Product Data 24AHA4 Performance Series Air Conditioner with Puron Refrigerant 1-1/2 to 5 Nominal Tons Carrier air conditioners with Puron refrigerant provide a collection of features unmatched by any other family of equipment. The 24AHA4 has been designed utilizing Carrier’s Puron refrigerant. This environmentally sound refrigerant allows you to make a responsible decision in the protection of the earth’s ozone layer. NOTE: Ratings contained in this document are subject to change at any time. Always refer to the AHRI directory (www.ahridirectory.org) for the most up-to-date ratings information. INDUSTRY LEADING FEATURES / BENEFITS Energy Efficiency 14 SEER/11.7 - 12.2 EER (Based on tested combinations) Sound Levels as low as 66 dBA Design Features Small footprint WeatherArmor cabinet ⎯All steel cabinet construction ⎯Mesh coil guard Reliability, Quality and Toughness Scroll compressor Factory-supplied filter drier High pressure switch Line lengths up to 250’ (76.2 m) Low ambient operation (down to -20 F/-28.9 C with low ambient accessories) 2 MODEL NUMBER NOMENCLATURE 12 345678 N 91011 12 13 NN A A A/N N N A/N A/N A/N N N 24 AHA418 A00 3 0 Product Series Product Family Product Type Major Series SEER Cooling Capacity Variations Open Open Voltage Minor Series 24=AC A = AC H = Horizontal Discharge 4 = 14 SEER A=Standard 0=Not Defined 0=Not Defined 3=208/230-1 5=208/230-3 6=460/3 0, 1, 2... Use of the AHRI Certified TM Mark indicates a manufacturer’s participation in the program For verification of certification for individual products, go to www.ahridirectory.org. PHYSICAL DATA UNIT SIZE - SERIES 18-30 24-30 30-30 36-30, 50, 60 48-30, 50, 60 60-30, 50, 60 COMPRESSOR TYPE Scroll REFRIGERANT Puron® (R-410A) Charge lb (kg)6.40 (2.90)6.50 (2.95)8.60 (3.90)8.90 (4.04)9.00 (4.08)10.60 (4.81) COND FAN Propeller Type, Direct Drive Air Discharge Horizontal Air Qty (CFM)1285 1285 1900 2615 2615 2785 Motor HP 1/12 1/12 1/10 1/4 1/4 1/4 Motor RPM 800 800 800 800 800 800 COND COIL Face Area (Sq ft)7.3 7.3 12.1 12.1 12.1 14.1 Fins per In.20 20 20 20 20 20 Rows 2 2 2 2 2 2 Circuits 3 3 3 3 3 4 VALVE CONNECT. (In. ID) Vapor 5/8 3/4 3/4 7/8 7/8 7/8 Liquid 3/8 REFRIGERANT TUBES* (In. OD) Rated Vapor*5/8 3/4 3/4 7/8 7/8 1 1/8 Max Liquid Line 3/8 * Units are rated with 25 ft (7.6 m) of lineset length. See Vapor Line Sizing and Cooling Capacity Loss table when using other sizes and lengths of lineset. Note: See unit Installation Instruction for proper installation. See Liquid Line Sizing For Cooling Only Systems with Puron Refrigerant tables. 3 REFRIGERANT PIPING LENGTH LIMITATIONS Liquid Line Sizing and Maximum Total Equivalent Lengths for Cooling Only Systems with Puron Refrigerant: The maximum allowable length of a residential split system depends on the liquid line diameter and vertical separation between indoor and outdoor units. See the table below for liquid line sizing and maximum lengths : Maximum Total Equivalent Length Outdoor Unit BELOW Indoor Unit Size Liquid Line Connection Liquid Line Diam. w/ TXV AC with Puron Refrigerant Maximum Total Equivalent Length : Outdoor unit BELOW Indoor Vertical Separation ft (m) 0-5 (0-1.5) 6-10 (1.8-3.0) 11-20 (3.4-6.1) 21-30 (6.4-9.1) 31-40 (9.4-12.2) 41-50 (12.5-15.2) 51-60 (15.5-18.3) 61-70 (18.6-21.3) 71-80 (21.6-24.4) 018 AC with Puron 3/8 1/4 150 150 125 100 100 75 ------ 5/16 250*250*250*250*250*250*250*225*150 3/8 250*250*250*250*250*250*250*250*250* 024 AC with Puron 3/8 1/4 75 75 75 50 50 -------- 5/16 250*250*250*250*250*225*175 125 100 3/8 250*250*250*250*250*250*250*250*250* 030 AC with Puron 3/8 1/4 30 ---------------- 5/16 175 225*200 175 125 100 75 ---- 3/8 250*250*250*250*250*250*250*250*250* 036 AC with Puron 3/8 5/16 175 150 150 100 100 100 75 ---- 3//8 250*250*250*250*250*250*250*250*250* 048 AC with Puron 3/8 3/8 250*250*250*250*250*250*230 160 -- 060 AC with Puron 3/8 3/8 250*250*250*225*190 150 110 ---- * Maximum actual length not to exceed 200 ft (61 m) Total equivalent length accounts for losses due to elbows or fitting. See the Long Line Guideline for details. -- = outside acceptable range Maximum Total Equivalent Length Outdoor Unit ABOVE Indoor Unit Size Liquid Line Connection Liquid Line Diam. w/ TXV AC with Puron Refrigerant Maximum Total Equivalent Length : Outdoor unit ABOVE Indoor Vertical Separation ft (m) 25 (7.6) 26-50 (7.9-15.2) 51-75 (15.5-22.9) 76-100 (23.2-30.5) 101-125 (30.8-38.1) 126-150 (38.4-45.7) 151-175 (46.0-53.3) 176-200 (53.6-61.0) 018 AC with Puron 3/8 1/4 175 250*250*250*250*250*250*250* 5/16 250*250*250*250*250*250*250*250* 3/8 250*250*250*250*250*250*250*250* 024 AC with Puron 3/8 1/4 100 125 175 200 225*250*250*250* 5/16 250*250*250*250*250*250*250*250* 3/8 250*250*250*250*250*250*250*250* 030 AC with Puron 3/8 1/4 30 -------------- 5/16 250*250*250*250*250*250*250*250* 3/8 250*250*250*250*250*250*250*250* 036 AC with Puron 3/8 5/16 225*250*250*250*250*250*250*250* 3/8 250*250*250*250*250*250*250*250* 048 AC with Puron 3/8 3/8 250*250*250*250*250*250*250*250* 060 AC with Puron 3/8 3/8 250*250*250*250*250*250*250*250* * Maximum actual length not to exceed 200 ft (61 m) Total equivalent length accounts for losses due to elbows or fitting. See the Long Line Guideline for details. -- = outside acceptable range 4 REFRIGERANT