HomeMy WebLinkAboutB16-0494_FC-1_1488558960.pdfFV4CPerformancet Series Fan CoilSizes 002 Thru 006
Product Data
PREMIUM ENVIRONMENTALLY
SOUND FAN COIL
The FV4C is the premium air handler combining the proven
technology of Carrier fan coils with environmentally sound
Purone refrigerant. The FV4C achieves an operational advantage
when the ECM (Electronically Commutated Motor) is combined
with a Carrier Performancet heat pump with Purone refrigerant.
With attention to quiet, efficient, and comfortable operation,
Carrier has developed a new benchmark for superior indoor
comfort and control.
Carrier’s heat pump and air conditioning systems now feature
Purone refrigerant (R--410A), the chlorine--free refrigerant that is
the future for the residential heating and cooling industry. The
FV4C using Purone refrigerant maximizes performance for
environmentally sound systems. In addition to environmental
safety, these systems are 30 to 40% more efficient than standard
heating and cooling systems, thereby combining excellence in
efficiency and environmental safety.
The FV4C provides these benefits due to Carrier’s command of
ECM technology. These motors are extremely efficient at all
speeds, and enable the FV4C to operate at the correct speed to
deliver airflow precisely, ensuring proper performance across a
wide range of duct static pressures. This adaptive efficiency also
makes installation quality easier to achieve for today’s demanding
homeowner.
Carrier’s command of ECM technology may be most evident in the
comfort advantages that ECM can deliver. Operation set up steps
on the Easy Selectt Board provide the installing technician with
alternatives to maximize comfort and efficiency. For true indoor
comfort, the homeowner can achieve command of both
temperature and humidity in cooling and heating modes.
Another feature which sets the FV4C apart is the factory--installed
TXV, which enhances efficiency and provides compressor
protecting operation at all recommended conditions. Grooved
tubing, louvered aluminum fins, and the large face areas of the
FV4C refrigerant coils also provide superior efficiency, for high
SEER and HSPF performance. Carrier leads the way in condensate
control, a hallmark of these multipoise fan coils. All of these
featured components are protected within a rugged, prepainted
metal cabinet lined with super thick, high density insulation. For
neat, high quality installations the unit exterior features sweat
refrigerant connections for simple leak free performance, and
multiple electrical entry for both high and low voltage service.
For superior technology and unmatched comfort, the
environmentally sound and efficient FV4C can’t be beat.
2
FEATURES
Environmentally Sound Refrigerant Technology
S Puronr, chlorine--free, non--ozone depleting refrigerant
S Thermostatic Expansion Valve (TXV) designed to maximize performance with Puronr refrigerant
Energy Efficient Operation
S Electronically Commutating Motor (ECM) operates efficiently at all speeds
S Maximizes efficiency of heating and cooling systems
S Ultra low power consumption during fan only operation
Indoor Weather Control
S Warm, comfortable heating air temperatures
S Unmatched humidity control, especially with Carrier’s thermostat with relative humidity controls
Airflow and Sound Technology
S Diffuser air discharge section for high airflow efficiency and quiet, smooth operation
S High duct static capability
S Unique cabinet design that meets new stringent regulations for air leakage. Meets requirements of a 2% cabinet leakage rate when tested at
1.0 inches of static pressure
Condensate Control and Disposal Technology
S Minimal standing waterless microbial growth for improved IAQ and reduced condensate line clogging and related condensate leakage
S Condensate fittings relocated away from turbulent airflow patterns at the blower entrance for improved condensate control performance
S Overflow feature for slope coil units allows condensate to exit the unit without damage to product under clogged primary and secondary
line conditions
S Tested for condensate disposal at conditions much more severe than those required by AHRI
S Primary and secondary drain connections to comply with HUD
S All pans constructed of an injection molded glass--filled polycarbonate engineered resin material, with brass drain connections.
S High density, super thick cabinetry insulation with vapor barrier
S Pre--painted galvanized sheet metal cabinet
Heat Transfer Technology
S Grooved tubing
S Lanced sine wave aluminum fins
S Discreet refined counter--flow refrigerant circuitry
S Bi--flow hard shut--off TXV metering device
Quality Assisting, Ease of Installation and Service Features
S All units multipoise
S Provision made for suspending from roof or ceiling joints
S Modular cabinet on 003 thru 006 units
S Sweat connections for leak free service
S Multiple electrical entry for application flexibility (high and low voltage)
S Low voltage terminal strip, to safely hold connections within the cabinet
S Cabinet construction features innovations designed to prevent cabinet sweating
Controls and Electrical Features
S Easy Selectt Board to maximize comfort, efficiency, and safe heater airflow operation
S Easy plug connection provided for quick installation of accessory heater packages
S 40VA 208/230v transformer
S Replaceable 5--amp blade--type auto fuse protects against transformer secondary short
Filter Features
S Factory supplied filter
S Cleanable polyester filter media
S Filter “springs” out for easy access -- no tools required
S Newly improved filter rack area -- filter door insulation added for an improved air sealFV4C
3
MODEL NUMBER NOMENCLATURE
123456789101112
FV4CNB003000
Product
F=FanCoil
Type
V=Puronr Refrigerant
Coil Type
Position T00 = Tin---plated
4=Multipoise 000 = Copper
L00 = Aluminum
Series
C Capacity
002 = 18---36,000
Electrical 003 = 24---42,000
N = 208/230v, 1ph---60 Hz 005 = 30---48,000
006 = 30---60,000
Cabinet/Insulation
B=Modular
F=Singlepiece
the environmentally sound refrigerant
Use of the AHRI Certified
TM Mark indicates a
manufacturer’s
participation in the
program For verification
of certification for individual
products, go to
www.ahridirectory.org.
