Loading...
HomeMy WebLinkAboutB17-0053_A10.2_1493402427.pdfA4.2 1 A4.2 2 A4.1 1 A4.1 2 A4.4 1 A4.4 2 A4.3 1 1 A5.1 1 A5.3 2 A5.1 1 A5.2 A4.3 3 A4.3 2 A4.4 4 3 2 A5.2 2 A5.4 1 A5.4 2 A5.3 4 2" / 12" 2" / 12" 2" / 12" GARAGE 111 MUDROOM 110 LAUNDRY 107 CLOSET 109 POWDER 108 KITCHEN 104 SITTING ROOM 105 PANTRY 106 DINING ROOM 103 LIVING ROOM 102 ENTRY 101 ELEC. CLOSET 112 B.O. DECKING @ 9' - 4 1/2" A.F.F. B.O. CLG @ 9' - 9 3/8" A.F.F. B.O. CLG @ 9' - 9 3/8" A.F.F. B.O. CLG @ 9' - 9 3/8" A.F.F. B.O. CLG @ 9' - 0" A.F.F. D3 D3 DN TO LIGHT SWITCH 333 H H H H 3 3 3 3 G A 3 3 3 3 A3 A3 A3 A3 A A A A A A A A A A A A A 3 3 3 3 U 3 A A 33 3 U U U A3 A4 A4 A4 A4 A4 A4 TV ABOVE FIREPLACE U LED LIGHTS C C C C 2" / 12" J-BOX J-BOX STEP LIGHT B B B B B B B3 B3 B B B B B B B B 3 L TO STEP LIGHTS - ALL STEP LIGHTS ON ONE CIRCUIT 3 3 3 3 UP TO LIGHTS UP TO J-BOX G G DN TO CAN LIGHTS W10X22 W10X22 W10X22 W10X22 W10X22 W10X22 W10X22 1 2 3 4 5 6 7 G A B C D E F 1A 1B AA BB J-BOX J-BOX P P P 40' - 11" 6' - 6" 6' - 3" 8' - 10" 3' - 0" 12' - 5" 3' - 11" 27' - 5" 27' - 5" 7' - 4" 7' - 10" 5' - 8" 17' - 7" 10' - 8" 2' - 9" 51' - 10" M F HEATER HEATER HEATER HEATER 220 HOOD GAS GAS GAS M GFI GFI 220 TV TV RANGE GFI GFI GFI E E E W12X65 W10X22 Q Q TV LAUNDRY CHUTE IN CABINET Q 5' - 3 1/4" 4' - 10 1/2" 5' - 6" 8' - 11 1/8" 4' - 0 3/8" 3' - 7 3/4" 8' - 8 1/4" 1' - 6" 2' - 9 1/8" 2' - 0" 5' - 2" 2' - 7 1/2" 10' - 3" 9' - 7" 6' - 8" 4' - 8"11' - 10"10' - 0" 2' - 3 1/2" 2' - 3 1/2" 2' - 6 3/4" 2' - 6 3/4" EQ EQ 3' - 2" 3' - 2" 4' - 3 3/8" 5' - 1" 5' - 9 3/8" 4' - 0" 4' - 0" 1' - 10" 3' - 4 7/8" 3' - 4 7/8" 3' - 4 7/8" 4' - 9 3/4" 1' - 10" 4' - 5 1/2" 1' - 6" 2' - 8 3/4" 1' - 7" 6' - 4 3/4" 5' - 7 7/8" 4' - 0" 1' - 10" 4' - 3 3/4" 4' - 3 3/4" 4' - 3 3/4" B.O. CLG @ 9' - 0" A.F.F. W14X74 U JAMB SWITCH 1 A5.6 1 A5.5 2 A5.5 FAN 3' - 1 1/2" 3' - 8" 3' - 8" 2' - 1 5/8" 2' - 2" 6' - 0 1/8" 6' - 0 1/8" A A A A A A A A MECH. CHASE B.O. CLG @ 8' - 10" A.F.F. 4' - 3" 3' - 11 5/8" 3' - 11 5/8" 3' - 11 5/8" 5 1/2" 6' - 11" 220V FOR CAR CHARGER EXTERIOR LIGHTING- 1 LIGHT PER 1,000 SF OF LOT AREA, THEREFORE 15 LIGHTS ARE ALLOWED. 15 EXTERIOR LIGHTS 18"+ ABOVE GRADE ARE PROPOSED. SEE ELEVATIONS AND PLANS FOR TYPE, LOCATION AND NUMBER OF FIXTURES: A3- FLAT CEILING EXTERIOR RECESSED CAN HALO 4" 50W PAR20- (7) TOTAL FIXTURES E- HUBBARDTON FORGE AIRIS MEDIUM EXTERIOR SCONCE BRONZE FINISH - (6) TOTAL FIXTURES M- HEVI LITE INC HL-374 PAR-20 SURFACE MOUNT DOWN LIGHT BRONZE POWDER COAT FINISH (BZ)- (2) TOTAL FIXTURE L- (4) BOLLARD LANDSCAPE LIGHT LESS THAN 18" TALL PROPOSED GENERAL NOTES: 1. PRIOR TO PULLING ANY WIRE, SCHEDULE A WALK THROUGH W/ ARCHITECT & OWNER FOR ELECTRICAL BOX, SWITCH BOX, J-BOX, SCONCE & CAN LIGHT ROUGH IN, ETC. 2. LOCATE SWITCHES AS CLOSE TO TRIM/END OF WALL AS POSSIBLE, SWITCHES MAY BE SHOWN FARTHER FROM END OF WALL/TRIM FOR CLARITY. 