CHARGE ADJUSTMENTS Liquid Line Size Puron Charge oz/ft (g/m) 3/8 0.60 (17.74) (Factory charge for lineset = 9 oz / 266.16 g) 5/16 0.40 (11.83) 1/4 0.27 (7.98) Units are factory charged for 15 ft (4.6 m) of 3/8” liquid line. The factory charge for 3/8” lineset 9 oz (266.16 g). When using other length or diameter liquid lines, charge adjustments are required per the chart above. Charging Formula: [(Lineset oz/ft x total length) – (factory charge for lineset)] = charge adjustment Example 1: System has 15 ft of line set using existing 1/4“ liquid line. What charge adjustment is required? Formula: (.27 oz/ft x 15ft) – (9 oz) = (4.95) oz. Net result is to remove 4.95 oz of refrigerant from the system Example 2: System has 45 ft of existing 5/16” liquid line. What is the charge adjustment? Formula: (.40 oz/ft. x 45ft) – (9 oz.) = 9 oz. Net result is to add 9 oz of refrigerant to the system LONG LINE APPLICATIONS An application is considered Long Line, when the refrigerant level in the system requires the use of accessories to maintain acceptable refrigerant management for systems reliability. See Accessory Usage Guideline table for required accessories. Defining a system as long line depends on the liquid line diameter, actual length of the tubing, and vertical separation between the indoor and outdoor units. For Air Conditioner systems, the chart below shows when an application is considered Long Line. AC WITH PURON REFRIGERANT LONG LINE DESCRIPTION ft (m) Beyond these lengths, long line accessories are required Liquid Line Size Units On Same Level Outdoor Below Indoor Outdoor Above Indoor 1/4 No accessories needed within allowed lengths No accessories needed within allowed lengths 175 (53.3) 5/16 120 (36.6)50 (15.2) vertical or 120 (36.6) total 120 (36.6) 3/8 80 (24.4)35 (10.7) vertical or 80 24.4) total 80 (24.4) Note: See Long Line Guideline for details VAPOR LINE SIZING AND COOLING CAPACITY LOSS LONG LINE APPLICATION: An application is considered ”Long line” when the total equivalent tubing length exceeds 80 ft. (24.38 m) or when there is more than 20 ft. (6.09 m) vertical separation between indoor and outdoor units. These applications require additional accessories and system modifications for reliable system operation. The maximum allowable total equivalent length is up to 250 ft. (76.2 m). The maximum vertical separation is 200 ft. (60.96 m) when outdoor unit is above indoor unit, and up to 80 ft. (24.38 m) when the outdoor unit is below the indoor unit. Refer to Accessory Usage Guideline below for required accessories. See Longline Application Guideline for required piping and system modifications. Also, refer to the table below for the vapor tube diameters based on the total length to minimize the cooling capacity loss. Vapor Line Sizing and Cooling Capacity Losses — Puron Refrigerant 1-Stage Air Conditioner Applications Unit Nominal Size (Btuh) Maximum Liquid Line Diameters (In. OD) Vapor Line Diameters (In. OD) Cooling Capacity Loss (%) Total Equivalent Line Length ft. (m) 26-50 (7.9-15.2) 51-80 (15.5-24.4) 81-100 (24.7-30.5) 101-125 (30.8-38.1) 126-150 (38.4-45.7) 151-175 (46.0-53.3) 176-200 (53.6-61.0) 201-225 (61.3-68.6) 226-250 (68.9-76.2) 018 1 Stage AC with Puron 3/8 1/2 1 2 3 5 6 7 8 9 11 5/8 0 1 1 1 2 2 2 3 3 3/4 0 0 0 0 1 1 1 1 1 024 1 Stage AC with Puron 3/8 5/8 0 1 2 2 3 3 4 5 5 3/4 0 0 1 1 1 1 1 2 2 7/8 0 0 0 0 0 1 1 1 1 030 1 Stage AC with Puron 3/8 5/8 1 2 3 3 4 5 6 7 8 3/4 0 0 1 1 1 2 2 2 3 7/8 0 0 0 0 1 1 1 1 1 036 1 Stage AC with Puron 3/8 5/8 1 2 4 5 6 8 9 10 12 3/4 0 1 1 2 2 3 3 4 4 7/8 0 0 0 1 1 1 1 2 2 048 1 Stage AC with Puron 3/8 3/4 0 1 2 3 4 5 5 6 7 7/8 0 0 1 1 2 2 2 3 3 1 1/8 0 0 0 0 0 0 0 1 1 060 1 Stage AC with Puron 3/8 3/4 1 2 4 5 6 7 9 10 11 7/8 0 1 2 2 3 4 4 5 5 1 1/8 0 0 0 1 1 1 1 1 1 Applications in this area may be long line and may have height restrictions. See the Residential Piping and Long Line Guideline. 5 ACCESSORIES KIT NUMBER KIT NAME Unit Size (Voltage/Series) 018 (30) 024 (30) 030 (30) 036 (30) 036 (50) 036 (60) 048 (30) 048 (50) 048 (60) 060 (30) 060 (50) 060 (60) KAACH1401AAA Crankcase Heater X X X X X KAACH1201AAA Crankcase Heater X X X X KAACH1501AAA Crankcase Heater X KAACH1901AAA Crankcase Heater X X KSAFT0101AAA Evaporator Freeze Stat X X X X X X X X X X X X KAATD0101TDR Time Delay Relay X X X X X X X X X X X X KAAWS0101AAA Winter Start Kit X X X X X X X X X X X X KSALA0801AAA MotorMaster 230v X X X X X X X X X KSALA0901AAA MotorMaster 460v X X X 53DS-900---087 Wind Baffle X X 53DS-900---071 Wind Baffle X X X X X X X 53DS-900---088 Wind Baffle X X X 53DS-900---075 Stacking Kit X X 53DS-900---076 Stacking Kit X X X X X X X X X X 53DS-900---077 Wall Mounting Kit X X 53DS-900---078 Wall Mounting Kit X X X X X X X X X X KAALP0401PUR Low Pressure Switch Kit X X X X X X X X X X X X KSASH2301COP Sound Blanket Kit X X X X X X KSASH2401COP Sound Blanket Kit X X X X X X KAALS0201LLS Solenoid Valve Kit X X X X X X X X X X X X KSAHS1501AAA Capacitor Relay Start Assist X X X X X X X = Accessory ACCESSORY THERMOSTATS PART NUMBER DESCRIPTION TPWEM01 Côr™ Thermostat TPPRH01A edge™ Programmable Relative Humidity Thermostat TPPAC01 edge™ Programmable Thermostat TPNRH01 edge™ NonProgrammable Relative Humidity Thermostat TPNAC01 edge™ NonProgrammable Thermostat