HomeMy WebLinkAboutB17-0053_A8.3_1493402477.pdfGARAGE DOOR AND TRACK PER SPECIFICATIONS
1 X 6 TRIM
R.O.
1 X 8 WITH KERF CUT BACK
GARAGE DOOR TRACK
1/4" SEALANT JOINT AND BACKER ROD
GRID
LINE
7 1/2"
5 1/2"
TYPICAL INTERIOR TRIM RE: SPEC.
PROVIDE WEATHER STRIPPING ON ALL 4 SIDES
*NOTE - PROVIDE BLOCKING BEHIND
DRYWALL AS REQ'D FOR ATTACHMENT OF
GARAGE DOOR HARDWARE. NO EXPOSED
2X BLOCKING MAY BE UTILIZED
INTERIOR
EXTERIOR
HSS COLUMN RE: STRUCT.
STONE VENEER WALL ASSEMBLY PER 4/A6.7
7/8"
FINISHED FLOOR RE: PLANS
3/4" T&G PLYWOOD RE: STRUCT.
14" WOOD I-JOISTS RE: STRUCT.
INSULATION RE: SPEC & COVER SHEET
FINISH RE: RCP
T.O. PLYWOOD
RE: SECTIONS / PLANS
INTERIOR
INTERIOR
EXTERIOR
GRID
LINE
WOOD JOISTS RE: STRUCT
3X6 DRIP THROUGH DECKING
T.O. DECKING
RE: SECTIONS / PLANS
CONT. BUG SCREEN STAPLED TO
LEDGER WRAPPED OVER AIR
VENT MATERIAL TO CREATE MIN
1/2" VENT AT TOP OF THE WALL.
7 1/4"
1" STEP
DOOR SILL SET IN BED OF SEALANT
PFSM FLASHING RE: SPEC - TURN UP
WALL AND UNDER WINDOW/ DOOR SILL
W.P. MEMBRANE CONTINUOUS UNDER
DOOR SILL LAP OVER L METAL AND
CONTINUE DOWN WALL & LAP OVER CONC
FOUNDATION W.P. MEMBRANE MIN 6"
L METAL FLASHING TURN UP
1/2" @ BACK EDGE OF DOOR
RIM JOIST RE: STRUCT.
INSULATION RE: SPEC & COVER SHEET
5/8" GWB
T.O. PLYWOOD
RE: SECTIONS / PLANS
INTERIOR
INTERIOR
FINISHED FLOOR RE: PLANS & SPEC
3/4" T&G PLYWOOD RE: STRUCT.
WOOD I-JOISTS RE: STRUCT.
DOOR RE: WINDOW SCHED.
TYPICAL VERTICAL WOOD SIDING
WALL ASSEMBLY PER 2/A6.7
1" STEP
GRID
LINE
EXTERIOR
EXTERIOR
2X SLEEPERS @ 24" O.C. W/ TOP
RIPPED TO 1/8" PER 1'-0". RE: FLOOR
PLANS FOR SLOPE DIRECTION
3/4" PLYWOOD SLOPED AT 1/8" PER 1'-0"
W.P. MEMBRANE RE: SPEC
DRAINAGE BOARD SLOPES AT
1/8" PER 1'-0" RE: SPEC
4" STONE ASSEMBLY- APPROX 2" OF
STONE OVER 1/2" OF GROUT OVER 1 1/2"
CONC. SLAB WITH RADIANT TUBING
DECK JOISTS RE: STRUCT.
PLYWOOD RE: STRUCT. 11 7/8"
CONT. BUG SCREEN WRAPPED OVER
AIR VENT MATERIAL TO CREATE MIN
1/2" VENT AT TOP OF THE WALL.
RIM JOIST RE: STRUCT.
1X T&G DECKING
DOOR SILL SET IN BED OF SEALANT
PFSM FLASHING RE: SPEC - TURN UP
WALL AND UNDER WINDOW/ DOOR SILL
W.P. MEMBRANE CONTINUOUS UNDER
DOOR SILL LAP OVER L METAL AND
CONTINUE DOWN WALL & LAP OVER CONC
FOUNDATION W.P. MEMBRANE MIN 6"
L METAL FLASHING TURN UP
1/2" @ BACK EDGE OF DOOR
INTERIOR
EXTERIOR
GRID
LINE
GRID
LINE
WINDOW RE: WINDOW SCHEDULE
FILL W/ EXPANDING SPRAY FOAM
INSULATION AND SHIM
SEALANT JOINT AND BACKER ROD
PROVIDE CAULK JOINT BETWEEN
WINDOW FRAME AND R.O. @
INTERIOR TYP.
WOOD SIDING. RE: ELEVATIONS &
DETAILS ON A6.7
SEE 2/A8.1 FOR TYP. WINDOW
JAMB INSTALL & WATERPROOFING
CORNER POST RE: STRUCT.
DRYWALL WRAP W/ J-MOLDING
AND SEALANT JOINT
8 1/2"
8 1/2"
SLIDING PATIO DOOR RE: WINDOW SCHEDULE
INTERIOR
US Mail Only: P. O. Box 2378
Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Scale
Date
Drawn by
Checked by
Issue Date 3/23/2017 1:12:11 PM
3" = 1'-0"
LILES RESIDENCE
2440 CHAMONIX LANE
VAIL, CO 81657
A8.3
WINDOW &
DOOR
DETAILS
3-23-2017
CPM
HB
3-23-2017
PERMIT SET
3" = 1'-0"
3
GARAGE DOOR JAMB DETAIL @ STONE
VENEER
3" = 1'-0"
2
SLIDING DOOR SILL DETAIL @ MAIN
LEVEL DECK
3" = 1'-0"
1
SLIDING DOOR SILL DETAIL @ UPPER
LEVEL DECK
3" = 1'-0"
4 INSIDE WINDOW CORNER DETAIL
REVISION SCHEDULE
# DESCRIPTION DATE
04/28/17