SPECIFICATIONS
MODEL FV4C 002 003 005 006
COIL
Refrigerant Metering Device Puronr Refrigerant (R---410A)
TXV Size 2Ton 3Ton 4Ton 5Ton
Rows/Fins Per In.3 / 14.5
Face Area (Sq Ft)3.46 5.93 7.42
Configuration A Slope A
BLOWER & MOTOR
Air Discharge Upflow, Downflow, Horizontal
CFM (Nominal Clg/Htg)
525 / 470
700 / 630875 / 7851050 / 945
700 / 630
875 / 7851050 / 9451225 / 1100
875 / 785
1050 / 9451225 / 11001400 / 1260
1050 / 945
1225 / 11001400 / 12601750 / 1575
Motor HP (ECM)1/2 3/4
FILTER CLEANABLE
21---1/2” (546 mm) by 16---3/8” (417 mm)19---7/8” (505 mm)23---5/16” (585 mm)
CABINET CONFIGURATION OPTIONS
1Piece 1PieceorModular Modular FV4C
4 DIMENSIONSUNIT SIZEABCDEHJinmminmminmminmminmminmminmmFV4CNB00353---7/16135721---1/853719---1/448919---1/848619---3/1648728---5/1673519483FV4CNB00553---7/16135721---1/853719---1/448919---1/848619---3/1648728---5/16735——FV4CNB00659---3/16150324---11/1662722---3/457822---11/1657625---1/464234---1/16865——FV4CNF00242---11/16108417---5/844815---3/440015---5/839710---3/4273————FV4CNF00353---7/16135721---1/853719---1/448919---1/848619---3/16487——19483FV4CNF00553---7/16135721---1/853719---1/448919---1/848619---1/2495————FV4C
5 DIMENSIONSUNIT SIZEFGCOIL TYPESHIPPING WEIGHTinmminmmlbkgFV4CNB00326---15/1668427---1/2699SLOPE15068FV4CNB00526---15/1668427---1/2699A17278FV4CNB00632---15/1683732---5/8829A20794FV4CNF00218---9/1647118---1/4464A13561FV4CNF00326---15/1668427---1/2699SLOPE15068FV4CNF00527---1/469226---15/16684A17278FV4C
6
PERFORMANCE DATA
FV4C ADVANCED FAN COIL AIRFLOW DELIVERY CHART (CFM)
OPERATING MODE
UNIT SIZE
OUTDOOR
UNITCAPACITY
SINGLE—SPEEDAPPLICATION TWO—SPEED APPLICATION FAN ONLY
NominalA/C
Cooling
A/CCooling
Dehumidity
High Speed Low Speed
Lo Med HighNominal
A/CCooling
A/C
CoolingDehumidity
Nominal
A/CCooling
A/C
CoolingDehumidity
002
018 525 420 ————350 420 525
024 700 560 700 560 560 450 350 560 700
030 875 700 ————440 700 875
036 1050 840 1050 840 840 670 525 840 1050
003
024 700 560 700 560 560 450 415 560 700
030 875 700 ————440 700 875
036 1050 840 1050 840 840 670 525 840 1050
042 1225 980 ————610 980 1225
005
030 875 700 ————440 700 875
036 1050 840 1050 840 840 670 525 840 1050
042 1225 980 ————610 980 1225
048 1400 1120 1400 1120 1120 895 700 1120 1400
006
036 1050 840 1050 840 840 670 540 840 1050
042 1225 980 ————610 980 1225
048 1400 1120 1400 1120 1120 895 700 1120 1400
060 1750 1400 1750 1400 1400 1120 875 1400 1750
NOTES:1. The above airflows result with the AC, HP CFM ADJUST select jumper set on NOM.
2. Air flow can be adjusted +15% or ---10% by selecting HI or LO respectively for all modes except fan only.
3. Dry coil at 230 volts and with 10kW heater and filter installed.
4. Airflows shown are at standard air conditions.
*Consult ARI ratings before matching outdoor unit with FV4C fan coil.
FV4C ADVANCED FAN COIL AIRFLOW DELIVERY CHART (CFM)
OPERATING MODE
UNIT SIZE
OUTDOORUNIT
CAPACITY
SINGLE—SPEEDAPPLICATION TWO—SPEED APPLICATION FAN ONLY
Heat Pump
Comfort
Heat Pump
Efficiency
High Speed Low Speed
Lo Med HighHeat PumpComfort Heat PumpEfficiency Heat PumpComfort Heat PumpEfficiency
002
018 470 525 ————350 380 470
024 630 700 630 700 505 560 350 505 630
030 785 875 ————390 630 785
036 945 1050 945 1050 755 840 470 755 945
003
024 630 700 630 700 415 560 415 505 630
030 785 875 ————415 630 785
036 945 1050 945 1050 755 840 470 755 945
042 1100 1225 ————550 880 1100
005
030 785 875 ————425 630 785
036 945 1050 945 1050 755 840 470 755 945
042 1100 1225 ————550 880 1100
048 1260 1400 1260 1400 1010 1120 630 1010 1260
006
036 945 1050 945 1050 755 840 540 755 945
042 1100 1225 ————550 880 1100
048 1260 1400 1260 1400 1010 1120 630 1010 1260
060 1575 1750 1575 1750 1260 1400 785 1260 1575
NOTES:1. The above airflows result with the AC, HP CFM ADJUST select jumper set on NOM.