TCWHS01 WiFi® Thermostat TCPAC01 Programmable Thermostat TCNAC01 NonProgrammable Thermostat TCSNAC01 NonProgrammable Standard Screen Thermostat THERMOSTAT ACCESSORIES TPEXP edge™ EXP® Card Programmable edge™ thermostats TSTATCCSEN01B Outdoor Air Temperature Sensor TPPxx, TPNxx TSTATXXCNV10 Thermostat Conversion Kit (4 to 5 wire) 10 pack All Carrier® branded thermostats TXMBP01 Medium Decorative Backplate TCNxx TXLBP01 Large Decorative Backplate TPPxx, TPNxx, TCPxx 6 ACCESSORY USAGE GUIDELINES Accessory REQUIRED FOR LOW-AMBIENT COOLING APPLICATIONS (Below 55 F / 12.8 C) REQUIRED FOR LONG LINE APPLICATIONS* (Over 80 ft. / 24.38 m) REQUIRED FOR SEA COAST APPLICATIONS (Within 2 miles / 3.22 km) Ball Bearing Fan Motor Standard Standard Standard Compressor Start Assist Capacitor and Relay Yes Yes No Crankcase Heater Yes Yes No Evaporator Freeze Thermostat Yes No No Liquid Line Solenoid Valve No See Long-Line Application Guideline No MotorMaster® Controller Yes No No * For tubing line sets between 80 and 200 ft. (24.38 and 60.96 m) and/or 20 ft. (6.09 m) vertical differential, refer to Residential Split-System Longline Application Guideline. Accessory Description and Usage (Listed Alphabetically) 1.Ball-Bearing Fan Motor A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication. Usage Guideline: Required on all units when using MotorMaster 2.Compressor Start Assist - Capacitor and Relay Start capacitor and relay gives a ”hard” boost to compressor motor at each start up. Usage Guideline: Required for reciprocating compressors in the following applications: Long line Low ambient cooling Hard shut off expansion valve on indoor coil Liquid line solenoid on indoor coil Required for single-phase scroll compressors in the following applications: Long line Low ambient cooling Suggested for all compressors in areas with a history of low voltage problems. 3.Crankcase Heater An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication on restart and minimizes the chance of liquid slugging. Usage Guideline: Required in low ambient cooling applications. Required in long line applications. Suggested in all commercial applications. 4.Evaporator Freeze Thermostat An SPST temperature-actuated switch that stops unit operation when evaporator reaches freeze-up conditions. Usage Guideline: Required when low ambient kit has been added. 5.Low Pressure Switch Kit Optional added compressor protection against loss of refrigerant. It cuts out the system at 50 PSI and allows operation again at 95 PSI. Used for commercial or “harsh” environment applications for extra protection. Not required for Low-Ambient Cooling application. 6.MotorMaster Low-Ambient Controller A fan-speed control device activated by a temperature sensor, designed to control condenser fan motor speed in response to the saturated condensing temperatures down to -20 F (-28.9 C), it maintains condensing temperature at 100 F +/- 10 F (37.8 C +/- 6 C). Usage Guideline: A MotorMaster Low-Ambient Controller must be used when the cooling operation is used at outdoor temperatures below 55 F (12.8 C). Suggested for all commercial applications. 7.Winter Start Kit The device is designed to alleviate nuisance opening of the low-pressure switch by bypassing it for the first 3 minutes of operation. A Winter Start control must be used where low evaporator temperatures, or nuisance tripping of low-pressure switch may be encountered. It is not required for low ambient cooling application unless a low-pressure switch KAALP0401PUR is added. 8.Time Delay Relay Optional accessory for systems that do not have an integral blower time delay. 7 ELECTRICAL DATA UNIT SIZE - voltage,series V/PH OPER VOLTS*COMPR FAN MCA MAX FUSE** or CKT BRK AMPSMAXMINLRARLAFLA 18-30 208/230/1 253 197 56.3 9.0 0.50 11.8 20 24-30 62.9 10.9 0.50 14.1 25 30-30 73.0 14.1 0.70 18.3 30 36-30 77.0 14.1 1.20 18.8 30 48-30 124.0 18.5 1.20 24.3 40 60-30 152.5 23.7 1.45 31.1 50 36-50 208/230/3 253 197 71.0 9.0 1.20 12.5 20 48-50 83.1 13.7 1.20 18.3 30 60-50 110.0 15.9 1.45 21.4 35 36-60 460/3 506 414 38.0 5.6 0.60 7.6 15 48-60 41.0 6.2 0.60 8.4 15 60-60 52.0 7.1 0.80 9.7 15 LEGEND: FLA - Full Load Amps HACR - Heating, Air Conditioning, Refrigeration LRA - Locked Rotor Amps NEC - National Electrical Code RLA - Rated Load Amps (compressor) * Permissible limits of the voltage range at which the unit will operate satisfactorily ** Time-Delay fuse. Complies with 2007 requirements of ASHRAE Standards 90.1 A-WEIGHTED SOUND POWER (dBA) Unit Size Standard Rating (dBA) Typical Octave Band Spectrum (dBA, without tone adjustment) 125 250 500 1000 2000 4000 8000 18 69 50.5 57.0 59.5 64.5 60.5 53.5 43.0 24 66 50.5 58.5 60.5 59.5 56.5 51.0 41.5 30 68 55.5 59.5 61.5 63.5 60.0 58.0 49.5 36 71 59.5 59.5 62.0 65.5 63.5 62.0 55.0 48 70 57.5 59.5 64.0 66.0 63.0 60.5 54.5 60 73 60.0 61.5 64.5 67.0 66.0 65.5 58.0 NOTE: Tested in accordance with AHRI Standard 270-08 (not listed in AHRI). A-WEIGHTED SOUND POWER (dBA) WITH ACCESSORY SOUND SHEILD Unit Size Standard Rating (dBA) Typical Octave Band Spectrum (dBA, without tone adjustment) 125 250 500 1000 2000 4000 8000 18 68 52.5 58.0 58.5 64.5 59.5 52.5 42.5 24 65 54.5 57.5 59.5 59.0 56.0 50.5 40.5 30 68 55.0 60.0 61.5 62.5 60.0 58.0 49.5 36 71 59.5 59.5 62.5 65.0 63.0 61.5 55.0 48 