HomeMy WebLinkAboutB17-0053_A6.5_1493402458.pdfSTEEL BASE PLATE RE: STRUCT.
EXPANSION BOLT BASE PLATE TO CONC. PIER
HSS COLUMN WELDED TO TOP AND
BOTTOM STEEL PLATES RE: STRUCT.
8" X 8" STEEL BASE PLATE RE: STRUCT.
KNIFE PLATE W/ EXPOSED GALVANIZED
THRU-BOLTS RE: STRUCT.
1" NON EXPANSIVE GROUT BED
9 1/2"
APPLY ASPHALTIC DAMP
PROOFING TO STEEL
CONC. PIER RE: STRUCT.
COLUMN RE: STRUCT
NOTE: ALL STEEL TO BE SHOP PAINTED
W/ PROTECTIVE FINISH COAT OF PAINT
(RE: SPEC) INCLUDING AREAS TO BE
COVERED W/ DAMP PROOFING. ALL
PORTIONS OF STEEL WITHIN MASONRY/
CONCRETE OR BELOW GRADE TO BE
COATED W/ DAMP PROOFING INCLUDING
BOTTOM OF PLATE
REINFORCED CONC. SLAB PER STRUCT.
1/2" EXPANSION JOINT
EXPANSION BOLT/ EPOXY BOLT BASE
PLATE TO CONC. PIER RE: STRUCT.
HSS COLUMN WELDED TO TOP AND
BOTTOM STEEL PLATES. COVER
PORTION BELOW T.O. STONE W/ DAMP
PROOFING RE: STRUCT.
6" X 6" STEEL BASE PLATE RE: STRUCT.
1" NON EXPANSIVE GROUT BED
7 1/2"
SEE DETAIL 1/A6.2 FOR TYP. STONE
PATIO ASSEMBLY
RE: STRUCT
RE:
STRUCT.
8" X 8" STEEL BASE PLATE. PROTECT ALL
SURFACES W/ LAYER OF DAMP PROOFING
PRIOR TO INSTALLING (INCLUDING
BOTTOM) RE: STRUCT. RE: SPEC.
CONC. PIER RE: STRUCT.
2"
PROVIDE SEALANT JOINT
BETWEEN STEEL & STONE
NOTE: ALL STEEL TO BE SHOP PAINTED
W/ PROTECTIVE FINISH COAT OF PAINT
(RE: SPEC) INCLUDING AREAS TO BE
COVERED W/ DAMP PROOFING. ALL
PORTIONS OF STEEL WITHIN MASONRY/
CONCRETE OR BELOW GRADE TO BE
COATED W/ DAMP PROOFING INCLUDING
BOTTOM OF PLATE
8" X 8" COLUMN RE: STRUCT
TYPICAL ENTRY COLUMN BASE NOTES:
KNIFE PLATE W/ EXPOSED GALVANIZED
THRU-BOLTS RE: STRUCT.
INTERIOR OF GARAGE
EXTERIOR
2X TRIM BOARD AT GARAGE DOOR JAMB
BEYOND
RE: STRUCT. RE:
STRUCT.
SLOPE
GRID
LINE
SLOPE GARAGE SLAB AT THRESHOLD 1"
GARAGE DOOR
PROVIDE GASKET AT B.O. GARAGE DOOR
SEE DETAIL 1/A6.1 FOR TYP. FOUNDATION NOTES
RE: STRUCT.
T.O. CONRETE WALL
RE: STRUCT
3"4"4"
8 1/2"
SEE DETAIL 1/A6.4 FOR TYP. GARAGE FOUNDATION NOTES
15 MIL VAPOR BARRIER TURN
DOWN @ THICKENED EDGE
PRESSURE TREATED WOOD LEDGER
PRESSURE TREATED PLATE
T.O. CONRETE SLAB
RE: FLOOR PLANS
T.O. PLYWOOD
RE: FLOOR PLANS
RE: STRUCT
RE:
STRUCT.
GRID
LINE
6" MIN.
3" MIN.
