Loading...
HomeMy WebLinkAboutB17-0053_A6.1_1493402453.pdfSLOPE RE: PLANS INTERIOR GRID LINE T.O. SLAB RE: FLOOR PLANS 1/2" 2" 8" RE: STRUCT BASE BOARD TYPICAL. SEE INTERIOR FINISH SCHEDULE SEALANT JOINT B/W EDGE OF SLAB & WALL TO PREVENT RADON GAS INFILTRATION RE: RADON GAS MITIGATION NOTES P.T. BOTTOM PLATE, TYP. IN CONTACT W/ CONC. EXTERIOR RE: STRUCT RE: STRUCT 3D DRAINAGE MEDIUM CONTINUOUS (WRAPS STL. ANGLE) @ STL. ANGLE TO ALLOW STONE VENEER TO DRAIN. TIES INTO FOUNDATION DRAINAGE MEDIUM WHICH IS CONTINUOUS FROM T.O. CONC. WALL TO B.O. FOOTING T.O. CONC. WALL RE: STRUCT 2" 2# CLOSED CELL SPRAY FOAM INSULATION BETWEEN 2X FURRING LINE OF 2X P.T. FURRING HELD 1" OFF OF CONC. FOUNDATION WALL. SHIM AND SECURE TO CONC. WALL AS REQ'D PROVIDE 2" RIGID INSULATION HELD DOWN 1/2" @ EDGE OF SLAB W/ BEVEL CUT AS SHOWN FOUNDATION WATERPROOF MEMBRANE CONT. FROM B.O. WALL TO T.O. CONC. RE: SPEC 15 MIL VAPOR/RADON BARRIER TURN UP WALL SEAL AND MECH FASTEN TO CONC WALL. LAP & SEAL ALL JOINTS, SEAL ALL PENETRATIONS. RE: COVER SHEET RADON NOTES & SPEC. TYPICAL FOUNDATION NOTES: CONCRETE FOUNDATION RE: STRUCT. REQUIREMENTS 4" MIN. DRAIN GRAVEL BASE RE: SOILS ENGINEER RECOMMENDATION/STRUCT. LAP B.O. 36" BITUTHANE SHEET MIN. 6" OVER FOUNDATION WATERPROOFING & EXTEND UP WOOD WALL APPROX. 30". USE BONDING AGENTS AS REQ'D RE: SPEC. 3/4" FINISH FLOOR RE: FLOOR PLANS, INTERIOR FINISH SCHEDULE, AND SPEC 3D DRAINAGE MEDIUM W/ FILTER FABRIC CONTINUOUS @ WALL RE: SPEC AIR AND WATER INFILTRATION BARRIER RE: SPEC CONCRETE FOUNDATION WALL RE: STRUCT. 6" MIN. 6" MIN 4" DIA. RIGID PERFORATED PIPE SURROUNDED BY FILTER FABRIC AND GRAVEL SLOPED 1% MIN. TO DAYLIGHT PER SOILS REPORT. RE SOILS REPORT FOR ADDITIONAL FOUNDATION & PERIMETER DRAIN REQUIREMENTS & SPEC R-10 RIGID FOAM INSULATION PANEL RE: SPEC & COVER SHEET CONC. SLAB ON GRADE W/ IN-FLOOR RADIANT HEAT RE: STRUCT. STONE VENEER WALL ASSEMBLY PER 4/A6.7 STEEL ANGLE SHOP PAINTED W/ PROTECTIVE PAINT FINISH, THEN COAT W/ ASPHALTIC DAMP PROOFING RE: STRUCT. RE: SPEC P.T. BOTTOM PLATE 1" SLOPE GRADE @ 10% MIN. SLOPE FOR 10' PER SITE PLAN & SOILS REPORT FILL ENTIRE CAVITY W/ INSULATION 2X4 WALL OR FURRING AS REQ'D 3 1/2" SMART MEMBRANE VAPOR BARRIER TYP. RE: SPEC. FOUNDATION INSULATION & DRAINAGE MEDIUM RE: SPEC 2" R-10 RIGID FOAM INSULATION PANEL FROM T.O. ANGLE TO T.O. CONC. WALL USE 4" STONE @ INSULATION PANEL 5/8" GWB 2 PIECE ADJUSTABLE VENEER TIE ANCHORED TO CONC. WALL @ FOAM CONDITION RE: SPEC. 2 1/2" NON TACKY/ NON STICKY W.P. MEMBRANE OVER TOP OF FOOTING TO CREATE MOISTURE BREAK TYPICAL @ ALL FOOTINGS RE: SPEC FOAM SILL GASKET BETWEEN BOTTOM PLATE & T.O. CONC. WALL P.T. BOTTOM PLATE SLOPE RE: PLANS RE: STRUCT. RE: STRUCT. RE: STRUCT. 5" INTERIOR EXTERIOR GRID LINE T.O. SLAB RE: FLOOR PLANS 6" MIN. 6" MIN. SEE DETAIL 1/A6.1 FOR TYP. FOUNDATION NOTES STONE VENEER WALL ASSEMBLY PER 4/A6.7 RE: STRUCT RE: STRUCT. T.O. LEDGE @ 80' - 11" US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Scale Date Drawn by Checked by Issue Date 3/23/2017 1:07:02 PM 3" = 1'-0" LILES RESIDENCE 2440 CHAMONIX LANE VAIL, CO 81657 A6.1 FOUNDATION DETAILS 3-23-2017 CPM HB 3-23-2017 PERMIT SET 3" = 1'-0" 1 FOUNDATION DETAIL @ GRADE ABOVE FINISHED FLOOR 3" = 1'-0" 2 FOUNDATION DETAIL @ GRADE REVISION SCHEDULE # DESCRIPTION DATE 04/28/17