HomeMy WebLinkAboutB17-0053_A8.2_1493402476.pdfEXTERIOR INTERIOR
CUSTOM WOOD DOOR RE:SPEC
CUSTOM MADE WOOD DOOR JAMB
TO DIMENSIONS SPECIFIED
(1) 1 3/4" X 5.5" LVL MICROLAMS
9/16" WOOD TRIM
ICE & WATER SHIELD CONTINUOUS
UNDER SILL @ UPPER WINDOW LAPS
OVER DOOR FRAME BELOW
SEALANT
2 3/4"
3 7/8"
3/16"
3/8"
GRID
LINE
IN-FILL W/ EXPANDING SPRAY FOAM
INSULATION AND SHIM AS REQ.
2 1/8"
1"
2X WOOD TRIM
1 1/8"
1 1/8"
3 1/4"
3/4" 1 3/4" 3/4"
WINDOW HEAD SECTION OUTLINE BEYOND
TO SHOW ADJACENT SIDE LIGHT CONDITION
TRIM TO ALIGN W/ TRIM @
ADJACENT WINDOW CONDITION
SEE ENLARGED EXTERIOR
ELEVATION @ 4/A4.4
EXTERIOR
INTERIOR
CUSTOM WOOD DOOR JAMB
TO MADE DIMENSIONS SPECIFIED
(1) 1 3/4" X 5.5" LVL MICROLAMS
SEALANT
2 3/4"
3/8" GRID
LINE
SPRAY FOAM VOID & SHIM AS
REQ.
CUSTOM 4/4" WOOD JAMB
EXTENSION W/ 5/8" WOOD TRIM
3/8"
3/16" 3 7/8" 3/16"
1 1/8"
2 1/2"
2X WOOD TRIM
1 1/8"
1 1/8"
9/16" WOOD TRIM
CONTINUOUS @ WINDOW TO
WINDOW CONDITION ABOVE
CUSTOM WOOD DOOR RE:SPEC
SEE ENLARGED EXTERIOR
ELEVATION @ 4/A4.4
EXTERIOR INTERIOR
9/16" WOOD TRIM
WINDOW HEAD SECTION
ICE & WATER SHIELD CONTINUOUS
UNDER SILL @ UPPER WINDOW LAPS
OVER WINDOW NAILING FLANGE
SEALANT
2 3/4"
3/8"
3/8"
GRID
LINE
(1) 1 3/4" X 5.5" LVL MICROLAMS RIPPED
1/2"
1/2" PLYWOOD FILLER ATTACHED TO
DOOR FRAME SIDE OF HEAD ONLY
CUSTOM 4/4" WOOD JAMB EXTENSION
CUSTOM 4/4" WOOD JAMB EXTENSION
5/8" X 5/8" WOOD TRIM
3/16"
3 7/8"
3/16"
5/8" X 5/8" WOOD TRIM
IN-FILL W/ EXPANDING SPRAY FOAM
INSULATION AND SHIM AS REQ'D
2X WOOD TRIM
FILL ALL VOIDS W/ SPRAY
FOAM INSULATION
EDGE OF TRIM ALIGNS W/
EDGE OF TRIM @ ENTRY
SEE ENLARGED EXTERIOR
ELEVATION @ 4/A4.4
3"
EXTERIOR
INTERIOR
(1) 1 3/4" X 5.5" LVL MICROLAMS
9/16" WOOD TRIM RE: SPEC
SEALANT
2 3/4"
3/8" GRID
LINE
1/2" PLYWOOD FILLER ATTACHED TO
DOOR FRAME SIDE ONLY
3/8"
CUSTOM 4/4 WOOD JAMB EXTENSION
3/16" 3 7/8" 3/16"
5/8" X 5/8" WOOD TRIM
IN-FILL W/ EXPANDING SPRAY
FOAM INSULATION & SHIM
2X WOOD TRIM
NOTE- FRONT ENTRY DOOR IS BELOW
EDGE OF TRIM TO ALIGN W/ EDGE
OF TRIM @ DOOR BELOW
SEE ENLARGED EXTERIOR
ELEVATION @ 4/A4.4
INTERIOR OF GARAGE
EXTERIOR
SLOPE
GRID
LINE 7" STEP
SEE DETAIL 1/A6.1 FOR TYP.
FOUNDATION NOTES
T.O. CONRETE WALL
RE: STRUCT
3"4"4"
SLOPE RE: PLANS
SEE DETAIL 1/A6.4 FOR TYP.
GARAGE FOUNDATION NOTES
W.P. EPOXY LIQUID GRANITE
FLOORING OVER CONC. SLAB
PFSM FLASHING RE: SPEC EXTENDS
UNDER DOOR SILL AND TURNS UP 1/2"
DOOR SILL SET IN BED OF
SEALANT OVER PFSM FLASHING
DRAINAGE MEDIUM CONTINUOUS OVER
FLASHING SO WALL CAN DRAIN
STONE CAP RE: SPEC
W.P. MEMBRANE CONTINUOUS UNDER
DOOR SILL LAP OVER L METAL AND
CONTINUE DOWN WALL & LAP OVER CONC
FOUNDATION W.P. MEMBRANE MIN 6"
INTERIOR EXTERIOR
ALUMINUM OR PFSM FLASHING TO MATCH
WINDOWS. SEPARATE FROM PFSM CLAD
PANELS AS REQ'D W/ ICE AND WATER SHIELD
OR NEOPRENE TAPE OR OTHER APPROPRIATE
PRODUCT TO SEPARATE DISSIMILAR METALS
AND SEALANT. RE: SPEC.
