B16-0449_Submittal Binder_1477001700.pdf
M-SERIES Specifications are subject to change without notice. © 2016 Mitsubishi Electric US, Inc. Job Name: System Reference:Date: SUBMITTAL DATA: MXZ-4C36NA2 MULTI-INDOOR INVERTER HEAT-PUMP SYSTEM Specifications Model Name Unit Type MXZ-4C36NA2 Cooling* (Non-ducted / Ducted) Rated Capacity Btu/h 35,400 / 34,400 Capacity Range Btu/h 12,600-36,400 / 12,600-34,800 Rated Total Input W 3,760 / 3,940 Heating at 47°F* (Non-ducted / Ducted) Rated Capacity Btu/h 36,000 / 34,400 Capacity Range Btu/h 11,400-43,000 / 11,400-41,400 Rated Total Input W 3,020 / 3,100 Heating at 17°F* (Non-ducted/Ducted) Rated Capacity Btu/h 22,200 / 20,300 Rated Total Input W 3,340 / 3,450 Electrical Requirements Power Supply Voltage, Phase, Hertz 208 / 230V, 1-Phase, 60 Hz Recommended Fuse/Breaker Size A 25 MCA A 22.1 Voltage Indoor - Outdoor S1-S2 V AC 208 / 230 Indoor - Outdoor S2-S3 V DC ±24 Compressor INVERTER-driven Scroll Hermetic Fan Motor (ECM)F.L.A.2.43 Sound Pressure Level Cooling dB(A)54 Heating 56 External Dimensions (H x W x D)In (mm)31-11/32 x 37-13/32 x 13 (796 x 950 x 330) Net Weight Lbs (kg)139 (63) External Finish Munsell 3.0Y 7.8/1.1 Refrigerant Pipe Size O.D. ― Eight Ports Liquid (High Pressure)In (mm)1/4 (12.7) Gas (Low Pressure)A: 1/2 (6.35) ; B,C,D: 3/8 (9.52) Max. Refrigerant Line Length Ft (m)230 (70) Max. Piping Length for Each Indoor Unit Ft (m)82 (25) Max. Refrigerant Pipe Height Difference If IDU is Above ODU Ft (m)49 (15) If IDU is Below ODU 49 (15) Connection Method Flared/Flared Refrigerant R410A ACCESSORIES □3/8" x 1/2" Port Adapter (MAC-A454JP) □1/2" x 3/8" Port Adapter (MAC-A455JP) □1/2" x 5/8" Port Adapter (MAC-A456JP) □1/4" x 3/8" Port Adapter (PAC-493PI) □3/8" x 5/8" Port Adapter (PAC-SG76RJ) □M-NET Adapter (PAC-IF01MNT-E) □Base Heater (PAC-645BH-E) Outdoor Unit: MXZ-4C36NA2 (For data on specific indoor units, see the MXZ-C Technical and Service Manual.) * Rating Conditions per AHRI Standard: Cooling | Indoor: 80º F (27º C) DB / 67º F (19º C) WB Cooling | Outdoor: 95º F (35º C) DB / 23.9° C (75° F) WB Heating at 47ºF | Indoor: 70º F (21º C) DB / 60º F (16º C) WB Heating at 47ºF | Outdoor: 47º F (8º C) DB / 43º F (6º C) WB Heating at 17º F | Indoor: 70º F (21º C) DB Heating at 17º F | Outdoor: 17º F (-8º C) DB / 15º F (-9º C) WB Specifications are subject to change without notice. © 2016 Mitsubishi Electric US, Inc. Notes: SPECIFICATIONS: MXZ-4C36NA2, contd. • Minimum of two Indoor Units must be connected to the MXZ-4C36NA2.• Minimum installed capacity cannot be less than 12,000 Btu/h. • Total connected capacity must not exceed 130% of outdoor unit capacity.• System can operate with only one Indoor Unit turned on. • Information provided at 208/230V. • For Reference: - MXZ-C Technical & Service Manual for detailed specifications and additional information per Indoor Unit Combination. - MXZ Series Multi-Zone Indoor/Outdoor Combination Table for allowed unit combinations. Indoor Unit Type SEER EER HSPF COP @ 47°F COP @ 17°F Non-ducted 19.2 9.4 11.0 3.50 2.67 Ducted and Non-ducted 17.6 9.05 10.4 3.38 2.61 Ducted 16.0 8.7 9.8 3.25 2.54 Outdoor Cooling 14 to 115° F (−10 to 46° C) DB Heating 5 to 65° F (−15 to 18° C) WB • Only 1 MVZ may be used on any system.• When an MVZ is connected, total connected capacity must be 100% or less. • When an MVZ is connected, no P-Series indoor units can be used (PCA, PLA, or PEAD). ENERGY EFFICIENCIES: NOTES: OPERATING RANGE: MVZ CONNECTION RULES: 1340 Satellite Boulevard. Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com Specifications are subject to change without notice. © 2016 Mitsubishi Electric US, Inc. FORM# MXZ-4C36NA2 for Multiple Indoor Unit Styles - 201605 DIMENSIONS: MXZ-4C36NA2 14 MXZ-4C36NA Unit: inch (mm) Lock nut Conduit plates Conduit connector OBH702A Unit: inch (mm) M-SERIES Specifications are subject to change without notice. © 2016 Mitsubishi Electric US, Inc. Job Name: System Reference:Date: SUBMITTAL DATA: SLZ-KA09NA & SUZ-KA09NA 9,000 BTU/H CEILING-CASSETTE HEAT-PUMP SYSTEMS Indoor Unit: SLZ-KA09NA Outdoor Unit: SUZ-KA09NA GENERAL FEATURES• Four-way 2'x2' ceiling-cassette indoor unit for ceiling recessed applications• Built-in drain mechanism for condensate removal; lifts to 19-11/16"• Wide air-flow pattern for better air distribution• Design features ventilation air intake knockout• Long-life air filter included with indoor unit• Indoor unit powered from outdoor unit using A-Control• Choice of fan speed: Low, Medium, High• Automatic restart following a power outage• Limited warranty: five years parts and seven years compressors SPECIFICATIONS Cooling1 Rated Capacity...................................8,400 Btu/hMinimum to Maximum Capacity Range .........3,100 - 10,900 Btu/hSEER .........................................15.0 Btu/h/WEER ..........................................12.0 Btu/h/WTotal Input...........................................700 W Heating at 47°F2 Rated Capacity..................................10,900 Btu/hMinimum to Maximum Capacity Range .........3,100 - 14,100 Btu/hHSPF ..........................................9.6 Btu/h/WCOP .................................................3.44Total Input...........................................930 W Heating at 17°F3 Rated Capacity...................................6,200 Btu/hRated Total Input .....................................740 WCOP .................................................2.46Maximum Capacity**...............................6,200 Btu/hMaximum Total Input .................................1,040 W ENERGY STAR®.....................................YesENERGY STAR products are third-party certified by an EPA-recognized Certification Body. Electrical RequirementsPower Supply ....................208 / 230V, 1-Phase, 60 HzRecommended Fuse/Breaker Size.......................15 A VoltageIndoor - Outdoor S1-S2 .......................AC 208 / 230VIndoor - Outdoor S2-S3 ...........................DC ±24V OPERATING CONDITIONS Indoor Intake Air Temp.Outdoor Intake Air Temp. Cooling4 Maximum 90° F (32° C) DB 73° F (23° C) WB 115° F (46° C) DB Minimum 67° F (19° C) DB 57° F (14° C) WB 14° F (-10° C) DB Heating Maximum 80° F (27° C) DB 67° F (19° C) WB 75° F (24° C) DB 65° F (18° C) WB Minimum 70° F (21° C) DB 60° F (16° C) WB -4° F (-20° C) DB -5° F (-21° C) WB5 4 Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions.5 System cuts out at -9º F (-27º C) to avoid thermistor error and automatically restarts at -4º F (-20º C). Indoor UnitMCA ...............................................1 AFan Motor Output ...................................15 WFan Motor (ECM) ...............................0.23 F.L.A.Airflow (Lo - Med - Hi)................280 - 320 - 350 Dry CFM250 - 290 - 320 Wet CFMAir Filter .........................Polypropylene HoneycombSound Pressure Level (Lo - Med - Hi) .........29 - 32 - 38 dB(A) DIMENSIONS UNIT INCHES / MM GRILLE INCHES / MM W 22-7/16 / 570 25-5/8 / 