HomeMy WebLinkAboutB17-0053_A6.1_1493402453.pdfSLOPE RE: PLANS
INTERIOR
GRID
LINE
T.O. SLAB
RE: FLOOR PLANS
1/2" 2" 8" RE: STRUCT
BASE BOARD TYPICAL. SEE
INTERIOR FINISH SCHEDULE
SEALANT JOINT B/W EDGE OF SLAB & WALL
TO PREVENT RADON GAS INFILTRATION
RE: RADON GAS MITIGATION NOTES
P.T. BOTTOM PLATE, TYP. IN CONTACT W/ CONC.
EXTERIOR
RE: STRUCT
RE: STRUCT
3D DRAINAGE MEDIUM CONTINUOUS (WRAPS
STL. ANGLE) @ STL. ANGLE TO ALLOW STONE
VENEER TO DRAIN. TIES INTO FOUNDATION
DRAINAGE MEDIUM WHICH IS CONTINUOUS
FROM T.O. CONC. WALL TO B.O. FOOTING
T.O. CONC. WALL
RE: STRUCT
2" 2# CLOSED CELL SPRAY FOAM
INSULATION BETWEEN 2X FURRING
LINE OF 2X P.T. FURRING HELD 1" OFF
OF CONC. FOUNDATION WALL. SHIM
AND SECURE TO CONC. WALL AS REQ'D
PROVIDE 2" RIGID INSULATION HELD DOWN 1/2"
@ EDGE OF SLAB W/ BEVEL CUT AS SHOWN
FOUNDATION WATERPROOF MEMBRANE
CONT. FROM B.O. WALL TO T.O. CONC.
RE: SPEC
15 MIL VAPOR/RADON BARRIER TURN UP WALL
SEAL AND MECH FASTEN TO CONC WALL. LAP
& SEAL ALL JOINTS, SEAL ALL PENETRATIONS.
RE: COVER SHEET RADON NOTES & SPEC.
TYPICAL FOUNDATION NOTES:
CONCRETE FOUNDATION
RE: STRUCT. REQUIREMENTS
4" MIN. DRAIN GRAVEL BASE RE: SOILS
ENGINEER RECOMMENDATION/STRUCT.
LAP B.O. 36" BITUTHANE SHEET MIN. 6"
OVER FOUNDATION WATERPROOFING &
EXTEND UP WOOD WALL APPROX. 30". USE
BONDING AGENTS AS REQ'D RE: SPEC.
3/4" FINISH FLOOR RE: FLOOR PLANS,
INTERIOR FINISH SCHEDULE, AND SPEC
3D DRAINAGE MEDIUM W/ FILTER FABRIC
CONTINUOUS @ WALL RE: SPEC
AIR AND WATER INFILTRATION
BARRIER RE: SPEC
CONCRETE FOUNDATION WALL RE: STRUCT.
6" MIN.
6" MIN
4" DIA. RIGID PERFORATED PIPE SURROUNDED
BY FILTER FABRIC AND GRAVEL SLOPED 1%
MIN. TO DAYLIGHT PER SOILS REPORT. RE
SOILS REPORT FOR ADDITIONAL FOUNDATION
& PERIMETER DRAIN REQUIREMENTS & SPEC
R-10 RIGID FOAM INSULATION PANEL
RE: SPEC & COVER SHEET
CONC. SLAB ON GRADE W/ IN-FLOOR
RADIANT HEAT RE: STRUCT.
STONE VENEER WALL ASSEMBLY PER 4/A6.7
STEEL ANGLE SHOP PAINTED W/
PROTECTIVE PAINT FINISH, THEN COAT W/
ASPHALTIC DAMP PROOFING RE: STRUCT.
RE: SPEC
P.T. BOTTOM PLATE
1"
SLOPE GRADE @ 10% MIN. SLOPE FOR 10'
PER SITE PLAN & SOILS REPORT
FILL ENTIRE CAVITY W/ INSULATION
2X4 WALL OR FURRING AS REQ'D
3 1/2"
SMART MEMBRANE VAPOR
BARRIER TYP. RE: SPEC.
FOUNDATION INSULATION & DRAINAGE
MEDIUM RE: SPEC
2" R-10 RIGID FOAM INSULATION PANEL
FROM T.O. ANGLE TO T.O. CONC. WALL
USE 4" STONE @ INSULATION PANEL
5/8" GWB
2 PIECE ADJUSTABLE VENEER TIE ANCHORED
TO CONC. WALL @ FOAM CONDITION RE: SPEC.
2 1/2"
NON TACKY/ NON STICKY W.P. MEMBRANE
OVER TOP OF FOOTING TO CREATE
MOISTURE BREAK TYPICAL @ ALL FOOTINGS
RE: SPEC
FOAM SILL GASKET BETWEEN BOTTOM
PLATE & T.O. CONC. WALL
P.T. BOTTOM PLATE
SLOPE RE: PLANS
RE: STRUCT.
RE:
STRUCT.
RE: STRUCT.
5"
INTERIOR EXTERIOR
GRID
LINE
T.O. SLAB
RE: FLOOR PLANS 6" MIN.
6" MIN.
SEE DETAIL 1/A6.1 FOR
TYP. FOUNDATION NOTES
STONE VENEER WALL
ASSEMBLY PER 4/A6.7
RE: STRUCT
RE: STRUCT.
T.O. LEDGE @ 80' - 11"
US Mail Only: P. O. Box 2378
Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Scale
Date
Drawn by
Checked by
Issue Date 3/23/2017 1:07:02 PM
3" = 1'-0"
LILES RESIDENCE
2440 CHAMONIX LANE
VAIL, CO 81657
A6.1
FOUNDATION
DETAILS
3-23-2017
CPM
HB
3-23-2017
PERMIT SET
3" = 1'-0"
1
FOUNDATION DETAIL @ GRADE ABOVE
FINISHED FLOOR
3" = 1'-0"
2 FOUNDATION DETAIL @ GRADE
REVISION SCHEDULE
# DESCRIPTION DATE
04/28/17