HomeMy WebLinkAboutB17-0053_A7.2_1493402462.pdfPFSM FLASHING OVER W.P.
MEMBRANE OVER SLOPED 1
1/8" PLYWOOD AS REQ'D
STORM COLLAR ATTACHED TO CHIMNEY
PER MANUF. RECOMMENDATIONS TO
CREATE WATERPROOF SEAL
PROVIDE SOLID BLOCKING
UNDER STEEL COLUMNS
TERMINATION CAP: MAINTAIN
CLEARANCES PRESCRIBED BY CODE
2X2 HSS STEEL FRAMING SLOPED AT 1/8":1'-0"
1/2" PLYWOOD WRAPS STEEL FRAMING
W.P. MEMBRANE
PFSM FLASHING WRAPS CHIMNEY CAP
3"
3' - 0" 1
12
12" MIN.
PAINTED TO MATCH WINDOW COLOR
4X4 TUBE STEEL POST CANTED AT 1:12
WELDED TO 1/2" X 6" X 6" STEEL PLATE
AT TOP AND BOTTOM SET IN A BED OF
SEALANT OVER FLASHING, FASTENED
WITH (4) EXPANSION BOLTS INTO
FRAMING BELOW AND THROUGH
BOLTED TO STEEL PLATE ABOVE
LAP W.P. MEMBRANE
OVER FLASHING 8" MIN.
TYPE X 5/8" DRYWALL
CONT. TO B.O. FLASHING
2 3/4"
9 1/4"
PFSM PANELS RE: SPEC
2" OVERHANG
2"
2"
A7.2
2
3
A7.2
4
A7.2
3' - 1 1/8"
5' - 0" 4 3/4"
1' - 3"
7' - 4 1/2" @ BASE
4' - 2 1/2" 4"
2' - 2 1/8"
3' - 6" FIREPLACE OPENING
3 1/8"
MAIN LEVEL
92' - 4 3/4"
UPPER LEVEL
103' - 7 3/4"
3
A7.2
HEAT & GLO MONTANA 42"
FIREPLACE W/ GRAND OAK GAS
LOG SET & STL. PANEL FINISH
1 1/2" COLORADO BUFF CUT STONE SLAB
LINE OF FIREPLACE
FLUE BEYOND
DARK BRONZE PFSM
PANEL SIDING RE: SPEC
SLOPED 2X6 FRAMED WALL @ EAST
SIDE OF FIREPLACE ONLY RE: SECTION
1/2" X 6" STL. MANTLE
55" TV ABOVE FIREPLACE
12
1"
1' - 2 1/2"
1 1/2"
2' - 6"
1/2"
7 1/8"
9' - 5 1/2"
FINISH TO
FINISH
5' - 0"
4' - 4"
A7.2
6
TV
6' - 4 1/2" @ BASE
DARK BRONZE PFSM
PANEL SIDING RE: SPEC3/8"
3/8" REVEAL
STL. PLATE - COORDINATE
FINISH W/ OWNER
3/8" STL. PLATE TRIM -
COORDINATE FINISH W/ OWNER
3' - 6"
1' - 11 3/4"
6 1/4"
2 1/8"
MAIN LEVEL
92' - 4 3/4"
UPPER LEVEL
103' - 7 3/4"
4
A7.2
1/2"
6 1/4"
2' - 0" FIREPLACE OPENING
1' - 4"
2 1/2"
11 1/2"
SLOPED 2X6 FRAMED WALL @ EAST
SIDE OF FIREPLACE ONLY
3' - 1 1/8"
3' - 0"
HEAT & GLO MONTANA 42" FIREPLACE
ON FRAMED PLATFORM
1/2" X 6" STL. MANTLE
FLUE PER MANUF.
DARK BRONZE PFSM
PANEL SIDING RE: SPEC
55" TV ABOVE FIREPLACE
1 1/2" COLORADO BUFF CUT STONE SLAB
T.O. HEARTH 1/4" ABOVE
F.P. BRICK VENEER 1/4"
FRAMING RE: STRUCT.