650 D 22-7/16 / 570 25-5/8 / 650 H 9-1/4 / 235 13/16 / 20 Weight (Unit/Grille) Lbs.............................................36 / 7 kg............................................16.5 / 3External Finish (Unit/Grille) ..........Galvanized-steel Sheets / Munsell 6.4Y 8.9 / 0.4Field Drainpipe Size O.D.......................1-1/4" / 32 mm Outdoor UnitCompressor .............................DC Inverter-drivenMCA ..............................................12 AMOCP.............................................15 AFan Motor (ECM) ...............................0.50 F.L.A.Sound Pressure Level Cooling ......................................46 dB(A) Heating ......................................50 dB(A) DIMENSIONS INCHES / MM W 31-1/2 / 800 D 11-1/4 / 285 H 21-5/8 / 550 Weight ....................................66 lbs. / 30 kgExternal Finish ......................Munsell No. 3Y 7.8 / 1.1Refrigerant Type...................................R410ARefrigerant Pipe Size O.D. Gas Side .................................3/8" / 9.52 mm Liquid Side................................1/4" / 6.35 mmMax. Refrigerant Pipe Length......................65' / 19 mMax. Refrigerant Pipe Height Difference .............40' / 12 mConnection Method ................................Flared 1 Cooling | Indoor: 80º F (27º C) DB / 67º F (19º C) WB* 1 Cooling | Outdoor: 95º F (35º C) DB / 75º F (24º C) WB* 2 Heating at 47º F | Indoor: 70º F (21º C) DB / 60º F (16º C) WB* 2 Heating at 47º F | Outdoor: 47º F (8º C) DB / 43º F (6º C) WB* 3 Heating at 17º F | Indoor: 70º F (21º C) DB / 60º F (16º C) WB* 3 Heating at 17º F | Outdoor: 17º F (-8º C) DB / 15º F (-9º C) WB* * Rating Conditions per AHRI Standard ** Maximum Capacity is at full speed and performance for INVERTER-driven System. ACCESSORIESIndoor Unit □Condensate Pump (BlueDiamond X87-711/721; 115/230V) □Condensate Pump (Sauermann SI30-115/230; 115/230V) □Grille (SLP-15AAUW; required - shipped with unit) Outdoor Unit □Three-pole Disconnect Switch (TAZ-MS303) □Air Outlet Guide (MAC-889SG) □Mounting Base (DSD-400P) □Mounting Pad (ULTRILITE1) □Wall Mounting Bracket (QSWB2000M-1) Controller Options □Wireless Controller (MHK1) □Wired Remote Controller (PAR-32MAA-J) □Wireless Interface for kumo cloud™ (PAC-WHS01WF-E) □Thermostat Interface (PAC-US444CN-1) □Hand-held Wireless Remote Controller (PAR-FL32MA; req.PAR-FA32MA-E) □Wireless Signal Receiver Module PAR-FA32MA (for PAR-FL32MA-E) Specifications are subject to change without notice. © 2016 Mitsubishi Electric US, Inc. DIMENSIONS: SLZ-KA09NA SLZ-KA15NA SLZ-KA12NA SLZ-KA09NA Models ( 6.35mm)flared connection Refrigerent pipe(liquid)Refrigerent pipe(gas) ( 9.52mm)flared connection 3/8 inch Detail drawing of fresh air intake Ceiling surface Cut out hole2-7/8(73.4) Burring hole3-1/8(2.8) 3-15/16(100)4-21/32(118)1(25)120120+5 0(27 )+3/16 01-1/1619/32~1-15/32(15~37)19/32~1-15/32(15~37)22-11/16~24-13/32(576~620) 22-7/16(570) 20-7/8(530) Grille Fresh airintake Drain pipeVP-25 connection(O.D.1-1/4(32)) Vane motor Drain hole Air intake grille2-5/32(55)1-3/8(35)1-3/8(35)2-5/32(55) Auto vane Grille Air intake hole Air intake holeAir outlet holeAir outlet hole11-27/32(301)11-27/32(301)14-27/32(377)14-27/32(377)25-19/32(650)Suspension bolt M10 or W3/8 9-1/16(230)7-5/32(182)1-7/8(48)Wiring entry Terminal block Ceiling surface 9-1/4(235)8-3/16(208)7-19/32(193)25/32(20)3-21/32(93)1-1/2~2-9/32(38~58)2-19/32(66)4-3/4(121)21/32(17)7-15/16(202)2-7/32(56)2-1/14(57)3-7/16(87)1-7/32(31)Ceiling