HomeMy WebLinkAboutB17-0049_EL00_1494619241.pdf1. THE ELECTRICAL CONTRACTOR SHALL INSTALL FIXTURES SPECIFIED BY 186 LIGHTING DESIGN GROUP, INC. (186). ANY SUBSTITUTIONS MUST BE APPROVED IN WRITING BY 186. UNAPPROVED SUBSTITUTIONS ARE SUBJECT TO REPLACEMENT WITH SPECIFIED FIXTURES AT THE ELECTRICAL CONTRACTOR'S COST. 2. UPON RECEIPT OF DESIGN DOCUMENT SET, THE ELECTRICAL CONTRACTOR IS TO VERIFY ALL FIXTURE LEAD TIMES WITH DISTRIBUTOR, AND GET APPROVAL FROM THE GENERAL CONTRACTOR THAT THESE LEAD TIMES ARE ACCEPTABLE. IF ANY FIXTURE LEAD TIMES ARE NOT APPROVED BY THE GENERAL CONTRACTOR, THE ELECTRICAL CONTRACTOR IS TO CONTACT 186 IMMEDIATELY FOR ASSISTANCE WITH DECREASING LEAD TIMES OR FOR ALTERNATE SPECIFICATION. ELECTRICAL CONTRACTOR IS TO FOLLOW THIS PROTOCOL THROUGHOUT PROJECT AS NEW DRAWINGS AND SPECIFICATION SETS ARE ISSUED. 3. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR ALL APPLIANCE OUTLETS, DISPOSALS, AND POWER FOR SYSTEMS NOT SHOWN ON 186 PLANS (IE. POWER FOR HVAC EQUIPMENT, POOL EQUIPMENT, ETC.) INTERIOR DESIGNER IS TO SUPPLY APPLIANCE PACKAGE FOR ELECTRICAL REQUIREMENTS. GENERAL CONTRACTOR IS TO SUPPLY ALL POWER REQUIREMENTS FOR SYSTEMS NOT SHOWN ON PLANS. AUDIO/VIDEO CONTRACTOR IS TO SUPPLY ALL POWER REQUIREMENTS FOR ALL A/V EQUIPMENT. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR MEETING ALL APPLICABLE CODES AND GFI REQUIREMENTS. 4. ELECTRICAL AND GENERAL CONTRACTORS ARE RESPONSIBLE FOR VERIFYING ALL FIXTURE COUNTS PRIOR TO ORDERING. 186 IS NOT RESPONSIBLE FOR ANY RESTOCKING CHARGES DUE TO MIS-ORDERING OR CHANGES BY OTHERS AFTER THE INITIAL ORDER. 5. ALL FIXTURES SHALL BE INSTALLED ACCORDING TO MANUFACTURER SPECIFICATIONS AND RECOMMENDATIONS. 6. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL IC, AIRTIGHT, AND NON-IC FIXTURE LOCATIONS PRIOR TO ORDERING FIXTURES. INSULATION TO BE HELD A MINIMUM OF 3" FROM ALL NON-IC FIXTURES. 7. ALL FIXTURE HOUSING SLEEVES AND COLLARS THAT HOLD FIXTURE TRIMS ARE TO BE COMPLETELY FLUSH WITH CEILING AT ELECTRICAL TRIM-OUT. TRIMLESS/FLANGELESS RECESSED LIGHTS ARE TO BE MOCKED UP BY THE ELECTRICAL CONTRACTOR PRIOR TO INSTALLATION. 8. ELECTRICAL CONTRACTOR IS TO NOTIFY 186 IF ANY FIXTURE LOCATIONS MUST MOVE MORE THAN SIX INCHES DUE TO FIELD CONDITIONS. 9. ALL SCONCE AND CLOCK OUTLET LOCATIONS SHOWN ON DRAWINGS ARE APPROXIMATE. EXACT LOCATIONS AND HEIGHTS OF WALL SCONCES AND CLOCK OUTLETS FOR PICTURE LIGHTS ARE TO BE VERIFIED WITH THE INTERIOR DESIGNER AND/OR OWNER. 10. ALL LED STRIP INSTALLATIONS ARE TO BE INDIVIDUALLY FED IN LENGTHS NO LONGER THAN THE MAXIMUM LENGTHS RECOMMENDED BY THE MANUFACTURER. ELECTRICAL AND GENERAL CONTRACTOR ARE TO WORK TOGETHER TO ENSURE THERE ARE NO VISIBLE WIRENUTS OR ELECTRICAL CONNECTIONS. 