HomeMy WebLinkAboutB16-0444_A2-05_1484002826.pdf2 3
C C
D
3' - 0 1/8" 3' - 0" 10' - 7 1/2"
10' - 11 1/8" 2' - 0 1/2"
4' - 2 1/2" 8' - 0" 3' - 0" 1' - 3 5/8"
7' - 6 1/2" 10' - 10"
8' - 1"
4' - 7 1/8" 3 5/8"
1' - 6 1/8"
3 5/8" 2' - 2 1/8" 10' - 9 1/2" 3 5/8" 6' - 2 5/8" 3 5/8" 3' - 11 3/8"
6' - 0"
5 5/8" 10' - 0 3/4" 2' - 4 1/8"
1' - 10 1/2"
2' - 6 1/2" 10
A2.01
W4-4
W4-4
W4-4
W4-4
W4-4
W4-4
5/8" GYPSUM
WALL BOARD
3 5/8"
W3-4
3 5/8" METAL STUD,
SEE PLANS AND WALL TAG
FOR STUD SIZE, TYP.
SOUND BATTS
5/8" GYPSUM
WALL BOARD
6"
W3-6
6" METAL STUD,
SEE PLANS AND WALL TAG
FOR STUD SIZE, TYP.
SOUND BATTS
GENERAL ASSEMBLY AND FINISH SYSTEMS
WALL SYSTEMS:
Note: Reference structural drawings and specifications for all fasteners within all building assemblies including but not limited to nails, screws & bolts for size
(length, diameter & shank), type, style & spacing. Contact Architect with any discrepancies prior to ordering and installation of product in assembly. All products are
to be installed in strict conformance with product specifications, requirements and warranties. Contact Architect with any discrepancies prior to ordering product.
Refer to both architectural and structural drawings for assembly information. Structural drawings shall govern over architectural drawings regarding framing.
Architectural drawings shall govern over structural drawings regarding wall location dimensions, fire, sound and weather proofing related details. Contact Architect
immediately with any discrepancy prior to installation of the work. Install all fire rated assemblies per their listings as referenced with options shown. The following
assembly narratives are general.
Refer to Structural Drawings for Bearing Walls and Shear Walls.
Structural for size and spacing of studs and sheathing).
NON-RATED ASSEMBLIES (INTERIOR):
W4-*** GYPSUM BOARD PARTITION ON 2x METAL STUDS
(Non-Rated)
(1) Layer 5/8" gypsum board**** on each side of 2x metal studs at non-bearing walls demising bedrooms
and living areas. Sound batt insulation. (Re. Structural for size and spacing).
1650 Fallridge Road, Suite C-1
Vail, Colorado 81657
f.(970) 476-4901 p.(970)476-6342
616 W LIONSHEAD
CIRCLE
VAIL,
COLORADO
81657
A2.05
FRAMING
PLAN
EXPERT
BURGER
Project #: 1642
10/13/16
PERMIT SET
1/2" = 1'-0"
1
MAIN LEVEL - FRAMING PLAN
1 1/2" = 1'-0"
2
WALL ASSEMBLY W3-4 - 3 5/8" METAL
STUD INTERIOR PARTITION
1 1/2" = 1'-0"
3
WALL ASSEMBLY W3-6 - 6" METAL STUD
INTERIOR PARTITION
01/09/17