holeSuspension bolt pitch19/32~1-15/32(15~37)19/32~1-15/32(15~37)22-11/16~24-13/32(576~620)16-17/32(420)22-7/16(570)13-3/16(335)7-27/32(199) 13-27/32(352) 13-3/16(335) Suspension bolt pitch Ceiling hole 25-19/32(650) Brand label V/M V/M V/M V/M 1/4 inch ( 6.35mm) flared connection 1/4 inch ( 6.35mm)flared connection 1/4 inch ( 9.52mm)flared connection 3/8 inch ( 12.7mm)flared connection 1/2 inch Refrigerantpipe (gas) Refrigerantpipe (liquid)Suspension boltlower edgeUnit : inch (mm) Specifications are subject to change without notice. © 2016 Mitsubishi Electric US, Inc. 1340 Satellite Boulevard. Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com FORM# SLZ-KA09NA - SUZ-KA09NA - 201604 DIMENSIONS: SUZ-KA09NA M-SERIES Specifications are subject to change without notice. © 2016 Mitsubishi Electric US, Inc. Job Name: System Reference:Date: SUBMITTAL DATA: SLZ-KA12NA & SUZ-KA12NA 12,000 BTU/H CEILING-CASSETTE HEAT-PUMP SYSTEMS Indoor Unit: SLZ-KA12NA Outdoor Unit: SUZ-KA12NA GENERAL FEATURES• Four-way 2'x2' ceiling-cassette indoor unit for ceiling recessed applications• Built-in drain mechanism for condensate removal; lifts to 19-11/16"• Wide air-flow pattern for better air distribution• Design features ventilation air intake knockout• Long-life air filter included with indoor unit• Indoor unit powered from outdoor unit using A-Control• Choice of fan speed: Low, Medium, High• Automatic restart following a power outage• Limited warranty: five years parts and seven years compressors ACCESSORIESIndoor Unit □Condensate Pump (BlueDiamond X87-711/721; 115/230V) □Condensate Pump (Sauermann SI30-115/230; 115/230V) □Grille (SLP-15AAUW; required - shipped with unit) Outdoor Unit □Three-pole Disconnect Switch (TAZ-MS303) □Air Outlet Guide (MAC-889SG) □Mounting Base (DSD-400P) □Mounting Pad (ULTRILITE1) □Wall Mounting Bracket (QSWB2000M-1) Controller Options □Wireless Controller (MHK1) □Wired Remote Controller (PAR-32MAA-J) □Wireless Interface for kumo cloud™ (PAC-WHS01WF-E) □Thermostat Interface (PAC-US444CN-1) □Hand-held Wireless Remote Controller (PAR-FL32MA; req.PAR-FA32MA-E) □Wireless Signal Receiver Module PAR-FA32MA (for PAR-FL32MA-E) SPECIFICATIONS Cooling1 Rated Capacity..................................11,100 Btu/hMinimum to Maximum Capacity Range .........3,400 - 13,300 Btu/hSEER .........................................15.4 Btu/h/WEER ..........................................12.0 Btu/h/WTotal Input...........................................920 W Heating at 47° F2 Rated Capacity..................................13,600 Btu/hMinimum to Maximum Capacity Range .........3,100 - 17,100 Btu/hHSPF ..........................................9.6 Btu/h/WCOP .................................................3.38Total Input..........................................1,180 W Heating at 17° F3 Rated Capacity...................................8,300 Btu/hRated Total Input .....................................930 WCOP .................................................2.62Maximum Capacity**...............................8,300 Btu/hMaximum Total Input .................................1,310 W ENERGY STAR®.....................................YesENERGY STAR products are third-party certified by an EPA-recognized Certification Body. Electrical RequirementsPower Supply ....................208 / 230V, 1-Phase, 60 HzRecommended Fuse/Breaker Size.......................15 A VoltageIndoor - Outdoor S1-S2 .......................AC 208 / 230VIndoor - Outdoor S2-S3 ...........................DC ±24V OPERATING CONDITIONS Indoor Intake Air Temp.Outdoor Intake Air Temp. Cooling4 Maximum 90° F (32° C) DB 73° F (23° C) WB 115° F (46° C) DB Minimum 67° F (19° C) DB 57° F (14° C) WB 14° F (-10° C) DB Heating Maximum 80° F (27° C) DB 67° F (19° C) WB 75° F (24° C) DB 65° F (18° C) WB Minimum 70° F (21° C) DB 60° F (16° C) WB -4° F (-20° C) DB -5° F (-21° C) WB5 4 Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. 