HomeMy WebLinkAboutB17-0053_A8.1_1493402475.pdfWINDOW RE: WINDOW SCHEDULE,
APPLY CONTINUOUS BEAD OF
SEALANT TO BACK SIDE OF NAILING
FLANGE PRIOR TO INSTALLING
WINDOW SET IN BED OF SEALANT
WOOD SIDING RE: ELEVATIONS FOR
TYPE AND LOCATION
LAP 2ND LAYER OF WATERPROOF MEMBRANE
OVER AIR & WATER INFILTRATION BARRIER
GRID
LINE
CUSTOM 4/4 SILL PER
INTERIOR DOCUMENTS
INTERIOR
EXTERIOR
3X3 WOOD TRIM WITH
SLOPED TOP TO DRAIN
MIN 1:12
SEALANT JOINT BETWEEN WINDOW
AND R.O. @ INTERIOR SIDE OF WINDOW
1/2"
SEE TYPICAL WALL DETAIL & COVER
SHEET FOR NOTES & ASSEMBLIES
TYPICAL WINDOW SILL DETAIL NOTES:
3D DRAINAGE MEDIUM
1ST LAYER OF WATERPROOF MEMBRANE
OVER SHEATHING AND UNDER WINDOW
SILL AND LAP UP SIDES OF JAMB MIN 6"
AIR & WATER INFILTRATION BARRIER LAPS
OVER NAILING FLANGE
WINDOW RE: WINDOW SCHEDULE,
APPLY CONTINUOUS BEAD OF
SEALANT TO BACK SIDE OF NAILING
FLANGE PRIOR TO INSTALLING
IN-FILL W/ SPRAY FOAM
INSULATION AND SHIM AS REQ'D
WOOD SIDING RE: ELEVATIONS
FOR TYPE AND LOCATION
LAP AIR & WATER INFILTRATION BARRIER OVER
1ST LAYER OF WATERPROOF MEMBRANE BUT
HOLD BACK APPROX 1 1/2" FROM WINDOW
LAP 2ND LAYER OF WATERPROOF
MEMBRANE OVER 1ST LAYER AND OVER
AIR & WATER INFILTRATION BARRIER
GRID
LINE
INTERIOR
EXTERIOR
DRYWALL WRAP W/ J-MOLDING
@ WINDOW FRAME
LAP 1ST LAYER OF WATERPROOF MEMBRANE
OVER SHEATHING AND OVER NAILING FLANGE
SEALANT JOINT AND BACKER ROD
3X3 WOOD TRIM
SEALANT JOINT BETWEEN
WINDOW AND R.O.
SHIM DRYWALL AS REQUIRED
3D DRAINAGE MEDIUM LAPS OVER
WATERPROOF MEMBRANE & AIR AND
WATER INFILTRATION BARRIER RE: SPEC.
SEE TYPICAL WALL DETAIL & COVER
SHEET FOR NOTES & ASSEMBLIES
TYPICAL JAMB DETAIL NOTES:
1/4" SEALANT JOINT & BACKER ROD
WINDOW RE: WINDOW SCHEDULE,
APPLY CONTINUOUS BEAD OF
SEALANT TO BACK SIDE OF NAILING
FLANGE PRIOR TO INSTALLING
IN-FILL W/ SPRAY FOAM INSULATION AND
SHIM AS REQ'D RE: SPEC
3D DRAINAGE MEDIUM LAPS OVER AIR &
WATER INFILTRATION BARRIER LAPS
OVER TOP OF FLASHING 3" MIN RE: SPEC.
LAP WATERPROOF MEMBRANE OVER
NAILING FLANGE AND CONTINUE UP UNDER
FLASHING AND UNDER AIR & WATER
INFILTRATION BARRIER
3X3 WOOD TRIM
GRID
LINE
INTERIOR
EXTERIOR
FLASHING TO MATCH WINDOW
COLOR RE: SPEC
HEADER RE: STRUCT.
