Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
B16-0494_HWC-1_1488558960.pdf
HC2, HC3HOT WATER COIL --- CASEDMULTIPOISE Product Data A07331 Fig.1–ModelHC2/HC3 The SmartSourcet hydronic coil incorporates proven standards for reliable system operation and performance. The HC2 and HC3 are cased, horizontal, two and three row coils that are housed in a durable, 20 gauge, pre--painted taupe metallic cabinet to match the Carrier fan coils. The fully insulated cabinet provides for quiet, efficient operation. These multipoise coils offer the most in installation flexibility. FEATURES PERFORMANCE: Designed with performance in mind, these new hot water coils offer low pressure drops to enhance system performance and airflow characteristics. CABINET:Completely insulated and solid constructed, 20 gauge steel cabinet. CONNECTIONS:Piping connections accept 7/8” O.D. tubing. WARRANTY:All Carrier coils feature a limited five year warrantyonparts. 2 MODEL NUMBER NOMENCLATURE 1 --- 2 3 4 5 --- 6 7 --- 9 10 --- 12 13 14 15 --- 16 HC 2 A XX 017 050 A A AA Description # of Rows Major Series Not Used Cabinet Width Heating Capacity Variations Minor Series Package Hydronic Coil 2 --- 2 Rows3 --- 3 Rows A --- Series 017 --- 17” Cabinet021 --- 21” Cabinet024 --- 24” Cabinet 050 --- 50,000 BTU065 --- 65,000 BTU070 --- 70,000 BTU080 --- 80,000 BTU090 --- 90,000 BTU100 --- 100,000 BTU A --- Basic A --- Series AA --- One Pack DIMENSIONS 2.51” (64 mm) A07328 Fig. 2 – Models HC2 / HC3 DIMENSIONS UNIT SIZE A B HC2AXX017050 HC3AXX017065 18.45 in. 469 mm 16.24 in. 413 mm HC2AXX021070 HC3AXX021090 21.95 in. 558 mm 19.04 in. 484 mm HC2AXX024080HC3AXX024100 25.52 in.648 mm 22.60 in.574 mmHC2 / HC3 3 RATINGS AND PERFORMANCE Table 1 – Heating Capacity -- Hot Water Coils -- HC2AXX017050 EWT (F)GPM PD (FT) CFM625875 1125AIR ENTERING TEMPERATURE EDB (F)60 65 70 75 60 65 70 75 60 65 70 75 140 3.0 2.1 TC 24.10 22.62 21.13 19.64 28.45 26.71 24.97 23.21 31.72 29.79 27.85 25.90LDB95.3 98.2 101.0 103.9 89.8 93.0 96.2 99.5 85.8 89.3 92.8 96.2LW T 123.7 124.7 125.7 126.7 120.7 121.9 123.1 124.3 118.5 119.8 121.1 122.5 4.0 3.1 TC 25.48 23.90 22.32 20.74 30.46 28.59 26.71 24.83 34.30 32.20 30.09 27.98LDB97.3 100.0 102.8 105.5 91.9 95.0 98.1 101.2 87.9 91.3 94.6 97.9LWT127.1 127.9 128.7 129.5 124.5 125.5 126.4 127.4 122.6 123.7 124.7 125.8 5.0 4.0 TC 26.38 24.75 23.11 21.47 31.81 29.85 27.89 25.92 36.06 33.84 31.62 29.40LDB98.6 101.3 103.9 106.6 93.3 96.3 99.3 102.3 89.4 92.6 95.8 99.1LWT129.3 129.9 130.6 131.3 127.1 127.9 128.7 129.5 125.4 126.3 127.2 128.1 6.0 4.9 TC 27.03 25.35 23.67 21.99 32.78 30.76 28.74 26.71 