2. Air flow can be adjusted +15% or ---10% by selecting HI or LO respectively for all modes except fan only.
3. Dry coil at 230 volts and with 10kW heater and filter installed.
4. Airflows shown are at standard air conditions.FV4C
7
PERFORMANCE DATA (cont)
AIRFLOW DELIVERY CHART (CFM) — ELECTRIC HEATING MODES
FAN
UNIT SIZE
OUTDOORUNITCAPACITYBTUH
ELECTRIC HEATER kW RANGE
0 --- 5 0 --- 10 0 --- 15 0 --- 20
Lo Nom High Lo Nom High Lo Nom High Lo Nom High
002
18,000 625 625 625 675 675 ---------------------
24,000 650 725 835 ---725 835 875 875 875 ---------
30,000 815 905 1040 ---905 1040 900 900 1040 1100 1100 1100
36,000 980 1085 1250 980 1085 1250 980 1085 1250 1100 1100 1250
003
24,000 675 725 835 875 875 ---------------------
30,000 815 905 1040 875 905 1040 1100 1100 1100 ---------
36,000 980 1085 1250 980 1085 1250 1100 1100 1250 1225 1225 1250
42,000 1140 1270 1460 1140 1270 1460 1140 1270 1460 1225 1270 1460
FANUNIT SIZE
OUTDOOR
UNIT
CAPACITYBTUH
ELECTRIC HEATER kW RANGE
0 --- 10 0 --- 15 0 --- 20 0 --- 30
Lo Nom High Lo Nom High Lo Nom High Lo Nom High
005
30,000 975 975 1040 1100 1100 1100 ------------------
36,000 980 1085 1250 1100 1100 1250 1250 1250 1250 ---------
42,000 1140 1270 1460 1140 1270 1460 1250 1270 1460 ---------
48,000 1305 1450 1665 1305 1450 1665 1305 1450 1665 1500 1500 1665
006
36,000 1100 1100 1250 1350 1350 1350 ------------------
42,000 1140 1270 1460 1350 1350 1460 1525 1525 1525 ---------
48,000 1305 1450 1665 1350 1450 1665 1525 1525 1665 1750 1750 1750
60,000 1630 1810 2085 1630 1810 2085 1630 1810 2085 1750 1810 2085
NOTE: Lo, NOM, and HI refer to AC, HP CFM ADJUST selection.
--- Airflow not recommended for heater/system size.
MINIMUM CFM FOR ELECTRIC HEATER APPLICATION
FAN COIL UNIT
HEAT PUMP UNITSIZE
CFM
HEATER SIZE kW
5 8, 9, 10 15 18, 20 24, 30
002
Heater Only 625 625 725 875 —
018 625 625 ———
024 650 725 875 ——
030 800 875 875 1040 —
036 970 970 970 1040 —
003
Heater Only 675 700 1050 1050 —
024 675 875 ———
030 800 875 1100 ——
036 975 975 1100 1225 —
042 1125 1125 1125 1225 —
005
Heater Only 675 700 1050 1050 1400
018 800 875 1100 ——
036 975 975 1100 1225 —
042 1125 1125 1125 1225 —
048 1305 1305 1305 1305 1400
006
Heater Only 1050 1050 1050 1050 1750
018 1100 1100 1350 1350 —
042 1125 1125 1350 1350 —
048 1300 1300 1350 1465 1750
060 1625 1625 1625 1750 1750
NOTES:
1. Heater Only---Air conditioner with electric heater application.
2. These airflows are minimum acceptable airflows as UL listed. Actual airflow delivered will be per airflow delivery chart for Electric Heating Modes.FV4C
8
PERFORMANCE DATA (cont)
00
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.1 0.2 0.3 0.4 0.5 0.6
RETURN STATIC PRESSURE, IN.W.C.SUPPLY STATIC PRESSURE, IN.W.C.TOO HIGHRETURN STATICPRESSURE(DIFFICULT TO MAKE
TRAP)
ACCEPTABLE RANGE
A02296
ACCEPTABLE DUCT CONDITIONS
For satisfactory operation (specifically making dry secondary trap),
subject fan coils must be installed with duct systems which fall
within the “Acceptable Range” illustrated above.
The airflow performance charts for the FV4C fan coil depict
nominal airflow delivery for heating and cooling mode operation
versus duct system static pressure drop. Cooling mode operation is
shown as solid vertical lines for all 4 system size selections.
Heating mode operation for the 4 system size selections are shown
as dashed vertical lines.
The dotted curved lines are static pressure drop characteristics for
several fixed--duct systems. These lines can be used to predict the
system static pressure drop at any airflow given the actual drop at 1
known point.
For example, a duct system is designed for 0.15 in. water column
(in. w.c.) drop at 1200 CFM. The FV4CNF005 operating at
nominal cooling airflow would deliver 1050 CFM with a duct
system drop of 0.11 in. w.c.. (See point 1.) On the same duct
system, the FV4CNF005 operating at nominal heating airflow
would deliver 945 CFM with a duct system drop of 0.09 in. w.c.
(See point 2.)
This example is but one of many possible duct system designs. The
FV4CNF005 will deliver the above airflows against much higher
static pressures.
AIRFLOW PERFORMANCE
EXTERNAL STATIC PRESSURE (in. w.c.)2
1
945
SCFM
1050 1200
.15
NOM.
CLG
NOM.
