HomeMy WebLinkAboutB17-0015_A2.2_1489608780.pdfGENERAL ASSEMBLY AND FINISH SYSTEMS
Note: Reference structural drawings and specifications for all fasteners within all building assemblies including but not
limited to nails, screws & bolts for size (length, diameter & shank), type, style & spacing. Contact Architect with any
discrepancies prior to ordering and installation of product in assembly. All products are to be installed in strict conformance
with product specifications, requirements and warranties. Contact Architect with any discrepancies prior to ordering product.
Refer to both architectural and structural drawings for assembly information. Structural drawings shall govern over
architectural drawings regarding framing. Architectural drawings shall govern over structural drawings regarding wall location
dimensions, fire, sound and weather proofing related details. Contact Architect immediately with any discrepancy prior to
installation of the work. Install all fire rated assemblies per their listings as referenced with options shown. The following
assembly narratives are general.
WALL SYSTEMS:
FLOOR ASSEMBLIES:
F1-W VINYL PLANK ON EXISTING FLOOR ASSEMBLY
Vinyl plank installed per manufacturer's specifications,over 1/4" AcoustiMat II underlayment on 3/4" T & G APA rated
(exposure 1) wood structural panels over Pre-Manufactured floor trusses at 16" o.c. maximum spacing (Re: Structural Drawings.)
Install (1) layer 5/8" Type "x"gypsum board ceiling on Resilient Channels 7/8" deep, 26 gauge galvanized steel @ 16"o.c. on U/S
of trusses.
F1-C CARPET ON EXISTING FLOOR ASSEMBLY
Carpet and pad, installed per manufacturer's specifications, over 1/4" AcoustiMat II underlayment on 3/4" T & G APA rated
(exposure 1) wood structural panels over Pre-Manufactured floor trusses at 24" o.c. maximum spacing (Re: Structural
Drawings.) Install (1) layer 5/8" Type "X" gypsum board ceiling on Resilient Channels 7/8" deep, 26 gauge galvanized
steel @ 16"o.c. on U/S of trusses.
C1 GYPSUM BOARD CEILING CONSTRUCTION
(1Hr-Rated) UL DESIGN NO. L521 & UL P533
5/8" Gypsum board on 7/8" furring channels attached to underside of floor trusses or joists.
(TYPICAL FOR ALL CEILINGS) Note: Typical ceiling system included in floor assemblies. Re: floor assemblies.
CEILING SYSTEMS:
FLOOR SYSTEMS:
Note: Reference structural drawings and specifications for all fasteners within all building assemblies including but not limited to nails, screws & bolts for size (length, diameter & shank), type, style & spacing. Contact Architect with any discrepancies
prior to ordering and installation of product in assembly. All products are to be installed in strict conformance with product specifications, requirements and warranties. Contact Architect with any discrepancies prior to ordering product. Refer to both
architectural and structural drawings for assembly information. Structural drawings shall govern over architectural drawings regarding framing. Architectural drawings shall govern over structural drawings regarding wall location dimensions, fire, sound
and weather proofing related details. Contact Architect immediately with any discrepancy prior to installation of the work. Install all fire rated assemblies per their listings as referenced with options shown. The following assembly narratives are general.
NOTES
** Interior Walls Studs:
4 - 2x4 Wood Studs, 3 5/8" Metal Studs
6 - 2x6 Wood Studs, 6" Metal Studs
8 - 2x8 Wood Studs
RE: See wall tags for stud sizes.
**** Use water and mold resistant non-paper-faced substrate at shower walls and plumbing walls; moisture resistant
non-paper-faced substrate at all other bathroom and restroom walls; water, mold, and indentation resistant
non-paper-faced underlayment for all carpet, vinyl, and tile interior floor covering over slab on grade where
recommended by manufacturer. Maintain required fire-rating.
Refer to Structural Drawings for Bearing Walls and Shear Walls.
RATED ASSEMBLIES (EXTERIOR):
W1-1 CEMENTITIOUS SIDING @ RATED EXTERIOR WALLS
Cementitious siding over (1) layer of Tyvek building wrap on structural sheathing (per structural design) @
exterior face of 2x6 dimensional lumber studs w/ min. R-21 closed cell spray-in foam insulation between studs.