37.34 35.05 32.75 30.44LDB99.6 102.2 104.8 107.4 94.3 97.3 100.2 103.1 90.4 93.6 96.8 99.9LWT130.9 131.4 132.0 132.6 128.9 129.6 130.3 131.0 127.4 128.1 128.9 129.7 160 3.0 2.1 TC 30.45 28.95 27.45 25.95 36.01 34.25 32.49 30.72 40.18 38.23 36.27 34.31LDB104.6 107.5 110.3 113.2 97.7 100.9 104.2 107.4 92.7 96.2 99.6 103.1LWT139.3 140.3 141.3 142.3 135.5 136.7 137.9 139.1 132.6 134.0 135.3 136.6 4.0 3.1 TC 32.14 30.55 28.96 27.37 38.49 36.60 34.71 32.82 43.38 41.26 39.14 37.01LDB107.0 109.8 112.5 115.3 100.3 103.4 106.5 109.6 95.3 98.7 102.0 105.3LW T 143.6 144.4 145.2 146.0 140.4 141.3 142.3 143.3 137.9 138.9 140.0 141.1 5.0 4.0 TC 33.25 31.60 29.96 28.31 40.15 38.18 36.20 34.22 45.56 43.33 41.09 38.85LDB108.7 111.3 114.0 116.7 102.0 105.1 108.1 111.0 97.1 100.3 103.6 106.8LWT146.4 147.1 147.8 148.4 143.6 144.4 145.2 146.0 141.4 142.3 143.2 144.1 6.0 4.9 TC 34.04 32.35 30.66 28.97 41.35 39.31 37.28 35.24 47.14 44.83 42.52 40.19LDB109.8 112.4 115.0 117.6 103.3 106.3 109.2 112.1 98.4 101.6 104.7 107.9LW T 148.4 149.0 149.6 150.1 145.9 146.6 147.3 148.0 144.0 144.7 145.5 146.3 180 3.0 2.1 TC 36.87 35.36 33.85 32.33 43.66 41.89 40.11 38.33 48.76 46.80 44.82 42.84LDB114.0 116.9 119.7 122.6 105.7 109.0 112.2 115.4 99.7 103.2 106.6 110.1LWT154.8 155.8 156.8 157.9 150.1 151.3 152.5 153.8 146.6 148.0 149.3 150.7 4.0 3.1 TC 38.87 37.27 35.67 34.07 46.61 44.71 42.81 40.90 52.58 50.45 48.31 46.17LDB116.9 119.7 122.4 125.2 108.8 111.9 115.0 118.1 102.8 106.2 109.5 112.8LW T 160.1 160.9 161.7 162.5 156.1 157.1 158.0 159.0 153.0 154.1 155.2 156.3 5.0 4.0 TC 40.18 38.53 36.87 35.21 48.58 46.60 44.61 42.62 55.17 52.92 50.68 48.42LDB118.8 121.5 124.2 126.8 110.9 113.9 116.9 119.9 104.9 108.2 111.4 114.7LWT163.5 164.2 164.9 165.6 160.1 160.9 161.7 162.5 157.4 158.3 159.2 160.1 6.0 4.9 TC 41.11 39.41 37.72 36.02 50.00 47.95 45.91 43.85 57.04 54.72 52.39 50.06LDB120.2 122.8 125.4 128.0 112.4 115.3 118.3 121.2 106.4 109.6 112.8 116.0LW T 165.9 166.5 167.1 167.7 162.9 163.6 164.3 165.0 160.5 161.3 162.1 162.9 LEGEND EDB -- Entering Dry--Bulb (F) EWT -- Entering Water Temperature (F) LDB -- Leaving Dry Bulb (F) LWT -- Leaving Water Temperature (F) TC -- Total Capacity (MBH)HC2 / HC3 4 Table 2 – Heating Capacity -- Hot Water Coils -- HC2AXX021070 EWT (F)GPM PD (FT) CFM6751138 1600AIR ENTERING TEMPERATURE EDB (F)60 65 70 75 60 65 70 75 60 65 70 75 140 5.0 3.9 TC 29.84 27.99 26.14 24.28 40.04 37.57 35.11 32.63 47.02 44.14 41.25 38.36LDB100.5 103.1 105.6 108.2 92.2 95.3 98.3 101.4 86.9 90.3 93.7 97.1LWT127.9 128.6 129.4 130.1 123.7 124.7 125.7 126.7 120.9 122.1 123.2 124.4 6.0 5.0 TC 30.56 28.66 26.76 