70 57.5 59.5 63.0 65.0 62.5 60.0 54.0 60 73 61.0 62.0 64.0 67.0 65.5 65.5 57.5 NOTES: Tested in accordance with AHRI Standard 270-08 (not listed in AHRI). CHARGING SUB-COOLING (TXV-TYPE EXPANSION DEVICE) UNIT SIZE-SERIES REQUIRED SUBCOOLING °F (°C) 18 12 (6.7) 24 12 (6.7) 30 12 (6.7) 36 8 (4.4) 48 12 (6.7) 60 10 (5.6) 8DIMENSIONS - ENGLISH 9DIMENSIONS - SI 10 TESTED AHRI COMBINATION RATINGS* NOTE: Ratings contained in this document are subject to change at any time. For AHRI ratings certificates, please refer to the AHRI directory www.ahridirectory.org Additional ratings and system combinations can be accessed via the Carrier database at: www.MyCarrierRatings.com For performance data at specific application &/or design conditions with various indoor unit combinations, the equipment performance calculator can be accessed at : http://rpmob.wrightsoft.com/ Outdoor Model Number Indoor Coil Model Number Furnace Model Number Capacity EER SEER 24AHA418A30 CNPV*3014AL*+TDR 18,000 12.2 14 24AHA424A30 CNPV*3117AL*+TDR 24,000 12.2 14 24AHA430A30 CNPV*3117AL*+TDR 29,600 12.2 14 24AHA436A30 CNPV*3717AL*+TDR 35,400 12.2 14 24AHA436A50 CNPV*3717AL*+TDR 35,400 12.2 14 24AHA436A60 CNPV*3717AL*+TDR 35,400 12.2 14 24AHA448A30 CNPV*6024AL*+TDR 45,000 11.7 14 24AHA448A50 CNPV*6024AL*+TDR 45,000 11.7 14 24AHA448A60 CNPV*6024AL*+TDR 45,000 11.7 14 24AHA460A30 CNPV*6124AL*+TDR 57,000 11.7 14 24AHA460A50 CNPV*6124AL*+TDR 57,000 11.7 14 24AHA460A60 CNPV*6124AL*+TDR 57,000 11.7 14 EER — Energy Efficiency Ratio SEER— Seasonal Energy Efficiency Ratio TXV — Thermostatic Expansion Valve NOTES: 1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included. 2. Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for central air conditioners. Ratings for other combinations are determined under DOE computer simulation procedures. 3. Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature. 4. Do not apply with capillary tube coils as performance and reliability are significantly affected. 11DETAILED COOLING CAPACITIES EVAPORATOR AIR CONDENSER ENTERING AIR TEMPERATURES °F (°C) 75 (23.9)85 (29.4)95 (35)105 (40.6)115 (46.1)125 (51.7) CFM EWB °F (°C) Capacity MBtuh Total Sys KW** Capacity MBtuh Total Sys KW** Capacity MBtuh Total Sys KW** Capacity MBtuh Total Sys KW** Capacity MBtuh Total Sys KW** Capacity MBtuh Total Sys KW**Total Sens‡Total Sens‡Total Sens‡Total Sens‡Total Sens‡Total Sens‡ 24AHA418A30 Outdoor Section With CNPV*3014AL* Indoor Section 525 72 (22.2)21.49 10.92 1.18 20.55 10.57 1.31 19.56 10.21 1.45 18.50 9.83 1.61 17.36 9.43 1.79 16.12 9.00 2.00 67 (19.4)19.43 13.31 1.18 18.58 12.96 1.31 17.67 12.60 1.45 16.71 12.22 1.61 15.68 11.82 1.79 14.57 11.39 2.00 63 (17.2)17.96 12.78 1.18 17.15 12.43 1.31 16.31 12.06 1.45 15.43 11.69 1.61 14.48 11.29 1.79 13.46 10.86 2.00 62 (16.7)17.68 15.68 1.18 16.91 15.33 1.31 16.11 14.96 1.45 15.28 14.56 1.61 14.48 14.48 1.79 13.65 13.65 2.00 57 (13.9)17.17 17.17 1.18 16.55 16.55 1.31 15.91 15.91 1.45 15.21 15.21 1.61 14.46 14.46 1.79 13.63 13.63 2.00 600 72 (22.2)21.93 11.50 1.21 20.94 11.14 1.34 19.90 10.77 1.48 18.79 10.38 1.64 17.61 9.97 1.82 16.32 9.53 2.03 67 (19.4)19.84 14.22 1.21 18.94 13.87 1.34 18.00 13.50 1.48 17.00 13.11 1.63 15.93 12.70 1.82 14.78 12.26 2.03 63 (17.2)18.34 13.63 1.21 17.51 13.27 1.33 16.63 12.90 1.47 15.70 12.51 1.63 14.72 12.10 1.82 13.65 11.66 2.03 62 (16.7)18.14 16.91 1.21 17.36 16.53 1.33 16.61 16.61 1.47 15.86 15.86 1.63 15.05 15.05 1.82 14.15 14.15 2.03 57 (13.9)17.95 17.95 1.21 17.29 17.29 1.33 16.59 16.59 1.47 15.84 15.84 1.63 15.02 15.02 1.82 14.13 14.13 2.03 675 72 (22.2)22.25 12.05 1.24 21.22 11.69 1.36 20.15 11.31 1.50 19.00 10.91 1.66 17.78 10.50 1.85 16.46 10.05 2.06 67 (19.4)20.15 15.11 1.24 19.22 14.74 1.36 18.25 14.37 1.50 17.22 13.97 1.66 16.12 13.55 1.85 14.94 13.09 2.06 63 (17.2)18.64 14.45 1.24 17.77 14.08 1.36 16.86 13.70 1.50 15.91 13.30 1.66 14.90 12.88 1.84 13.81 12.42 2.05 62 (16.7)18.63 18.63 1.24 17.92 17.92 1.36 17.18 17.18 1.50 16.38 16.38 1.66 15.51 15.51 1.84 14.56 14.56 2.06 57 (13.9)18.60 18.60 1.24 17.89 17.89 1.36 17.15 17.15 1.50 16.36 16.36 1.66 15.49 15.49 1.84 14.55 14.55 2.06 EVAPORATOR AIR CONDENSER ENTERING AIR TEMPERATURES °F (°C) 75 (23.9)85 (29.4)95 (35)105 (40.6)115 (46.1)125 (51.7) CFM EWB °F (°C) Capacity MBtuh Total Sys KW** Capacity MBtuh Total Sys KW** Capacity MBtuh Total Sys KW** Capacity MBtuh Total Sys KW** Capacity MBtuh Total Sys KW** Capacity MBtuh Total Sys KW**Total Sens‡Total Sens‡Total Sens‡Total Sens‡Total Sens‡Total Sens‡ 24AHA424A30 Outdoor Section With CNPV*3117AL* Indoor Section 700 72 (22.2)28.62 14.23 1.58 27.33 13.77 1.75 25.95 13.30 1.94 24.48 12.80 2.15 22.90 12.26 2.40 21.21 11.70 2.67 67 (19.4)26.06 17.53 1.57 24.88 17.08 1.74 23.63 16.60 1.93 22.30 16.09 2.14 20.87 15.56 2.39 19.33 14.99 2.67 63 (17.2)24.20 16.87 1.57 23.11 16.41 1.74 21.96 15.94 1.92 20.73 15.44 2.14 19.41 14.91 2.38 17.99 14.34 2.66 62 (16.7)23.80 20.79 1.57 22.74 20.32 1.73 21.65 19.83 1.92 20.58 20.58 2.14 19.51 19.51 2.38 18.33 18.33 2.66 57 (13.9)23.29 23.29 1.57 22.44 22.44 1.73 21.53 21.53 1.92 20.55 20.55 2.14 19.48 19.48 2.38 18.31 18.31 2.66 800 72 (22.2)29.11 14.99 1.62 27.76 14.53 1.79 26.33 14.04 1.98 24.80 13.53 2.19 23.16 12.99 2.43 21.41 12.42 2.71 67 (19.4)26.53 18.75 1.61 25.30 18.29 1.78 24.00 17.80 