Loading...
HomeMy WebLinkAboutB17-0053_A7.1_1493402461.pdf+91' - 6 15% HB BUILT IN SHELVING A7.1 2 4 A7.1 3 A7.1 72" WIDE X 24" TALL CUSTOM MASON-LITE MASONRY FIREPLACE OVER CMU BLOCK BUILD-UP 6' - 6" 3/8" 6' - 0" 3/8" LED LIGHT UNDER SLAB 9' - 0 3/8" @ BASE 3' - 6" 1' - 2" MAIN LEVEL 92' - 4 3/4" UPPER LEVEL 103' - 7 3/4" 3 A7.1 4' - 0 1/2" 1/2" 8" 2' - 0" 1' - 6 1/8" 3/8" 6' - 0" 3/8" 4" 1' - 2" 3" 6' - 0" 3" C9X13.4 C9 X 13.4 C CHANNEL CUT FLANGES FROM END OF C-CHANNEL TO ALLOW CONCEALED ATTACHMENT BEHIND STONE STONE VENEER RE: SPEC STL. PLATE - COORDINATE FINISH W/ OWNER TV LED LIGHT UNDER SLAB 3/8" STL. PLATE TRIM - COORDINATE FINISH W/ OWNER 1/2" X 8" STL. MANTLE WELDED TO STL. PLATE TRIM 4" COLORADO BUFF CUT STONE SLAB 65" TV WOOD SHELVING LINE OF FRAMING LED LIGHTING AT FRONT EDGE 72" WIDE X 24" TALL CUSTOM MASON-LITE MASONRY FIREPLACE OVER CMU BLOCK BUILD-UP 7 1/4" 5 1/2" 3' - 6" A7.2 7 9' - 0 3/8" @ BASE BOILER FLUES EXTEND THROUGH 2X8 WALL & SLAB CAP 3" 1' - 9" 3" 1' - 9" 3" 4' - 9" FURNITURE / BAR CART MAIN LEVEL 92' - 4 3/4" UPPER LEVEL 103' - 7 3/4" 3 A7.1 2 1/2" CLEAR 2 1/2" CLEAR 7 1/4" A7.2 7 9' - 0 3/8" @ BASE BOILER FLUES EXTEND THROUGH 2X8 WALL & SLAB CAP MAIN LEVEL 92' - 4 3/4" UPPER LEVEL 103' - 7 3/4" 4 A7.1 CMU BUILD UP SEE: MASON- LITE MANUF. SPECIFICATION 14" I.D. ICC RIS FLUE, INSTALL PER MANUFACTURER'S SPECIFICATION WRAP F.P. FLUE SURROUND IN 5/8" "TYPE X" GWB STL. FIREPLACE LINING 1/4" 1' - 6" 4" 1' - 2" 3' - 6" A7.1 6 5' - 9 7/8" MIN. 2" MIN. 1' - 6" INTERIOR OF FIREPLACE EXTERIOR GRID LINE 6" HEADER HANGER RE: STRUCT. BLOCKING RE: STRUCT. 1' - 6" STONE VENEER WALL ASSEMBLY PER 4/A6.7 5/8" "TYPE X" GWB STL. ANGLE RE: STRUCT. SEE 4/A6.9 FOR TYP. ROOF RAKE NOTES PFSM FLASHING EXTENDS UP BEHIND AIR & WATER INFILTRATION BARRIER AND EXTENDS OUT OVER ROOF PROVIDE GAP BETWEEN SIDING & FLASHING TO ALLOW VENTILATION & DRAINAGE LAP WATERPROOF MEMBRANE OVER FLASHING US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Scale Date Drawn by Checked by Issue Date 3/23/2017 1:08:54 PM As indicated LILES RESIDENCE 2440 CHAMONIX LANE VAIL, CO 81657 A7.1 FIREPLACE SHEET 3-23-2017 CPM HB 3-23-2017 PERMIT SET 1/2" = 1'-0" 1 LIVING ROOM FIREPLACE FLOOR PLAN 5 LIVING ROOM FIREPLACE 1/2" = 1'-0" 2 LIVING ROOM FIREPLACE ELEVATION 1/2" = 1'-0" 4 LIVING ROOM FIREPLACE SECTION 2 1/2" = 1'-0" 3 LIVING ROOM FIREPLACE SECTION 1 1 1/2" = 1'-0" 6 FIREPLACE DETAIL @ RAFTER CONNECTION @ STONE VENEER REVISION SCHEDULE # DESCRIPTION DATE 04/28/17