DARK BRONZE PFSM
PANEL SIDING RE: SPEC
3/8" REVEAL BETWEEN STONE
CAP AND PSFM PANEL
4' - 6" FROM
T.O. FINISH TO B.O.TV
7 5/8"
MAIN LEVEL
92' - 4 3/4"
UPPER LEVEL
103' - 7 3/4"
3
A7.2
12
1"
A7.2
6
6' - 4 1/2" @ BASE
9' - 5 1/2"
FINISH TO
FINISH
3' - 0 1/2"
9 1/4"
15' - 11
1/2"
4' - 1 1/2"
3" STONE CHIMNEY CAP
TERMINATION CAP: MAINTAIN
CLEARANCES PRESCRIBED BY CODE
STEEL ANGLE RE: STRUCT
LAP W.P. MEMBRANE
OVER FLASHING 8" MIN.
TYP. STONE WALL ASSEMBLY.
CHASE TOP COLLAR
PROVIDE ELECTRONIC FLUE DAMPER
AT INTERIOR FIREPLACE CHIMNEY:
PER MANUF SPECIFICATION
2" 2"
FILL 2X10 CAVITY WITH INSULATION
TYPE X 5/8" DRYWALL CONT. TO B.O. STONE
2X10 JOISTS W/ TOPS CUT TO SLOPE PLY
WOOD ABOVE @ 1/8" PER 1'-0" MAINTAIN 2"
CLEARANCE TO COMBUSTIBLES
8' - 7 5/16"
3"
3' - 6" 3" LAP CONT. W.P. MEMBRANE
OVER T.O. WALL & PLYWOOD
CONT. FLASHING PAN
UNDER STONE CONTINUES
UP WALLS 8" MIN. W/
STORM COLLAR THAT
TURNS UP @ FLUE 5" MIN
3" STONE CHIMNEY CAP SET IN BED
OF MORTAR OVER FLASHING CAP
2" OVERHANG
1
12
1
12
ATTACH MIN/ (4) EXPANSION BOLTS RE: STRUCT.
4"
3' - 4 1/2"
3 3/8"
1' - 0 7/8"
9 7/16"
BOILER FLUES EXTEND THROUGH SLAB CAP
6" MECHANICAL PVC VENT BOILER
FLUES ROUTED THRU 2X8 WALL AND
DRILLED THRU CHIMNEY CAP
PAINTED TO MATCH WINDOW COLOR 4X4 TUBE
STEEL POST CANTED AT 1:12 WELDED TO 1/2" X 6" X
6" STEEL PLATE AT TOP AND BOTTOM SET IN A BED
OF SEALANT OVER FLASHING, FASTENED WITH (4)
EXPANSION BOLTS INTO STONE ABOVE AND BELOW
STORM COLLAR ATTACHED TO CHIMNEY
PER MANUF. RECOMMENDATIONS TO
CREATE WATERPROOF SEAL
US Mail Only: P. O. Box 2378
Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Scale
Date
Drawn by
Checked by
Issue Date 3/23/2017 1:09:04 PM
As indicated
LILES RESIDENCE
2440 CHAMONIX LANE
VAIL, CO 81657
A7.2
FIREPLACE
SHEET
3-23-2017
CPM
HB
3-23-2017
PERMIT SET
1 1/2" = 1'-0"
6
CHIMNEY CAP DETAIL @ OUTDOOR
FIREPLACE
1/2" = 1'-0"
1
OUTDOOR FIREPLACE FLOOR PLAN
1/2" = 1'-0"
2 OUTDOOR FIREPLACE ELEVATION
1/2" = 1'-0"
3 OUTDOOR FIREPLACE SECTION 1
1/2" = 1'-0"
4 OUTDOOR FIREPLACE SECTION 2
5
OUTDOOR FIREPLACE
1 1/2" = 1'-0"
7 CHIMNEY CAP DETAIL
REVISION SCHEDULE
# DESCRIPTION DATE
04/28/17