HomeMy WebLinkAboutB17-0053_A6.3_1493402456.pdfPRESSURE TREATED WOOD LEDGER
RE: STRUCT.
JOIST HANGER RE: STRUCT.
T.O. CONRETE SLAB
RE: FLOOR PLANS
T.O. PLYWOOD
RE: FLOOR PLANS
RE: STRUCT
RE:
STRUCT.
GRID
LINE
1"
DOOR SILL SET IN BED OF SEALANT
SEE 1/A6.2 FOR TYP. STONE
PATIO ASSEMBLY
2 1/2" 5 1/2"
SLOPE RE: PLANS
SEE DETAIL 1/A6.1 FOR
TYP. FOUNDATION NOTES
INTERIOR EXTERIOR
MECHANICAL ROOM
FILL JOIST CAVITY W/ BLOWN-IN
INSULATION RE: SPEC
TJI FLOOR JOISTS RE: STRUCT.
METAL "L" FLASHING W/ 1/2" TURN
UP BACK EDGE OF DOOR
PAINTED EPOXY FINISH
@ MECH ROOM FLOOR
PFSM FLASHING RE: SPEC - TURN UP
WALL AND UNDER WINDOW/ DOOR SILL
3/4" T&G PLYWOOD RE: STRUCT.
4 3/8" FLOOR ASSEMBLY
2 1/4"
2 1/8"
LINE OF PLYWOOD @ TYP. FLOOR ASSEMBLY
DROP STRUCTURE 2 1/8" @ ENTRY STONE
APPROX. 1 1/2" THICK FLAGSTONE
2 7/8" THICKENED GROUT BED W/
IN-FLOOR RADIANT HEAT
1 1/2"
2 7/8"
1 1/2"
2" 2# CLOSED CELL SPRAY FOAM
INSULATION BETWEEN 2X FURRING
P.T. BOTTOM PLATE
5/8" GWB
LINE OF 2X P.T. FURRING HELD 1" OFF
OF CONC. FOUNDATION WALL. SHIM
AND SECURE TO CONC. WALL AS REQ'D
1/2" 2"
1 1/2" 1"
2 1/2"
W.P. MEMBRANE CONTINUOUS
UNDER DOOR SILL LAP OVER L
METAL AND CONTINUE DOWN WALL
& LAP OVER CONC FOUNDATION
W.P. MEMBRANE MIN 6"
INTERIOR EXTERIOR
CONC. LEDGE RE: STRUCT.
GRID
LINE
T.O. LEDGE @ 6" MIN. BELOW
GRADE
RE: ELEV.
T.O. SLAB
RE: FLOOR PLANS
WATERPROOF MEMBRANE CONTINUOUS
FROM B.O. FOOTING UP WALL AND OVER
JOG IN CONCRETE TO T.O. CONC. WALL
SEE DETAIL 1/A6.1 FOR
TYP. FOUNDATION NOTES
SLOPE RE: PLANS
STONE VENEER WALL
ASSEMBLY PER 4/A6.7
2" 2# CLOSED CELL SPRAY FOAM
INSULATION BETWEEN 2X FURRING
P.T. BOTTOM PLATE
5/8" GWB
1/2" 2"
1 1/2" 1"
RE: STRUCT RE: STRUCT
RE: STRUCT
LINE OF 2X P.T. FURRING HELD 1" OFF
OF CONC. FOUNDATION WALL. SHIM
AND SECURE TO CONC. WALL AS REQ'D
T.O. CONC. @ 92' - 7"
RE: SECTIONS
1 1/2" 1" 5 1/2"
FILL ENTIRE CAVITY W/ INSULATION
FURRING AS REQ'D
6" MIN.
6" MIN.
2 1/2"
US Mail Only: P. O. Box 2378
Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Scale
Date
Drawn by
Checked by
Issue Date 3/23/2017 1:07:31 PM
3" = 1'-0"
LILES RESIDENCE
2440 CHAMONIX LANE
VAIL, CO 81657
A6.3
FOUNDATION
DETAILS
3-23-2017
CPM
HB
3-23-2017
PERMIT SET
3" = 1'-0"
2
FOUNDATION DETAIL @ FRONT ENTRY
DOOR THRESHOLD
3" = 1'-0"
1
FOUNDATION DETAIL @ STAIR WELL
REVISION SCHEDULE
# DESCRIPTION DATE
04/28/17