HomeMy WebLinkAboutB16-0402_A8.1_1478904109.pdfWINDOW RE: WINDOW SCHEDULE WINDOW SET IN BED OF SEALANT OVER BITUTHANE FLASHING MEMBRANE TYP. EXT. WOOD SIDING SEE A6.5 WATERPROOFING OVER AIR INFILTRATION BARRIER RE: SPEC. LAP SELF ADHERED BITUTHANE UNDER WINDOW SILL OVER 3D DRAINAGE MEDIUM WHICH IS OVER AIR AND WATER INFILTRATION BARRIER 3X3 CEDAR WOOD TRIM W/ TOP SCORED @ 1/4" : 1'-0" GRID LINE INTERIOR EXTERIOR EXISTING TRIM 2X8 BLOCKING WINDOW RE: WINDOW SCHEDULE WINDOW SET IN BED OF SEALANT OVER BITUTHANE FLASHING MEMBRANE TYP. EXT. STUCCO WALL ASSEMBLY LAP BITUTHANE MEMBRANE UNDER WINDOW SILL DOWN WALL OVER INSULATION PANEL AND OVER 3D DRAINAGE MEDIUM/ AIR INFILTRATION BARRIER GRID LINE INTERIOR EXTERIOR SEALANT JOINT PROVIDE BLOCKING AS NECESSARY EXISTING TRIM SEALANT JOINT AND BACKER ROD TYPICAL WINDOW SILL @ STUCCO NOTES: PROVIDE WEEP SCREED @ STUCCO TYP. 3X3 CEDAR WOOD TRIM W/ TOP SCORED @ 1/4" : 1'-0" WINDOW RE: WINDOW SCHEDULE FOAM INSULATION AND SHIM AS REQ'D LAP BUILDING PAPER OVER 1ST LAYER OF WATERPROOF MEMBRANE 2ND LAYER OF SELF ADHERED BITUTHANE FLASHING OVER 1ST LAYER AND OVER 3D DRAINAGE / AIR AND WATER INFILTRATION BARRIER GRID LINE INTERIOR EXTERIOR WOOD JAMB EXTENSION 1ST LAYER OF SELF ADHERED BITUTHANE FLASHING LAPS OVER NAILING FLANGE CONTINUOUS BEHIND WOOD TRIM SEALANT JOINT AND BACKER ROD EXISTING TRIM 2X4 BLOCKING 3X3 CEDAR TRIM WINDOW RE: WINDOW SCHEDULE FOAM INSULATION AND SHIM AS REQ'D LAP BUILDING PAPER OVER 1ST LAYER OF WATERPROOF MEMBRANE 2ND LAYER OF SELF ADHERED BITUTHANE FLASHING OVER 1ST LAYER AND OVER 3D DRAINAGE / AIR AND WATER INFILTRATION BARRIER GRID LINE INTERIOR EXTERIOR WOOD JAMB EXTENSION 1ST LAYER OF SELF ADHERED BITUTHANE FLASHING LAPS OVER NAILING FLANGE CONTINUOUS BEHIND WOOD TRIM SEALANT JOINT AND BACKER ROD EXISTING TRIM 2X4 BLOCKING 3X3 CEDAR TRIM WINDOW RE: WINDOW SCHEDULE FOAM INSULATION AND SHIM AS REQ'D TYP. EXT. VERTICAL WOOD SIDING 3D DRAINAGE MEDIUM/ AIR INFILTRATION BARRIER LAPS FLASHING SUCH THAT WALL CAN DRAIN RE: SPEC LAP SELF ADHERED BITUTHANE FLASHING OVER MTL. FLASHING AND CONTINUE UP OVER INSULATION PANEL MIN 8" AND UNDER UPPER FLASHING AND 3D DRAINAGE MEDIUM GRID LINE INTERIOR EXTERIOR PFSM FLASHING HEADER RE: STRUCT. SELF ADHERED BITUTHANE FLASHING LAPS OVER PFSM FLASHING WEEP SCREED FLASHING TO MATCH WINDOW COLOR TYPICAL WINDOW HEADER NOTES @ WOOD SIDING EXISTING TRIM SELF ADHERED BITUTHANE FLASHING LAPS OVER NAILING FLANGE 3X3 CEDAR TRIM WINDOW