(1) layer 5/8" gypsum board @ interior face of studs. Interior finish will be paint or FRP panels, see room
finish schedule for finish.
(Re: Structural for size and spacing of studs and sheathing).
W1-2 STUCCO @ RATED EXTERIOR WALLS
3 coat stucco system over self-furring metal lathe over 15 lb asphaltic building paper, 2x6 dimensional
lumber studs w/ R-21 closed cell spray-in foam insulation between studs. (1) layer 5/8" gypsum board @
interior face of studs. (Re: Structural for size and spacing of studs and sheathing).
W1-3 CEMENTITIOUS SIDING ON BOTH SIDES @ EXTERIOR WALLS
Cementitious siding over (1) layer of Tyvek building wrap on structural sheathing (per structural design) @
both exterior faces of 2x6 dimensional lumber studs w/ min. R-21 closed cell spray-in foam insulation between
studs. (Re: Structural for size and spacing of studs and sheathing).
W1-4 STUCCO ON CMU @ RATED EXTERIOR WALLS
3 coat stucco system over self-furring metal lathe over 15 lb asphaltic building paper, on structural sheathing
(per structural design) over 2x4 dimensional lumber studs w/ R-21 closed cell spray-in foam insulation between
studs. Stud wall over 8" CMU wall, interior CMU face to be painted and recieve vinyl base. (Re: Structural for
size and spacing of studs and sheathing).
NON-RATED ASSEMBLIES (INTERIOR):
W3-*** GYPSUM BOARD PARTITION ON 2X METAL STUDS
(Non-Rated)
(1) Layer 5/8" gypsum board**** on each side of 2x cold formed metal studs at non-bearing walls, demising
bedrooms and living areas. Sound batt insulation. (Re. Structural for size and spacing).
W4-*** GYPSUM BOARD PARTITION ON 2X DIMENSIONAL LUMBER STUDS
(Non-Rated)
(1) Layer 5/8" gypsum board**** on each side of 2x dimensional lumber studs at non-bearing walls, demising
bedrooms and living areas. Sound batt insulation. (Re. Structural for size and spacing).
W5- GYPSUM BOARD OVER FURRING
(Non-Rated)
(1) Layer 5/8" gypsum board**** over 1 1/2" metal furring strips @ 16" O.C. with 1 1/2" rigid insulation.
(Re. Structural for size and spacing).
(1Hr-Rated), R-50
R1 NEW METAL ROOF CONSTRUCTION:
New metal roof to match existing metal roof. Install over Vycor ice and water shield.
Note: Install ice and water 24" up at vertical wall interface. Typical.
Note: Install snow retention system and heat tape in accordance with manufacturer's instructions.
110 MPH Wind resistance (ASTM D 3161), Class 4 impact resistance (UL 2218), ICC-ES (ESR-2119), Miami Dade
Code Approval
ROOF SYSTEMS:
5/8" GYPSUM
WALL BOARD
3 5/8"
W3-4
3 5/8" METAL STUD,
SEE PLANS AND WALL TAG
FOR STUD SIZE, TYP.
SOUND BATTS
5/8" GYPSUM
WALL BOARD
6"
W3-6
6" METAL STUD,
SEE PLANS AND WALL TAG
FOR STUD SIZE, TYP.
SOUND BATTS
1650 Fallridge Road, Suite C-1
Vail, Colorado 81657
f.(970) 476-4901 p.(970)476-6342
616 W LIONSHEAD
CIRCLE
VAIL,
COLORADO
81657
A2.2
WALL
ASSEMBLY
THE LITTLE
DINER
Project #: 1658
10/20/16
PERMIT SET
1 1/2" = 1'-0"
1
WALL ASSEMBLY W3-4 - 3 5/8" METAL
STUD INTERIOR PARTITION
1 1/2" = 1'-0"
2
WALL ASSEMBLY W3-6 - 6" METAL STUD
INTERIOR PARTITION
03/15/17