Loading...
HomeMy WebLinkAboutB16-0402_A6.2_1490108436.pdfGRID LINE 1" TYP. EXT. VERTICAL WOOD SIDING MATCH EXISTING OVERHANG TYPICAL EXISTING 5 1/2" X 14 1/2" GLULAM SEE 1/A6.2 FOR TYPICAL ROOF DETAIL NOTES SLOPE TO MATCH EXISTING SLOPE TO MATCH EXISTING EXISTING RIDGE BEAM RE: STRUCT ASPHALT SHINGLE ROOF RE:SPEC 1/2" PLYWOOD SHEATHING OVER SPRAY FOAM INSULATION HIGH TEMP ICE AND WATER SHIELD - CONTINUOUS @ ROOF AND OVER RIDGE RE: SPEC RIDGE CAP RE: SPEC. EXISTING WALL @ LIVING ROOM SEE 1/A6.2 FOR TYPICAL NOTES GRID LINE EXISTING 2X RAFTER @ 16" O.C. EXISTING BLOCKING EXISTING 2X4 RAFTERS STACKED EXISTING PLYWOOD SHEATHING RE: STRUCT 1" 5" SEAMLESS PFSM GUTTER WITH ROUND DOWN SPOUTS RE: ROOF PLANS FOR LOCATIONS PFSM DRIP EDGE FLASHING ASPHALT SHINGLE ROOF RE: SPEC HIGH TEMP ICE AND WATER SHIELD - PROVIDE DOUBLE LAYER (50% OVERLAP) FOR FIRST 4' OF ROOF ABOVE EAVE RE: SPEC EXISTING 5 1/2" X 14 1/2" GLU LAM BEAMS 2X10 FASCIA W/ 2X8 SHADOW BOARDS EXISTING 1/2" PLYWOOD SHEATHING 3" INSULATION PANEL CONSISTING OF: 2 3/8" RIGID FOAM GLUED TO 5/8" PLYWOOD TYP. EXT. VERTICAL WOOD SIDING 3D DRAINAGE MEDIUM CONT. BEHIND STONE TO AIR VENT MATERIAL @ T.O. VERTICAL WOOD SIDING RE: SPEC. 1X6 DOUG-FIR T&G DECKING @ ALL SOFFITS MATCH EXISTING OVERHANG TYPICAL SLOPE TO MATCH EXISTING 2# CLOSED CELL SPRAY FOAM INSULATION TO BE SPRAYED IN EXISTING AIR SPACE BETWEEN EXISTING FRAMING SPRAY FOAM TO BE FILLED OVER EXISTING CAVITY THEN SCRAPED TO BE FLUSH WITH EXISTING FRAMING 1/2" PLYWOOD SHEATHING 3/8" PLYWOOD SHEATHING GRID LINE EXISTING 2X10 RAFTER @ 16" O.C. EXISTING BLOCKING EXISTING 2X4 RAFTERS STACKED EXISTING PLYWOOD SHEATHING RE: STRUCT 1 1/4" 5" SEAMLESS PFSM GUTTER WITH ROUND DOWN SPOUTS RE: ROOF PLANS FOR LOCATIONS PTSM DRIP EDGE FLASHING ASPHALT SHINGLE ROOF RE: SPEC HIGH TEMP ICE AND WATER SHIELD - PROVIDE DOUBLE LAYER (50% OVERLAP) FOR FIRST 4' OF ROOF ABOVE EAVE RE: SPEC 2X12 FASCIA W/ 2X10 SHADOW BOARDS EXISTING 1/2" PLYWOOD SHEATHING 3" INSULATION PANEL CONSISTING OF: 2 3/8" RIGID FOAM GLUED TO 5/8" PLYWOOD TYP. EXT. VERTICAL WOOD SIDING 3D DRAINAGE MEDIUM CONT. BEHIND STONE TO AIR VENT MATERIAL @ T.O. VERTICAL WOOD SIDING RE: SPEC. 1X6 DOUG-FIR T&G DECKING @ ALL SOFFITS MATCH EXISTING OVERHANG TYPICAL SLOPE TO MATCH EXISTING 2# CLOSED CELL SPRAY FOAM INSULATION TO BE SPRAYED IN EXISTING AIR SPACE BETWEEN EXISTING FRAMING SPRAY FOAM TO BE FILLED OVER EXISTING CAVITY THEN SCRAPED TO BE FLUSH WITH EXISTING FRAMING 1/2" PLYWOOD SHEATHING 3/8" PLYWOOD SHEATHING US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Scale Date Drawn by Checked by Issue Date 8/26/2016 3:40:57 PM 1250 PTARMIGAN ROAD VAIL VILLAGE SUB, LOT 3 & 4, PT OF BLOCK 8, VAIL, CO 1 1/2" = 1'-0" CROW RESIDENCE A6.2 ROOF DETAILS August 26th, 2016 BKW HB August 26th, 2016 BUILDING PERMIT SET 1 1/2" = 1'-0" 3 TYPICAL ROOF RAKE DETAIL @ LIVING ROOM 1 1/2" = 1'-0" 2 TYPICAL ROOF RIDGE DETAIL 1 1/2" = 1'-0" 1 TYPICAL ROOF EAVE DETAIL@ LIVING ROOM 1 1/2" = 1'-0" 4 TYPICAL ROOF EAVE DETAIL @ EAST SIDE OF HOME (BEDROOM) REVISION SCHEDULE # DESCRIPTION DATE 03/21/17