HomeMy WebLinkAboutB17-0053_A6.7_1493402459.pdfINTERIOR EXTERIOR GRID LINE 1X8 VERTICAL RECLAIMED WOOD SIDING W/ SHIPLAP JOINT AND BUTT JOINT AT CORNERS - NO REVEAL 3D DRAINAGE MATERIAL CONTINUOUS BEHIND SIDING TO AIR VENT @ TOP & BOTTOM OF WOOD SIDING INSTALL OVER AIR AND WATER INFILTRATION BARRIER RE: SPEC SMART MEMBRANE VAPOR BARRIER TYP. RE: SPEC. PLYWOOD SHEATHING RE: STRUCT. 2X FRAMING RE: STRUCT. GWB PER INTERIOR DOCUMENTS RE: SPEC. CLOSED CELL SPRAY FOAM @ INSIDE OF SHEATHING @ CAVITY & CELLULOSE/FIBERGLASS INSULATION TO FILL REMAINDER OF CAVITY PER COVER SHEET & SPEC. INTERIOR EXTERIOR GRID LINE 1X8 HORIZONTAL CLEAR CEDAR WOOD SIDING W/ 1/8" CHANNEL SHIPLAP JOINT W/ CORNER TRIM PER DETAIL 5/A6.7 3D DRAINAGE MATERIAL CONTINUOUS BEHIND SIDING TO AIR VENT @ TOP & BOTTOM OF WOOD SIDING INSTALL OVER AIR AND WATER INFILTRATION BARRIER RE: SPEC SMART MEMBRANE VAPOR BARRIER TYP. RE: SPEC. PLYWOOD SHEATHING RE: STRUCT. 2X FRAMING RE: STRUCT. GWB PER INTERIOR DOCUMENTS RE: SPEC CLOSED CELL SPRAY FOAM @ INSIDE OF SHEATHING @ CAVITY & CELLULOSE/FIBERGLASS INSULATION TO FILL REMAINDER OF CAVITY PER COVER SHEET & SPEC. SEE 1/A6.7 FOR TYP. HORIZONTAL WOOD SIDING WALL ASSEMBLY INTERIOR EXTERIOR 2X4 WOOD CORNER ROUTERED AS SHOWN TO ACCEPT SIDING. COORDINATE W/ SIDING PROFILE. CORNER BLOCKING RE: STRUCT 3 1/2" 1 1/2" 1/2" 1/2" CLOSED CELL SPRAY FOAM @ INSIDE OF SHEATHING @ CAVITY & CELLULOSE/FIBERGLASS INSULATION TO FILL REMAINDER OF CAVITY PER COVER SHEET & SPEC. INTERIOR EXTERIOR GRID LINE 3D DRAINAGE MATERIAL CONTINUOUS BEHIND SIDING TO AIR VENT @ TOP & BOTTOM OF PFSM SIDING - INSTALL OVER AIR AND WATER INFILTRATION BARRIER RE: SPEC SMART MEMBRANE VAPOR BARRIER TYP. RE: SPEC. PLYWOOD SHEATHING RE: STRUCT. 2X FRAMING RE: STRUCT. GWB PER INTERIOR DOCUMENTS TYP. PFSM PANEL SYSTEM: 3/4" PLYWOOD OVER 3D DRAINAGE MEDIUM + AIR & WATER INFILTRATION BARRIER, SCREWED TO EXTERIOR SHEATHING WITH PFSM PANELS SILICONE GLUED TO 3/4" PLYWOOD. SEE ELEVATIONS FOR PANEL DIMENSIONS. SEE 7/A6.7 FOR EDGE/JOINT DETAIL CLOSED CELL SPRAY FOAM @ INSIDE OF SHEATHING @ CAVITY & CELLULOSE/FIBERGLASS INSULATION TO FILL REMAINDER OF CAVITY PER COVER SHEET & SPEC. INTERIOR EXTERIOR STONE VENEER WALL ASSEMBLY RE: SPEC & EXT. MATERIAL & COLOR INFO. SHEET 3D DRAINAGE MEDIUM OVER AIR & WATER INFILTRATION BARRIER (RE: SPEC) AT STONE VENEER EXCEPT PROVIDE W.P. MEMBRANE 3'-0" ABOVE GRADE AND 3' UP WALL@ ROOF AND DECK INTERSECTIONS 1/2" EXT. GRADE PLYWOOD SHEATHING RE: STRUCT. 5/8" GWB RE: SPEC. GRID LINE WOOD SIDING RE: ELEVS AND SPEC. 3D DRAINAGE MATERIAL CONT. BEHIND SIDING TO AIR VENT @ TOP AND BOTTOM OF WALL FLASHING EXTENDS UP BEHIND AIR & WATER INFILTRATION BARRIER MIN. 4", AND EXTENDS OUT OVER STONE MIN. 3" APPROX. 2" THICK CUT STONE CAP WITH TOP SLOPED MIN 10%. EXTENDS BEYOND FACE OF STONE APPROX. 1" 2X FRAMING RE: STRUCT CLOSED CELL SPRAY FOAM @ INSIDE OF SHEATHING @ CAVITY & CELLULOSE/FIBERGLASS INSULATION TO FILL REMAINDER OF CAVITY PER COVER SHEET & SPEC. SMART MEMBRANE VAPOR BARRIER TYP. RE: SPEC. PROVIDE GAP BETWEEN SIDING & FLASHING TO ALLOW VENTILATION & DRAINAGE INTERIOR EXTERIOR GRID LINE SMART MEMBRANE VAPOR BARRIER TYP. RE: SPEC. PLYWOOD SHEATHING RE: STRUCT. 