GARAGE
111
MUDROOM
110
LAUNDRY
107
CLOSET
109
POWDER
108
KITCHEN
104
SITTING ROOM
105
PANTRY
106
DINING ROOM
103
LIVING ROOM
102
ENTRY
101
ELEC.
CLOSET
112
B.O. DECKING @ 9' - 4 1/2" A.F.F.
B.O. CLG @ 9' - 9 3/8" A.F.F.
B.O. CLG @ 9' - 9 3/8" A.F.F.
B.O. CLG @ 9' - 9 3/8" A.F.F.
B.O. CLG @ 9' - 0" A.F.F.
D3 D3 DN TO LIGHT SWITCH
333
H
H
H
H
3
3 3
3
G
A
3
3
3 3
A3
A3
A3
A3
A
A
A
A
A A
A
A A
A
A
A A 3 3
3
3 U 3
A
A
33 3
U U
U
A3 A4 A4
A4 A4
A4 A4
TV ABOVE
FIREPLACE
U
LED LIGHTS
C
C
C
C
2" / 12"
J-BOX
J-BOX
STEP LIGHT
B
B
B
B
B
B
B3
B3
B B B
B B B
B B 3
L
TO STEP LIGHTS - ALL STEP
LIGHTS ON ONE CIRCUIT
3 3 3 3
UP TO LIGHTS
UP TO J-BOX
G
G
DN TO CAN LIGHTS
W10X22
W10X22
W10X22
W10X22
W10X22
W10X22
W10X22
1 2 3 4 5 6 7
G
A
B
C
D
E
F
1A
1B
AA
BB
J-BOX
J-BOX
P P P
40' - 11"
6' - 6" 6' - 3" 8' - 10" 3' - 0" 12' - 5" 3' - 11"
27' - 5"
27' - 5"
7' - 4"
7' - 10"
5' - 8" 17' - 7" 10' - 8" 2' - 9"
51' - 10"
M
F
HEATER
HEATER
HEATER
HEATER
220
HOOD
GAS GAS
GAS
M GFI
GFI
220
TV
TV RANGE
GFI
GFI
GFI
E
E
E
W12X65
W10X22
Q
Q
TV
LAUNDRY
CHUTE IN
CABINET
Q
5' - 3 1/4" 4' - 10 1/2"
5' - 6"
8' - 11 1/8" 4' - 0 3/8" 3' - 7 3/4" 8' - 8 1/4"
1' - 6"
2' - 9 1/8"
2' - 0"
5' - 2" 2' - 7 1/2"
10' - 3"
9' - 7"
6' - 8"
4' - 8"11' - 10"10' - 0"
2' - 3 1/2"
2' - 3 1/2" 2' - 6 3/4"
2' - 6 3/4"
EQ
EQ 3' - 2" 3' - 2"
4' - 3 3/8"
5' - 1"
5' - 9 3/8" 4' - 0" 4' - 0" 1' - 10"
3' - 4 7/8"
3' - 4 7/8"
3' - 4 7/8"
4' - 9 3/4"
1' - 10"
4' - 5 1/2"
1' - 6"
2' - 8 3/4"
1' - 7"
6' - 4 3/4"
5' - 7 7/8"
4' - 0"
1' - 10"
4' - 3 3/4"
4' - 3 3/4"
4' - 3 3/4"
B.O. CLG @ 9' - 0" A.F.F.
W14X74
U
JAMB SWITCH
1
A5.6
1
A5.5
2
A5.5
FAN
3' - 1 1/2"
3' - 8"
3' - 8"
2' - 1 5/8"
2' - 2" 6' - 0 1/8" 6' - 0 1/8"
A
A
A
A A
A A
A
MECH. CHASE
B.O. CLG @ 8' - 10" A.F.F.
4' - 3" 3' - 11 5/8" 3' - 11 5/8" 3' - 11 5/8"
5 1/2" 6' - 11"
220V FOR CAR CHARGER
EXTERIOR LIGHTING-
1 LIGHT PER 1,000 SF OF LOT AREA, THEREFORE 15 LIGHTS ARE
ALLOWED. 15 EXTERIOR LIGHTS 18"+ ABOVE GRADE ARE
PROPOSED. SEE ELEVATIONS AND PLANS FOR TYPE, LOCATION
AND NUMBER OF FIXTURES:
A3- FLAT CEILING EXTERIOR RECESSED CAN HALO 4" 50W PAR20-
(7) TOTAL FIXTURES
E- HUBBARDTON FORGE AIRIS MEDIUM EXTERIOR SCONCE
BRONZE FINISH - (6) TOTAL FIXTURES
M- HEVI LITE INC HL-374 PAR-20 SURFACE MOUNT DOWN LIGHT
BRONZE POWDER COAT FINISH (BZ)- (2) TOTAL FIXTURE
L- (4) BOLLARD LANDSCAPE LIGHT LESS THAN 18" TALL PROPOSED
GENERAL NOTES:
1. PRIOR TO PULLING ANY WIRE, SCHEDULE A WALK THROUGH W/ ARCHITECT & OWNER FOR
ELECTRICAL BOX, SWITCH BOX, J-BOX, SCONCE & CAN LIGHT ROUGH IN, ETC.
