Loading...
HomeMy WebLinkAboutB16-0444_4-H2.1_1484002828.pdf9 10 11 8 7 PERMIT COMMENTS RESPONSE: B009 - Please provide gas pipe sizing for alternate tankless water heater(s). RESPONSE: PLEASE REFER TO "PRICING ALTERNATES" ON SHEET M1.0 FOR ALTERNATE GAS PIPING SIZES. B010 - Please verify that walls comply with section 507.2.6 of the 2015 IMC. RESPONSE: PLEASE REFER TO CAPTIVE AIRE DRAWINGS. HOOD IS BEING FURNISHED AS "FULLY INSULATED" AND IS LISTED FOR CLEARANCE TO COMBUSTIBLES OF ZERO INCHES. B011 - Please provide distance measurement from all rooftop equipment to roof edge per section 1015.6 of the 2015 IBC. RESPONSE: KEF-1 KITCHEN EXHAUST FAN = 7'-5" MAU-1 MAKE-UP AIR UNIT = 12'-3" HP-1 HEAT PUMP = 13'-4" (UPPER ROOF) 2'-8" (LOWER ROOF) B012 - Structural engineer to analyze roof structure for the addition of mechanical equipment - please provide engineering analysis. RESPONSE: STRUCTURAL ENGINEERING SERVICES TO BE PROVIDED BY OWNER. MAIN LEVEL HVAC PLAN SCALE: 1/4" = 1'-0" ROOF LEVEL HVAC PLAN SCALE: 1/4" = 1'-0" BASEMENT LEVEL HVAC PLAN SCALE: 1/4" = 1'-0" 12/20/16 01/09/17