5 System cuts out at -9º F (-27º C) to avoid thermistor error and automatically restarts at -4º F (-20º C). Indoor UnitMCA ...............................................1 AFan Motor Output ...................................20 WFan Motor (ECM) ...............................0.28 F.L.A.Airflow (Lo - Med - Hi)................280 - 320 - 390 Dry CFM250 - 290 - 350 Wet CFMAir Filter .........................Polypropylene HoneycombSound Pressure Level (Lo - Med - Hi) .........30 - 34 - 39 dB(A) DIMENSIONS UNIT INCHES / MM GRILLE INCHES / MM W 22-7/16 / 570 25-5/8 / 650 D 22-7/16 / 570 25-5/8 / 650 H 9-1/4 / 235 13/16 / 20 Weight (Unit/Grille) Lbs.............................................36 / 7 kg............................................16.5 / 3External Finish (Unit/Grille) ..........Galvanized-steel Sheets / Munsell 6.4Y 8.9 / 0.4Field Drainpipe Size O.D.......................1-1/4" / 32 mm Outdoor UnitCompressor .............................DC Inverter-drivenMCA ..............................................12 AMOCP.............................................15 AFan Motor (ECM) ...............................0.50 F.L.A.Sound Pressure Level Cooling ......................................49 dB(A) Heating ......................................51 dB(A) DIMENSIONS INCHES / MM W 31-1/2 / 800 D 11-1/4 / 285 H 21-5/8 / 550 Weight ....................................77 lbs. / 35 kgExternal Finish ......................Munsell No. 3Y 7.8 / 1.1Refrigerant Type...................................R410ARefrigerant Pipe Size O.D. Gas Side .................................3/8" / 9.52 mm Liquid Side................................1/4" / 6.35 mmMax. Refrigerant Pipe Length......................65' / 19 mMax. Refrigerant Pipe Height Difference .............40' / 12 mConnection Method ................................Flared 1 Cooling | Indoor: 80º F (27º C) DB / 67º F (19º C) WB* 1 Cooling | Outdoor: 95º F (35º C) DB / 75º F (24º C) WB* 2 Heating at 47º F | Indoor: 70º F (21º C) DB / 60º F (16º C) WB* 2 Heating at 47º F | Outdoor: 47º F (8º C) DB / 43º F (6º C) WB* 3 Heating at 17º F | Indoor: 70º F (21º C) DB / 60º F (16º C) WB* 3 Heating at 17º F | Outdoor: 17º F (-8º C) DB / 15º F (-9º C) WB* * Rating Conditions per AHRI Standard ** Maximum Capacity is at full speed and performance for INVERTER-driven System. Specifications are subject to change without notice. © 2016 Mitsubishi Electric US, Inc. DIMENSIONS: SLZ-KA12NA SLZ-KA15NA SLZ-KA12NA SLZ-KA09NA Models ( 6.35mm)flared connection Refrigerent pipe(liquid)Refrigerent pipe(gas) ( 9.52mm)flared connection 3/8 inch Detail drawing of fresh air intake Ceiling surface Cut out hole2-7/8(73.4) Burring hole3-1/8(2.8) 3-15/16(100)4-21/32(118)1(25)120120+5 0(27 )+3/16 01-1/1619/32~1-15/32(15~37)19/32~1-15/32(15~37)22-11/16~24-13/32(576~620) 22-7/16(570) 20-7/8(530) Grille Fresh airintake Drain pipeVP-25 connection(O.D.1-1/4(32)) Vane motor Drain hole Air intake grille2-5/32(55)1-3/8(35)1-3/8(35)2-5/32(55) Auto vane Grille Air intake hole