INTERIOR
EXTERIOR INTERIOR
SEE DETAIL 1/A6.1 FOR
TYP. FOUNDATION NOTES
WALL ASSEMBLY PER 1/A6.7
SLOPE RE: PLANS
RE: STRUCT. 1" 1 1/2"
1/2"
2" 2# CLOSED CELL SPRAY FOAM
INSULATION BETWEEN 2X FURRING
P.T. BOTTOM PLATE
3/4" FINISH FLOOR
RE: FLOOR PLANS AND SPEC
2 1/4"
1 1/2" TOPPING SLAB W/ IN-FLOOR RADIANT
HEAT RE: FLOOR PLANS AND SPEC
FILL JOIST CAVITY W/ BLOWN-IN
INSULATION RE: SPEC
TJI FLOOR JOISTS RE: STRUCT.
5/8" GWB
LINE OF 2X P.T. FURRING HELD 1" OFF
OF CONC. FOUNDATION WALL. SHIM
AND SECURE TO CONC. WALL AS REQ'D
PFSM FLASHING RE: SPEC
EXTENDS INTO GRADE MIN 3"
T.O. CONC. WALL
RE: STRUCT
STONE VENEER WALL ASSEMBLY PER 4/A6.7
PRESSURE TREATED WOOD LEDGER
PRESSURE TREATED PLATE
T.O. CONRETE SLAB
RE: FLOOR PLANS
T.O. PLYWOOD
RE: FLOOR PLANS
RE: STRUCT
RE:
STRUCT.
GRID
LINE
6" MIN.
6" MIN
INTERIOR
EXTERIOR INTERIOR OF FIREPLACE
SEE DETAIL 1/A6.1 FOR
TYP. FOUNDATION NOTES
SLOPE RE: PLANS
RE: STRUCT 7" 3 1/2"
2" 5"
2" 2# CLOSED CELL SPRAY FOAM
INSULATION BETWEEN 2X FURRING
P.T. BOTTOM PLATE
FILL JOIST CAVITY W/ BLOWN-IN
INSULATION RE: SPEC
TJI FLOOR JOISTS RE: STRUCT.
5/8" GWB
2X4 FURRING HELD 7" OFF OF CONC.
FOUNDATION WALL
5/8" "TYPE X" GWB
FILL ENTIRE CAVITY W/ INSULATION
SLOPE RE: PLANS
INTERIOR
GRID
LINE
T.O. SLAB
RE: FLOOR PLANS
EXTERIOR
RE: STRUCT
RE: STRUCT
T.O. CONC. WALL
RE: STRUCT
2" 2# CLOSED CELL SPRAY FOAM
INSULATION BETWEEN 2X FURRING
LINE OF 2X P.T. FURRING HELD 3/4" OFF
OF CONC. FOUNDATION WALL. SHIM
AND SECURE TO CONC. WALL AS REQ'D
6" MIN.
6" MIN
STONE VENEER WALL ASSEMBLY PER 4/A6.7
P.T. BOTTOM PLATE
5/8" GWB
7 1/4"
1/4" 2" 5"
1 1/2" 3/4"
RE: STRUCT.
RE: STRUCT.
SEE DETAIL 1/A6.1 FOR TYP. FOUNDATION NOTES
2X8 FRAMING
US Mail Only: P. O. Box 2378
Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Scale
Date
Drawn by
Checked by
Issue Date 3/23/2017 1:07:56 PM
1 1/2" = 1'-0"
LILES RESIDENCE
2440 CHAMONIX LANE
VAIL, CO 81657
A6.5
FOUNDATION
DETAILS
3-23-2017
CPM
HB
3-23-2017
PERMIT SET
1 1/2" = 1'-0"
1
COLUMN DETAIL @ GRADE
1 1/2" = 1'-0"
2 COLUMN BASE DETAIL @ FRONT ENTRY
1 1/2" = 1'-0"
3
FOUNDATION DETAIL @ LOWER LEVEL
GARAGE DOOR THRESHOLD
1 1/2" = 1'-0"
5
FOUNDATION DETAIL @ JOIST HANGING
FROM CONC. WALL W/ WOOD SIDING
1 1/2" = 1'-0"
6 FOUNDATION DETAIL @ FIREPLACE
1 1/2" = 1'-0"
4
FOUNDATION DETAIL @ GRADE ABOVE
FINISHED FLOOR W/ 2X8 WALL
REVISION SCHEDULE
# DESCRIPTION DATE
04/28/17