2. LOCATE SWITCHES AS CLOSE TO TRIM/END OF WALL AS POSSIBLE, SWITCHES MAY BE SHOWN
FARTHER FROM END OF WALL/TRIM FOR CLARITY.
3. LOCATION OF OUTLETS AND OTHER ELECTRICAL DEVICES IS DIAGRAMMATIC -- ACTUAL
PLACEMENT OF ELEMENTS, WORK, MATERIALS AND EQUIPMENT SHALL CONFORM TO THE
LATEST EDITIONS OF LOCAL, STATE OF COLORADO, AND NATIONAL CODES AND ORDINANCES.
4. OUTLETS TO BE LOCATED VERTICALLY W/ CENTERLINE @ 16" ABOVE FINISHED FLOOR, AND
SWITCHES 42" TO CENTERLINE ABOVE FINISHED FLOOR, UNLESS OTHERWISE SPECIFIED. AT
LOCATIONS WHERE THIS IS NOT POSSIBLE, CONSULT THE ARCHITECT.
5. PROVIDE SMOKE DETECTORS AS REQUIRED. SMOKE DETECTORS WILL BE CONNECTED TO THE
MONITORED FIRE ALARM SYSTEM.
6. PROVIDE GFI OUTLET IN EVERY VANITY @ ONE SINK IN CABINET, EXCEPT FOR POWDER ROOMS.
7. ALL DIMENSIONS TO CENTER LINE OF FIXTURE. COORDINATE FIXTURE LOCATION WITH
STRUCTURE AND TO ALIGN AND CENTER FIXTURES AS CLOSE AS POSSIBLE PROVIDE GFI
OUTLET IN EVERY VANITY @ ONE SINK IN CABINET, EXCEPT FOR POWDER ROOMS.
8. COORDINATE SWITCHED OUTLETS LOCATIONS AT VANITY WALLS AND FLOORS WITH FURNITURE
PLANS, INTERIOR DOCUMENTS & OWNER
9. PROVIDE CARBON MONOXIDE DETECTORS THROUGHOUT THE HOUSE PER R315. CARBON
MONOXIDE DETECTORS WILL BE CONNECTED TO THE MONITORED FIRE ALARM SYSTEM.
10. OUTLETS ABOVE VANITIES TO BE VERTICAL WITH CENTERLINE AT 46" AFF EXCEPT AS NOTED.
VERIFY LOCATION & HEIGHT WITH OWNER.
11. VERIFY ALL APPLIANCE ELECTRICAL LOADS WITH OWNER SPECS.
12. PROVIDE POWER AS REQUIRED PER MECHANICAL CONTRACTOR AND SPEC.
13. VERIFY CANS FIT IN STRUCTURAL CAVITY/ JOIST SPACING BEFORE ORDERING.
14. PROVIDE J-BOX FOR HEAT TAPE LOW ON WALL @ ALL DOWNSPOUT LOCATIONS - COORDINATE
W/ ROOFER FOR DOWNSPOUT & EXCAVATOR FOR UNDERGROUND PIPING FOR DOWNSPOUTS.
PROVIDE SUFFICIENT AMPERAGE CAPACITY TO PROVIDE CONTINUOUS HEAT TAPE @ DOWN
SPOUTS & GUTTER AS WELL AS FOR FUTURE 3' HIGH ZIG ZAG @ B.O. ROOF ABOVE GUTTERS IF
REQ'D IN FUTURE.
15. CENTER ALL LIGHTS BETWEEN EXPOSED ROOF JOISTS/ BEAM U.N.O.
US Mail Only: P. O. Box 2378
Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Scale
Date
Drawn by
Checked by
Issue Date 3/23/2017 1:12:49 PM
1/4" = 1'-0"
LILES RESIDENCE
2440 CHAMONIX LANE
VAIL, CO 81657
A10.2
MAIN
LEVEL RCP
3-23-2017
CPM
HB
3-23-2017
PERMIT SET
1/4" = 1'-0"
1 MAIN LEVEL REFLECTED CEILING PLAN
0' 2' 4' 8' 16'
NORTH
REVISION SCHEDULE
# DESCRIPTION DATE
04/28/17