A6.6 DECK DETAILS
A6.7 DECK DETAILS
A6.8 STAIR DETAILS
A6.9 STAIR DETAILS
A8.0 WINDOW AND DOOR SCHEDULE
A8.1 WINDOW AND DOOR DETAILS
A10.1 LOWER LEVEL RCP
A10.2 MAIN LEVEL RCP
A10.3 UPPER LEVEL RCP
EXISTING DRAWINGS INCLUDED FOR REFERENCE
E2.0 EXISTING SITE PLAN
E3.1 EXISTING LOWER LEVEL FLOOR PLAN
E3.2 EXISTING MAIN LEVEL FLOOR PLAN
E3.3 EXISTING UPPER LEVEL FLOOR PLAN
E3.4 EXISTING ROOF PLAN
E4.1 EXISTING ELEVATIONS
E4.2 EXISTING ELEVATIONS
E4.3 EXISTING ELEVATIONS
E4.4 EXISTING ELEVATIONS
E5 FLOOR PLANS
E6 FLOOR PLANS
E7 ELEVATIONS
E8 WINDOW AND DOOR SCHEDULE
E9 ELECTRICAL
E10 ELECTRICAL
STRUCTURAL DRAWINGS
S1
S2
S3
GENERAL NOTES
A. THE CONTRACT DOCUMENTS CONSIST OF ARCHITECTURAL AND STRUCTURAL
DRAWINGS, THE AGREEMENT, THE GENERAL NOTES AND THE SPECIFICATIONS. ANY
WORK SHOWN IN ONE OF THE DOCUMENTS SHALL BE SUPPLIED AS THOUGH FULLY
COVERED IN ALL. ANY DISCREPANCY BETWEEN THE DIFFERENT PARTS SHOULD BE
REPORTED TO THE ARCHITECT IMMEDIATELY.
B. CONTRACTOR WILL ASSUME RESPONSIBILITY OF ITEMS REQUIRING COORDINATION
AND RESOLUTION DURING THE CONSTRUCTION PROCESS.
C. ALL WORK SHALL COMPLY WITH ALL STATE AND LOCAL CODES AND ORDINANCES,
AND SHALL BE PREFORMED TO THE HIGHEST STANDARDS OF CRAFTSMANSHIP BY
JOURNEYMAN OF THE APPROPRIATE TRADES.
D. THESE DOCUMENTS ARE INTENDED TO INCLUDE ALL LABOR, MATERIALS, EQUIPMENT
AND SERVICES REQUIRED TO COMPLETE ALL WORK DESCRIBED HEREIN. IT IS THE
RESPONSIBILITY OF THE CONTRACTOR TO BRING TO THE ATTENTION OF THE
ARCHITECT ANY CONDITIONS WHICH WILL NOT PERMIT CONSTRUCTION ACCORDING
TO THE INTENTIONS OF THESE DOCUMENTS. IT IS THE RESPONSIBILITY OF THE
ARCHITECT TO PROVIDE DETAILS AND/OR DIRECTIONS REGARDING DESIGN INTENT
WHERE IT IS ALTERED BY EXISTING CONDITIONS OR WHERE NEGLECTED IN THE
DOCUMENTS.
E. ANY MATERIALS PROPOSED FOR SUBSTITUTION OF THOSE SPECIFIED OR CALLED
OUT BY TRADE NAME IN THESE DOCUMENTS SHALL BE PRESENTED TO THE
ARCHITECT FOR REVIEW. THE CONTRACTOR SHALL SUBMIT SAMPLES WHEN
REQUIRED BY THE ARCHITECT. AND ALL SUCH SAMPLES SHALL BE REVIEWED BY THE
ARCHITECT BEFORE THE WORK IS PERFORMED. WORK MUST CONFORM TO THE
REVIEWED SAMPLES. ANY WORK WHICH DOES NOT CONFORM SHALL BE REMOVED
AND REPLACED WITH WORK WHICH CONFORMS AT THE CONTRACTOR'S EXPENSE.
SUBCONTRACTORS SHALL SUBMIT REQUESTS AND SAMPLES FOR REVIEW THROUGH
THE GENERAL CONTRACTOR WHEN WORK IS LET THROUGH HIM OR HER. REQUIRED
VERIFICATIONS AND SUBMITTALS TO BE MADE IN ADEQUATE TIME AS TO NOT DELAY
PROGRESS.
F. SHOP DRAWINGS SHALL BE SUBMITTED TO THE ARCHITECT FOR HIS OR HER REVIEW
WHERE CALLED FOR ANYWHERE IN THESE DOCUMENTS. REVIEW SHALL BE MADE BY
THE ARCHITECT BEFORE WORK IS BEGUN, AND WORK SHALL CONFORM TO THE
REVIEWED SHOP DRAWINGS, SUBJECT TO REPLACEMENT AS REQUIRED IN
PARAGRAPH E ABOVE.
G. THE BUILDING INSPECTOR SHALL BE NOTIFIED BY THE CONTRACTOR WHEN THERE IS
NEED OF INSPECTION AS REQUIRED BY THE 2015 INTERNATIONAL RESIDENTIAL
CODE OR ANY LOCAL CODE OR ORDINANCE.
H. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY AND CARE OF
ADJACENT PROPERTIES DURING CONSTRUCTION, FOR COMPLIANCE WITH FEDERAL
AND STATE O.S.H.A. REGULATIONS, AND FOR THE PROTECTION OF ALL WORK UNTIL
IT IS DELIVERED COMPLETED TO THE OWNER.
I. ALL DIMENSIONS NOTED TAKE PRECEDENCE OVER SCALED DIMENSIONS.
DIMENSIONS NOTED WITH "N.T.S." DENOTES NOT TO SCALE.
J. CONTRACTOR SHALL VERIFY AND COORDINATE ALL OPENINGS THROUGH FLOORS,
CEILINGS, AND WALLS WITH ALL ARCHITECTURAL, STRUCTURAL, MECHANICAL,
PLUMBING, AND ELECTRICAL DRAWINGS.
K. CONTRACTOR TO COORDINATE NEW CONSTRUCTION W/ EXISTING CONDITIONS AND
NOTIFY ARCHITECT AND STRUCTURAL ENGINEER ABOUT DISCREPANCIES OF
DRAWINGS OF EXISTING HOUSE AND ASSUMPTIONS.
REVISION SCHEDULE
# DESCRIPTION DATE
03/21/17