RE: WINDOW SCHEDULE FOAM INSULATION AND SHIM AS REQ'D TYP. EXT. STUCCO WALL 3D DRAINAGE MEDIUM/ AIR INFILTRATION BARRIER LAPS FLASHING SUCH THAT WALL CAN DRAIN RE: SPEC LAP SELF ADHERED BITUTHANE FLASHING OVER MTL. FLASHING AND CONTINUE UP OVER INSULATION PANEL MIN 8" AND UNDER UPPER FLASHING AND 3D DRAINAGE MEDIUM GRID LINE INTERIOR EXTERIOR PFSM FLASHING HEADER RE: STRUCT. SELF ADHERED BITUTHANE FLASHING LAPS OVER PFSM FLASHING WEEP SCREED FLASHING TO MATCH WINDOW COLOR TYPICAL WINDOW HEADER NOTES @ STUCCO EXISTING TRIM SELF ADHERED BITUTHANE FLASHING LAPS OVER NAILING FLANGE 3X3 CEDAR TRIM CUSTOM DOOR RE: DOOR SCHEDULE SEE A4.2 FOR ELEVATION 3D DRAINAGE MEDIUM/ AIR INFILTRATION BARRIER LAPS FLASHING SUCH THAT WALL CAN DRAIN RE: SPEC LAP SELF ADHERED BITUTHANE FLASHING OVER MTL. FLASHING AND CONTINUE UP OVER INSULATION PANEL MIN 8" AND UNDER UPPER FLASHING AND 3D DRAINAGE MEDIUM GRID LINE INTERIOR EXTERIOR HEADER RE: STRUCT. FLASHING TO MATCH WINDOW COLOR SELF ADHERED BITUTHANE FLASHING LAPS OVER NAILING FLANGE BLOCKING AS REQ'D CUSTOM DOOR JAMB AND EXTENSION W/ TRIM 4" STONE VENEER METAL C-CHANNEL PRESSURE TREATED BLOCKING BEHIND C-CHANNEL 1 1/2" 5" 1/2" EXTERIOR INTERIOR CUSTOM DOOR SEE A4.2 FOR ELEVATION CUSTOM WOOD DOOR JAMB (1) 1 3/4" X 5.5" LVL MICROLAMS SEALANT 2 3/4" 3/8" GRID LINE SPRAY FOAM GAP AND SHIM AS REQ. TYP. CUSTOM 4/4" WOOD JAMB EXTENSION W/ WOOD TRIM WOOD TRIM DOOR SET OVER CUSTOM BED OF SEALANT AND FLASHING. RE: SPEC AND DOOR SCHEDULE W.P. MEMBRANE CONTINUOUS UNDER DOOR SILL RE: SPEC METAL FLASHING CONTINUOUS UNDER DOOR SILL AND TURN UP 1/2" @ FINISHED FLOOR RE: SPEC EXISTING STONE ASSEMBLY INTERIOR EXTERIOR CUSTOM DOOR RE: DOOR SCHEDULE SEE A4.2 FOR ELEVATION US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Scale Date Drawn by Checked by Issue Date 8/26/2016 3:42:10 PM 1250 PTARMIGAN ROAD VAIL VILLAGE SUB, LOT 3 & 4, PT OF BLOCK 8, VAIL, CO 3" = 1'-0" CROW RESIDENCE A8.1 WINDOW AND DOOR DETAILS August 26th, 2016 AH AG August 26th, 2016 BUILDING PERMIT SET 3" = 1'-0" 1 WINDOW SILL DETAIL @ WOOD SIDING 3" = 1'-0" 4 WINDOW SILL DETAIL @ STUCCO SIDING 3" = 1'-0" 5 WINDOW JAMB DETAIL @ STUCCO SIDING 3" = 1'-0" 2 WINDOW JAMB DETAIL @ WOOD SIDING 3" = 1'-0" 3 WINDOW HEADER DETAIL @ VERTICAL SIDING 3" = 1'-0" 6 WINDOW HEADER DETAIL @ STUCCO 3" = 1'-0" 7 FRONT DOOR HEADER DETAIL 3" = 1'-0" 8 FRONT DOOR JAMB DETAIL 3" = 1'-0" 9 FRONT DOOR SILL DETAIL REVISION SCHEDULE # DESCRIPTION DATE 10/14/16