HTGDUCT
SYSTEMS
036
A09339FV4C
9
400
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
500 600 700 800 900 1000 1100 1200 1300EXTERNAL STATIC PRESSURE (in. w.c.)SCFM
AIRFLOW PERFORMANCE
030024018 036
036
Hi Cooling
A09340
FV4CNF002
——— Nominal Cooling and Heat Pump Efficiency airflow for each size selection. Airflow can be adjusted +15% to ---10%.--- --- --- --- Nominal Heat Pump Comfort airflow for each size selection. Airflow can be adjusted +15% to --- 10%.
· --- · --- Maximum cooling airflow for largest size selection. Adjusted +15% from nominal.
······ FixedDuctSystems(SeedescriptionunderAcceptableDuctConditions.)FV4C
10
500
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
1.1
1.2
1.3
600 700 800 900 1000 1100 1200 1300 1400 1500EXTERNAL STATIC PRESSURE (in. w.c.)SCFM
AIRFLOW PERFORMANCE
030 042024036
042
Hi Cooling
A09341
FV4CN(B,F)003
——— Nominal Cooling and Heat Pump Efficiency airflow for each size selection. Airflow can be adjusted +15% to ---10%.
--- --- --- --- Nominal Heat Pump Comfort airflow for each size selection. Airflow can be adjusted +15% to --- 10%.
· --- · --- Maximum cooling airflow for largest size selection. Adjusted +15% from nominal.
······ FixedDuctSystems(SeedescriptionunderAcceptableDuctConditions.)FV4C
11
600
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
1.1
1.2
1.3
700 800 900 1000 1100 1200 1300 1400 1500 1600 1700EXTERNAL STATIC PRESSURE (in. w.c.)SCFM
AIRFLOW PERFORMANCE
042030036 048
048
Hi Cooling
A09342
FV4CN(B,F)005
——— Nominal Cooling and Heat Pump Efficiency airflow for each size selection. Airflow can be adjusted +15% to ---10%.
--- --- --- --- Nominal Heat Pump Comfort airflow for each size selection. Airflow can be adjusted +15% to --- 10%.
· --- · --- Maximum cooling airflow for largest size selection. Adjusted +15% from nominal.
······ FixedDuctSystems(SeedescriptionunderAcceptableDuctConditions.)FV4C
12
800
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
1.1
1.2
1.3
1.4
1.5
1.6
1.7
900 1000 12001100 1300 1400 1500 1600 1700 1800 1900 2000 2100EXTERNAL STATIC PRESSURE (in. w.c.)SCFM
AIRFLOW PERFORMANCE
036 042 048 060
060
Hi Cooling
A09343
FV4CNB006
——— Nominal Cooling and Heat Pump Efficiency airflow for each size selection. Airflow can be adjusted +15% to ---10%.
--- --- --- --- Nominal Heat Pump Comfort airflow for each size selection. Airflow can be adjusted +15% to --- 10%.
· --- · --- Maximum cooling airflow for largest size selection. Adjusted +15% from nominal.
······ FixedDuctSystems(SeedescriptionunderAcceptableDuctConditions.)FV4C
13
PERFORMANCE DATA (cont)
COOLING CAPACITIES (MBtuh)
UNITSIZE
EVAPCOILAIRCfmBF
SATURATED TEMPERATURE LEAVING EVAPORATOR (F/C)
35 / 2 40 / 4 45 / 7 50 / 10 55 /13
Evaporator Air — Entering Wet---Bulb Temperature
72_F
22C
67_F
19C
62_F
17C
72_F
22C
67_F
19C
62_F
17C
72_F
22C
67_F
19C
62_F
17C
72_F
22C
67_F
19C
62_F
17C
72_F
22C
67_F
19C
62_F
17C
002
500
0.04
40 32 26 36 28 22 32 24 18 27 19 14 21 13 11
18 18 19 16 16 17 14 14 15 12 12 13 10 10 11
6500.07
50 40 32 45 36 27 39 30 22 33 24 18 26 17 14
21 22 23 19 20 21 16 17 18 14 15 16 12 13 14
8750.10
58 49 38 53 42 32 46 35 27 39 28 22 31 20 18
24 26 28 22 24 25 19 21 22 17 19 19 15 16 18
10000.11
62 51 41 56 45 35 50 38 29 42 30 24 33 22 20
26 28 31 23 26 28 21 23 25 18 20 21 16 18 20
12500.13
67 55 45 61 49 39 54 42 33 46 34 28 37 25 24
29 33 36 27 30 33 24 27 30 22 24 26 19 21 24
003
800
0.20
59 48 38 53 42 32 46 35 24 39 27 20 30 18 16
28 29 31 25 27 28 22 23 24 19 20 20 16 16 16
10000.22
68 56 45 61 49 37 54 41 29 45 32 25 35 22 20
32 34 37 29 31 33 26 28 28 23 24 25 19 20 20
12000.25
75 62 49 68 54 42 60 45 34 50 36 29 40 25 23
35 39 42 32 36 38 29 32 33 26 28 29 22 23 23
14000.27
80 67 54 73 59 46 64 49 38 54 39 32 43 28 27
38 43 47 35 39 43 32 36 37 28 32 32 24 26 27
005
7500.04
61 49 39 55 43 33 48 37 27 41 29 20 33 21 17
27 27 28 24 25 25 21 22 22 18 18 18 15 15 15
950
0.06
74 60 48 67 53 40 59 45 33 50 35 25 39 24 21
32 34 35 29 30 31 25 26 27 22 23 23 18 18 19
11500.07
89 72 57 79 63 48 69 52 38 58 41 31 44 29 25
37 39 41 33 35 36 29 31 32 25 26 27 20 22 22
15000.10
103 84 66 92 73 56 81 61 46 67 48 39 52 34 31
43 46 49 38 41 44 34 37 39 29 32 33 25 27 27
17000.11
110 89 71 99 78 60 86 65 49 72 51 42 56 37 35
45 50 53 41 45 48 36 39 42 31 34 36 27 29 30
006
10500.01
77 62 50 69 55 43 61 47 35 52 38 27 41 27 22
34 36 37 31 32 33 27 28 29 23 25 24 20 20 20
1300
0.02
100 82 65 90 71 55 79 60 45 66 47 37 49 32 27
42 45 47 37 40 42 33 35 37 29 31 32 23 25 24
17500.04
117 96 77 106 84 65 93 71 53 78 56 46 60 40 34
48 53 57 44 48 52 39 43 46 34 38 39 29 31 31
20500.05
126 103 83 114 91 71 99 76 59 84 60 50 65 44 39
52 58 63 48 53 57 43 47 51 37 42 43 33 35 35
23000.06
132 108 87 119 95 75 105 80 63 88 63 54 70 47 42
55 62 68 50 57 61 45 51 54 40 45 46 35 39 38
BF --- Bypass Factor
--- Sensible Heat Capacity (1000 Btuh)
--- Gross Cooling Capacity (1000 Btuh)
NOTES:1. Contact manufacturer for cooling capacities at conditions
other than shown in table.
