B16-0501_ME-1.1_1484940900.pdf
SCALE: 4 MECHANICAL MEZZANINE PLAN - EXISTING 1/4" = 1'-0" SCALE: 3 MECHANICAL MEZZANINE PLAN - NEW 1/4" = 1'-0" 36x42 EXH 24x18 EXH 26x18 EXH (E) B-1 (E) B-1 (E) B-1 (E) B-1 (E) B-1 (E) ET-1 (E) WH-(E) WH- (E) P-1 (E) P-1 (E) FS- 24x24 EXH DN. 36x42 EXH 24x18 EXH 26x18 EXH (EXIST) (E) B-1 (E) B-1 (E) B-1 (E) B-1 (E) EXT-1 (E) WH- (E) WH- P-1 P-1 (E) FS- (E) EXT- 24x24 EXH DN. (EXIST) SCALE: 2 ELECTRICAL MEZZANINE PLAN - EXISTING 1/4" = 1'-0" SCALE: 1 ELECTRICAL MEZZANINE PLAN - NEW 1/4" = 1'-0" REMOVE EXISTING BOILER AND ALL APPETENCIES. 36x42 EXH 24x18 EXH 26x18 EXH (E) B-1 (E) B-1 (E) B-1 (E) B-1 (E) B-1 (E) ET-1 (E) WH- (E) WH- (E) FS- (E) ET- 24x24 EXH DN. B-2 B-2 EXT-2 SMP-1 HX-1 4" FLUE/COMB. AIR TO CONCENTRIC VENT ON BUILDING SIDEWALL. EXISTING ELECTRICAL PANEL. MEP2 - 225A, 120/208V, 3 PHASE, 4 WIRE, 42 SPACE. 36x42 EXH 24x18 EXH 26x18 EXH (E) B-1 (E) B-1 (E) B-1 (E) B-1 (E) EXT-1 (E) WH-(E) WH- (E) FS- (E) EXT- 24x24 EXH DN. EXT-2 J-BOX FOR SM CONTROLLER, 120/1ɸ, 15A CB. B 2 B 2 SMP 1 J P 1a P 1b DEMO EXISTING PUMPS. (E) P-1 (E) P-1 DEMO EXISTING PUMPS. 20A/1P CB, MEPS - 16 REUSE EXISTING PUMP POWER - 20A/3P CB, MEP2 - 7, 9, 11. REUSE EXISTING PUMP POWER - 20A/3P CB, MEP2 - 8, 10, 12. POWER VIA SNOWMELT CONTROLLER. 20A/1P CB, MEP2 - 17 20A/1P CB, MEP2 - 18 BOILER SCHEDULE MARK SERVICE BOILER TYPE FUEL TYPE TURNDOWN RATIO HEATING CAPACITY L.W.T. (°F) E.W.T. (°F) BURNER VENT TYPE MANUFACTURER* & MODEL # ACCESSORIES REMARKS INPUT @ S.L. (MBH) OUTPUT @ ALT. MINIMUM A.F.U.E. HP VOLT/ PH B-2 HEATING WATER NATURAL GAS, CONDENSING NG 5:1 391 260 94 180 150 - 120/1 -LOCHINVAR KNIGHT XL KBN 400 A DIRECT VENT SIDEWALL MANUFACTURERS: * LOCHINVAR, TRIANGLE TUBE, PATTERSON KELLY, VIESSMANN OR BUDERUS GENERAL NOTES: A: CONDENSATE NEUTRALIZATION KIT, CONCENTRIC VENT KIT (SIDEWALL), CONSTANT SPEED BOILER CIRCULATION PUMP, BMS BACNET GATEWAY, 75 PSI PRV. B: HEAT EXCHANGER SCHEDULE MARK SERVICE TYPE SIDE GPM FLUID E.W.T. (°F) L.W.T. (°F) MAX PRESSURE DROP (PSI) FOULING FACTOR HEAT TRANSFER (MBH) MANUFACTURER* & MODEL # ACCESSORIES REMARKS HX-1 SNOWMELT HEAT EXCHANGER BRAZED PLATE HOT 20 20% PG 180 150 3.0 1.0 300 TACO TFP5X12-40 OR EQUAL COLD 23 50% PG 100 130 4.0 HOT - - - - - MANUFACTURERS: * B&G, PATTERSON-KELLY, TACO, TRANTER GENERAL NOTES: A: B: MISCELLANEOUS MECHANICAL EQUIPMENT SCHEDULE MARK SERVICE TYPE CAPACITY ELECTRICAL MANUFACTURER* & MODEL # ACCESSORIES REMARKS HP (W) VOLT/ PH SMC SNOWMELT CONTROLLER N/A N/A 320 VA 120/1 SNOWMELT CONTROLLER TEKMAR-680_C OUTDOOR SENSOR TEKMAR 070 - EXT-2 EXPANSION TANK BLADDER 8 GAL. N/A N/A TACO CX30-125 OR EQUAL - 5 GAL ACCEPTABLE; 125 PSIG WORKING PRESSURE; 240°F MAX. OPERATING TEMP. MANUFACTURERS: * GENERAL NOTES: A: B: PUMP SCHEDULE MARK SERVICE TYPE GPM TDH (FT) FLUID MOTOR MANUFACTURER* & MODEL # ACCESSORIES REMARKS HP (W) RPM VOLT/ PH SMP-1 SOWMELT CIRC. PUMP IN-LINE 23 25 20% PG (180 W) VFD 120/1 GUNDFOS MAGNAI 32-100F VARIABLE SPEED 60HZ, 1.61A (MAX.) P-1a & 1b HEATING WATER IN-LINE 145 55 20%PG 5HP VFD 208/3 TACO SKV3007-1760-5 SELF SENSING VARIABLE SPEED 3x3x7.5 MANUFACTURERS: * B&G, GRUNDFOS, TACO OR AURORA EQUIVALENT GENERAL NOTES: A: B: Designed: Reviewed: Project No: DAL DAL 8739.00 PH-002 Issued: PERMIT SET 09.23.2016 S:\BGPROJECTS\8739.00 VVMC – ON CALL CONSULTING SERVICES\CAD\DRAWINGS\VVMC - MPB - BOILER UPGRADE\873900ME11.DWG 12.21.16 10:17:14 AM Scale: As Shown VVMC - MPB BOILER UPGRADE VAIL, COLORADO 81657 Sheet Title: Sheet No: Date: © 2016 BG BUILDINGWORKS INC. Current Issue: PERMIT SET ALBUQUERQUE | AVON | DENVER | FORT COLLINS 303.278.3820 www˛bgbuildingworks˛com 09.23.2016 MECHANICAL / ELECTRICAL FLOOR PLANS ME-1.1 01/20/17