11. ALL FIXTURES SHALL BE SUPPLIED WITH SPECIFIED LAMPS. WHERE BEAMSPREADS ARE NOT SPECIFIED, SUPPLY WIDEST BEAMSPREAD AVAILABLE FOR PARTICULAR LAMP TYPE. 12. ALL WIRING IS SHOWN SYMBOLICALLY ON PLANS. ACTUAL REMOTE TRANSFORMER/DRIVER LOCATIONS AND HOMERUNS ARE TO BE DETERMINED BY ELECTRICAL CONTRACTOR AND GENERAL CONTRACTOR. ALL REMOTE TRANSFORMERS/DRIVERS SHALL BE TOROIDAL AND MOUNTED IN A LOCATION REMOVED FROM THE ROOM'S AIRSPACE SUCH AS AN ATTIC, CABINET, OR CRAWLSPACE, UNLESS OTHERWISE NOTED. 13. ALL SWITCHED OUTLETS SHOWN ON PLANS SHALL BE WIRED SUCH THAT THE OUTLET MAY BE SWITCHED AT ANY TIME IN THE FUTURE. VERIFY ACTUAL OUTLETS TO SWITCH WITH OWNER. ALL HALF-SWITCHED OUTLETS ARE TO HAVE SWITCHED SIDE AND HOT SIDE FED FROM SAME BREAKER. 14. EXHAUST FAN LOCATIONS ARE SHOWN SYMBOLICALLY ON THE PLANS. VERIFY EXACT EXHAUST FAN LOCATIONS WITH MECHANICAL CONTRACTOR. 15. MOTION SENSORS SHALL BE WALL-MOUNTED AT STANDARD SWITCH HEIGHT UNLESS OTHERWISE NOTED. 16. ALL LOADS TO BE LANDED ON CONTROL DEVICES IN ORDER DRAWN ON PLANS. 17. CENTER LINE OF TYPICAL SWITCH AND WALLBOX DIMMER BOXES TO BE AT 48" A.F.F. CENTER LINE OF TYPICAL CONTROL SYSTEM KEYPADS TO BE AT 54" A.F.F. (EXCEPT AT BEDROOM HEADBOARD LOCATIONS, ABOVE COUNTERS, AND OTHER NON-TYPICAL KEYPAD LOCATIONS) VERIFY WITH OWNER, ARCHITECT, AND INTERIOR DESIGNER. ELECTRICAL CONTRACTOR AND A/V CONTRACTOR TO VERIFY ALL KEYPADS BESIDE BEDS ARE INSTALLED CLEAR OF BED HEADBOARD. 18. ELECTRICAL CONTRACTOR TO VERIFY DIMMER AND CONTROL LOCATIONS. 19. ALL LOADS IN REMOTE DIMMING PANELS TO BE LANDED WHERE SHOWN ON PANEL SCHEDULE PROVIDED BY LIGHTING CONTROL SYSTEM CONTRACTOR. ELECTRICAL CONTRACTOR SHALL NOTIFY LIGHTING CONTROL SYSTEM CONTRACTOR OF ANY LOADS THAT HAVE BEEN MOVED FOR ANY REASON. 20. IN ORDER TO INSURE REMOTE ACCESS TO THE LIGHTING CONTROL SYSTEM PROCESSOR(S), A PHONE OUTLET OR ETHERNET CONNECTION, AS WELL AS AN ELECTRICAL OUTLET IS REQUIRED AT ALL PROCESSOR LOCATIONS. 21. ELECTRICAL CONTRACTOR AND A/V CONTRACTOR ARE TO VERIFY ALL FINISHES OF ELECTRICAL DEVICES, LIGHTING TRIMS, AND WALL-BOX DEVICES WITH THE INTERIOR DESIGNER AND/OR OWNERS PRIOR TO ORDERING. IF THESE COLORS OR FINISHES ARE NOT VERIFIED, ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR REPLACING EQUIPMENT AND DEVICES AT NO COST TO THE OWNERS. 22. ELECTRICAL CONTRACTOR TO PROVIDE (10) EXTRA OF 10 DEGREE SPOTS, 25 DEGREE NARROW FLOODS, 40 DEGREE FLOODS, AND 60 DEGREE WIDE FLOODS FOR AIMING AND SPARE STOCK FOR OWNER. PROVIDE FLOOD BEAMSPREADS FOR MR-16 LAMPS WHERE BEAMSPREAD IS NOT DESIGNATED ON 186 BEAMSPREAD DRAWINGS. ELECTRICAL CONTRACTOR TO REQUEST BEAMSPOREAD PLAN FROM 186 PRIOR TO PURCHASE AND ELECTRICAL TRIM OUT OF MR16 LAMPHOLDERS. 23. ALL ADJUSTABLE ACCENTS TO BE AIMED STRAIGHT DOWN AT ELECTRICAL TRIM-OUT. ELECTRICAL CONTRACTOR TO PROVIDE LADDERS AND PERSONNEL TO ASSIST 186 AND CLIENT WITH FINAL AIMING OF ADJUSTABLE FIXTURES WHEN ARTWORK AND FURNITURE ARE IN PLACE. AIMING SESSIONS ARE TYPICALLY AFTER SUNSET. 24. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR APPROPRIATE SIZING OF ALL ELECTRICAL CONDUCTORS. 