2. Formulas:
Leaving db = entering db --sensible heat cap.
1.09 x CFM
Leaving wb = wb corresponding to enthalpy of air leaving
coil (hlwb)
hlwb =hewb --total capacity (Btuh)
4.5xCFM
where hewb = enthalpy of air entering coil. Direct interpola-
tion is permissible. Do not extrapolate.
3. SHC is based on 80_F db temperature of air entering coil.
Below 80_F db, subtract (Correction Factor x CFM) from
SHC. Above 80_F db, add (Correction Factor x CFM) to
SHC.
4. Bypass Factor = 0 indicates no psychometric solution. Use
bypass factor of next lower EWB for approximation.
SHC CORRECTION FACTOR
BYPASSFACTOR
ENTERING AIR DRY--BULB TEMPERATURE _F(_C)
79 (26)78 (26)77 (25)76 (24)75 (24)Under75 (24)
81 (27)82 (28)83 (28)84 (29)85 (29)Over 85
Correction Factor
0.10 .098 1.96 2.94 3.92 4.91 Useformulashownbelow
0.20 0.87 1.74 2.62 3.49 4.36
0.30 0.76 1.53 2.29 3.05 3.82
Interpolation is permissible.Correction Factor = 1.09 x (1 --- BF) x (db --- 80)FV4C
14
PERFORMANCE DATA (cont)
ESTIMATED SOUND POWER LEVEL (dBA)*
UNIT
SIZE
CONDITIONS OCTAVE BAND CENTER FREQUENCY
CFM ESP 63 125 250 500 1000 2000 4000
FV --- 002
400 0.25 63.0 59.0 55.0 52.0 50.0 48.0 44.0
600 0.25 64.7 60.7 56.7 53.7 51.7 49.7 45.7
800 0.25 66.0 62.0 58.0 55.0 53.0 51.0 47.0
1000 0.25 67.0 63.0 59.0 56.0 54.0 52.0 48.0
1200 0.25 67.8 63.8 59.8 56.8 54.8 52.8 48.8
1400 0.25 68.4 64.4 60.4 57.4 55.4 53.4 49.4
FV --- 003
400 0.25 63.0 59.0 55.0 52.0 50.0 48.0 44.0
600 0.25 64.7 60.7 56.7 53.7 51.7 49.7 45.7
800 0.25 66.0 62.0 58.0 55.0 53.0 51.0 47.0
1000 0.25 67.0 63.0 59.0 56.0 54.0 52.0 48.0
1200 0.25 67.8 63.8 59.8 56.8 54.8 52.8 48.8
1400 0.25 68.4 64.4 60.4 57.4 55.4 53.4 49.4
636 0.25 65.0 61.0 57.0 54.0 52.0 50.0 46.0
FV --- 005
400 0.25 63.0 59.0 55.0 52.0 50.0 48.0 44.0
600 0.25 64.7 60.7 56.7 53.7 51.7 49.7 45.7
800 0.25 66.0 62.0 58.0 55.0 53.0 51.0 47.0
1000 0.25 67.0 63.0 59.0 56.0 54.0 52.0 48.0
1200 0.25 67.8 63.8 59.8 56.8 54.8 52.8 48.8
1400 0.25 68.4 64.4 60.4 57.4 55.4 53.4 49.4
1600 0.25 69.0 65.0 61.0 58.0 56.0 54.0 50.0
FV --- 006
600 0.25 64.7 60.7 56.7 53.7 51.7 49.7 45.7
800 0.25 66.0 62.0 58.0 55.0 53.0 51.0 47.0
1000 0.25 67.0 63.0 59.0 56.0 54.0 52.0 48.0
1200 0.25 67.8 63.8 59.8 56.8 54.8 52.8 48.8
1400 0.25 68.4 64.4 60.4 57.4 55.4 53.4 49.4
1600 0.25 69.0 65.0 61.0 58.0 56.0 54.0 50.0
1800 0.25 69.5 65.5 61.5 58.5 56.5 54.5 50.5
2000 0.25 70.0 66.0 62.0 59.0 57.0 55.0 51.0
2150 0.25 70.3 66.3 62.3 59.3 57.3 55.3 51.3
* Estimated sound power levels have been derived using the method described in the 1987 ASHRAE Systems & Applications Handbook, chapter 52, p. 52.7.