24.86 41.42 38.87 36.32 33.75 49.01 46.00 42.99 39.97LDB101.5 104.0 106.5 108.9 93.3 96.3 99.3 102.3 88.0 91.4 94.7 98.0LWT129.7 130.3 130.9 131.6 126.0 126.8 127.7 128.6 123.4 124.4 125.4 126.5 7.0 6.2 TC 31.10 29.17 27.23 25.30 42.48 39.86 37.24 34.61 50.54 47.44 44.33 41.21LDB102.2 104.7 107.1 109.5 94.2 97.1 100.1 103.0 88.9 92.2 95.5 98.7LWT131.0 131.5 132.1 132.7 127.7 128.4 129.2 130.0 125.3 126.2 127.1 128.0 8.0 7.5 TC 31.52 29.56 27.60 25.64 43.31 40.64 37.96 35.28 51.76 48.58 45.39 42.19LDB102.8 105.2 107.6 110.0 94.8 97.7 100.6 103.5 89.6 92.8 96.1 99.3LWT132.0 132.5 133.0 133.5 129.0 129.7 130.4 131.0 126.9 127.7 128.5 129.3 160 5.0 3.9 TC 37.58 35.72 33.85 31.99 50.52 48.04 45.56 43.07 59.40 56.50 53.60 50.68LDB111.0 113.6 116.1 118.7 100.6 103.7 106.8 109.8 94.0 97.4 100.8 104.2LWT144.7 145.4 146.2 146.9 139.4 140.4 141.4 142.4 135.7 136.9 138.1 139.3 6.0 5.0 TC 38.46 36.56 34.64 32.73 52.23 49.67 47.10 44.52 61.87 58.84 55.81 52.77LDB112.2 114.7 117.2 119.7 102.0 105.0 108.0 111.0 95.4 98.7 102.1 105.4LWT146.9 147.6 148.2 148.9 142.2 143.1 144.0 144.9 138.9 140.0 141.0 142.0 7.0 6.2 TC 39.12 37.18 35.23 33.29 53.53 50.90 48.26 45.62 63.76 60.64 57.51 54.37LDB113.1 115.6 118.0 120.5 103.1 106.0 109.0 111.9 96.5 99.8 103.0 106.3LWT148.6 149.2 149.7 150.3 144.4 145.2 145.9 146.7 141.4 142.3 143.2 144.1 8.0 7.5 TC 39.63 37.66 35.69 33.72 54.55 51.87 49.18 46.48 65.26 62.06 58.85 55.64LDB113.8 116.2 118.6 121.0 103.9 106.8 109.7 112.6 97.3 100.6 103.8 107.0LWT149.9 150.4 150.9 151.4 146.1 146.8 147.5 148.1 143.3 144.2 145.0 145.8 180 5.0 3.9 TC 45.38 43.51 41.64 39.76 61.11 58.62 56.13 53.63 71.92 69.01 66.09 63.16LDB121.6 124.2 126.7 129.3 109.1 112.2 115.3 118.4 101.1 104.6 108.0 111.3LWT161.4 162.1 162.9 163.7 154.9 155.9 157.0 158.0 150.5 151.7 152.9 154.1 6.0 5.0 TC 46.42 44.51 42.59 40.67 63.15 60.57 57.99 55.40 74.86 71.82 68.77 65.72LDB123.0 125.5 128.0 130.5 110.8 113.8 116.8 119.8 102.8 106.2 109.5 112.8LWT164.1 164.8 165.4 166.1 158.4 159.3 160.2 161.1 154.4 155.4 156.5 157.5 7.0 6.2 TC 47.20 45.25 43.30 41.34 64.68 62.04 59.39 56.74 77.11 73.97 70.83 67.68LDB124.1 126.5 129.0 131.4 112.0 115.0 117.9 120.9 104.1 107.4 110.7 113.9LWT166.2 166.7 167.3 167.9 161.0 161.8 162.6 163.4 157.4 158.3 159.2 160.2 8.0 7.5 TC 47.80 45.83 43.85 41.87 65.89 63.19 60.49 57.79 78.88 75.67 72.45 69.23LDB124.9 127.3 129.8 132.2 113.0 115.9 118.8 121.7 105.1 108.4 111.6 114.8LWT167.7 168.2 168.8 169.3 163.1 163.8 164.5 165.2 159.8 160.6 161.4 162.2 LEGEND EDB -- Entering Dry--Bulb (F) EWT -- Entering Water Temperature (F) LDB -- Leaving Dry Bulb (F) LWT -- Leaving