1.97 22.61 17.28 2.18 21.13 16.74 2.43 19.54 16.16 2.70 63 (17.2)24.68 18.01 1.61 23.53 17.54 1.77 22.33 17.06 1.96 21.05 16.55 2.18 19.67 16.00 2.42 18.21 15.42 2.70 62 (16.7)24.39 22.42 1.61 23.40 23.40 1.77 22.42 22.42 1.96 21.36 21.36 2.18 20.20 20.20 2.42 18.94 18.94 2.70 57 (13.9)24.28 24.28 1.61 23.36 23.36 1.77 22.39 22.39 1.96 21.32 21.32 2.18 20.17 20.17 2.42 18.91 18.91 2.70 900 72 (22.2)29.46 15.72 1.66 28.07 15.25 1.83 26.59 14.76 2.01 25.01 14.24 2.23 23.33 13.69 2.47 21.53 13.11 2.75 67 (19.4)26.88 19.93 1.65 25.61 19.46 1.82 24.27 18.96 2.01 22.84 18.43 2.22 21.32 17.87 2.46 19.70 17.27 2.74 63 (17.2)25.04 19.11 1.65 23.85 18.63 1.81 22.60 18.14 2.00 21.28 17.61 2.21 19.87 17.05 2.46 18.38 16.43 2.74 62 (16.7)25.15 25.15 1.65 24.16 24.16 1.81 23.11 23.11 2.00 21.98 21.98 2.22 20.75 20.75 2.46 19.42 19.42 2.74 57 (13.9)25.11 25.11 1.65 24.13 24.13 1.81 23.08 23.08 2.00 21.95 21.95 2.22 20.73 20.73 2.46 19.39 19.39 2.74 See notes on pg. 13 12DETAILED COOLING CAPACITIES(CONT.) Evaporator Air CONDENSER ENTERING AIR TEMPERATURES F (C) 75 (23.9)85 (29.4)95 (35)105 (40.6)115 (46.1)125 (51.7) CFM EWB F (C) Capacity MBtuh† Total System KW** Capacity MBtuh† Total System KW** Capacity MBtuh† Total System KW** Capacity MBtuh† Total System KW** Capacity MBtuh† Total System KW** Capacity MBtuh† Total System KW** Total Sens‡ Total System KW** Total Sens‡ Total System KW** Total Sens‡ Total System KW** Total Sens‡ Total System KW** Total Sens‡ Total System KW** Total Sens‡ Total System KW** 24AHA430A30 Outdoor Section With CNPV*3117AL* Indoor Section 875 72 (22.2)35.20 16.84 1.95 33.62 16.29 2.18 31.97 15.73 2.43 30.18 15.13 2.70 28.24 14.48 3.02 26.13 13.79 3.38 67 (19.4)31.99 20.62 1.92 30.56 20.08 2.15 29.06 19.51 2.40 27.44 18.91 2.68 25.67 18.26 3.00 23.75 17.57 3.36 63 (17.2)29.66 19.84 1.90 28.34 19.30 2.13 26.95 18.74 2.37 25.45 18.13 2.66 23.80 17.48 2.98 22.02 16.78 3.35 62 (16.7)29.18 24.36 1.90 27.92 23.82 2.12 26.58 23.24 2.37 25.18 24.97 2.65 23.81 23.81 2.98 22.34 22.34 3.35 57 (13.9)28.38 28.38 1.89 27.37 27.37 2.12 26.28 26.28 2.37 25.09 25.09 2.65 23.77 23.77 2.98 22.31 22.31 3.35 1000 72 (22.2)35.90 17.73 1.98 34.26 17.17 2.21 32.52 16.59 2.46 30.66 15.98 2.74 28.65 15.32 3.05 26.46 14.62 3.41 67 (19.4)32.65 22.03 1.95 31.17 21.48 2.18 29.60 20.90 2.43 27.91 20.28 2.71 26.08 19.62 3.03 24.10 18.91 3.39 63 (17.2)30.30 21.15 1.93 28.93 20.60 2.16 27.48 20.02 2.40 25.91 19.41 2.69 24.21 18.74 3.01 22.36 18.02 3.37 62 (16.7)29.94 26.26 1.93 28.66 25.66 2.15 27.43 27.43 2.41 26.15 26.15 2.69 24.73 24.73 3.01 23.17 23.17 3.38 57 (13.9)29.65 29.65 1.93 28.56 28.56 2.15 27.39 27.39 2.40 26.11 26.11 2.69 24.70 24.70 3.01 23.14 23.14 3.38 1125 72 (22.2)36.44 18.57 2.01 34.73 18.00 2.24 32.94 17.41 2.49 31.02 16.79 2.77 28.94 16.12 3.08 26.71 15.41 3.43 67 (19.4)33.18 23.38 1.98 31.64 22.82 2.21 30.01 22.23 2.46 28.28 21.60 2.74 26.40 20.92 3.05 24.38 20.18 3.41 63 (17.2)30.81 22.41 1.96 29.38 21.85 2.19 27.89 21.26 2.43 26.28 20.63 2.72 24.53 19.94 3.04 22.65 19.20 3.40 62 (16.7)30.76 30.76 1.96 29.59 29.59 2.19 28.34 28.34 2.44 26.99 26.99 2.72 25.49 25.49 3.05 23.84 23.84 3.41 57 (13.9)30.72 30.72 1.96 29.55 29.55 2.19 28.31 28.31 2.44 26.95 26.95 2.72 25.45 25.45 3.04 23.81 23.81 3.41 EVAPORATOR AIR CONDENSER ENTERING AIR TEMPERATURES °F (°C) 75 (23.9)85 (29.4)95 (35)105 (40.6)115 (46.1)125 (51.7) CFM EWB °F (°C) Capacity MBtuh Total Sys KW** Capacity MBtuh Total Sys KW** Capacity MBtuh Total Sys KW** Capacity MBtuh Total Sys KW** Capacity MBtuh Total Sys KW** Capacity MBtuh Total Sys KW**Total Sens‡Total Sens‡Total Sens‡Total Sens‡Total Sens‡Total Sens‡ 24AHA436A30 Outdoor Section With CNPV*3717AL* Indoor Section 1050 72 (22.2)42.58 22.26 2.36 40.51 21.51 2.60 38.30 20.71 2.87 35.94 19.87 3.16 33.37 18.97 3.50 30.62 18.01 3.88 67 (19.4)38.73 27.46 2.34 36.87 26.71 2.58 34.88 25.92 2.84 32.74 25.08 3.14 30.43 24.18 3.48 27.97 23.23 3.86 63 (17.2)35.96 26.41 2.32 34.24 25.67 2.56 32.40 24.88 2.82 30.43 24.04 3.12 28.31 23.15 3.46 26.03 22.20 3.85 62 (16.7)35.38 32.60 2.32 33.73 31.84 2.56 32.01 31.81 2.82 30.38 30.38 3.12 28.63 28.63 3.46 26.73 26.73 3.85 57 (13.9)34.71 34.71 2.31 33.37 33.37 2.55 31.92 31.92 2.82 30.34 30.34 3.12 28.59 28.59 3.46 26.70 26.70 3.85 1200 72 (22.2)43.29 23.46 2.42 41.13 22.69 2.66 38.84 21.88 2.93 36.37 21.02 3.22 33.71 20.10 3.56 30.85 19.13 3.94 67 (19.4)39.43 29.38 2.40 37.47 28.61 2.64 35.40 27.80 2.90 33.18 26.94 3.20 30.79 26.02 3.53 28.26 25.05 3.92 63 (17.2)36.64 28.20 2.38 34.83 27.43 2.62 32.92 26.62 2.88 30.87 25.77 3.18 28.67 24.85 3.52 26.33 23.88 3.91 62 (16.7)36.27 36.05 2.38 34.77 34.77 2.62 33.20 33.20 2.89 31.50 31.50 3.19 29.61 29.61 3.53 27.57 27.57 3.92 57 (13.9)36.17 36.17 2.38 34.71 34.71 2.62 33.15 33.15 2.89 31.45 31.45 3.19 29.57 29.57 3.53 27.54 27.54 3.91 1350 72 (22.2)43.81 24.60 2.48 41.58 23.82 2.72 39.20 23.00 2.99 36.66 22.13 3.28 33.92 21.20 3.62 31.04 20.23 4.00 67 (19.4)39.93 31.22 2.46 37.92 30.44 2.70 35.78 29.61 2.96 33.50 28.73 3.26 31.06 27.78 3.59 28.49 26.76 3.98 63 (17.2)37.14 29.91 2.44 35.28 29.13 2.68 33.30 28.30 2.94 31.20 27.42 3.24 28.94 26.47 3.58 26.58 25.43 3.97 62 (16.7)37.43 37.43 2.44 35.87 35.87 2.68 34.21 34.21 2.95 32.39 32.39 3.25 30.39 30.39 3.59 28.23 28.23 3.98 57 (13.9)37.38 37.38 2.44 