3. LOCATION OF OUTLETS AND OTHER ELECTRICAL DEVICES IS DIAGRAMMATIC -- ACTUAL PLACEMENT OF ELEMENTS, WORK, MATERIALS AND EQUIPMENT SHALL CONFORM TO THE LATEST EDITIONS OF LOCAL, STATE OF COLORADO, AND NATIONAL CODES AND ORDINANCES. 4. OUTLETS TO BE LOCATED VERTICALLY W/ CENTERLINE @ 16" ABOVE FINISHED FLOOR, AND SWITCHES 42" TO CENTERLINE ABOVE FINISHED FLOOR, UNLESS OTHERWISE SPECIFIED. AT LOCATIONS WHERE THIS IS NOT POSSIBLE, CONSULT THE ARCHITECT. 5. PROVIDE SMOKE DETECTORS AS REQUIRED. SMOKE DETECTORS WILL BE CONNECTED TO THE MONITORED FIRE ALARM SYSTEM. 6. PROVIDE GFI OUTLET IN EVERY VANITY @ ONE SINK IN CABINET, EXCEPT FOR POWDER ROOMS. 7. ALL DIMENSIONS TO CENTER LINE OF FIXTURE. COORDINATE FIXTURE LOCATION WITH STRUCTURE AND TO ALIGN AND CENTER FIXTURES AS CLOSE AS POSSIBLE PROVIDE GFI OUTLET IN EVERY VANITY @ ONE SINK IN CABINET, EXCEPT FOR POWDER ROOMS. 8. COORDINATE SWITCHED OUTLETS LOCATIONS AT VANITY WALLS AND FLOORS WITH FURNITURE PLANS, INTERIOR DOCUMENTS & OWNER 9. PROVIDE CARBON MONOXIDE DETECTORS THROUGHOUT THE HOUSE PER R315. CARBON MONOXIDE DETECTORS WILL BE CONNECTED TO THE MONITORED FIRE ALARM SYSTEM. 10. OUTLETS ABOVE VANITIES TO BE VERTICAL WITH CENTERLINE AT 46" AFF EXCEPT AS NOTED. VERIFY LOCATION & HEIGHT WITH OWNER. 11. VERIFY ALL APPLIANCE ELECTRICAL LOADS WITH OWNER SPECS. 12. PROVIDE POWER AS REQUIRED PER MECHANICAL CONTRACTOR AND SPEC. 13. VERIFY CANS FIT IN STRUCTURAL CAVITY/ JOIST SPACING BEFORE ORDERING. 14. PROVIDE J-BOX FOR HEAT TAPE LOW ON WALL @ ALL DOWNSPOUT LOCATIONS - COORDINATE W/ ROOFER FOR DOWNSPOUT & EXCAVATOR FOR UNDERGROUND PIPING FOR DOWNSPOUTS. PROVIDE SUFFICIENT AMPERAGE CAPACITY TO PROVIDE CONTINUOUS HEAT TAPE @ DOWN SPOUTS & GUTTER AS WELL AS FOR FUTURE 3' HIGH ZIG ZAG @ B.O. ROOF ABOVE GUTTERS IF REQ'D IN FUTURE. 15. CENTER ALL LIGHTS BETWEEN EXPOSED ROOF JOISTS/ BEAM U.N.O. US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Scale Date Drawn by Checked by Issue Date 3/23/2017 1:12:49 PM 1/4" = 1'-0" LILES RESIDENCE 2440 CHAMONIX LANE VAIL, CO 81657 A10.2 MAIN LEVEL RCP 3-23-2017 CPM HB 3-23-2017 PERMIT SET 1/4" = 1'-0" 1 MAIN LEVEL REFLECTED CEILING PLAN 0' 2' 4' 8' 16' NORTH REVISION SCHEDULE # DESCRIPTION DATE 04/28/17