HomeMy WebLinkAboutB16-0444_16077-Comcheck Report-122016_1484001180.pdfCOMcheck Software Version 4.0.5.1
Mechanical Compliance Certificate
Project Title:
2015 IECC
Project Type: Alteration
Location:
Aspen, Colorado
Climate Zone:
7
Construction Site:
616 W Lionshead Circle
Vail, CO 81657
Owner/Agent:
Christopher McKenzie
Expert Burger
616 W Lionshead Circle
Vail, CO 81657
chefmckenzie@hotmail.com
Designer/Contractor:
Joey Brenner
Rader Engineering
40690 Hwy 6
Suite E-1
Avon, CO 81620
970-845-7910
joey@raderengineering.com
Project Information
Energy Code:
Expert Burger
Mechanical Systems List
Quantity System Type & Description
Split System Heat Pump
Heating Mode: Capacity = 40 kBtu/h,
Proposed Efficiency = 9.50 HSPF, Required Efficiency = 8.20 HSPF
Cooling Mode: Capacity = 36 kBtu/h,
Proposed Efficiency = 18.50 SEER, Required Efficiency: 14.00 SEER
Fan System: None
1 HP-1 Heat Pump (Multiple-Zone):
Mechanical Compliance Statement
Compliance Statement: The proposed mechanical alteration project represented in this document is consistent with the building
plans, specifications, and other calculations submitted with this permit application. The proposed mechanical systems have been
designed to meet the 2015 IECC requirements in COMcheck Version 4.0.5.1 and to comply with any applicable mandatory
requirements listed in the Inspection Checklist.
Name - Title Signature Date
Project Title:
Data filename:
Expert Burger
J:\Jobs\2016 - Jobs\16077.00 - Expert Burger\Mechanical\Calculations\Comcheck\16077-
Comcheck.cck
12/20/16
Report date:
9
1 of Page
Joey Brenner 12/20/16
12/20/16
01/09/17
Inspection Checklist
Requirements: 100.0% were addressed directly in the COMcheck software
COMcheck Software Version 4.0.5.1
Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Energy Code: 2015 IECC
Section
#
& Req.ID
Plan Review Complies? Comments/Assumptions
C103.2
[PR2]1
Plans, specifications, and/or
calculations provide all information
with which compliance can be
determined for the mechanical
systems and equipment and
document where exceptions to the
standard are claimed. Load
calculations per acceptable
engineering standards and
handbooks.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
Additional Comments/Assumptions:
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title:
Data filename:
Expert Burger
J:\Jobs\2016 - Jobs\16077.00 - Expert Burger\Mechanical\Calculations\Comcheck\16077-
Comcheck.cck
12/20/16
Report date:
9
2 of Page
01/09/17
Section
#
& Req.ID
Footing / Foundation Inspection Complies? Comments/Assumptions
C403.2.4.
5,
C403.2.4.
6
[FO9]3
Snow/ice melting system sensors for
future connection to controls. Freeze
protection systems have automatic
controls installed.
Complies
Does Not
Not Observable
Not Applicable
Exception: Requirement does not apply.
Additional Comments/Assumptions:
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title:
Data filename:
Expert Burger
J:\Jobs\2016 - Jobs\16077.00 - Expert Burger\Mechanical\Calculations\Comcheck\16077-
Comcheck.cck
12/20/16
Report date:
9
3 of Page
01/09/17
Section
#
& Req.ID
Plumbing Rough-In Inspection Complies? Comments/Assumptions
C404.5,
C404.5.1,
C404.5.2
[PL6]3
Heated water supply piping conforms
to pipe length and volume
requirements. Refer to section details.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
C404.6.3
[PL7]3
Pumps that circulate water between a
heater and storage tank have controls
that limit operation from startup to
<= 5 minutes after end of heating
cycle.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
C404.7
[PL8]3
Water distribution system that pumps
water from a heated-water supply
pipe back to the heated-water source
through a cold-water supply pipe is a
demand recirculation water system.
Pumps within this system have
controls that start the pump upon
receiving a signal from the action of a
user of a fixture or appliance and
limits the temperature of the water
entering the cold-water piping to
104°F.