35.83 35.83 2.68 34.16 34.16 2.95 32.35 32.35 3.25 30.36 30.36 3.59 28.20 28.20 3.98 See notes on pg. 13 13DETAILED COOLING CAPACITIES (CONT.) EVAPORATOR AIR CONDENSER ENTERING AIR TEMPERATURES °F (°C) 75 (23.9)85 (29.4)95 (35)105 (40.6)115 (46.1)125 (51.7) CFM EWB °F (°C) Capacity MBtuh Total Sys KW** Capacity MBtuh Total Sys KW** Capacity MBtuh Total Sys KW** Capacity MBtuh Total Sys KW** Capacity MBtuh Total Sys KW** Capacity MBtuh Total Sys KW**Total Sens‡Total Sens‡Total Sens‡Total Sens‡Total Sens‡Total Sens‡ 24AHA448A30 Outdoor Section With CNPV*6024AL* Indoor Section 1400 72 (22.2)54.32 28.47 3.22 51.89 27.57 3.53 49.29 26.62 3.88 46.43 25.59 4.29 43.30 24.47 4.76 39.89 23.27 5.30 67 (19.4)49.54 35.14 3.19 47.35 34.25 3.49 45.00 33.30 3.85 42.43 32.28 4.25 39.60 31.16 4.72 36.51 29.95 5.26 63 (17.2)46.06 33.82 3.16 44.05 32.94 3.47 41.89 32.00 3.82 39.52 30.98 4.22 36.90 29.87 4.69 34.04 28.66 5.23 62 (16.7)45.44 41.73 3.15 43.53 40.82 3.46 41.48 39.82 3.81 39.37 39.37 4.22 37.22 37.22 4.70 34.80 34.80 5.24 57 (13.9)44.54 44.54 3.15 42.97 42.97 3.46 41.24 41.24 3.81 39.32 39.32 4.22 37.17 37.17 4.70 34.76 34.76 5.24 1600 72 (22.2)55.17 29.90 3.30 52.64 28.99 3.61 49.92 28.01 3.96 46.96 26.96 4.37 43.72 25.83 4.84 40.19 24.61 5.38 67 (19.4)50.36 37.46 3.27 48.09 36.55 3.57 45.64 35.59 3.93 42.97 34.53 4.34 40.05 33.39 4.81 36.86 32.13 5.34 63 (17.2)46.86 35.98 3.24 44.77 35.09 3.55 42.51 34.12 3.90 40.05 33.08 4.31 37.35 31.93 4.77 34.40 30.67 5.31 62 (16.7)46.51 44.79 3.24 44.64 44.64 3.55 42.79 42.79 3.90 40.73 40.73 4.31 38.42 38.42 4.79 35.83 35.83 5.33 57 (13.9)46.30 46.30 3.24 44.60 44.60 3.55 42.73 42.73 3.90 40.67 40.67 4.31 38.37 38.37 4.79 35.79 35.79 5.33 1800 72 (22.2)55.79 31.25 3.38 53.16 30.32 3.69 50.36 29.34 4.04 47.31 28.27 4.45 43.97 27.12 4.92 40.37 25.89 5.46 67 (19.4)50.98 39.68 3.35 48.62 38.75 3.65 46.10 37.76 4.01 43.37 36.69 4.42 40.37 35.50 4.89 37.14 34.18 5.42 63 (17.2)47.47 38.04 3.32 45.30 37.12 3.63 42.98 36.13 3.98 40.45 35.06 4.39 37.69 33.87 4.86 34.70 32.54 5.39 62 (16.7)47.80 47.80 3.32 45.99 45.99 3.63 44.00 44.00 3.99 41.81 41.81 4.40 39.36 39.36 4.88 36.64 36.64 5.42 57 (13.9)47.74 47.74 3.32 45.93 45.93 3.63 43.95 43.95 3.99 41.76 41.76 4.40 39.32 39.32 4.87 36.60 36.60 5.41 EVAPORATOR AIR CONDENSER ENTERING AIR TEMPERATURES °F (°C) 75 (23.9)85 (29.4)95 (35)105 (40.6)115 (46.1)125 (51.7) CFM EWB °F (°C) Capacity MBtuh Total Sys KW** Capacity MBtuh Total Sys KW** Capacity MBtuh Total Sys KW** Capacity MBtuh Total Sys KW** Capacity MBtuh Total Sys KW** Capacity MBtuh Total Sys KW**Total Sens‡Total Sens‡Total Sens‡Total Sens‡Total Sens‡Total Sens‡ 24AHA460A30 Outdoor Section With CNPV*6124AL* Indoor Section 1750 72 (22.2)68.86 34.68 4.09 65.73 33.57 4.48 62.37 32.40 4.93 58.68 31.12 5.45 54.65 29.75 6.04 50.21 28.26 6.71 67 (19.4)62.81 42.85 4.03 60.01 41.76 4.42 57.00 40.60 4.87 53.69 39.34 5.39 50.05 37.96 5.98 46.03 36.46 6.65 63 (17.2)58.41 41.24 3.99 55.85 40.17 4.38 53.11 39.03 4.82 50.06 37.78 5.34 46.70 36.41 5.93 42.98 34.90 6.59 62 (16.7)57.61 50.93 3.98 55.17 49.82 4.37 52.58 48.59 4.82 49.93 49.93 5.34 47.15 47.15 5.94 44.00 44.00 6.61 57 (13.9)56.53 56.53 3.97 54.53 54.53 4.37 52.32 52.32 4.82 49.86 49.86 5.34 47.09 47.09 5.94 43.94 43.94 6.61 2000 72 (22.2)69.94 36.44 4.19 66.66 35.31 4.58 63.14 34.10 5.04 59.32 32.81 5.56 55.14 31.41 6.15 50.56 29.90 6.81 67 (19.4)63.84 45.70 4.14 60.93 44.59 4.53 57.78 43.40 4.98 54.34 42.10 5.49 50.59 40.69 6.08 46.45 39.14 6.75 63 (17.2)59.43 43.90 4.09 56.76 42.80 4.48 53.87 41.62 4.93 50.72 40.34 5.44 47.25 38.93 6.03 43.42 37.37 6.70 62 (16.7)58.98 54.67 4.09 56.66 56.66 4.48 54.28 54.28 4.94 51.61 51.61 5.46 48.63 48.63 6.06 45.27 45.27 6.73 57 (13.9)58.76 58.76 4.09 56.58 56.58 4.48 54.20 54.20 4.93 51.55 51.55 5.46 48.57 48.57 6.05 45.22 45.22 6.73 2250 72 (22.2)70.70 38.10 4.29 67.30 36.94 4.68 63.68 35.72 5.14 59.73 34.41 5.66 55.44 32.99 6.25 50.77 31.46 6.91 67 (19.4)64.61 48.42 4.24 61.59 47.28 4.63 58.35 46.06 5.08 54.82 44.74 5.59 50.98 43.27 6.18 46.79 41.64 6.85 63 (17.2)60.18 46.42 4.19 57.41 45.29 4.58 54.45 44.09 5.03 51.21 42.77 5.55 47.66 41.31 6.13 43.79 39.65 6.80 62 (16.7)60.66 60.66 4.20 58.34 58.34 4.59 55.79 55.79 5.05 52.96 52.96 5.57 49.81 49.81 6.17 46.25 46.25 6.84 57 (13.9)60.58 60.58 4.20 58.27 58.27 4.59 55.72 55.72 5.05 52.90 52.90 5.57 49.75 49.75 6.17 46.20 46.20 6.84 Total and sensible capacities are net capacities. Blower motor heat has been subtracted. Sensible capacities shown are based on 80 F (27 C) entering air at the indoor coil. For sensible capacities at other than 80 F (27 C), deduct 835 Btuh (245 kW) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80 F (27 C), or add 835 Btuh (245 kW) per 1000 CFM (480 L/S) of indoor coil air per degree above 80 F (27 C). ** System kw is total of indoor and outdoor unit kilowatts. EWB — Entering Wet Bulb NOTES: 1. Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per AHRI standard 210/240-2008. If additional tubing length and/or indoor unit is located above outdoor unit, a slight variation in capacity may occur. 2. When the required data falls between the published data, interpolation may be performed. Extrapolation is not an acceptable practice. 