CFM --- Cubic Ft Per Minute
ESP --- External Static Pressure (in. w.c.)
RPM --- Revolutions Per Minute
AIRFLOW PERFORMANCE CORRECTION FACTORS
HEATER kW ELEMENTS
STATIC PRESSURECORRECTION (in. wc)
Sizes 002–005 Size 006
0 0 +.02 +.03
5 1 +.01 +.02
8, 10 2 0 0
9, 15 3 –.02 –.03
20 4 –.04 –.06
18, 24, 30 6 –.06 –.10
The FV4C airflow performance table was developed using fan coils with 10---kW electric heaters (2 elements) in the units. For fan coils with heaters made upof a different number of elements, the external available static at a given CFM from the table may be corrected by adding or subtracting pressure. Use tablefor this correction.
FACTORY--INSTALLED FILTER STATIC PRESSURE DROP (in. wc)
UNITSIZE
CFM
400 600 800 1000 1200 1400 1600 1800 2000
002 0.020 0.044 0.048 0.072 0.100 ————
003 —0.020 0.035 0.051 0.070 0.092 ———
005 ——0.035 0.051 0.070 0.092 0.120 ——
006 ———0.038 0.053 0.070 0.086 0.105 0.133FV4C
15
PERFORMANCE DATA (cont)
AIR DELIVERY PERFORMANCE CORRECTION COMPONENT PRESSURE DROP (IN. WC)AT INDICATED AIRFLOW (DRY TO WET COIL)
UNITSIZE
CFM
600 700 800 900 1000 1100 1200 1300 1400 1500 1600
002 0.012 0.016 0.022 0.028 0.034 0.040 0.049 ————
003 —0.026 0.034 0.042 0.052 0.063 0.075 0.083 0.091 0.098 0.110
005 —0.006 0.008 0.010 0.012 0.015 0.017 0.020 0.023 0.027 0.030
CFM
1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100
006 0.013 0.016 0.018 0.020 0.023 0.027 0.030 0.034 0.039 0.044 0.048
UNITS WITHOUT ELECTRICAL HEAT
UNIT SIZE VOLTS --- PHASE FLA MINCKTAMPS
BRANCH CIRCUIT
Min WireSize Awg*
Fuse/Ckt BkrAmps
002 208/230---1 4.3 5.4 14 15
003 208/230---1 4.3 5.4 14 15
005 208/230---1 4.3 5.4 14 15
006 208/230---1 6.8 8.5 14 15
* Use copper wire only to connect unit. If other than uncoated (non---plated) 75°C copper wire (solid wire for 10 AWG and smaller, stranded wire for larger than10 AWG) is used consult applicable tables of the National Electric Code (ANSI/NFPA 70).
NOTE: If branch circuit wire length exceeds 100 ft, consult NEC 210---19a to determine maximum wire length. Use 2% voltage drop.FLA — Full Load Amps
ELECTRIC HEATERS
HEATERPART NO.
kW@ 240V
VOLTS/PHASE STAGES (kWOPERATING)
INTERNAL
CIRCUITPROTECTION
FAN COIL
SIZE USEDWITH
HEATING
CAP. @230V‡
INTELLIGENTHEATCAPABLE†† (kW
OPERATING)
KFCEH0501N05 5 230/1 5 None All 15,700 —
KFCEH0801N08 8 230/1 8 None All 25,100 —
KFCEH0901N10 10 230/1 10 None All 31,400 —
KFCEH3001F15 15 230/1 5, 15 Fuses**All 47,100 5, 10, 15
KFCEH3201F20 20 230/1 5, 20 Fuses**All 62,800 5, 10, 15, 20
KFCEH2901N09 9 230/1*3, 9 None All 28,300 3, 6, 9
KFCEH1601315 15 230/3 5, 15 None All 47,100 —
KFCEH2001318 18 230/3 6, 12, 18 None All 56,500 —
KFCEH3401F24 24 230/3†8, 16, 24 Fuses 005, 006 78,500 8, 16, 24
KFCEH3501F30 30 230/3†10, 20, 30 Fuses 005, 006 94,200 10, 20, 30
KFCEH2401C05 5 230/1 5 Ckt Bkr All 15,700 —
KFCEH2501C08 8 230/1 8 Ckt Bkr All 25,100 —
KFCEH2601C10 10 230/1 10 Ckt Bkr All 31,400 —
KFCEH3101C15 15 230/1 5, 15 Ckt Bkr All 47,100 5, 10, 15
KFCEH3301C20 20 230/1 5, 20 Ckt Bkr All 62,800 5, 10, 15, 20
* Field convertible to 3 phase.
†These heaters field convertible to single phase.
‡Blower motor heat not included.
** Single point wiring kit required for these heaters in Canada.
††Heaters designated with kW Operating Values are Intelligent Heat capable when used with compatible thermostat.