Complies
Does Not
Not Observable
Not Applicable
Exception: Requirement does not apply.
Additional Comments/Assumptions:
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title:
Data filename:
Expert Burger
J:\Jobs\2016 - Jobs\16077.00 - Expert Burger\Mechanical\Calculations\Comcheck\16077-
Comcheck.cck
12/20/16
Report date:
9
4 of Page
01/09/17
Section
#
& Req.ID
Mechanical Rough-In Inspection Complies? Comments/Assumptions
C402.2.6
[ME41]3
Thermally ineffective panel surfaces of
sensible heating panels have
insulation >= R-3.5.
Complies
Does Not
Not Observable
Not Applicable
Exception: Requirement does not apply.
C403.2.12
.1
[ME65]3
HVAC fan systems at design
conditions do not exceed allowable
fan system motor nameplate hp or fan
system bhp.
Complies
Does Not
Not Observable
Not Applicable
Exception: Requirement does not apply.
See the Mechanical Systems list for values.
C403.2.12
.3
[ME117]2
Fans have efficiency grade (FEG) >=
67. The total efficiency of the fan at
the design point of operation <= 15%
of maximum total efficiency of the
fan.
Complies
Does Not
Not Observable
Not Applicable
Exception: Single fans with motor nameplate horsepowerof =
5 hp.
C403.2.13
[ME71]2
Unenclosed spaces that are heated
use only radiant heat.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
C403.2.3
[ME55]2
HVAC equipment efficiency verified. Complies
Does Not
Not Observable
Not Applicable
See the Mechanical Systems list for values.
C403.2.4.
4
[ME112]3
Zone isolation devices and controls
installed where applicable.
Complies
Does Not
Not Observable
Not Applicable
Exception: Exhaust and outdoor air connections having fan
systems 5000 cfm or smaller.
C403.2.6.
1
[ME59]1
Demand control ventilation provided
for spaces >500 ft2 and >25
people/1000 ft2 occupant density and
served by systems with air side
economizer, auto modulating outside
air damper control, or design airflow
>3,000 cfm.
Complies
Does Not
Not Observable
Not Applicable
Exception: Requirement does not apply.
C403.2.6.
2
[ME115]3
Enclosed parking garage ventilation
has automatic contaminant detection
and capacity to stage or modulate
fans to 50% or less of design capacity.
Complies
Does Not
Not Observable
Not Applicable
Exception: Requirement does not apply.
C403.2.7
[ME57]1
Exhaust air energy recovery on
systems meeting Table C403.2.7(1)
and C403.2.7(2).
Complies
Does Not
Not Observable
Not Applicable
Exception: Requirement does not apply.
C403.2.8
[ME116]3
Kitchen exhaust systems comply with
replacement air and conditioned
supply air limitations, and satisfy hood
rating requirements and maximum
exhaust rate criteria.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
C403.2.9
[ME60]2
HVAC ducts and plenums insulated.
Where ducts or plenums are installed
in or under a slab, verification may
need to occur during Foundation
Inspection.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
C403.2.9
[ME10]2
Ducts and plenums sealed based on
static pressure and location.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title:
Data filename:
Expert Burger
J:\Jobs\2016 - Jobs\16077.00 - Expert Burger\Mechanical\Calculations\Comcheck\16077-
Comcheck.cck
12/20/16
Report date:
9
5 of Page
01/09/17
Section
#
& Req.ID
Mechanical Rough-In Inspection Complies? Comments/Assumptions
C403.2.9.
1.3
[ME11]3
Ductwork operating >3 in. water
column requires air leakage testing.
Complies
Does Not
Not Observable
Not Applicable
Exception: Requirement does not apply.
C403.4.1.
1
[ME75]2
Hydronic and multizone HVAC system
controls areVAV fans driven by
mechanical or electrical variable
speed drive per Table C403.4.1.1.
Complies
Does Not
Not Observable
Not Applicable
Exception: Requirement does not apply.
C403.4.1.
2
[ME67]2
VAV fans have static pressure sensors
located so controller setpoint <=1.2
w.c..
Complies
Does Not
Not Observable
Not Applicable
Exception: Requirement does not apply.
C403.4.1.