WOOD SIDING RE: ELEVATIONS
FOR TYPE AND LOCATION
SEALANT JOINT BETWEEN WINDOW
AND R.O. @ INTERIOR SIDE OF WINDOW
DRYWALL WRAP W/ J-MOLDING
@ WINDOW FRAME
SHIM DRYWALL AS REQUIRED
TYPICAL WINDOW HEAD DETAIL NOTES:
GRID
LINE
INTERIOR
EXTERIOR
ALUMINUM OR PFSM FLASHING TO
MATCH WINDOWS. SEPARATE
FROM PFSM CLAD PANELS AS
REQ'D W/ ICE AND WATER SHIELD
OR NEOPRENE TAPE OR OTHER
APPROPRIATE PRODUCT TO
SEPARATE DISSIMILAR METALS
AND SEALANT. RE: SPEC.
PROVIDE CONTINUOUS 1/8"
WEEP BETWEEN PFSM PANEL
AND ALUMINUM FLASHING TO
ALLOW ASSEMBLY TO DRAIN
SEE 3/A8.1 FOR TYP. WINDOW
HEAD DETAILS NOTES
SEE 6/A6.7 FOR PFSM CLAD
PANEL ASSEMBLY.
SEE 6/A6.7 FOR PFSM CLAD
PANEL ASSEMBLY.
GRID
LINE
INTERIOR
EXTERIOR
SEPARATE PFSM PANELS FROM WINDOWS W/
SEALANT AND ICE AND WATER SHIELD TYPE
SELF ADHERED FLASHING OR NEOPRENE
TAPE OR OTHER APPROPRIATE PRODUCT TO
SEPARATE DISSIMILAR METALS
SEE 2/A8.1 FOR TYP. WINDOW
JAMB DETAILS NOTES
SEE 4/A6.7 FOR TYP. EXT.
STONE VENEER WALL
ASSEMBLY
2" STONE CUT STONE SILL
CAP SLOPED 10% MIN. TO
DRAIN
GRID
LINE
INTERIOR
EXTERIOR
SLOPE 1:12 MIN
1/2"
1/4" SEALANT JOINT. DO NOT LET
WINDOW TOUCH MORTAR/STONE
SEE 1/A8.1 FOR TYP. WINDOW
SILL DETAILS NOTES
SEE 4/A6.7 TYP. EXT. STONE
VENEER WALL ASSEMBLY
GRID
LINE
INTERIOR
EXTERIOR
1/4" SEALANT JOINT AND
BACKER ROD DO NOT LET
MORTAR TOUCH WINDOW
SEE 2/A8.1 FOR TYP. WINDOW
JAMB DETAILS NOTES
INTERIOR
EXTERIOR
GRID
LINE
GRID
LINE
WINDOWS RE: WINDOW SCHEDULE
FILL W/ EXPANDING SPRAY FOAM
INSULATION AND SHIM
SEALANT JOINT AND BACKER ROD
PROVIDE CAULK JOINT BETWEEN
WINDOW FRAME AND R.O. @
INTERIOR TYP.
WOOD SIDING. RE: ELEVATIONS &
DETAILS ON A6.7
SEE 2/A8.1 FOR TYP. WINDOW
JAMB INSTALL & WATERPROOFING
4X4 WOOD SILL BELOW IF APPLICABLE
CORNER POST RE: STRUCT.
DRYWALL WRAP W/ J-MOLDING
AND SEALANT JOINT
3" 5" 1/2"
8 1/2"
GRID
LINE
INTERIOR EXTERIOR
ALUMINUM OR PFSM FLASHING TO
MATCH WINDOW COLOR - SEPARATE
DISSIMILAR METALS AS REQ'D W/ SELF
ADHERED FLASHING OR SIMILAR
PRODUCT
SEE 3/A8.1 FOR TYP. WINDOW
HEAD DETAILS NOTES
MAINTAIN GAP TO
ALLOW DRAINAGE
MEDIUM TO DRAIN
RE: ELEVATIONS FOR TYPE
AND LOCATION OF FINISH
2"X4"X1/4" STEEL ANGLE ATTACHED
TO SOLID BLOCKING W/ 3/8"X3" LAG
BOLTS @ 3' O.C. SHOP PAINT ANGLE
W/ PROTECTIVE PAINT TO MATCH
WINDOW COLOR RE: SPEC
SEPARATE DISSIMILAR METALS AS
REQ'D W/ SELF ADHERED FLASHING
OR SIMILAR PRODUCT
WINDOW HEADER RE: STRUCT.