12-VOLT SYSTEMS SUCH AS MONORAIL, CABLE, AND LOW VOLT TRACK SHALL BE FED WITH STRANDED WIRE OF AN APPROPRIATE GAUGE FOR LIGHTING LOAD SHOWN ON PLANS. WIRING SHALL BE SIZED SUCH THAT VOLTAGE DROP TO LOW VOLTAGE SYSTEMS IS NOT GREATER THAN 10%. IF NECESSARY, USE MULTI-TAP TRANSFORMER TO ACHIEVE REQUIRED VOLTAGE AT EACH LIGHT. ALL REFERENCES TO ELECTRICAL OR LOW VOLTAGE SYSTEMS THAT ARE NOT DIRECTLY RELATED TO LIGHTING ARE ON THE PLANS FOR REFERENCE ONLY. ACTUAL FINAL LOCATIONS AND DIMENSIONS ARE TO BE PROVIDED BY OTHERS. KEYPAD DATA OUTLET CABLE TELEVISION OUTLET THERMOSTAT TRANSFORMER SATELLITE TELEVISION OUTLET TELEPHONE QUAD OUTLET 220V OUTLET DOOR JAMB SWITCH HOT ELECTRICAL OUTLET MOTION SENSOR 1/2 SWITCHED FLOOR OUTLET HOT FLOOR OUTLET FULLY SWITCHED OUTLET 1/2 SWITCHED OUTLET WEATHERPROOF GFI OUTLET GFI PROTECTED OUTLET 3-WAY SWITCH 4-WAY SWITCH 3-WAY DIMMER FULLY SWITCHED FLOOR OUTLET DIMMER SWITCH LEGEND A/V TOUCHSCREEN LINE VOLTAGE CONTROL SYSTEM DIMMER SPEAKER S MS S S S S S 1/4 SWITCHED QUAD OUTLET GARAGE DOOR OUTLET RF TABLETOP KEYPAD RF LAMP DIMMER - PLUG INTO HOT OUTLET CIRCUIT NUMBER HOT QUAD FLOOR OUTLET 1/4 SWITCHED QUAD FLOOR OUTLET 1234 T-STAT GENERAL NOTES MR16 LEGEND 10 DEGREE SPOT BEAMSPREAD 25 DEGREE NARROW FLOOD BEAMSPREAD 40 DEGREE FLOOD BEAMSPREAD 60 DEGREE WIDE FLOOD BEAMSPREAD DIFFUSING LENS SOFT FOCUS LENS LINEAR SPREAD LENS FROSTED LENS CLEAR LENS HONEYCOMB LOUVER COLOR LEGEND SYSTEM DIMMER/HYBRID KEYPAD NON-SYSTEM DEVICES SYSTEM HOMERUN LOAD LOW VOLTAGE KEYPAD; FIREPLACE; MOTOR POWER OUTLETS FIBEROPTIC ILLUMINATOR SURFACE-MOUNTED LINEAR LIGHT LANDSCAPE ACCENT EXTERIOR PATH LIGHT UNDERWATER ACCENT WALL-RECESSED STEP LIGHT RECESSED LINEAR LIGHT IN-GROUND WELL LIGHT POST TOP LIGHT T RECESSED WALL WASH, ROUND OR SQUARE LOW VOLTAGE OR LED STRIP SHADE MOTOR / WINDOW MOTOR EXHAUST FAN CEILING FAN 12V OR 24V ROUGH-IN JUNCTION BOX MONOPOINT HEAD DUAL-HEADED MONOPOINT TRACK LIGHTING HANGING PENDANT OR CHANDELIER WALL MOUNTED FIXTURE RECESSED ADJUSTABLE ACCENT, ROUND OR SQUARE MINI-RECESSED DOWNLIGHT OR PUCKLIGHT RECESSED DOWNLIGHT, ROUND OR SQUARE CEILING MOUNTED FIXTURE W P C CLOCK OUTLET FOR PICTURE LIGHT CO 48" FO FP JB POOL LIGHT LONG HANGING PENDANT OR CHANDELIER, VERIFY FEED LOC. FIREPLACE IGNITION 1-HEADED RECESSED MULTIPLE 2-HEADED RECESSED MULTIPLE 3-HEADED RECESSED MULTIPLE P RECESSED LINEAR WALL WASH 12/24V JB JUNCTION BOX JB RGBW 5-CONDUCTOR LOW VOLTAGE ROUGH-IN JUNCTION BOX JB RGB 4-CONDUCTOR LOW VOLTAGE ROUGH-IN JUNCTION BOX WALL MOUNTED SWING-ARM LAMP OR MAKEUP MIRROR WITH INTEGRAL SWITCH XFMR SP NFL FL WFL DIFF SOFT LIN FROST CLR LOUV VERIFY IN FIELD VIF TABLE OF CONTENTS EL-0.0 STANDARD LEGENDS & NOTES EL-1.0 LOWER LEVEL LIGHTING PLAN EL-2.0 MAIN LEVEL LIGHTING PLAN LIPNICK RESIDENCE VAIL, COLORADO REVISION/ISSUE DATE PROGRESS SET 2017-02-23 PROGRESS SET 2017-03-03 PRICING SET 2017-03-13 SHEET NUMBER: 186 LIGHTING DESIGN GROUP,INC. 1200 BANNOCK ST. DENVER, CO 80204 TEL:303.534.5350 www.186group.com STANDARD LEGENDS & NOTES NO SCALE EL-0.0 05/12/17