HomeMy WebLinkAboutB17-0053_A7.2_1493402462.pdfPFSM FLASHING OVER W.P. MEMBRANE OVER SLOPED 1 1/8" PLYWOOD AS REQ'D STORM COLLAR ATTACHED TO CHIMNEY PER MANUF. RECOMMENDATIONS TO CREATE WATERPROOF SEAL PROVIDE SOLID BLOCKING UNDER STEEL COLUMNS TERMINATION CAP: MAINTAIN CLEARANCES PRESCRIBED BY CODE 2X2 HSS STEEL FRAMING SLOPED AT 1/8":1'-0" 1/2" PLYWOOD WRAPS STEEL FRAMING W.P. MEMBRANE PFSM FLASHING WRAPS CHIMNEY CAP 3" 3' - 0" 1 12 12" MIN. PAINTED TO MATCH WINDOW COLOR 4X4 TUBE STEEL POST CANTED AT 1:12 WELDED TO 1/2" X 6" X 6" STEEL PLATE AT TOP AND BOTTOM SET IN A BED OF SEALANT OVER FLASHING, FASTENED WITH (4) EXPANSION BOLTS INTO FRAMING BELOW AND THROUGH BOLTED TO STEEL PLATE ABOVE LAP W.P. MEMBRANE OVER FLASHING 8" MIN. TYPE X 5/8" DRYWALL CONT. TO B.O. FLASHING 2 3/4" 9 1/4" PFSM PANELS RE: SPEC 2" OVERHANG 2" 2" A7.2 2 3 A7.2 4 A7.2 3' - 1 1/8" 5' - 0" 4 3/4" 1' - 3" 7' - 4 1/2" @ BASE 4' - 2 1/2" 4" 2' - 2 1/8" 3' - 6" FIREPLACE OPENING 3 1/8" MAIN LEVEL 92' - 4 3/4" UPPER LEVEL 103' - 7 3/4" 3 A7.2 HEAT & GLO MONTANA 42" FIREPLACE W/ GRAND OAK GAS LOG SET & STL. PANEL FINISH 1 1/2" COLORADO BUFF CUT STONE SLAB LINE OF FIREPLACE FLUE BEYOND DARK BRONZE PFSM PANEL SIDING RE: SPEC SLOPED 2X6 FRAMED WALL @ EAST SIDE OF FIREPLACE ONLY RE: SECTION 1/2" X 6" STL. MANTLE 55" TV ABOVE FIREPLACE 12 1" 1' - 2 1/2" 1 1/2" 2' - 6" 1/2" 7 1/8" 9' - 5 1/2" FINISH TO FINISH 5' - 0" 4' - 4" A7.2 6 TV 6' - 4 1/2" @ BASE DARK BRONZE PFSM PANEL SIDING RE: SPEC3/8" 3/8" REVEAL STL. PLATE - COORDINATE FINISH W/ OWNER 3/8" STL. PLATE TRIM - COORDINATE FINISH W/ OWNER 3' - 6" 1' - 11 3/4" 6 1/4" 2 1/8" MAIN LEVEL 92' - 4 3/4" UPPER LEVEL 103' - 7 3/4" 4 A7.2 1/2" 6 1/4" 2' - 0" FIREPLACE OPENING 1' - 4" 2 1/2" 11 1/2" SLOPED 2X6 FRAMED WALL @ EAST SIDE OF FIREPLACE ONLY 3' - 1 1/8" 3' - 0" HEAT & GLO MONTANA 42" FIREPLACE ON FRAMED PLATFORM 1/2" X 6" STL. MANTLE FLUE PER MANUF. DARK BRONZE PFSM PANEL SIDING RE: SPEC 55" TV ABOVE FIREPLACE 1 1/2" COLORADO BUFF CUT STONE SLAB T.O. HEARTH 1/4" ABOVE F.P. BRICK VENEER 1/4" FRAMING RE: STRUCT. DARK BRONZE PFSM PANEL SIDING RE: SPEC 3/8" REVEAL BETWEEN STONE CAP AND PSFM PANEL 4' - 6" FROM T.O. FINISH TO B.O.TV 7 5/8" MAIN LEVEL 92' - 4 3/4" UPPER LEVEL 103' - 7 3/4" 3 A7.2 12 1" A7.2 6 6' - 4 1/2" @ BASE 9' - 5 1/2" FINISH TO FINISH 3' - 0 1/2" 9 1/4" 15' - 11 1/2" 4' - 1 1/2" 3" STONE CHIMNEY CAP TERMINATION CAP: MAINTAIN CLEARANCES PRESCRIBED BY CODE STEEL ANGLE RE: STRUCT LAP W.P. MEMBRANE OVER FLASHING 8" MIN. TYP. STONE WALL ASSEMBLY. CHASE TOP COLLAR PROVIDE ELECTRONIC FLUE DAMPER AT INTERIOR FIREPLACE CHIMNEY: PER MANUF SPECIFICATION 2" 2" FILL 2X10 CAVITY WITH INSULATION TYPE X 5/8" DRYWALL CONT. TO B.O. STONE 2X10 JOISTS W/ TOPS CUT TO SLOPE PLY WOOD ABOVE @ 1/8" PER 1'-0" MAINTAIN 2" CLEARANCE TO COMBUSTIBLES 8' - 7 5/16" 3" 3' - 6" 3" LAP CONT. W.P. MEMBRANE OVER T.O. WALL & PLYWOOD CONT. FLASHING PAN UNDER STONE CONTINUES UP WALLS 8" MIN. W/ STORM COLLAR THAT TURNS UP @ FLUE 5" MIN 3" STONE CHIMNEY CAP SET IN BED OF MORTAR OVER FLASHING CAP 2" OVERHANG 1 12 1 12 ATTACH MIN/ (4) EXPANSION BOLTS RE: STRUCT. 4" 3' - 4 1/2" 3 3/8" 1' - 0 7/8" 9 7/16" BOILER FLUES EXTEND THROUGH SLAB CAP 6" MECHANICAL PVC VENT BOILER FLUES ROUTED THRU 2X8 WALL AND DRILLED THRU CHIMNEY CAP PAINTED TO MATCH WINDOW COLOR 4X4 TUBE STEEL POST CANTED AT 1:12 WELDED TO 1/2" X 6" X 6" STEEL PLATE AT TOP AND BOTTOM SET IN A BED OF SEALANT OVER FLASHING, FASTENED WITH (4) EXPANSION BOLTS INTO STONE ABOVE AND BELOW STORM COLLAR ATTACHED TO CHIMNEY PER MANUF. RECOMMENDATIONS TO CREATE WATERPROOF SEAL US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Scale Date Drawn by Checked by Issue Date 3/23/2017 1:09:04 PM As indicated LILES RESIDENCE 2440 CHAMONIX LANE VAIL, CO 81657 A7.2 FIREPLACE SHEET 3-23-2017 CPM HB 3-23-2017 PERMIT SET 1 1/2" = 1'-0" 6 CHIMNEY CAP DETAIL @ OUTDOOR FIREPLACE 1/2" = 1'-0" 1 OUTDOOR FIREPLACE FLOOR PLAN 1/2" = 1'-0" 2 OUTDOOR FIREPLACE ELEVATION 1/2" = 1'-0" 3 OUTDOOR FIREPLACE SECTION 1 1/2" = 1'-0" 4 OUTDOOR FIREPLACE SECTION 2 5 OUTDOOR FIREPLACE 1 1/2" = 1'-0" 7 CHIMNEY CAP DETAIL REVISION SCHEDULE # DESCRIPTION DATE 04/28/17