ELECTRIC HEATER INTERNAL PROTECTION
HEATER kW FUSES QTY/SIZE CKT BKR QTY/SIZE*
5 —1/60
8 —1/60
9 ——
10 —1/60
15 2/30, 2/60 2/60
15 ——
18 ——
20 4/60 2/60
24 6/60 —
30 6/60 —
* All circuit breakers are 2 pole.FV4C
16ACCESSORY ELECTRIC HEATER ELECTRICAL DATAHEATERPART NO.kWPHASEINTERNALCIRCUITPROTEC-TIONHEATER AMPS208/230VBRANCH CIRCUITMin Ampacity208/230V**Min Wire Size (AWG)208/230V††Min Gnd Wire Size208/230VMax Fuse/Ckt Bkr Amps208/230VMax Wire Length208/230V (ft)‡‡SingleCircuitDual CircuitSingleCircuitDual CircuitSingleCircuitDual CircuitSingleCircuitDual CircuitSingleCircuitDual CircuitSingleCircuitDual Circuit240v208vL1,L2L3,L4L1,L2L3,L4L1,L2L3,L4L1,L2L3,L4L1,L2L3,L4L1,L2L3,L4KFCEH0501N0553.81None18.1/20.0——31.2/33.5——8/8——10/10——35/35——85/88——KFCEH2401C0553.81Ckt Bkr18.1/20.0——31.2/33.5——8/8——10/10——35/35——85/88——KFCEH0801N0886.01None28.9/32.0——44.7/48.5——8/8——10/10——45/50——59/60——KFCEH2501C0886.01Ckt Bkr28.9/32.0——44.7/48.5——8/8——10/10——45/50——59/60——KFCEH2901N09*96.81None32.8/36.0——49.5/53.5——8/6——10/10——50/60——54/87——KFCEH2901N09*‡96.83None18.8/20.8——32.0/34.5——8/8——10/10——35/35——83/85——KFCEH0901N10107.51None36.2/40.0——53.8/58.5——6/6——10/10——60/60——78/80——KFCEH2601C10107.51Ckt Bkr36.2/40.0——53.8/58.5——6/6——10/10——60/60——78/80——KFCEH3001F15*11511.31Fuse54.2/59.936.2/40.018.1/20.076.3/83.453.8/58.522.7/25.04/46/610/108/810/1010/1080/9060/6025/2588/8978/8075/76KFCEH3101C15*1511.31Ckt Bkr—36.2/40.018.1/20.0—53.8/58.522.7/25.0—6/610/10—10/1010/10—60/6025/25—78/8075/76KFCEH16013151511.33None31.3/34.6——47.7/51.8——8/6——10/10——50/60——56/90——KFCEH20013181813.53None37.6/41.5——55.5/60.4——6/6——10/8——60/70——76/77——KFCEH3201F20*12015.01Fuse72.3/79.936.2/40.036.2/40.098.9/108.453.8/58.545.3/50.03/26/68/88/610/1010/10100/11060/6050/5085/10978/8059/59KFCEH3301C20*2015.01Ckt Bkr—36.2/40.036.2/40.0—53.8/58.545.3/50.0—6/68/8—10/1010/10—60/6050/50—78/8059/59KFCEH3401F24*†2418.03Fuse50.1/55.4——71.2/77.8——4/4——8/8——80/80——94/95——2418.01Fuse86.7/95.5——116.9/127.9——1/1——6/6——125/150——115/116——KFCEH3501F30*†3022.53Fuse62.6/69.2——86.8/95.0——3/3——8/8——90/100——97/98——3022.51Fuse109.0/120.0——144.8/158.5——0/00——6/6——150/175——117/150——FIELD MULTIPOINT WIRING OF 24--AND 30--kW SINGLE PHASEHEATER PARTNO.kWPHASEHEATER AMPS208/230VMIN AMPACITY208/230V**MIN WIRE SIZE (AWG)208/230V††MIN GNDWIRE SIZE208/230VMAX FUSE/CKT BKRAMPS208/230VMAX WIRE LENGTH208/230V (FT)‡‡240V208VL1,L2L3,L4L5,L6L1,L2L3,L4L5,L6L1,L2L3,L4L5,L6L1,L2L3,L4L5,L6L1,L2L3,L4L5,L6KFCEH3401F24*†2418.0128.9/32.028.9/32.028.9/32.044.7/48.536.2/40.036.2/40.08/88/88/810/1045/5040/4040/4059/6073/7373/73KFCEH3501F30*†3022.5136.2/40.036.2/40.036.2/40.053.8/58.545.3/50.045.3/50.06/68/88/810/1060/6050/5050/5078/8059/5959/59* Heaters are Intelligent Heat capable when used with the FV fan coil and Comfort Zone IItor Infinity Controlt.{Field convertible to 1 phase, single or multiple supply circuit.}Field convertible to 3 phase.** Includes blower motor amps of largest fan coil used with heater.{{Copper wire must be used. If other than uncoated (non---plated), 75_C copper wire (solid wire for 10 AWG and smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of theNational Electric Code (ANSI/NFPA 70).}}Length shown is as measured 1 way along wire path between unit and service panel for a voltage drop not to exceed 2%.NOTES:1. Single circuit application of F15 and F20 heaters requires single---point wiring kit accessory.FV4C
17
ACCESSORIES
ITEM ACCESSORY PART NO.*FAN COIL SIZE USED WITH
1.Disconnect Kit KFADK0201DSC Cooling controls and heaters 3--- through 10---kW
2.Downflow Base Kit
KFACB0201CFB 002
KFACB0301CFB 003, 005
KFACB0401CFB 006
3.Downflow Conversion Kit
KFADC0201SLP 003
KFADC0401ACL 002, 005, 006
4.Single---Point Wiring Kit KFASP0101SPK Only with 15 --- and 20 --- kW Fused Heaters
5.Filter Kit (12 Pack)
KFAFK0212MED 002
KFAFK0312LRG 003, 005
KFAFK0412XXL 006
6.Fan Coil Filter Cabinet(Fan Coil Filter Media)
FNCCABCC0017(FILCCFNC0017)002
FNCCABCC0021(FILCCFNC0021)003, 005
FNCCABCC0024(FILCCFNC0024)006
7.Infinityt Air Purifier
(Infinityt Purifier Replacement Cartridge)
GAPABXCC1620
(GAPCCCAR1620)002
GAPABXCC2020
(GAPCCCAR2020)003, 005
GAPABXCC2420
(GAPCCCAR2420)006
8.PVC Condensate Trap Kit (50 pack)KFAET0150ETK All
9.Air Cleaner 240---volt Conversion Kit KEAVC0201240 All
10.Downflow/Horizontal Conversion Gasket Kit KFAHD0101SLP All
11.Airflow Sensor Kit (Air Cleaner)KEAAC0101AAA All
12.ECM Motor Test KFASD0301VSP All
13.Horizontal Water Management Kit (25 pack)KFAHC0125AAA All
14.Standard Filter Rack Kit
KFAFR0101FRM NA
KFAFR0201FRM 002
KFAFR0301FRM 003, 005
KFAFR0401FRM 006
* Factory authorized and listed, field installed.Accessory Kits Description Suggested and Required Use
1.Disconnect Kit
The kit is used to disconnect electrical power to the fan coil so service or maintenance may be performed safely.