14 CONDENSOR ONLY RATINGS SST °F (°C) CONDENSER ENTERING AIR TEMPERATURES °F (°C) 55 (12.78)65 (18.33)75 (23.89)85 (29.44)95 (35.0)105 (40.56)115 (46.11)125 (51.67) 24AHA418A30 30 (-1.11) TCG 16.60 15.60 14.70 13.80 12.90 12.00 11.10 10.10 SDT 68.50 78.00 87.50 97.00 106.50 116.00 125.40 134.70 KW 0.76 0.87 0.99 1.11 1.25 1.40 1.59 1.80 35 (1.67) TCG 18.30 17.20 16.30 15.30 14.30 13.30 12.30 11.20 SDT 69.70 79.20 88.70 98.20 107.60 117.00 126.30 135.50 KW 0.76 0.87 0.99 1.11 1.25 1.41 1.59 1.80 40 (4.44) TCG 20.00 19.00 17.90 16.90 15.80 14.70 13.60 12.40 SDT 71.10 80.50 89.90 99.40 108.70 118.00 127.20 136.30 KW 0.77 0.88 0.99 1.11 1.25 1.41 1.59 1.80 45 (7.22) TCG 22.00 20.80 19.70 18.50 17.40 16.20 14.90 13.60 SDT 72.50 81.90 91.30 100.60 109.80 119.00 128.20 137.20 KW 0.77 0.88 0.99 1.12 1.26 1.41 1.59 1.80 50 (10.0) TCG 24.00 22.80 21.60 20.40 19.10 17.80 16.40 15.00 SDT 74.00 83.40 92.60 101.90 111.00 120.10 129.20 138.20 KW 0.77 0.88 0.99 1.12 1.26 1.41 1.59 1.80 55 (12.78) TCG 26.30 25.00 23.60 22.30 20.90 19.50 18.00 16.40 SDT 75.60 84.80 94.10 103.20 112.30 121.30 130.30 139.20 KW 0.78 0.88 1.00 1.12 1.26 1.42 1.60 1.80 24AHA424A30 30 (-1.11) TCG 21.40 20.20 19.00 17.80 16.60 15.40 14.20 12.90 SDT 71.90 81.30 90.70 100.00 109.30 118.50 127.70 136.80 KW 1.01 1.15 1.30 1.46 1.64 1.85 2.09 2.36 35 (1.67) TCG 23.50 22.20 20.90 19.60 18.30 17.00 15.60 14.20 SDT 73.50 82.80 92.10 101.30 110.50 119.60 128.70 137.70 KW 1.02 1.16 1.30 1.47 1.65 1.86 2.09 2.37 40 (4.44) TCG 25.70 24.40 23.00 21.60 20.20 18.70 17.20 15.60 SDT 75.10 84.30 93.50 102.60 111.80 120.80 129.80 138.80 KW 1.02 1.16 1.31 1.47 1.66 1.86 2.10 2.38 45 (7.22) TCG 28.20 26.70 25.20 23.70 22.10 20.50 18.90 17.10 SDT 76.70 85.90 95.00 104.10 113.10 122.10 131.00 139.80 KW 1.03 1.17 1.32 1.48 1.66 1.87 2.11 2.39 50 (10.0) TCG 30.80 29.20 27.50 25.90 24.20 22.40 20.60 18.70 SDT 78.50 87.50 96.60 105.60 114.60 123.40 132.20 140.90 KW 1.04 1.18 1.32 1.49 1.67 1.88 2.12 2.39 55 (12.78) TCG 33.60 31.80 30.10 28.30 26.40 24.50 22.40 20.30 SDT 80.30 89.30 98.30 107.20 116.10 124.90 133.50 142.00 KW 1.05 1.18 1.33 1.50 1.68 1.89 2.13 2.40 24AHA430A30 30 (-1.11) TCG 27.20 25.80 24.40 22.90 21.40 19.70 17.90 16.00 SDT 69.90 79.20 88.60 98.00 107.30 116.60 125.80 134.80 KW 1.22 1.39 1.57 1.77 2.00 2.27 2.58 2.94 35 (1.67) TCG 30.10 28.50 27.00 25.40 23.70 21.90 20.00 17.90 SDT 71.20 80.60 89.90 99.20 108.50 117.70 126.80 135.80 KW 1.22 1.40 1.58 1.78 2.01 2.28 2.58 2.94 40 (4.44) TCG 33.10 31.40 29.70 28.00 26.20 24.30 22.20 20.00 SDT 72.70 82.00 91.20 100.50 109.70 118.90 127.90 136.90 KW 1.23 1.41 1.59 1.80 2.03 2.29 2.59 2.94 45 (7.22) TCG 36.50 34.50 32.70 30.80 28.80 26.80 24.50 22.10 SDT 74.30 83.50 92.70 101.90 111.00 120.10 129.10 137.90 KW 1.25 1.43 1.61 1.82 2.05 2.31 2.60 2.95 50 (10.0) TCG 40.00 37.90 35.80 33.80 31.60 29.40 27.00 24.40 SDT 76.00 85.10 94.20 103.40 112.40 121.40 130.30 139.00 KW 1.27 1.45 1.64 1.84 2.07 2.33 2.62 2.95 55 (12.78) TCG 43.80 41.40 39.20 36.90 34.60 32.10 29.50 26.70 SDT 77.90 86.90 95.90 104.90 113.90 122.80 131.50 140.20 KW 1.29 1.47 1.66 1.87 2.09 2.35 2.64 2.97 See notes on page 15 15 CONDENSER ONLY RATINGS CONTINUED SST °F (°C) CONDENSER ENTERING AIR TEMPERATURES °F (°C) 55 (12.78)65 (18.33)75 (23.89)85 (29.44)95 (35.0)105 (40.56)115 (46.11)125 (51.67) 24AHA436A30 30 (-1.11) TCG 31.40 29.80 28.20 26.40 24.60 22.70 20.60 18.50 SDT 68.70 78.10 87.50 96.80 106.20 115.50 124.70 134.00 KW 1.48 1.69 1.91 2.14 2.40 2.69 3.04 3.44 35 (1.67) TCG 34.70 32.90 31.10 29.20 27.20 25.10 22.80 20.50 SDT 70.00 79.30 88.60 97.90 107.20 116.40 125.60 134.80 KW 1.48 1.70 1.91 2.15 2.41 2.70 3.05 3.45 40 (4.44) TCG 38.20 36.20 34.20 32.10 29.90 27.60 25.20 22.60 SDT 71.30 80.50 89.80 99.10 108.30 117.40 126.50 135.60 KW 1.49 1.70 1.92 2.16 2.42 2.72 3.06 3.45 45 (7.22) TCG 42.00 39.80 37.60 35.30 32.90 30.30 27.70 24.80 SDT 72.80 81.90 91.10 100.30 109.40 118.50 127.50 136.40 KW 1.50 1.72 1.94 2.18 2.44 2.73 3.07 3.46 50 (10.0) TCG 46.00 43.60 41.10 38.60 36.00 33.20 30.20 27.20 SDT 74.40 83.40 92.50 101.60 110.60 119.60 128.50 137.30 KW 1.52 1.74 1.96 2.20 2.46 2.75 3.08 3.47 55 (12.78) TCG 50.20 47.60 44.90 42.10 39.20 36.20 32.90 29.60 SDT 76.10 85.00 94.00 103.00 111.90 120.80 129.50 138.20 KW 1.54 1.76 1.98 2.22 2.48 2.77 3.10 3.48 24AHA448A30 30 (-1.11) TCG 41.50 39.50 37.40 35.40 33.20 30.80 28.20 25.40 SDT 73.40 82.60 91.90 101.20 110.40 119.50 128.60 137.50 KW 2.05 2.30 2.57 2.87 3.21 3.60 4.05 4.56 35 (1.67) TCG 45.70 43.40 41.20 38.90 36.50 33.90 31.10 28.10 SDT 75.10 84.30 93.40 102.60 111.70 120.80 129.70 138.60 KW 2.08 2.33 2.60 2.90 3.24 3.63 4.08 4.60 40 (4.44) TCG 50.10 47.70 45.20 42.70 40.10 37.20 34.20 30.90 SDT 77.00 86.00 95.10 104.10 113.20 122.10 131.00 139.70 KW 2.12 2.36 2.63 2.93 3.27 3.67 4.12 4.64 45 (7.22) TCG 54.80 52.20 49.50 46.70 43.80 40.70 37.40 33.80 SDT 78.90 87.80 96.80 105.80 114.70 123.50 132.20 140.80 KW 2.15 2.39 2.66 2.96 3.31 3.71 4.16 4.69 50 (10.0) TCG 59.90 56.90 54.00 51.00 47.80 44.40 40.70 36.80 SDT 80.90 89.80 98.60 107.50 116.30 125.00 133.60 142.00 KW 2.19 2.43 2.70 3.00 3.34 3.74 4.20 4.72 55 (12.78) TCG 65.20 62.00 58.80 55.40 51.90 48.20 44.20 39.90 SDT 83.10 91.80 100.50 109.30 117.90 126.50 134.90 143.20 KW 2.24 2.47 2.73 3.03 3.38 3.78 4.24 4.76 24AHA460A30 30 (-1.11) TCG 53.00 50.30 47.70 45.10 42.40 39.40 36.00 32.40 SDT 