Loading...
HomeMy WebLinkAboutB17-0053_A6.10_1493402455.pdf24" WIDE VALLEY FLASHING WITH SPLASH DIVERTER STANDING SEAM METAL ROOF RE: SPEC EXTEND 2ND LAYER OF W.P. MEMBRANE 3' MIN. UP BOTH SIDES OF VALLEY UNDER METAL FLASHING ROOF SHEATHING RE: STRUCT. I-JOIST RAFTERS RE: STRUCT. FINISHED CEILING RE: RCP 1' - 2" UPPER ROOF UNDERLAYMENT LAP OVER VALLEY FLASHING MIN. 4" 12 2 8" MIN. PROVIDE TWO ROWS OF HEAT TAPE ON EACH SIDE OF ALL ROOF VALLEYS EACH SIDE TO BE SEPARATE WIRE SO IF ONE FAILS THE OTHER STILL WORKS SEE 1/A6.9 FOR TYP. ROOF NOTES SLOPE PER ROOF PLAN INTERIOR EXTERIOR HIGH TEMP ICE AND WATER SHIELD CONT. UP WALL 36" MIN. RE: SPEC. HEADER RE: STRUCT. 5 1/2" WALL ASSEMBLY PER 2/A6.7 1" TURN DOWN DRYWALL AND PAINT TO MATCH DRYWALL CEILING 3D DRAINAGE MATERIAL CONT. BEHIND SIDING TO AIR VENT @ TOP AND BOTTOM OF WALL PFSM FLASHING EXTENDS UP BEHIND AIR & WATER INFILTRATION BARRIER AND EXTENDS OUT OVER ROOF PROVIDE GAP BETWEEN SIDING & FLASHING TO ALLOW VENTILATION & DRAINAGE LAP WATERPROOF MEMBRANE OVER FLASHING STL. BEAM RE: STRUCT. 12 2 STANDING STEAM METAL ROOF RE: SPEC SEE 1/A6.9 FOR TYP. ROOF NOTES CRICKET RE: ROOF PLAN INTERIOR EXTERIOR WALL ASSEMBLY PER 2/A6.7 SLOPED STL. BEAM RE: STRUCT. 8" STANDING STEAM METAL ROOF RE: SPEC HIGH TEMP ICE AND WATER SHIELD CONT. UP WALL 36" MIN. RE: SPEC. 3D DRAINAGE MATERIAL CONT. BEHIND SIDING TO AIR VENT @ TOP AND BOTTOM OF WALL PFSM FLASHING EXTENDS UP BEHIND AIR & WATER INFILTRATION BARRIER AND EXTENDS OUT OVER ROOF PROVIDE GAP BETWEEN SIDING & FLASHING TO ALLOW VENTILATION & DRAINAGE LAP WATERPROOF MEMBRANE OVER FLASHING SEE 4/A6.9 FOR TYP. ROOF NOTES 1 1/2" 1" 5 1/2" FILL ENTIRE CAVITY W/ INSULATION FURRING AS REQ'D INTERIOR EXTERIOR SLOPED RIM RE: STRUCT. PRE-FABRICATED METAL RIDGE CAP STANDING SEAM METAL ROOFING RE: SPEC. ROOF SHEATHING RE: STRUCT. I-JOIST RAFTERS RE: STRUCT. CONT. BEVEL PLATE RE: STRUCT. INSULATION RE: SPEC (2) 14" LVL RE: STRUCT. HIGH TEMPERATURE ICE AND WATER SHIELD CONT. OVER RIDGE SLOPE PER ROOF PLAN SLOPE PER ROOF PLAN 1' - 2" 1' - 2" STL. BEAM RE: STRUCT. 1' - 2" 12 2 STANDING SEAM METAL ROOFING RE: SPEC. ROOF SHEATHING RE: STRUCT. LVL JOISTS RE: STRUCT. INSULATION RE: SPEC HIGH TEMPERATURE ICE AND WATER SHIELD CONT. OVER RIDGE JOIST HANGERS RE: STRUCT. 1 3/4" 8X8 DOUG-FIR STRUT RE: STRUCT STEEL I-BEAM RE: STRUCT. LAG-BOLTED THRU BEAM FLANGE FROM BELOW RE: STRUCT. SEE 1/A6.9 FOR TYP. ROOF EAVE NOTES 5/8" PLYWOOD OVER SLEEPERS TO CREATE WIRE CHASE FOR EXTERIOR LIGHT FIXTURES RE: RCP PAINT ALL EXPOSED THROUGH BOLTS RE:STRUCT. 3" HSS COLUMN WELDED TO B.O. BEAM & 6" X 6" X 1/2" STEEL BASE PLATE WELDED TO KNIFE PLATE RE: STRUCT. & SPEC SLOPE PER ROOF PLAN RE: ROOF PLAN BIRDS MOUTH CUT RATERS TO ACCEPT ANGLE OF STEEL I-BEAM US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Scale Date Drawn by Checked by Issue Date 3/23/2017 1:08:44 PM 1 1/2" = 1'-0" LILES RESIDENCE 2440 CHAMONIX LANE VAIL, CO 81657 A6.10 ROOF DETAILS 3-23-2017 CPM HB 3-23-2017 PERMIT SET 1 1/2" = 1'-0" 1 VALLEY DETAIL @ STANDING SEAM ROOF CRICKET 1 1/2" = 1'-0" 2 STL. BEAM DETAIL @ ROOF & WALL CONNECTION 1 1/2" = 1'-0" 3 SLOPED STL. BEAM DETAIL @ ROOF & WALL CONNECTION 1 1/2" = 1'-0" 4 ROOF DETAIL @ STANDING SEAM METAL ROOF RIDGE 1 1/2" = 1'-0" 5 ROOF DETAIL @ STL. BEAM 1 1/2" = 1'-0" 6 UPPER ROOF EAVE DETAIL @ FRONT ENTRY REVISION SCHEDULE # DESCRIPTION DATE 04/28/17