HomeMy WebLinkAboutB17-0053_A6.7_1493402459.pdfINTERIOR
EXTERIOR
GRID
LINE
1X8 VERTICAL RECLAIMED WOOD
SIDING W/ SHIPLAP JOINT AND BUTT
JOINT AT CORNERS - NO REVEAL
3D DRAINAGE MATERIAL CONTINUOUS
BEHIND SIDING TO AIR VENT @ TOP &
BOTTOM OF WOOD SIDING INSTALL
OVER AIR AND WATER INFILTRATION
BARRIER RE: SPEC
SMART MEMBRANE VAPOR
BARRIER TYP. RE: SPEC.
PLYWOOD SHEATHING RE: STRUCT.
2X FRAMING RE: STRUCT.
GWB PER INTERIOR DOCUMENTS RE: SPEC.
CLOSED CELL SPRAY FOAM @ INSIDE OF
SHEATHING @ CAVITY & CELLULOSE/FIBERGLASS
INSULATION TO FILL REMAINDER OF CAVITY PER
COVER SHEET & SPEC.
INTERIOR
EXTERIOR
GRID
LINE
1X8 HORIZONTAL CLEAR CEDAR WOOD
SIDING W/ 1/8" CHANNEL SHIPLAP JOINT W/
CORNER TRIM PER DETAIL 5/A6.7
3D DRAINAGE MATERIAL CONTINUOUS
BEHIND SIDING TO AIR VENT @ TOP &
BOTTOM OF WOOD SIDING INSTALL
OVER AIR AND WATER INFILTRATION
BARRIER RE: SPEC
SMART MEMBRANE VAPOR
BARRIER TYP. RE: SPEC.
PLYWOOD SHEATHING RE: STRUCT.
2X FRAMING RE: STRUCT.
GWB PER INTERIOR DOCUMENTS RE: SPEC
CLOSED CELL SPRAY FOAM @ INSIDE OF
SHEATHING @ CAVITY & CELLULOSE/FIBERGLASS
INSULATION TO FILL REMAINDER OF CAVITY PER
COVER SHEET & SPEC.
SEE 1/A6.7 FOR TYP. HORIZONTAL
WOOD SIDING WALL ASSEMBLY
INTERIOR
EXTERIOR
2X4 WOOD CORNER ROUTERED
AS SHOWN TO ACCEPT SIDING.
COORDINATE W/ SIDING PROFILE.
CORNER BLOCKING RE: STRUCT
3 1/2"
1 1/2"
1/2"
1/2"
CLOSED CELL SPRAY FOAM @ INSIDE OF
SHEATHING @ CAVITY & CELLULOSE/FIBERGLASS
INSULATION TO FILL REMAINDER OF CAVITY PER
COVER SHEET & SPEC.
INTERIOR
EXTERIOR
GRID
LINE
3D DRAINAGE MATERIAL CONTINUOUS
BEHIND SIDING TO AIR VENT @ TOP &
BOTTOM OF PFSM SIDING - INSTALL
OVER AIR AND WATER INFILTRATION
BARRIER RE: SPEC
SMART MEMBRANE VAPOR
BARRIER TYP. RE: SPEC.
PLYWOOD SHEATHING RE: STRUCT.
2X FRAMING RE: STRUCT.
GWB PER INTERIOR DOCUMENTS
TYP. PFSM PANEL SYSTEM: 3/4" PLYWOOD OVER 3D
DRAINAGE MEDIUM + AIR & WATER INFILTRATION
BARRIER, SCREWED TO EXTERIOR SHEATHING
WITH PFSM PANELS SILICONE GLUED TO 3/4"
PLYWOOD. SEE ELEVATIONS FOR PANEL
DIMENSIONS. SEE 7/A6.7 FOR EDGE/JOINT DETAIL
CLOSED CELL SPRAY FOAM @ INSIDE OF
SHEATHING @ CAVITY & CELLULOSE/FIBERGLASS
INSULATION TO FILL REMAINDER OF CAVITY PER
COVER SHEET & SPEC.