76.00 85.10 94.30 103.50 112.70 121.70 130.60 139.40 KW 2.59 2.90 3.23 3.61 4.03 4.52 5.08 5.71 35 (1.67) TCG 58.30 55.30 52.50 49.70 46.60 43.30 39.70 35.70 SDT 78.00 87.00 96.10 105.20 114.20 123.10 131.90 140.60 KW 2.64 2.94 3.28 3.65 4.08 4.58 5.14 5.78 40 (4.44) TCG 63.90 60.70 57.60 54.50 51.10 47.50 43.60 39.30 SDT 80.00 88.90 97.90 106.90 115.80 124.70 133.30 141.90 KW 2.69 2.99 3.32 3.70 4.14 4.63 5.20 5.84 45 (7.22) TCG 70.00 66.50 63.10 59.60 55.90 51.90 47.60 42.90 SDT 82.20 91.00 99.90 108.80 117.60 126.30 134.80 143.20 KW 2.74 3.04 3.38 3.76 4.19 4.69 5.27 5.91 50 (10.0) TCG 76.40 72.60 68.80 65.00 60.90 56.50 51.80 46.70 SDT 84.60 93.30 102.00 110.70 119.40 127.90 136.30 144.50 KW 2.80 3.10 3.43 3.81 4.25 4.76 5.33 5.97 55 (12.78) TCG 83.30 79.10 74.90 70.60 66.10 61.30 56.10 50.60 SDT 87.00 95.60 104.20 112.80 121.20 129.60 137.80 145.80 KW 2.86 3.15 3.49 3.87 4.31 4.82 5.39 6.04 * AHRI listing applies only to systems shown in Combination Ratings table. KW - Outdoor Unit Kilowatts Only. SDT - Saturated Temperature Leaving Compressor (°F) SST - Saturated Temperature Entering Compressor (°F/°C) TCG - Gross Cooling Capacity (1000 Btuh) 16 GUIDE SPECIFICATIONS GENERAL System Description Outdoor-mounted, air-cooled, split-system air conditioning unit suitable for ground or rooftop installation. Unit consists of a scroll-type hermetic compressor, an air-cooled coil, propeller-type condenser fan, and a control box. Unit will discharge supply air horizontally as shown on contract drawings. Unit will be used in a refrigeration circuit to match up to a packaged fan coil or furnace. Quality Assurance — Unit will be rated in accordance with the latest edition of AHRI Standard 210. — Unit will be certified for capacity and efficiency, and listed in the latest AHRI directory. — Unit construction will comply with latest edition of ANSI/ ASHRAE and with NEC. — Unit will be constructed in accordance with UL standards and will carry the UL label of approval. Unit will have c-UL approval. — Unit cabinet will be capable of withstanding Federal Test Method Standard No. 141 (Method 6061) 500-hr salt spray test. — Air-cooled condenser coils will be leak tested and pressure tested — Unit constructed in ISO9001 approved facility. Delivery, Storage, and Handling — Unit will be shipped as single package only and is stored and handled per unit manufacturer’s recommendations. Warranty (for inclusion by specifying engineer) — U.S. and Canada only. PRODUCTS Equipment — Factory assembled, single piece, air-cooled air conditioning unit. Contained within the unit enclosure is all factory wiring, piping, controls, compressor, refrigerant charge Puron (R-410A), and special features required prior to field start-up. Unit Cabinet — Unit cabinet will be constructed of galvanized steel and bonderized. Fans — Condenser fan will be direct-drive propeller type, discharging air horizontally. AIR-COOLED, SPLIT-SYSTEM AIR CONDITIONER 24AHA4 1-1/2 TO 5 NOMINAL TONS — Condenser fan motors will be totally enclosed, 1-phase type with class B insulation and permanently lubricated bearings. Shafts will be corrosion resistant. — Fan blades will be statically and dynamically balanced. — Condenser fan openings will be equipped with coated steel wire safety guards. Compressor — Compressor will be a scroll-type, hermetically sealed. — Compressor will be mounted on rubber vibration isolators. Condenser Coil — Condenser coil will be air cooled. — Coil will be constructed of aluminum fins mechanically bonded to copper tubes which are then cleaned, dehydrated, and sealed. Refrigeration Components — Refrigeration circuit components will include liquid-line front-seating shutoff valve with sweat connections, vapor-line front-seating shutoff valve with sweat connections, system charge of Puron (R-410A) refrigerant, and compressor oil. — Unit will be equipped with high-pressure switch and filter drier for Puron refrigerant. Operating Characteristics — The capacity of the unit will meet or exceed _____ Btuh at a suction temperature of _____ F/C. The power consumption at full load will not exceed _____ kW. — Combination of the unit and the evaporator or fan coil unit will have a total net cooling capacity of _____ Btuh or greater at conditions of _____ CFM entering air temperature at the evaporator at _____ F/C wet bulb and _____ F/C dry bulb, and air entering the unit at _____ F/C. — The system will have a SEER of _____ Btuh/watt or greater at DOE conditions. Electrical Requirements — Nominal unit electrical characteristics will be _____ v, single phase, 60 hz. The unit will be capable of satisfactory operation within voltage limits of _____ v to _____ v. — Nominal unit electrical characteristics will be _____ v, three phase, 60 hz. The unit will be capable of satisfactory operation within voltage limits of _____ v to _____ v. — Unit electrical power will be single point connection. — Control circuit will be 24v. Special Features — Refer to section of this literature identifying accessories and descriptions for specific features and available enhancements. Copyright 2016 Carrier Corp. 7310 W. Morris St. Indianapolis, IN 46231 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. Catalog No: 24AHA4-04PD Replaces: 24AHA4-03PD Edition Date: 09/16