SUGGESTED USE: Units for 3-- through 10--kW electric resistance heaters and cooling controls.
2.Downflow Base Kit
This kit is designed to provide a 1--in. (25MM) minimum clearance between unit discharge plenum, ductwork, and combustible mater-
ials. It also provides a gap--free seal with the floor.
REQUIRED USE: This kit must be used whenever fan coils are used in downflow applications.
3.Downflow Conversion Kit
Fan coils are shipped from the factory for upflow or horizontal--left applications. Downflow conversion kits provide proper condensate
water drainage and support for the coil when used in downflow applications. Separate kits are available for slope coils and A--coils.
REQUIRED USE: This kit must be used whenever fan coils are used in downflow applications.
4.Single Point Wiring Kit
The single point wiring kit acts as a jumper between L1 and L3 lugs, and between the L2 and L4 lugs. This allows the installer to run
2 heavy--gauge, high--voltage wires into the fan coil rather than 4 light--gauge, high--voltage wires.
SUGGESTED USE: Fan coils with 15-- and 20--kW fused heaters only.
5.Filter Kit (12 pack)
The kit consists of 12 fan coil framed filters. These filters collect large dust particles from the return air entering the fan coil and
prevents them from collecting on the coil. This process helps to keep the coil clean, which increases heat transfer and, in turn, the
efficiency of the system.
SUGGESTED USE: To replace filters in fan coils.
REQUIRED USE: All units unless a filter grille is used.
6.Fan Coil Filter Cabinet
This cabinet is mounted to the fan coil on the return air end and designed to slip over the outer fan coil casing. The cabinets are
insulated using the same insulation as production fan coils. They are designed for the removal of particulates from indoor air using
FILCCFNC00(14, 17, 21, 24) media filter cartridges. These fan coil media filter cartridge kits are designed for the removal of particles
from indoor air. The cartridge is installed in the return air duct next to the air handler or further upstream.
SUGGESTED USE: All fan coils.
7.Infinityt Air Purifier
The Infinity Air Purifier wires directly to fan coil and requires no duct transitions with Carrier units. These purifiers both capture and
kill airborne viruses, bacteria, mold spores, and allergens. It comes with an airflow sensor. Maintenance is limited to replacement of
the purification cartridge, GAPCCAR (1620/2020 or 2420), and inspection/brush cleaning of the ionization array.
SUGGESTED USE: All fan coils.FV4C
18
ACCESSORIES (cont)
8.Condensate Drain Trap Kit
This kit consists of 50 PVC condensate traps. Each trap is pre--formed and ready for field installation. This deep trap helps the system
make and hold proper condensate flow even during blower initiation.
SUGGESTED USE: All fan coils.
9.Air Cleaner 240--volt Conversion Kit
The AIRA electronic air cleaner comes ready for 115--v operation.
REQUIRED USE: This kit is required when running 240--volt circuit to air cleaner.
10.Downflow/Horizontal Conversion Gasket Kit
This kit provides the proper gasketing of units when applied in either a downflow (FE4A or FE5A) or horizontal (FE4A only) applica-
tion.
REQUIRED USE: Fan coils in either downflow or horizontal applications.
11.Airflow Sensor Kit (Air Cleaner)
The AIRA electronic air cleaner comes ready for 115--v operation
REQUIRED USE: This kit is required whenever an electronic air cleaner is used.
12.ECM Motor Test Kit
Operates variable speed blower at several speeds independent of circuit board and wiring harness.
13.Horizontal Water Management Kit
This kit provides proper installation of fan coils under conditions of high static pressure and high relative humidty.
SUGGESTED USE: All fan coils.
14.Standard Filter Rack Kit
This kit mounts in fan coil filter rack area and modifies the existing filter rack to support standard 1--in. filter sizes.
SUGGESTED USE: Fan coils using standard filter sizes.
Copyright 20014 Carrier Corp.S 7310 W. Morris St.S Indianapolis, IN 46231 Edition Date: 02/14 U.S. Export Classification: EAR99.
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
Catalog No: FV4C---03PD
Replaces: FV4C --- 02PDFV4C