INTERIOR
EXTERIOR
STONE VENEER WALL ASSEMBLY RE: SPEC &
EXT. MATERIAL & COLOR INFO. SHEET
3D DRAINAGE MEDIUM OVER AIR & WATER
INFILTRATION BARRIER (RE: SPEC) AT STONE
VENEER EXCEPT PROVIDE W.P. MEMBRANE
3'-0" ABOVE GRADE AND 3' UP WALL@ ROOF
AND DECK INTERSECTIONS
1/2" EXT. GRADE PLYWOOD SHEATHING RE: STRUCT.
5/8" GWB RE: SPEC.
GRID
LINE
WOOD SIDING RE: ELEVS AND SPEC.
3D DRAINAGE MATERIAL CONT. BEHIND SIDING
TO AIR VENT @ TOP AND BOTTOM OF WALL
FLASHING EXTENDS UP BEHIND AIR &
WATER INFILTRATION BARRIER MIN. 4",
AND EXTENDS OUT OVER STONE MIN. 3"
APPROX. 2" THICK CUT STONE CAP
WITH TOP SLOPED MIN 10%. EXTENDS
BEYOND FACE OF STONE APPROX. 1"
2X FRAMING RE: STRUCT
CLOSED CELL SPRAY FOAM @ INSIDE OF
SHEATHING @ CAVITY & CELLULOSE/FIBERGLASS
INSULATION TO FILL REMAINDER OF CAVITY PER
COVER SHEET & SPEC.
SMART MEMBRANE VAPOR BARRIER TYP. RE: SPEC.
PROVIDE GAP BETWEEN SIDING & FLASHING
TO ALLOW VENTILATION & DRAINAGE
INTERIOR
EXTERIOR
GRID
LINE
SMART MEMBRANE
VAPOR BARRIER TYP.
RE: SPEC.
PLYWOOD SHEATHING RE: STRUCT.
2X FRAMING RE: STRUCT.
GWB PER INTERIOR DOCUMENTS RE: SPEC.
6" STONE VENEER RE: SPEC + FINISH
SCHEDULE
CLOSED CELL SPRAY FOAM @ INSIDE OF
SHEATHING @ CAVITY & CELLULOSE/FIBERGLASS
INSULATION TO FILL REMAINDER OF CAVITY PER
COVER SHEET & SPEC.
3D DRAINAGE MEDIUM OVER AIR &
WATER INFILTRATION BARRIER (RE:
SPEC) AT STONE VENEER EXCEPT
PROVIDE W.P. MEMBRANE 3'-0" ABOVE
GRADE AND 3' UP WALL@ ROOF AND
DECK INTERSECTIONS
TYPICAL WOOD SIDING ASSEMBLY
(5) 2X6 POST RE: STRUCT
1/2" STEEL PLATE MOUNTED
DIRECTLY TO STUDS. PLATE SET
INTO PLYWOOD (NOTCHED OUT) AS
SHOWN RE: STRUCT
4"
3"
1"
8X8 WOOD STRUT W/ KNIFE
PLATE CONNECTION TO WALL
W/ SURFACE MOUNTED THRU-
BOLTS RE: STRUCT
4"
1' - 4"
LINE OF KNIFE PLATE
INSIDE WOOD STRUT
*NOTE - KNIFE PLATE IS SHOWN
DIAGRAMMATICALLY RE: STRUCT
FOR ACTUAL KNIFE SIZES AND
REQUIRED BOLT PATTERN
& ELEV.
RE: SECTIONS
WRAP KNIFE PLATE W/ICE AND WATER
SHIELD FOR 3/4" DEPTH OF SIDING.
