Loading...
HomeMy WebLinkAboutB16-0402_A10.2_1478904055.pdfA4.4 A4.2 1 1 A4.3 A4.1 1 1 1 2 4 5 A B C D E F G 3' - 6 7/8" 22' - 0" 23' - 10 7/8" 2' - 5 1/2" 7' - 0 3/4" 6' - 9 5/8" 3' - 8 3/8" MASTER BEDROOM 200 BATHROOM 203 STUDY 201 LIVING 206 DINING 205 B.O. GWB @ 8' - 0" B.O. GWB @ 8' - 0" B.O. GWB @ 8' - 0" B.O. GWB @ 8' - 0" B.O. GWB @ 8' - 0" MASTER BATHROOM 202 KITCHEN 204 B B B B LINE OF DECK 3" / 12" PROPOSED BUILT-IN PROPOSED BUILT-IN 1 A5.1 1 A5.2 1 A5.3 1 A5.4 1 A5.5 1 A5.7 1 A5.6 3 15' - 10 5/8" 15' - 10 1/2" 18' - 7 3/4" PROPOSED 2X4 WALL TO ENCLOSE STAIRS 1 A5.8 WOOD FRAMED WALLS, FLOORS, AND, ROOFS AND COLUMNS SHOWN WHITE WITH SOLID BLACK LINES NEW REBUILT STRUCT. @ W.P. DECK ABOVE SHOWN WITH DIAGONAL HATCH CONCRETE WALL SHOWN WITH HATCH EXISTING WALL NEW WALL MODIFIED EXISTING WALL TO ADD INSULATION, VAPOR BARRIER, DRYWALL + ELEC. ETC. DEMOLISHED GENERAL NOTES: 1. LOCATION OF OUTLETS AND OTHER ELECTRICAL DEVICES IS DIAGRAMMATIC--ACTUAL PLACEMENT OF ELEMENTS, WORK, MATERIALS, AND EQUIPMENT SHALL CONFORM TO THE LATEST EDITIONS OF LOCAL , STATE OF COLORADO, AND NATIONAL CODES AND ORDINANCES. 2. OUTLETS TO BE 16" TO CENTER LINE AND SWITCHES TO BE 42" TO CENTER LINE ABOVE FINISHED FLOOR UNLESS OTHERWISE SPECIFIED. AT LOCATIONS WHERE THIS IS NOT POSSIBLE CONSULT THE ARCHITECT. 3. PROVIDE SMOKE DETECTORS AS REQUIRED. 4. ALL DIMENSIONS TO CENTER LINE OF FIXTURE. COORDINATE FIXTURE LOCATION WITH STRUCTURE AND TO ALIGN AND CENTER FIXTURES AS CLOSE AS POSSIBLE. 5. OUTLETS ABOVE VANITIES TO BE VERTICAL WITH CENTER LINE AT 46" AFF EXCEPT AS NOTED. 6. COORDINATE LOCATIONS OF J BOXES FOR TRACK LIGHTING SYSTEM WITH ACTUAL TRACK LIGHT SELECTED BY OWNER. 7. COORDINATE ACTUAL LOCATION OF ALL SWITCHES, OUTLETS, AND LIGHTS WITH OWNER. 8. PROVIDE CARBON MONOXIDE DETECTORS THROUGHOUT EXISTING HOUSE PER R315 ADJUST PLUMBING & ELECTRICAL AS REQ'D & PER CODE PER REVISED LAYOUT SEE INTERIOR DESIGNER DRAWINGS 7' - 5 1/4" EQ EQ US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Scale Date Drawn by Checked by Issue Date 8/26/2016 3:42:34 PM 1250 PTARMIGAN ROAD VAIL VILLAGE SUB, LOT 3 & 4, PT OF BLOCK 8, VAIL, CO 1/4" = 1'-0" CROW RESIDENCE A10.2 MAIN LEVEL RCP August 26th, 2016 AH AG August 26th, 2016 BUILDING PERMIT SET 1/4" = 1'-0" 1 MAIN LEVEL REFLECTED CEILING PLAN 0' 2' 4' 8' 16' NORTH REVISION SCHEDULE # DESCRIPTION DATE 10/14/16