Water Temperature (F) TC -- Total Capacity (MBH)HC2 / HC3 5 Table 3 – Heating Capacity -- Hot Water Coils -- HC2AXX024080 EWT (F)GPM PD (FT) CFM10501400 1750AIR ENTERING TEMPERATURE EDB (F)60 65 70 75 60 65 70 75 60 65 70 75 140 5.0 4.0 TC 41.24 38.69 36.14 33.58 47.82 44.89 41.94 38.99 53.05 49.80 46.54 43.28LDB96.0 98.8 101.6 104.5 91.3 94.4 97.5 100.6 87.8 91.1 94.4 97.8LWT123.2 124.3 125.3 126.4 120.6 121.8 123.0 124.2 118.4 119.8 121.1 122.4 6.0 5.3 TC 42.56 39.92 37.29 34.64 49.67 46.61 43.55 40.48 55.38 51.99 48.58 45.16LDB97.1 99.9 102.6 105.4 92.5 95.5 98.6 101.6 89.0 92.3 95.5 98.8LWT125.6 126.5 127.4 128.3 123.2 124.2 125.3 126.3 121.2 122.4 123.6 124.7 7.0 6.6 TC 43.55 40.85 38.15 35.45 51.07 47.93 44.77 41.61 57.18 53.66 50.14 46.61LDB98.0 100.7 103.4 106.1 93.4 96.4 99.4 102.4 89.9 93.1 96.3 99.5LWT127.4 128.1 128.9 129.7 125.2 126.1 127.0 127.9 123.4 124.4 125.5 126.5 8.0 7.9 TC 44.33 41.58 38.83 36.07 52.18 48.96 45.74 42.51 58.60 54.99 51.38 47.76LDB98.7 101.3 104.0 106.6 94.1 97.1 100.0 103.0 90.7 93.8 97.0 100.1LWT128.7 129.4 130.1 130.8 126.8 127.6 128.4 129.2 125.1 126.0 127.0 127.9 160 5.0 4.0 TC 51.97 49.40 46.83 44.26 60.33 57.37 54.41 51.44 66.97 63.70 60.42 57.13LDB105.3 108.2 111.0 113.8 99.5 102.6 105.7 108.8 95.0 98.4 101.7 105.1LWT138.8 139.8 140.9 141.9 135.4 136.6 137.8 139.0 132.6 134.0 135.3 136.7 6.0 5.3 TC 53.59 50.94 48.29 45.64 62.61 59.54 56.46 53.37 69.86 66.44 63.02 59.58LDB106.7 109.5 112.3 115.0 100.9 104.0 107.1 110.1 96.6 99.8 103.1 106.4LWT141.8 142.7 143.6 144.5 138.7 139.7 140.8 141.8 136.2 137.4 138.6 139.7 7.0 6.6 TC 54.82 52.10 49.39 46.67 64.35 61.18 58.02 54.84 72.08 68.55 65.01 61.46LDB107.8 110.5 113.2 115.9 102.1 105.1 108.1 111.1 97.7 100.9 104.1 107.3LWT144.0 144.8 145.6 146.4 141.2 142.2 143.1 144.0 139.0 140.0 141.0 142.1 8.0 7.9 TC 55.77 53.01 50.24 47.48 65.71 62.48 59.24 56.00 73.84 70.22 66.59 62.95LDB108.6 111.3 114.0 116.6 103.0 105.9 108.9 111.8 98.6 101.8 105.0 108.1LWT145.8 146.5 147.2 147.9 143.2 144.1 144.9 145.7 141.2 142.1 143.0 143.9 180 5.0 4.0 TC 62.78 60.21 57.63 55.04 72.95 69.98 67.01 64.03 81.02 77.74 74.44 71.14LDB114.7 117.6 120.4 123.3 107.7 110.9 114.0 117.1 102.4 105.7 109.1 112.4LWT154.2 155.3 156.3 157.4 150.0 151.3 152.5 153.7 146.7 148.1 149.4 150.8 6.0 5.3 TC 64.72 62.05 59.39 56.72 75.67 72.59 69.49 66.40 84.48 81.05 77.61 74.16LDB116.4 119.2 122.0 124.7 109.5 112.6 115.6 118.7 104.2 107.5 110.8 114.0LWT157.9 158.8 159.7 160.6 154.1 155.2 156.2 157.3 151.1 152.3 153.4 154.6 7.0 6.6 TC 66.17 63.44 60.72 57.99 77.73 74.56 71.38 68.20 87.12 83.58 80.02 76.46LDB117.7 120.4 123.1 125.9 