3
[ME24]2
Reset static pressure setpoint for DDC
controlled VAV boxes reporting to
central controller based on the zones
requiring the most pressure.
Complies
Does Not
Not Observable
Not Applicable
Exception: Requirement does not apply.
C403.4.2.
3.2.2
[ME122]3
Open- or closed circuit cooling towers
have a separate heat exchanger to
isolate the cooling tower from the
heat pump loop, and heat loss is
controlled by shutting down the
circulation pump on the cooling tower
loop.
Complies
Does Not
Not Observable
Not Applicable
Exception: Requirement does not apply.
C403.4.4.
6
[ME110]3
Multiple zone VAV systems with DDC
of individual zone boxes have static
pressure setpoint reset controls.
Complies
Does Not
Not Observable
Not Applicable
Exception: Requirement does not apply.
See the Mechanical Systems list for values.
C408.2.2.
1
[ME53]3
Air outlets and zone terminal devices
have means for air balancing.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
Additional Comments/Assumptions:
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title:
Data filename:
Expert Burger
J:\Jobs\2016 - Jobs\16077.00 - Expert Burger\Mechanical\Calculations\Comcheck\16077-
Comcheck.cck
12/20/16
Report date:
9
6 of Page
01/09/17
Section
#
& Req.ID
Final Inspection Complies? Comments/Assumptions
C303.3,
C408.2.5.
3
[FI8]3
Furnished O&M manuals for HVAC
systems within 90 days of system
acceptance.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
C403.2.2
[FI27]3
HVAC systems and equipment
capacity does not exceed calculated
loads.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
C403.2.4.
1
[FI47]3
Heating and cooling to each zone is
controlled by a thermostat control.
Minimum one humidity control device
per installed
humidification/dehumidification
system.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
C403.2.4.
1.1
[FI42]3
Heat pump controls prevent
supplemental electric resistance heat
from coming on when not needed.
Complies
Does Not
Not Observable
Not Applicable
Exception: Requirement does not apply.
C403.2.4.
1.2
[FI38]3
Thermostatic controls have a 5 °F
deadband.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
C403.2.4.
1.3
[FI20]3
Temperature controls have setpoint
overlap restrictions.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
C403.2.4.
2
[FI39]3
Each zone equipped with setback
controls using automatic time clock or
programmable control system.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
C403.2.4.
2.1,
C403.2.4.
2.2
[FI40]3
Automatic Controls: Setback to 55°F
(heat) and 85°F (cool); 7-day clock, 2-
hour occupant override, 10-hour
backup
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
C408.2.1
[FI28]1
Commissioning plan developed by
registered design professional or
approved agency.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
C408.2.3.
1
[FI31]1
HVAC equipment has been tested to
ensure proper operation.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
C408.2.3.
2
[FI10]1
HVAC control systems have been
tested to ensure proper operation,
calibration and adjustment of controls.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
C408.2.4
[FI29]1
Preliminary commissioning report
completed and certified by registered
design professional or approved
agency.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title:
Data filename:
Expert Burger
J:\Jobs\2016 - Jobs\16077.00 - Expert Burger\Mechanical\Calculations\Comcheck\16077-
Comcheck.cck
12/20/16
Report date:
9
7 of Page
01/09/17
Section
#
& Req.ID
Final Inspection Complies? Comments/Assumptions
C408.2.5.
1
[FI7]3
Furnished HVAC as-built drawings
submitted within 90 days of system
acceptance.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
C408.2.5.
3
[FI43]1
An air and/or hydronic system
balancing report is provided for HVAC
systems.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
C408.2.5.
4
[FI30]1
Final commissioning report due to
building owner within 90 days of
receipt of certificate of occupancy.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
Additional Comments/Assumptions:
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title:
Data filename:
Expert Burger
J:\Jobs\2016 - Jobs\16077.00 - Expert Burger\Mechanical\Calculations\Comcheck\16077-
Comcheck.cck
12/20/16
Report date:
9
8 of Page
01/09/17
Project Title:
Data filename:
Expert Burger
J:\Jobs\2016 - Jobs\16077.00 - Expert Burger\Mechanical\Calculations\Comcheck\16077-
Comcheck.cck
12/20/16
Report date:
9
9 of Page
01/09/17