HomeMy WebLinkAboutB17-0053_A6.10_1493402455.pdf24" WIDE VALLEY FLASHING WITH SPLASH DIVERTER
STANDING SEAM METAL ROOF RE: SPEC
EXTEND 2ND LAYER OF W.P.
MEMBRANE 3' MIN. UP BOTH SIDES OF
VALLEY UNDER METAL FLASHING
ROOF SHEATHING RE: STRUCT.
I-JOIST RAFTERS RE: STRUCT.
FINISHED CEILING RE: RCP
1' - 2"
UPPER ROOF UNDERLAYMENT LAP
OVER VALLEY FLASHING MIN. 4"
12
2 8" MIN.
PROVIDE TWO ROWS OF HEAT TAPE ON
EACH SIDE OF ALL ROOF VALLEYS EACH
SIDE TO BE SEPARATE WIRE SO IF ONE
FAILS THE OTHER STILL WORKS
SEE 1/A6.9 FOR TYP. ROOF NOTES
SLOPE
PER ROOF PLAN
INTERIOR
EXTERIOR
HIGH TEMP ICE AND WATER SHIELD
CONT. UP WALL 36" MIN. RE: SPEC.
HEADER RE: STRUCT.
5 1/2"
WALL ASSEMBLY PER 2/A6.7
1"
TURN DOWN DRYWALL AND PAINT
TO MATCH DRYWALL CEILING
3D DRAINAGE MATERIAL CONT. BEHIND SIDING
TO AIR VENT @ TOP AND BOTTOM OF WALL
PFSM FLASHING EXTENDS UP BEHIND AIR
& WATER INFILTRATION BARRIER AND
EXTENDS OUT OVER ROOF
PROVIDE GAP BETWEEN SIDING & FLASHING
TO ALLOW VENTILATION & DRAINAGE
LAP WATERPROOF MEMBRANE OVER FLASHING
STL. BEAM RE: STRUCT.
12
2
STANDING STEAM METAL ROOF RE: SPEC
SEE 1/A6.9 FOR TYP. ROOF NOTES
CRICKET RE: ROOF PLAN
INTERIOR
EXTERIOR
WALL ASSEMBLY PER 2/A6.7
SLOPED STL. BEAM RE: STRUCT.
8"
STANDING STEAM METAL ROOF RE: SPEC
HIGH TEMP ICE AND WATER SHIELD
CONT. UP WALL 36" MIN. RE: SPEC.
3D DRAINAGE MATERIAL CONT. BEHIND SIDING
TO AIR VENT @ TOP AND BOTTOM OF WALL
PFSM FLASHING EXTENDS UP BEHIND AIR
& WATER INFILTRATION BARRIER AND
EXTENDS OUT OVER ROOF
PROVIDE GAP BETWEEN SIDING & FLASHING
TO ALLOW VENTILATION & DRAINAGE
LAP WATERPROOF MEMBRANE OVER FLASHING
SEE 4/A6.9 FOR TYP. ROOF NOTES
1 1/2" 1" 5 1/2"
FILL ENTIRE CAVITY W/ INSULATION
FURRING AS REQ'D
INTERIOR
EXTERIOR
SLOPED RIM RE: STRUCT.
PRE-FABRICATED METAL RIDGE CAP
STANDING SEAM METAL ROOFING RE: SPEC.
ROOF SHEATHING RE: STRUCT.
I-JOIST RAFTERS RE: STRUCT.
CONT. BEVEL PLATE RE:
STRUCT.
INSULATION RE: SPEC
(2) 14" LVL RE: STRUCT.
HIGH TEMPERATURE ICE AND WATER
SHIELD CONT. OVER RIDGE
SLOPE
PER ROOF PLAN
SLOPE
PER ROOF PLAN
1' - 2"
1' - 2"
STL. BEAM RE: STRUCT.
1' - 2"
12
2
STANDING SEAM METAL ROOFING RE: SPEC.
ROOF SHEATHING RE: STRUCT.
LVL JOISTS RE: STRUCT.
INSULATION RE: SPEC
HIGH TEMPERATURE ICE AND WATER
SHIELD CONT. OVER RIDGE
JOIST HANGERS RE: STRUCT. 1 3/4"
8X8 DOUG-FIR STRUT RE: STRUCT
STEEL I-BEAM RE: STRUCT.
LAG-BOLTED THRU BEAM FLANGE
FROM BELOW RE: STRUCT.
SEE 1/A6.9 FOR TYP. ROOF EAVE NOTES
5/8" PLYWOOD OVER SLEEPERS TO
CREATE WIRE CHASE FOR EXTERIOR
LIGHT FIXTURES RE: RCP
PAINT ALL EXPOSED THROUGH BOLTS
RE:STRUCT.
3" HSS COLUMN WELDED TO B.O.
BEAM & 6" X 6" X 1/2" STEEL BASE
PLATE WELDED TO KNIFE PLATE RE:
STRUCT. & SPEC
SLOPE
PER ROOF PLAN
RE: ROOF PLAN
BIRDS MOUTH CUT RATERS TO
ACCEPT ANGLE OF STEEL I-BEAM
US Mail Only: P. O. Box 2378
Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Scale
Date
Drawn by
Checked by
Issue Date 3/23/2017 1:08:44 PM
1 1/2" = 1'-0"
LILES RESIDENCE
2440 CHAMONIX LANE
VAIL, CO 81657
A6.10
ROOF
DETAILS
3-23-2017
CPM
HB
3-23-2017
PERMIT SET
1 1/2" = 1'-0"
1
VALLEY DETAIL @ STANDING SEAM
ROOF CRICKET
1 1/2" = 1'-0"
2
STL. BEAM DETAIL @ ROOF & WALL
CONNECTION
1 1/2" = 1'-0"
3
SLOPED STL. BEAM DETAIL @ ROOF &
WALL CONNECTION
1 1/2" = 1'-0"
4
ROOF DETAIL @ STANDING SEAM
METAL ROOF RIDGE
1 1/2" = 1'-0"
5 ROOF DETAIL @ STL. BEAM
1 1/2" = 1'-0"
6
UPPER ROOF EAVE DETAIL @ FRONT
ENTRY
REVISION SCHEDULE
# DESCRIPTION DATE
04/28/17