110.8 113.9 116.9 119.9 105.6 108.8 112.0 115.2LWT160.6 161.4 162.2 163.0 157.2 158.1 159.1 160.0 154.5 155.5 156.5 157.6 8.0 7.9 TC 67.29 64.52 61.75 58.97 79.35 76.11 72.86 69.61 89.21 85.58 81.93 78.29LDB118.7 121.4 124.0 126.7 111.9 114.9 117.8 120.8 106.7 109.9 113.0 116.2LWT162.7 163.5 164.2 164.9 159.6 160.5 161.3 162.1 157.1 158.0 159.0 159.9 LEGEND EDB -- Entering Dry--Bulb (F) EWT -- Entering Water Temperature (F) LDB -- Leaving Dry Bulb (F) LWT -- Leaving Water Temperature (F) TC -- Total Capacity (MBH)HC2 / HC3 6 Table 4 – Heating Capacity -- Hot Water Coils -- HC3AXX017065 EWT (F)GPM PD (FT) CFM625875 1125AIR ENTERING TEMPERATURE EDB (F)60 65 70 75 60 65 70 75 60 65 70 75 140 3.0 2.2 TC 30.77 28.86 26.95 25.03 36.75 34.49 32.23 29.96 41.06 38.55 36.03 33.50LDB105.0 107.3 109.6 111.8 98.4 101.1 103.8 106.4 93.5 96.5 99.5 102.5LWT119.2 120.5 121.8 123.0 115.1 116.6 118.2 119.7 112.2 113.9 115.6 117.3 4.0 3.2 TC 32.53 30.51 28.48 26.46 39.49 37.05 34.60 32.15 44.64 41.89 39.14 36.38LDB107.6 109.7 111.8 113.9 101.2 103.7 106.2 108.7 96.5 99.3 102.1 104.9LWT123.5 124.5 125.5 126.6 119.9 121.2 122.4 123.7 117.3 118.7 120.1 121.5 5.0 4.0 TC 33.68 31.58 29.48 27.38 41.30 38.74 36.18 33.62 47.07 44.17 41.26 38.34LDB109.3 111.3 113.3 115.3 103.1 105.5 107.9 110.3 98.4 101.1 103.8 106.5LWT126.3 127.2 128.0 128.9 123.2 124.3 125.3 126.3 120.9 122.1 123.2 124.4 6.0 5.1 TC 34.48 32.33 30.18 28.02 42.60 39.95 37.31 34.66 48.83 45.81 42.79 39.76LDB110.5 112.4 114.3 116.2 104.4 106.8 109.1 111.4 99.9 102.5 105.1 107.7LWT128.3 129.1 129.8 130.5 125.6 126.5 127.4 128.3 123.5 124.5 125.5 126.5 160 3.0 2.2 TC 38.80 36.88 34.95 33.03 46.42 44.14 41.86 39.57 51.90 49.37 46.83 44.28LDB116.8 119.1 121.4 123.6 108.4 111.1 113.8 116.5 102.4 105.4 108.4 111.4LWT133.6 134.9 136.2 137.5 128.4 129.9 131.5 133.1 124.7 126.4 128.1 129.8 4.0 3.2 TC 40.99 38.95 36.91 34.86 49.82 47.36 44.90 42.43 56.37 53.60 50.83 48.05LDB120.0 122.1 124.2 126.3 112.0 114.5 117.0 119.5 106.0 108.9 111.7 114.5LWT139.1 140.1 141.2 142.2 134.6 135.8 137.1 138.3 131.2 132.6 134.0 135.5 5.0 4.0 TC 42.40 40.28 38.17 36.05 52.07 49.49 46.91 44.33 59.39 56.47 53.54 50.60LDB122.1 124.1 126.1 128.1 114.3 116.7 119.1 121.5 108.5 111.2 113.9 116.6LWT142.7 143.6 144.4 145.3 138.7 139.8 140.8 141.9 135.7 136.9 138.1 139.3 6.0 5.1 TC 43.39 41.22 39.05 36.88 53.67 51.01 48.34 45.68 61.57 58.53 55.49 52.44LDB123.5 125.4 127.4 129.3 116.0 118.3 120.6 122.9 110.3 112.9 115.5 118.1LWT145.2 146.0 146.7 147.5 141.7 142.6 143.6 144.5 139.0 140.1 141.1 142.2 180 3.0 2.2 TC 46.92 44.98 43.04 41.10 56.20 53.90 51.60 49.30 62.86 60.31 