PROVIDE CONTINUOUS 1/8" WEEP BETWEEN
PFSM PANEL AND FLASHING TO ALLOW
ASSEMBLY TO DRAIN
SEE 6/A6.7 FOR PFSM CLAD PANEL ASSEMBLY
GRID
LINE
SEE 1/A8.1 FOR TYP. WINDOW SILL DETAILS NOTES
1/4" SEALANT JOINT & BACKER ROD
SEPARATE PFSM PANELS FROM WINDOWS W/
SEALANT AND ICE AND WATER SHIELD TYPE
SELF ADHERED FLASHING OR NEOPRENE
TAPE OR OTHER APPROPRIATE PRODUCT TO
SEPARATE DISSIMILAR METALS
BELFER UPLIGHT WALL SCONCE RE: RCP
SEE 3/A8.1 FOR TYP. WINDOW HEAD DETAILS NOTES
STL. BEAM RE: STRUCT.
5/8" GWB RE: SPEC.
DRYWALL WRAP
INTERIOR
EXTERIOR
ALUMINUM OR PFSM FLASHING TO MATCH
WINDOWS. SEPARATE AS REQ'D FROM DISSIMILAR
METAL FLASHING/ WINDOWS W/ ICE AND WATER
SHIELD OR NEOPRENE TAPE OR OTHER
APPROPRIATE PRODUCT TO SEPARATE
DISSIMILAR METALS AND SEALANT. RE: SPEC.
PROVIDE CONTINUOUS 1/8" WEEP
BETWEEN C-CHANNEL AND FLASHING
TO ALLOW ASSEMBLY TO DRAIN
GRID
LINE
SEE 1/A8.1 FOR TYP. WINDOW SILL DETAILS NOTES
1/4" SEALANT JOINT & BACKER ROD
SEE 3/A8.1 FOR TYP. WINDOW HEAD DETAILS NOTES
10X15.3 C-CHANNEL HEADER LAG-
BOLTED INTO SOLID BLOCKING W/ PAIR
3/8"X3" LAG BOLTS @ APPROX. 4' O.C.
PAINT TO MATCH STEEL RE: STRUCT
LINE OF STEEL ANGLE BEYOND @ JAMB
SOLID BLOCKING RE: STRUCT.
ALUMINUM OR PFSM FLASHING TO MATCH
WINDOWS. SEPARATE AS REQ'D FROM DISSIMILAR
METAL FLASHING/ WINDOWS W/ ICE AND WATER
SHIELD OR NEOPRENE TAPE OR OTHER
APPROPRIATE PRODUCT TO SEPARATE
DISSIMILAR METALS AND SEALANT. RE: SPEC.
DRYWALL WRAP
FINISHED FLOOR RE: PLANS
3/4" T&G PLYWOOD RE: STRUCT.
14" WOOD I-JOISTS RE: STRUCT.
INSULATION RE: SPEC & COVER SHEET
FINISH RE: RCP
T.O. PLYWOOD
RE: SECTIONS / PLANS
INTERIOR
INTERIOR
EXTERIOR
GRID
LINE
WOOD JOISTS RE: STRUCT
3X6 DRIP THROUGH DECKING
T.O. DECKING
RE: SECTIONS / PLANS
CONT. BUG SCREEN STAPLED TO
LEDGER WRAPPED OVER AIR
VENT MATERIAL TO CREATE MIN
1/2" VENT AT TOP OF THE WALL.
SEE 1/A8.1 FOR TYP. WINDOW
SILL DETAILS NOTES
STL. BEAM RE: STRUCT.
7 1/4"
SLIDING PATIO DOOR RE: WINDOW
SCHEDULE, APPLY CONTINUOUS BEAD OF
SEALANT TO BACK SIDE OF NAILING
FLANGE PRIOR TO INSTALLING
1' - 0 1/8"
HEADER RE: STRUCT.
FUR CLG. APPROX. 12" TO CREATE
SPACE FOR SUP. AIR DUCT @
WINDOWS @ MAIN LEVEL &
RECESSED CEILING @ LOWER
LEVEL RE: RCP.
US Mail Only: P. O. Box 2378
Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Scale
Date
Drawn by
Checked by
Issue Date
3/23/2017 1:12:03 PM
3" = 1'-0"
LILES RESIDENCE
2440 CHAMONIX LANE
VAIL, CO 81657
A8.2
WINDOW &
DOOR
DETAILS
3-23-2017
CPM
HB
3-23-2017
PERMIT SET
3" = 1'-0"
1
FRONT ENTRY DOOR HEADER TO
WINDOW SILL
3" = 1'-0"
2
FRONT ENTRY DOOR JAMB TO WINDOW
JAMB DETAIL
3" = 1'-0"
3
FRONT ENTRY WINDOW HEADER TO
WINDOW SILL DETAIL
3" = 1'-0"
4
FRONT ENTRY WINDOW JAMB TO
WINDOW JAMB DETAIL (ABOVE DR)
3" = 1'-0"
5
DOOR SILL DETAIL @ GARAGE SIDE
ENTRY
3" = 1'-0"
6
WINDOW HEAD DETAIL @ LIVING ROOM
3" = 1'-0"
8
WINDOW HEAD DETAIL @ STAIR WELL
C-CHANNEL
3" = 1'-0"
7
DOOR & WINDOW DETAIL @ LIVING
ROOM DECK
REVISION SCHEDULE
# DESCRIPTION DATE
04/28/17