HomeMy WebLinkAboutB16-0402_A6.3_1478904097.pdf5" PROVIDE BLOCKING AS REQ'D RE: STRUCT. 2" X 3/8" STEEL BOTTOM STRAP 2" X 3/8" STEEL TOP STRAP 3/8" X 3/8" METAL ROD 2 1/4" X 1/2" T STEEL STANCHION 2 1/4" MICROLAM JOISTS TO BE RIPPED AT 1/8" PER 1'-0" RE: STRUCT. 2'X2' BISON WOOD TILE DECK SYSTEM OVER BISON ADJUSTABLE PEDESTALS SLOPED AT 1/8" PER 1'-0" 2 1/2" X 1/2" METAL HAND RAIL 3/4" PLYWOOD SLOPED AT 1/8" PER 1'-0" W.P. MEMBRANE ADHERES TO PFSM FLASHING WHICH EXTENDS OVER EDGE WITH A DRIP EDGE AS SHOWN CONT. 6" W X 1/4" THICK STEEL PLATE WELDED TO STANCHIONS PROVIDE PFSM GUTTER BETWEEN RAILING AND EDGE OF DECK SEE PLANS FOR DOWN SPOUT LOCATIONS 5" W X 3 1/2" H X 3/4" T STEEL PLATE LAG BOLTED THROUGH SOLID BLOCKING 3 1/8" RIGID INSULATION PANEL 5/8" PLY OVER 2 1/2" FOAM RE: SPEC. 6 1/2" 3 1/2" FILL CAVITY W/ 2# CLOSED CELL SPRAY FOAM @ R6.6 PER INCH TO ACHIEVE R49 CONT. PROTECTION BOARD OVER W.P. MEMBRANE RE: SPEC OVER SLOPED PLYWOOD GENERAL NOTES: ALL EXPOSED STEEL PAINTED TO MATCH PROPOSED WINDOW COLOR 3 1/8" VARIES 5 1/4" 3 7/8" ELEVATION FOR REFERENCE 2' - 4 5/8" 3 7/8" 3' - 1" 3/4" 1 1/2" CONT. 6" W X 1/4" THICK STEEL PLATE WELDED TO STANCHIONS OPEN US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Scale Date Drawn by Checked by Issue Date 8/26/2016 3:41:19 PM 1250 PTARMIGAN ROAD VAIL VILLAGE SUB, LOT 3 & 4, PT OF BLOCK 8, VAIL, CO 3" = 1'-0" CROW RESIDENCE A6.3 DECK DETAILS August 26th, 2016 AH AG August 26th, 2016 BUILDING PERMIT SET 3" = 1'-0" 1 CROW RESIDENCE DECK AND RAILING DETAIL REVISION SCHEDULE # DESCRIPTION DATE 10/14/16