Loading...
HomeMy WebLinkAboutB17-0015_A2.2_1489608780.pdfGENERAL ASSEMBLY AND FINISH SYSTEMS Note: Reference structural drawings and specifications for all fasteners within all building assemblies including but not limited to nails, screws & bolts for size (length, diameter & shank), type, style & spacing. Contact Architect with any discrepancies prior to ordering and installation of product in assembly. All products are to be installed in strict conformance with product specifications, requirements and warranties. Contact Architect with any discrepancies prior to ordering product. Refer to both architectural and structural drawings for assembly information. Structural drawings shall govern over architectural drawings regarding framing. Architectural drawings shall govern over structural drawings regarding wall location dimensions, fire, sound and weather proofing related details. Contact Architect immediately with any discrepancy prior to installation of the work. Install all fire rated assemblies per their listings as referenced with options shown. The following assembly narratives are general. WALL SYSTEMS: FLOOR ASSEMBLIES: F1-W VINYL PLANK ON EXISTING FLOOR ASSEMBLY Vinyl plank installed per manufacturer's specifications,over 1/4" AcoustiMat II underlayment on 3/4" T & G APA rated (exposure 1) wood structural panels over Pre-Manufactured floor trusses at 16" o.c. maximum spacing (Re: Structural Drawings.) Install (1) layer 5/8" Type "x"gypsum board ceiling on Resilient Channels 7/8" deep, 26 gauge galvanized steel @ 16"o.c. on U/S of trusses. F1-C CARPET ON EXISTING FLOOR ASSEMBLY Carpet and pad, installed per manufacturer's specifications, over 1/4" AcoustiMat II underlayment on 3/4" T & G APA rated (exposure 1) wood structural panels over Pre-Manufactured floor trusses at 24" o.c. maximum spacing (Re: Structural Drawings.) Install (1) layer 5/8" Type "X" gypsum board ceiling on Resilient Channels 7/8" deep, 26 gauge galvanized steel @ 16"o.c. on U/S of trusses. C1 GYPSUM BOARD CEILING CONSTRUCTION (1Hr-Rated) UL DESIGN NO. L521 & UL P533 5/8" Gypsum board on 7/8" furring channels attached to underside of floor trusses or joists. (TYPICAL FOR ALL CEILINGS) Note: Typical ceiling system included in floor assemblies. Re: floor assemblies. CEILING SYSTEMS: FLOOR SYSTEMS: Note: Reference structural drawings and specifications for all fasteners within all building assemblies including but not limited to nails, screws & bolts for size (length, diameter & shank), type, style & spacing. Contact Architect with any discrepancies prior to ordering and installation of product in assembly. All products are to be installed in strict conformance with product specifications, requirements and warranties. Contact Architect with any discrepancies prior to ordering product. Refer to both architectural and structural drawings for assembly information. Structural drawings shall govern over architectural drawings regarding framing. Architectural drawings shall govern over structural drawings regarding wall location dimensions, fire, sound and weather proofing related details. Contact Architect immediately with any discrepancy prior to installation of the work. Install all fire rated assemblies per their listings as referenced with options shown. The following assembly narratives are general. NOTES ** Interior Walls Studs: 4 - 2x4 Wood Studs, 3 5/8" Metal Studs 6 - 2x6 Wood Studs, 6" Metal Studs 8 - 2x8 Wood Studs RE: See wall tags for stud sizes. **** Use water and mold resistant non-paper-faced substrate at shower walls and plumbing walls; moisture resistant non-paper-faced