2X FRAMING RE: STRUCT. GWB PER INTERIOR DOCUMENTS RE: SPEC. 6" STONE VENEER RE: SPEC + FINISH SCHEDULE CLOSED CELL SPRAY FOAM @ INSIDE OF SHEATHING @ CAVITY & CELLULOSE/FIBERGLASS INSULATION TO FILL REMAINDER OF CAVITY PER COVER SHEET & SPEC. 3D DRAINAGE MEDIUM OVER AIR & WATER INFILTRATION BARRIER (RE: SPEC) AT STONE VENEER EXCEPT PROVIDE W.P. MEMBRANE 3'-0" ABOVE GRADE AND 3' UP WALL@ ROOF AND DECK INTERSECTIONS TYPICAL WOOD SIDING ASSEMBLY (5) 2X6 POST RE: STRUCT 1/2" STEEL PLATE MOUNTED DIRECTLY TO STUDS. PLATE SET INTO PLYWOOD (NOTCHED OUT) AS SHOWN RE: STRUCT 4" 3" 1" 8X8 WOOD STRUT W/ KNIFE PLATE CONNECTION TO WALL W/ SURFACE MOUNTED THRU- BOLTS RE: STRUCT 4" 1' - 4" LINE OF KNIFE PLATE INSIDE WOOD STRUT *NOTE - KNIFE PLATE IS SHOWN DIAGRAMMATICALLY RE: STRUCT FOR ACTUAL KNIFE SIZES AND REQUIRED BOLT PATTERN & ELEV. RE: SECTIONS WRAP KNIFE PLATE W/ICE AND WATER SHIELD FOR 3/4" DEPTH OF SIDING. PROVIDE SEALANT JOINT BETWEEN WOOD AND KNIFE PLATE - PAINT KNIFE PLATE TO MATCH WINDOW COLOR GRID LINE TYPICAL PFSM SIDING ASSEMBLY RE: DETAIL 6/A6.7 V-PUNCH FROM GUTTER CRIMP TOOL BUTYL RUBBER SEALANT CAULK SONNEBORN ELASTIC ADHESIVE ONLY @ EDGE OF PLYWOOD PANEL PFSM PANEL WRAPS 3/4" PLYWOOD PANEL SET IN BUTYL CAULK JOINT AND HELD BY V-PUNCH AND SONNEBORN ADHESIVE. 3/4" PLY IS SCREWED INTO STUDS 3D DRAINAGE MATERIAL CONTINUOUS BEHIND SIDING TO AIR VENT @ TOP & BOTTOM OF PFSM SIDING - INSTALL OVER AIR AND WATER INFILTRATION BARRIER RE: SPEC T.O. PLYWOOD RE: FLOOR PLANS INTERIOR INTERIOR 3/4" FINISH FLOOR RE: FLOOR PLANS AND SPEC 2 1/4" 1 1/2" TOPPING SLAB W/ IN-FLOOR RADIANT HEAT RE: FLOOR PLANS AND SPEC FILL JOIST CAVITY W/ BLOWN-IN INSULATION RE: SPEC TJI FLOOR JOISTS RE: STRUCT. 5/8" GWB INTERIOR 5 1/2" STL. BEAM RE: STRUCT. 2X6 TOP PLATE OVER STEEL BEAM TURN DOWN DRYWALL AND PAINT TO MATCH DRYWALL CEILING RIM JOIST RE: STRUCT 2 3/4" 7/8" T.O. PLYWOOD RE: FLOOR PLANS INTERIOR INTERIOR 3/4" FINISH FLOOR RE: FLOOR PLANS AND SPEC 2 1/4" 1 1/2" TOPPING SLAB W/ IN-FLOOR RADIANT HEAT RE: FLOOR PLANS AND SPEC FILL JOIST CAVITY W/ BLOWN-IN INSULATION RE: SPEC TJI FLOOR JOISTS RE: STRUCT. 5/8" GWB RIM JOIST RE: STRUCT 1' - 0" FINISH TO FINISH LINE OF CLG. BEYOND 1X T&G US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Scale Date Drawn by Checked by Issue Date 3/23/2017 1:08:15 PM As indicated LILES RESIDENCE 2440 CHAMONIX LANE VAIL, CO 81657 A6.7 WALL DETAILS 3-23-2017 CPM HB 3-23-2017 PERMIT SET 1 1/2" = 1'-0" 2 WALL DETAIL - TYPICAL WALL @ VERTICAL SIDING 1 1/2" = 1'-0" 1 WALL DETAIL - TYPICAL WALL @ HORIZONTAL SIDING 1 1/2" = 1'-0" 5 WALL DETAIL - CORNER TRIM @ HORIZONTAL SIDING 1 1/2" = 1'-0" 6 WALL DETAIL - TYPICAL WALL @ PFSM PANELS 1 1/2" = 1'-0" 3 WALL DETAIL @ STONE TO WOOD SIDING TRANSITION 1 1/2" = 1'-0" 4 WALL DETAIL @ STONE VENEER 1 1/2" = 1'-0" 8 STRUT DETAIL @ WOOD SIDING 6" = 1'-0" 7 PFSM PANEL JOINT @ HORIZONTAL AND VERTICAL SEAM 1 1/2" = 1'-0" 9 WALL/FLOOR DETAIL @ KITCHEN STL. BEAM 1 1/2" = 1'-0" 10 RECESSED CEILING DETAIL @ LOWER LEVEL REVISION SCHEDULE # DESCRIPTION DATE 04/28/17