HomeMy WebLinkAboutB16-0402_A6.3_1490108437.pdf5" PROVIDE BLOCKING AS REQ'D
RE: STRUCT.
2" X 3/8" STEEL BOTTOM STRAP
2" X 3/8" STEEL TOP STRAP
3/8" X 3/8" METAL ROD
2 1/4" X 1/2" T STEEL STANCHION
2 1/4"
MICROLAM JOISTS TO BE RIPPED AT 1/8"
PER 1'-0" RE: STRUCT.
2'X2' BISON WOOD TILE DECK SYSTEM
OVER BISON ADJUSTABLE PEDESTALS
SLOPED AT 1/8" PER 1'-0"
2 1/2" X 1/2" METAL HAND RAIL
3/4" PLYWOOD SLOPED AT 1/8" PER 1'-0"
W.P. MEMBRANE ADHERES TO
PFSM FLASHING WHICH EXTENDS
OVER EDGE WITH A DRIP EDGE
AS SHOWN
CONT. 6" W X 1/4" THICK STEEL PLATE
WELDED TO STANCHIONS
PROVIDE PFSM GUTTER BETWEEN
RAILING AND EDGE OF DECK SEE
PLANS FOR DOWN SPOUT
LOCATIONS
5" W X 3 1/2" H X 3/4" T STEEL PLATE LAG
BOLTED THROUGH SOLID BLOCKING
3 1/8" RIGID INSULATION PANEL
5/8" PLY OVER 2 1/2" FOAM
RE: SPEC.
6 1/2"
3 1/2"
FILL CAVITY W/ 2# CLOSED CELL SPRAY FOAM
@ R6.6 PER INCH TO ACHIEVE R49
CONT. PROTECTION BOARD OVER W.P. MEMBRANE
RE: SPEC OVER SLOPED PLYWOOD
GENERAL NOTES:
ALL EXPOSED STEEL PAINTED TO MATCH PROPOSED WINDOW COLOR
3 1/8"
VARIES
5 1/4"
3 7/8" ELEVATION FOR REFERENCE
2' - 4 5/8"
3 7/8"
3' - 1"
3/4"
1 1/2"
CONT. 6" W X 1/4" THICK STEEL PLATE
WELDED TO STANCHIONS
OPEN
US Mail Only: P. O. Box 2378
Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Scale
Date
Drawn by
Checked by
Issue Date 8/26/2016 3:41:19 PM
1250 PTARMIGAN ROAD
VAIL VILLAGE SUB, LOT 3 & 4, PT OF
BLOCK 8, VAIL, CO
3" = 1'-0"
CROW RESIDENCE
A6.3
DECK
DETAILS
August 26th, 2016
AH
AG
August 26th, 2016
BUILDING PERMIT SET
3" = 1'-0"
1
CROW RESIDENCE DECK AND RAILING
DETAIL
REVISION SCHEDULE
# DESCRIPTION DATE
03/21/17