57.76 55.20LDB128.7 131.0 133.2 135.5 118.6 121.4 124.1 126.7 111.3 114.3 117.3 120.3LWT147.9 149.2 150.5 151.9 141.5 143.1 144.7 146.2 136.9 138.7 140.4 142.2 4.0 3.2 TC 49.52 47.47 45.41 43.35 60.26 57.79 55.31 52.83 68.23 65.45 62.65 59.86LDB132.5 134.6 136.7 138.8 122.9 125.4 127.9 130.4 115.7 118.5 121.4 124.2LWT154.6 155.6 156.7 157.8 149.1 150.3 151.6 152.9 145.0 146.4 147.8 149.3 5.0 4.0 TC 51.19 49.06 46.93 44.80 62.94 60.35 57.75 55.15 71.84 68.90 65.95 62.99LDB134.9 136.9 138.9 140.9 125.7 128.1 130.5 132.9 118.7 121.4 124.1 126.7LWT159.0 159.9 160.7 161.6 154.2 155.2 156.3 157.4 150.5 151.7 152.9 154.1 6.0 5.1 TC 52.36 50.17 47.99 45.81 64.84 62.16 59.48 56.80 74.44 71.38 68.32 65.25LDB136.6 138.6 140.5 142.4 127.7 130.0 132.3 134.6 120.8 123.4 126.0 128.6LWT162.1 162.8 163.6 164.3 157.8 158.7 159.7 160.6 154.5 155.6 156.6 157.7 LEGEND EDB -- Entering Dry--Bulb (F) EWT -- Entering Water Temperature (F) LDB -- Leaving Dry Bulb (F) LWT -- Leaving Water Temperature (F) TC -- Total Capacity (MBH)HC2 / HC3 7 Table 5 – Heating Capacity -- Hot Water Coils -- HC3AXX021090 EWT (F)GPM PD (FT) CFM6751138 1600AIR ENTERING TEMPERATURE EDB (F)60 65 70 75 60 65 70 75 60 65 70 75 140 5.0 4.1 TC 37.72 35.36 33.00 30.65 51.66 48.47 45.27 42.07 61.21 57.45 53.67 49.89LDB111.2 113.1 115.0 116.8 101.5 104.1 106.5 109.0 95.0 97.9 100.8 103.7LWT124.7 125.6 126.6 127.5 119.0 120.3 121.6 122.9 115.1 116.7 118.2 119.7 6.0 5.3 TC 38.61 36.19 33.78 31.37 53.55 50.23 46.91 43.58 64.03 60.09 56.13 52.17LDB112.4 114.2 116.0 117.8 103.1 105.5 107.9 110.3 96.6 99.4 102.2 105.0LWT126.9 127.7 128.6 129.4 121.9 123.0 124.1 125.2 118.3 119.7 121.0 122.3 7.0 6.6 TC 39.27 36.81 34.35 31.89 54.97 51.56 48.15 44.73 66.20 62.11 58.01 53.91LDB113.3 115.1 116.8 118.5 104.2 106.5 108.9 111.2 97.9 100.6 103.3 106.0LWT128.6 129.3 130.0 130.7 124.0 125.0 126.0 127.0 120.8 122.0 123.2 124.4 8.0 8.0 TC 39.77 37.28 34.79 32.30 56.08 52.61 49.11 45.62 67.90 63.71 59.50 55.29LDB114.0 115.7 117.4 119.1 105.1 107.4 109.6 111.9 98.8 101.5 104.2 106.8LWT129.9 130.5 131.2 131.8 125.8 126.6 127.5 128.4 122.8 123.8 124.9 126.0 160 5.0 4.1 TC 47.45 45.07 42.70 40.33 65.11 61.89 58.67 55.45 77.21 73.42 69.63 65.82LDB124.4 126.3 128.2 130.1 112.4 114.9 117.4 119.8 104.2 107.1 110.0 112.9LWT140.6 141.6 142.6 143.5 133.4 134.7 136.0 137.4 128.5 130.0 131.6 133.1 6.0 5.3 TC 48.54 46.11 43.68 41.25 67.45 64.11 60.77 57.42 80.73 76.76 72.78 68.79LDB125.9 127.7 129.5 131.3 114.2 116.7 119.1 121.4 106.2 109.0 111.8 114.6LWT143.5 144.3 145.1 146.0 137.0 138.2 139.3 140.5 132.5 133.9 135.2 136.6 7.0 6.6 TC 49.35 46.88 44.41 41.93 