PROVIDE SEALANT JOINT BETWEEN
WOOD AND KNIFE PLATE - PAINT KNIFE
PLATE TO MATCH WINDOW COLOR
GRID
LINE
TYPICAL PFSM SIDING ASSEMBLY
RE: DETAIL 6/A6.7
V-PUNCH FROM GUTTER CRIMP TOOL
BUTYL RUBBER SEALANT CAULK
SONNEBORN ELASTIC
ADHESIVE ONLY @ EDGE OF
PLYWOOD PANEL
PFSM PANEL WRAPS 3/4" PLYWOOD
PANEL SET IN BUTYL CAULK JOINT
AND HELD BY V-PUNCH AND
SONNEBORN ADHESIVE. 3/4" PLY IS
SCREWED INTO STUDS
3D DRAINAGE MATERIAL CONTINUOUS
BEHIND SIDING TO AIR VENT @ TOP &
BOTTOM OF PFSM SIDING - INSTALL
OVER AIR AND WATER INFILTRATION
BARRIER RE: SPEC
T.O. PLYWOOD
RE: FLOOR PLANS
INTERIOR
INTERIOR
3/4" FINISH FLOOR
RE: FLOOR PLANS AND SPEC
2 1/4"
1 1/2" TOPPING SLAB W/ IN-FLOOR RADIANT
HEAT RE: FLOOR PLANS AND SPEC
FILL JOIST CAVITY W/ BLOWN-IN
INSULATION RE: SPEC
TJI FLOOR JOISTS RE: STRUCT.
5/8" GWB
INTERIOR
5 1/2"
STL. BEAM RE: STRUCT.
2X6 TOP PLATE OVER STEEL BEAM
TURN DOWN DRYWALL AND PAINT
TO MATCH DRYWALL CEILING
RIM JOIST RE: STRUCT
2 3/4" 7/8"
T.O. PLYWOOD
RE: FLOOR PLANS
INTERIOR
INTERIOR
3/4" FINISH FLOOR
RE: FLOOR PLANS AND SPEC
2 1/4"
1 1/2" TOPPING SLAB W/ IN-FLOOR RADIANT
HEAT RE: FLOOR PLANS AND SPEC
FILL JOIST CAVITY W/ BLOWN-IN
INSULATION RE: SPEC
TJI FLOOR JOISTS RE: STRUCT.
5/8" GWB
RIM JOIST RE: STRUCT
1' - 0" FINISH TO
FINISH
LINE OF CLG. BEYOND
1X T&G
US Mail Only: P. O. Box 2378
Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Scale
Date
Drawn by
Checked by
Issue Date
3/23/2017 1:08:15 PM
As indicated
LILES RESIDENCE
2440 CHAMONIX LANE
VAIL, CO 81657
A6.7
WALL
DETAILS
3-23-2017
CPM
HB
3-23-2017
PERMIT SET
1 1/2" = 1'-0"
2
WALL DETAIL - TYPICAL WALL @
VERTICAL SIDING
1 1/2" = 1'-0"
1
WALL DETAIL - TYPICAL WALL @
HORIZONTAL SIDING
1 1/2" = 1'-0"
5
WALL DETAIL - CORNER TRIM @
HORIZONTAL SIDING
1 1/2" = 1'-0"
6
WALL DETAIL - TYPICAL WALL @ PFSM
PANELS
1 1/2" = 1'-0"
3
WALL DETAIL @ STONE TO WOOD
SIDING TRANSITION
1 1/2" = 1'-0"
4
WALL DETAIL @ STONE VENEER
1 1/2" = 1'-0"
8 STRUT DETAIL @ WOOD SIDING
6" = 1'-0"
7
PFSM PANEL JOINT @ HORIZONTAL
AND VERTICAL SEAM
1 1/2" = 1'-0"
9
WALL/FLOOR DETAIL @ KITCHEN STL.
BEAM
1 1/2" = 1'-0"
10
RECESSED CEILING DETAIL @ LOWER
LEVEL
REVISION SCHEDULE
# DESCRIPTION DATE
04/28/17