GRID
LINE
INTERIOR
EXTERIOR 1/4"
1/2"
SEE 1/A8.1 FOR TYP. WINDOW
SILL DETAILS NOTES
1/4" SEALANT JOINT
& BACKER ROD.
SEE 6/A6.7 FOR PFSM CLAD
PANEL ASSEMBLY.
SEPARATE PFSM PANELS FROM WINDOWS W/
SEALANT AND ICE AND WATER SHIELD TYPE
SELF ADHERED FLASHING OR NEOPRENE
TAPE OR OTHER APPROPRIATE PRODUCT TO
SEPARATE DISSIMILAR METALS
INTERIOR
EXTERIOR
GRID
LINE
GRID
LINE
WINDOWS RE: WINDOW SCHEDULE
FILL W/ EXPANDING SPRAY FOAM
INSULATION AND SHIM
SEALANT JOINT AND BACKER ROD
PROVIDE CAULK JOINT BETWEEN
WINDOW FRAME AND R.O. @
INTERIOR TYP.
PFSM SIDING. RE: ELEVATIONS
& DETAILS ON A6.7
SEE 2/A8.1 FOR TYP. WINDOW
JAMB INSTALL & WATERPROOFING
CORNER POST RE: STRUCT.
DRYWALL WRAP W/ J-MOLDING
AND SEALANT JOINT
5 1/2"
5 1/2"
1' - 0"
1' - 0"
GRID
LINE
INTERIOR
EXTERIOR
SEE 2/A8.1 FOR TYP. WINDOW
JAMB DETAILS NOTES
1/4" SEALANT JOINT
& BACKER ROD.
2"X4"X1/4" STEEL ANGLE ATTACHED
TO SOLID BLOCKING W/ 3/8"X3" LAG
BOLTS @ 3' O.C. SHOP PAINT ANGLE
W/ PROTECTIVE PAINT TO MATCH
WINDOW COLOR RE: SPEC
SEPARATE DISSIMILAR METALS
AS REQ'D W/ SELF ADHERED
FLASHING OR SIMILAR PRODUCT
RE: ELEVATIONS FOR TYPE
AND LOCATION OF FINISH
US Mail Only: P. O. Box 2378
Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Scale
Date
Drawn by
Checked by
Issue Date 3/23/2017 1:11:55 PM
3" = 1'-0"
LILES RESIDENCE
2440 CHAMONIX LANE
VAIL, CO 81657
A8.1
WINDOW
DETAILS
3-23-2017
CPM
HB
3-23-2017
PERMIT SET
3" = 1'-0"
1
WINDOW SILL DETAIL @ WOOD SIDING
3" = 1'-0"
2
WINDOW JAMB DETAIL @ WOOD SIDING
3" = 1'-0"
3
WINDOW HEAD DETAIL @ WOOD SIDING
3" = 1'-0"
6
WINDOW HEAD DETAIL @ PFSM CLAD
PANELING
3" = 1'-0"
5
WINDOW JAMB DETAIL @ PFSM CLAD
PANELING
3" = 1'-0"
7
WINDOW SILL DETAIL @ STONE
VENEER
3" = 1'-0"
8
WINDOW JAMB DETAIL @ STONE
VENEER
3" = 1'-0"
10 WINDOW CORNER DETAIL
3" = 1'-0"
9 WINDOW HEAD @ STEEL ANGLE
3" = 1'-0"
4 WINDOW SILL @ PFSM CLAD PANELING
3" = 1'-0"
11 WINDOW CORNER DETAIL @ STAIR
3" = 1'-0"
12 WINDOW JAMB @ STEEL ANGLE
REVISION SCHEDULE
# DESCRIPTION DATE
04/28/17