69.21 65.77 62.34 58.90 83.41 79.30 75.18 71.06LDB127.0 128.8 130.5 132.3 115.7 118.0 120.3 122.6 107.7 110.5 113.2 115.9LWT145.6 146.3 147.1 147.8 139.8 140.8 141.8 142.8 135.7 136.9 138.1 139.3 8.0 8.0 TC 49.97 47.47 44.96 42.45 70.57 67.07 63.56 60.05 85.53 81.31 77.08 72.85LDB127.8 129.6 131.3 133.0 116.8 119.0 121.3 123.6 108.9 111.6 114.3 116.9LWT147.2 147.9 148.5 149.2 142.0 142.9 143.8 144.7 138.2 139.2 140.3 141.4 180 5.0 4.1 TC 57.24 54.86 52.47 50.09 78.67 75.44 72.20 68.96 93.36 89.55 85.74 81.92LDB137.7 139.6 141.5 143.4 123.3 125.8 128.3 130.8 113.4 116.3 119.2 122.1LWT156.5 157.5 158.5 159.4 147.7 149.0 150.3 151.7 141.6 143.2 144.8 146.3 6.0 5.3 TC 58.55 56.10 53.66 51.21 81.46 78.11 74.75 71.38 97.57 93.58 89.58 85.58LDB139.5 141.3 143.1 144.9 125.5 127.9 130.3 132.7 115.8 118.6 121.4 124.2LWT160.0 160.8 161.6 162.5 152.1 153.3 154.4 155.6 146.6 148.0 149.3 150.7 7.0 6.6 TC 59.50 57.01 54.53 52.04 83.55 80.11 76.65 73.20 100.7 8 96.65 92.51 88.37 LDB 140.8 142.5 144.3 146.1 127.2 129.5 131.9 134.2 117.7 120.4 123.1 125.8LWT162.6 163.3 164.0 164.7 155.5 156.5 157.5 158.5 150.4 151.6 152.9 154.1 8.0 8.0 TC 60.23 57.71 55.19 52.68 85.18 81.66 78.14 74.61 103.31 99.06 94.82 90.56 LDB 141.8 143.5 145.2 146.9 128.5 130.8 133.1 135.3 119.1 121.8 124.4 127.1LWT164.6 165.2 165.8 166.5 158.1 159.0 160.0 160.9 153.5 154.6 155.7 156.8 LEGEND EDB -- Entering Dry--Bulb (F) EWT -- Entering Water Temperature (F) LDB -- Leaving Dry Bulb (F) LWT -- Leaving Water Temperature (F) TC -- Total Capacity (MBH)HC2 / HC3 8 Table 6 – Heating Capacity -- Hot Water Coils -- HC3AXX024100 EWT (F)GPM PD (FT) CFM10501400 1750AIR ENTERING TEMPERATURE EDB (F)60 65 70 75 60 65 70 75 60 65 70 75 140 5.0 4.3 TC 47.90 44.93 41.96 38.98 55.81 52.37 48.93 45.47 62.05 58.25 54.43 50.60LDB101.8 104.3 106.7 109.2 96.5 99.3 102.1 104.9 92.5 95.5 98.6 101.6LWT120.5 121.7 123.0 124.2 117.3 118.7 120.1 121.5 114.8 116.3 117.9 119.4 6.0 5.6 TC 49.48 46.40 43.33 40.25 58.07 54.48 50.89 47.30 64.96 60.96 56.95 52.94LDB103.1 105.5 107.9 110.3 98.0 100.7 103.4 106.1 94.0 97.0 99.9 102.9LWT123.2 124.3 125.3 126.4 120.3 121.6 122.8 124.0 118.0 119.4 120.7 122.1 7.0 7.0 TC 50.66 47.51 44.36 41.20 59.78 56.09 52.39 48.68 67.18 63.04 58.89 54.73LDB104.2 106.5 108.8 111.1 99.1 101.8 104.4 107.0 95.1 98.0 100.9 103.8LWT125.3 126.2 127.1 128.0 122.7 123.7 124.8 125.9 120.5 121.7 122.9 124.1 8.0 8.5 TC 51.58 48.37 45.15 41.94 61.13 57.35 53.56 49.77 68.94 64.69 60.43 56.16LDB105.0 107.3 109.5 111.8 100.0 102.6 105.2 107.7 96.1 98.9 101.7 104.5LWT126.9 127.7 128.5 129.4 124.5 125.4 126.4 127.4 122.5 123.6 124.7 125.7 