Air intake holeAir outlet holeAir outlet hole11-27/32(301)11-27/32(301)14-27/32(377)14-27/32(377)25-19/32(650)Suspension bolt M10 or W3/8 9-1/16(230)7-5/32(182)1-7/8(48)Wiring entry Terminal block Ceiling surface 9-1/4(235)8-3/16(208)7-19/32(193)25/32(20)3-21/32(93)1-1/2~2-9/32(38~58)2-19/32(66)4-3/4(121)21/32(17)7-15/16(202)2-7/32(56)2-1/14(57)3-7/16(87)1-7/32(31)Ceiling holeSuspension bolt pitch19/32~1-15/32(15~37)19/32~1-15/32(15~37)22-11/16~24-13/32(576~620)16-17/32(420)22-7/16(570)13-3/16(335)7-27/32(199) 13-27/32(352) 13-3/16(335) Suspension bolt pitch Ceiling hole 25-19/32(650) Brand label V/M V/M V/M V/M 1/4 inch ( 6.35mm) flared connection 1/4 inch ( 6.35mm)flared connection 1/4 inch ( 9.52mm)flared connection 3/8 inch ( 12.7mm)flared connection 1/2 inch Refrigerantpipe (gas) Refrigerantpipe (liquid)Suspension boltlower edgeUnit : inch (mm) Specifications are subject to change without notice. © 2016 Mitsubishi Electric US, Inc. 1340 Satellite Boulevard. Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com FORM# SLZ-KA12NA - SUZ-KA12NA - 201604 DIMENSIONS: SUZ-KA12NA M-SERIES Specifications are subject to change without notice. © 2016 Mitsubishi Electric US, Inc. Job Name: System Reference:Date: SUBMITTAL DATA: MSZ-EF18NAB-U1 18,000 BTU/H WALL-MOUNTED INDOOR UNIT FOR MXZ-C MULTI-ZONE HEAT-PUMP SYSTEMS Indoor Unit: MSZ-EF18NAB-U1 Wireless Remote Controller ACCESSORIES: Indoor Unit □Condensate Pump (BlueDiamond X87-711/721; 115/230V) □Condensate Pump (Sauermann SI30-115/230; 115/230V) □Anti-allergy Enzyme Filter (MAC-2320FT-E) □Drain Pan Level Sensor (DPLS2) Controls □Wireless Controller (MHK1) □Wired Remote Controller PAR-32MAA-J (Requires MAC-333IF-E) □Wireless Interface for kumo cloud™ (PAC-WHS01WF-E) □Thermostat Interface (PAC-US444CN-1) SPECIFICATIONS: Rated Capacity* Cooling*1 Btu/h / W 17,200 Heating at 47º F*2 Btu/h / W 21,600 Rating Conditions per AHRI Standard:*1 Cooling | Indoor: 80º F(27º C)DB / 67º F(19º C)WB ; Outdoor: 95º F(35º C)DB / 75º F(24º C)WB*2 Heating at 47ºF | Indoor: 70º F (21º C)DB / 60º F (16º C)WB ; Outdoor: 47º F (8º C)DB / 43º F (6º C)WB For data on specific indoor units (all ducted, all non-ducted, and both ducted and non-ducted) combinations, see the MXZ Technical and Service Manual. Electrical Power Requirements 208 / 230V, 1-Phase, 60 Hz Minimum Circuit Ampacity (MCA)A 1 Blower Motor (ECM)F.L.A.0.67 Blower Motor Output W 30 Moisture Removal pt./h 4.4 Field Drainpipe Size O.D.In.(mm)5/8 (15) Airflow Rate (Lo - Med - Hi - Super Hi - Powerful) Cooling DRY CFM 205-240-279-328-388 WET 176-206-240-282-334 Heating DRY 226-258-318-392-466 Sound Pressure Level (Lo - Med - Hi - Super Hi - Powerful) Cooling dB(A)30-33-36-40-43 Heating 30-33-37-43-49 Unit Dimensions (H x W x D)In.(mm)11-3/4 x 34-13/16 x 7-11/16 (298 x 884 x 195) Package Dimensions (H x W x D)In.(mm)14-1/4 x 38-3/4 x 10-3/4 (362 x 984 x 273) Unit Weight Lbs.(kg)26 (11) Package Weight Lbs.(kg)29 (13) External Finish Munsell 3.7PB 2.0/0.1 Refrigerant Piping (Flared) Liquid (High Pressure)In.(mm)1/4 (6.35) Gas (Low Pressure)1/2 (12.7) Specifications are subject to change without notice. © 2016 Mitsubishi Electric US, Inc. 1340 Satellite Boulevard. Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com FORM# MSZ-EF18NAB-U1FOR MXZ-C MULTI-ZONE SYSTEMS - 201607 DIMENSIONS: MSZ-EF18NAB-U1 MSZ-EF18NAB-U1 6 Unit: inch OUTLINES AND DIMENSIONS4 MSZ-EF09NAW MSZ-EF12NAW MSZ-EF15NAW MSZ-EF18NAW MSZ-EF09NAB MSZ-EF12NAB MSZ-EF15NAB MSZ-EF18NAB MSZ-EF09NAS MSZ-EF12NAS MSZ-EF15NAS MSZ-EF18NAS MSZ-EF09/12NA MSZ-EF15/18NA OBH7366 Unit: inch OUTLINES AND DIMENSIONS4 MSZ-EF09NAW MSZ-EF12NAW MSZ-EF15NAW MSZ-EF18NAW MSZ-EF09NAB MSZ-EF12NAB MSZ-EF15NAB MSZ-EF18NAB MSZ-EF09NAS MSZ-EF12NAS MSZ-EF15NAS MSZ-EF18NAS MSZ-EF09/12NA MSZ-EF15/18NA OBH736 Job Name:Location:Date: Purchaser:Engineer: Submitted to:For Reference Approval Construction System Designation:Schedule No.: © 2011 MITSUBISHI ELECTRIC & ELECTRONICS, INC. 3400 Lawrenceville Suwanee RdSuwanee, GA 30024Tele: 678-376-2900 • Fax: 800-889-9904Toll Free: 800-433-4822 (#3)www.mehvac.comSpecifications are subject to change without notice. MRC1 CABLE• Connects MIFH1 Wireless Receiver to five- pin CN105 on indoor unit control board• Five-conductor wire with preterminated ends• Length: 6-1/2' (2 m) SUBMITTAL DATA: MHK1 REMOTE CONTROLLER KIT FOR M-SERIES AND P-SERIES FORM# MHK1 - 201108 RedLINK is a trademark of Honeywell, Inc. MRCH1 REMOTE CONTROLLER• For use with P-Series NHA4 systems, SEZ-4/SUZ one-to- one systems, SLZ/SUZ one-to-one systems, MXZ-B multi-zone systems, MSY/MSZ, and MFZ indoor units• Backlit, easy-to-read display• Supports both Fahrenheit and Celsius• User functions allow user to set: - On/Off - Operation modes cool,heat, drying, fan - Set temperature (separate dual set points for heat and cool) - Fan speed setting - Airflow direction• Day/Time display with a 12-hour clock• Filter sign display• Optimal start• Adjustable auto deadband• Space temperature offset adjustment• Display outside temperature and humidity (requires optional MOS1, sold separately)• Hold function• Temporary schedule override• Reset to factory default• Auto lock display• Timer Operation: - Daily Timer: On/Off times can be set up to 4 times per day in 15-minute increments. - Weekly Timer: On/Off times can be set up to 4 times per day of the week in 15-minute increments. Choice of 5-2 and 5-1-1 weekly schedules for heat, cool, auto (separate for each mode) - Auto-off Timer: Turns indoor unit Off at scheduled time up to 24 hours in advance• Room Temperature: Displays room temperature sensed either at the indoor unit or at the remote controller (default)• Set temperature range limits (dependent on the system connected): Cooling from 50° to 99°F Heating from 40° to 90°F Auto from 50° to 90°F with dual temperature setting MHK1 REMOTE CONTROLLER KIT INCLUDES: MIFH1 Wireless receiver MOS1Outside Air Sensor (Optional) MCCH1 Portable central controller Mr.Slim Outdoor Unit MRCH1 Remote controller r • Diagnostics: Displays and records error codes• No addressing required• Can be integrated with other RedLINK™ devices• Wiring: Connects using five-conductor cable from MIFH1 Wireless Receiver (cable included) to indoor unit; wireless RF from the MIFH1 Wireless Receiver to the MRCH1 Remote Controller• Dimensions: 3-9/16" H x 5-13/16" W x 1-1/2" D (147 x 38 x 91mm)• Uses two “AA” alkaline batteries (included) MIFH1 WIRELESS RECEIVER• Mounts next to or near indoor units to allow MRCH1 Remote Controller operation of P-Series NHA4 systems, SEZ-4/SUZ one-to-one systems, SLZ/SUZ one-to-one systems , MXZ-B multi-zone systems, MSY/MSZ, and MFZ indoor units• Dimensions: 6-7/16” H x 3-1/4” W x 1-5/16” D (164 x 82.5 x 34 mm) OPTIONAL ACCESSORIES □Portable Central Controller (MCCH1; for use with Wireless Remote Controller Kit MHK1)* □Outdoor Air Sensor (MOS1; for use with Wireless Remote Controller Kit MHK1)* *See Submittal for information on each option.