HomeMy WebLinkAboutB16-0402_A6.2_1478904090.pdfGRID
LINE
1"
TYP. EXT. VERTICAL WOOD SIDING
MATCH EXISTING OVERHANG TYPICAL
EXISTING 5 1/2" X 14 1/2" GLULAM
SEE 1/A6.2 FOR TYPICAL ROOF
DETAIL NOTES
SLOPE TO MATCH EXISTING
SLOPE TO MATCH EXISTING
EXISTING RIDGE BEAM RE: STRUCT
ASPHALT SHINGLE ROOF
RE:SPEC
1/2" PLYWOOD SHEATHING OVER
SPRAY FOAM INSULATION
HIGH TEMP ICE AND WATER
SHIELD - CONTINUOUS @ ROOF
AND OVER RIDGE RE: SPEC
RIDGE CAP RE: SPEC.
EXISTING WALL @ LIVING ROOM
SEE 1/A6.2 FOR TYPICAL NOTES
GRID
LINE
EXISTING 2X RAFTER @ 16" O.C.
EXISTING BLOCKING
EXISTING 2X4 RAFTERS STACKED
EXISTING PLYWOOD SHEATHING RE: STRUCT
1"
5" SEAMLESS PFSM GUTTER WITH
ROUND DOWN SPOUTS
RE: ROOF PLANS FOR LOCATIONS
PFSM DRIP EDGE
FLASHING
ASPHALT SHINGLE ROOF
RE: SPEC
HIGH TEMP ICE AND WATER SHIELD -
PROVIDE DOUBLE LAYER (50% OVERLAP)
FOR FIRST 4' OF ROOF ABOVE EAVE
RE: SPEC
EXISTING 5 1/2" X 14 1/2" GLU LAM BEAMS
2X10 FASCIA W/ 2X8 SHADOW BOARDS
EXISTING 1/2" PLYWOOD SHEATHING
3" INSULATION PANEL CONSISTING OF: 2 3/8"
RIGID FOAM GLUED TO 5/8" PLYWOOD
TYP. EXT. VERTICAL WOOD SIDING
3D DRAINAGE MEDIUM CONT. BEHIND STONE TO
AIR VENT MATERIAL @ T.O. VERTICAL WOOD
SIDING RE: SPEC.
1X6 DOUG-FIR T&G DECKING @ ALL SOFFITS
MATCH EXISTING OVERHANG TYPICAL
SLOPE TO MATCH EXISTING
2# CLOSED CELL SPRAY FOAM
INSULATION TO BE SPRAYED IN EXISTING
AIR SPACE BETWEEN EXISTING FRAMING
SPRAY FOAM TO BE FILLED OVER
EXISTING CAVITY THEN SCRAPED TO BE
FLUSH WITH EXISTING FRAMING
1/2" PLYWOOD SHEATHING
3/8" PLYWOOD SHEATHING
GRID
LINE
EXISTING 2X10 RAFTER @ 16" O.C.
EXISTING BLOCKING
EXISTING 2X4 RAFTERS STACKED
EXISTING PLYWOOD SHEATHING RE: STRUCT
1 1/4"
5" SEAMLESS PFSM GUTTER WITH
ROUND DOWN SPOUTS
RE: ROOF PLANS FOR LOCATIONS
PTSM DRIP EDGE
FLASHING
ASPHALT SHINGLE ROOF
RE: SPEC
HIGH TEMP ICE AND WATER SHIELD -
PROVIDE DOUBLE LAYER (50% OVERLAP)
FOR FIRST 4' OF ROOF ABOVE EAVE
RE: SPEC
2X12 FASCIA W/ 2X10 SHADOW BOARDS
EXISTING 1/2" PLYWOOD SHEATHING
3" INSULATION PANEL CONSISTING OF: 2 3/8"
RIGID FOAM GLUED TO 5/8" PLYWOOD
TYP. EXT. VERTICAL WOOD SIDING
3D DRAINAGE MEDIUM CONT. BEHIND STONE TO
AIR VENT MATERIAL @ T.O. VERTICAL WOOD
SIDING RE: SPEC.
1X6 DOUG-FIR T&G DECKING @ ALL SOFFITS
MATCH EXISTING OVERHANG TYPICAL
SLOPE TO MATCH EXISTING
2# CLOSED CELL SPRAY FOAM INSULATION
TO BE SPRAYED IN EXISTING AIR SPACE
BETWEEN EXISTING FRAMING
SPRAY FOAM TO BE FILLED OVER EXISTING
CAVITY THEN SCRAPED TO BE FLUSH WITH
EXISTING FRAMING
1/2" PLYWOOD SHEATHING
3/8" PLYWOOD SHEATHING
US Mail Only: P. O. Box 2378
Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Scale
Date
Drawn by
Checked by
Issue Date 8/26/2016 3:40:57 PM
1250 PTARMIGAN ROAD
VAIL VILLAGE SUB, LOT 3 & 4, PT OF
BLOCK 8, VAIL, CO
1 1/2" = 1'-0"
CROW RESIDENCE
A6.2
ROOF
DETAILS
August 26th, 2016
BKW
HB
August 26th, 2016
BUILDING PERMIT SET
1 1/2" = 1'-0"
3
TYPICAL ROOF RAKE DETAIL @ LIVING
ROOM
1 1/2" = 1'-0"
2
TYPICAL ROOF RIDGE DETAIL
1 1/2" = 1'-0"
1
TYPICAL ROOF EAVE DETAIL@ LIVING
ROOM
1 1/2" = 1'-0"
4
TYPICAL ROOF EAVE DETAIL @ EAST
SIDE OF HOME (BEDROOM)
REVISION SCHEDULE
# DESCRIPTION DATE
10/14/16