160 5.0 4.3 TC 60.32 57.33 54.34 51.34 70.35 66.89 63.42 59.95 78.26 74.43 70.59 66.74LDB112.6 115.1 117.6 120.0 106.0 108.8 111.6 114.4 100.9 104.0 107.1 110.1LWT135.4 136.6 137.8 139.0 131.3 132.7 134.1 135.5 128.0 129.6 131.2 132.7 6.0 5.6 TC 62.27 59.18 56.08 52.99 73.16 69.55 65.94 62.32 81.88 77.86 73.83 69.79LDB114.3 116.7 119.1 121.5 107.8 110.6 113.3 116.0 102.8 105.8 108.8 111.7LWT138.8 139.9 140.9 142.0 135.1 136.3 137.6 138.8 132.1 133.5 134.9 136.2 7.0 7.0 TC 63.73 60.56 57.41 54.22 75.28 71.57 67.85 64.12 84.64 80.48 76.31 72.13LDB115.6 117.9 120.3 122.5 109.2 111.9 114.5 117.2 104.3 107.2 110.1 113.0LWT141.4 142.3 143.3 144.2 138.0 139.1 140.2 141.3 135.3 136.5 137.7 139.0 8.0 8.5 TC 64.86 61.63 58.40 55.17 76.95 73.15 69.34 65.53 86.83 82.55 78.27 73.98LDB116.6 118.8 121.1 123.4 110.3 112.9 115.5 118.1 105.4 108.3 111.1 113.9LWT143.4 144.3 145.1 145.9 140.4 141.3 142.3 143.3 137.8 138.9 140.0 141.1 180 5.0 4.3 TC 72.83 69.89 66.87 63.81 85.01 81.54 78.06 74.57 94.61 90.76 86.91 83.04LDB123.5 126.1 128.5 131.0 115.6 118.4 121.2 124.0 109.5 112.6 115.6 118.7LWT150.1 151.3 152.5 153.8 145.1 146.5 147.9 149.4 141.1 142.7 144.3 145.9 6.0 5.6 TC 75.16 72.05 68.94 65.83 88.37 84.75 81.12 77.49 98.95 94.91 90.87 86.81LDB125.5 127.9 130.3 132.7 117.8 120.5 123.3 126.0 111.8 114.8 117.7 120.7LWT154.3 155.3 156.4 157.5 149.8 151.0 152.2 153.5 146.1 147.5 148.9 150.3 7.0 7.0 TC 76.89 73.71 70.52 67.33 90.91 87.17 83.44 79.69 102.2 5 98.07 93.88 89.69 LDB 127.0 129.4 131.7 134.1 119.5 122.1 124.8 127.4 113.5 116.4 119.3 122.2LWT157.5 158.4 159.3 160.3 153.3 154.4 155.5 156.6 150.0 151.2 152.5 153.7 8.0 8.5 TC 78.23 74.99 71.75 68.50 92.89 89.07 85.25 81.42 104.86 100.56 96.26 91.96 LDB 128.2 130.5 132.8 135.1 120.7 123.4 126.0 128.6 114.9 117.7 120.6 123.4LWT159.9 160.8 161.6 162.4 156.2 157.1 158.1 159.1 153.1 154.2 155.3 156.4 LEGEND EDB -- Entering Dry--Bulb (F) EWT -- Entering Water Temperature (F) LDB -- Leaving Dry Bulb (F) LWT -- Leaving Water Temperature (F) TC -- Total Capacity (MBH) Table 7 – HC Airside Pressure Drop HOT WATER CFM 2ROW 3ROW HC 017 625 0.0478 0.07188750.0950 0.1425 1125 0.1559 0.2339 HC 021 675 0.0508 0.150311380.0986 0.1480 1600 0.1971 0.2957 HC 024 1050 0.0571 0.0857 1400 0.1023 0.153417500.1605 0.2408All values are in inches of water.Pressure drop includes standard fiberglass filters.All pressure drops are with dry coil. Copyright 2007 Carrier Corp.S 7310 W. Morris St.S Indianapolis, IN 46231 Printed in U.S.A. Edition Date: 06/07 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. Catalog No: HC2AX---2PD Replaces: HC2AX--1PDHC2 / HC3