substrate at all other bathroom and restroom walls; water, mold, and indentation resistant non-paper-faced underlayment for all carpet, vinyl, and tile interior floor covering over slab on grade where recommended by manufacturer. Maintain required fire-rating. Refer to Structural Drawings for Bearing Walls and Shear Walls. RATED ASSEMBLIES (EXTERIOR): W1-1 CEMENTITIOUS SIDING @ RATED EXTERIOR WALLS Cementitious siding over (1) layer of Tyvek building wrap on structural sheathing (per structural design) @ exterior face of 2x6 dimensional lumber studs w/ min. R-21 closed cell spray-in foam insulation between studs. (1) layer 5/8" gypsum board @ interior face of studs. Interior finish will be paint or FRP panels, see room finish schedule for finish. (Re: Structural for size and spacing of studs and sheathing). W1-2 STUCCO @ RATED EXTERIOR WALLS 3 coat stucco system over self-furring metal lathe over 15 lb asphaltic building paper, 2x6 dimensional lumber studs w/ R-21 closed cell spray-in foam insulation between studs. (1) layer 5/8" gypsum board @ interior face of studs. (Re: Structural for size and spacing of studs and sheathing). W1-3 CEMENTITIOUS SIDING ON BOTH SIDES @ EXTERIOR WALLS Cementitious siding over (1) layer of Tyvek building wrap on structural sheathing (per structural design) @ both exterior faces of 2x6 dimensional lumber studs w/ min. R-21 closed cell spray-in foam insulation between studs. (Re: Structural for size and spacing of studs and sheathing). W1-4 STUCCO ON CMU @ RATED EXTERIOR WALLS 3 coat stucco system over self-furring metal lathe over 15 lb asphaltic building paper, on structural sheathing (per structural design) over 2x4 dimensional lumber studs w/ R-21 closed cell spray-in foam insulation between studs. Stud wall over 8" CMU wall, interior CMU face to be painted and recieve vinyl base. (Re: Structural for size and spacing of studs and sheathing). NON-RATED ASSEMBLIES (INTERIOR): W3-*** GYPSUM BOARD PARTITION ON 2X METAL STUDS (Non-Rated) (1) Layer 5/8" gypsum board**** on each side of 2x cold formed metal studs at non-bearing walls, demising bedrooms and living areas. Sound batt insulation. (Re. Structural for size and spacing). W4-*** GYPSUM BOARD PARTITION ON 2X DIMENSIONAL LUMBER STUDS (Non-Rated) (1) Layer 5/8" gypsum board**** on each side of 2x dimensional lumber studs at non-bearing walls, demising bedrooms and living areas. Sound batt insulation. (Re. Structural for size and spacing). W5- GYPSUM BOARD OVER FURRING (Non-Rated) (1) Layer 5/8" gypsum board**** over 1 1/2" metal furring strips @ 16" O.C. with 1 1/2" rigid insulation. (Re. Structural for size and spacing). (1Hr-Rated), R-50 R1 NEW METAL ROOF CONSTRUCTION: New metal roof to match existing metal roof. Install over Vycor ice and water shield. Note: Install ice and water 24" up at vertical wall interface. Typical. Note: Install snow retention system and heat tape in accordance with manufacturer's instructions. 110 MPH Wind resistance (ASTM D 3161), Class 4 impact resistance (UL 2218), ICC-ES (ESR-2119), Miami Dade Code Approval ROOF SYSTEMS: 5/8" GYPSUM WALL BOARD 3 5/8" W3-4 3 5/8" METAL STUD, SEE PLANS AND WALL TAG FOR STUD SIZE, TYP. SOUND BATTS 5/8" GYPSUM WALL BOARD 6" W3-6 6" METAL STUD, SEE PLANS AND WALL TAG FOR STUD SIZE, TYP. SOUND BATTS 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 616 W LIONSHEAD CIRCLE VAIL, COLORADO 81657 A2.2 WALL ASSEMBLY THE LITTLE DINER Project #: 1658 10/20/16 PERMIT SET 1 1/2" = 1'-0" 1 WALL ASSEMBLY W3-4 - 3 5/8" METAL STUD INTERIOR PARTITION 1 1/2" = 1'-0" 2 WALL ASSEMBLY W3-6 - 6" METAL STUD INTERIOR PARTITION 03/15/17