Loading...
HomeMy WebLinkAboutB17-0053_A8.3_1493402477.pdfGARAGE DOOR AND TRACK PER SPECIFICATIONS 1 X 6 TRIM R.O. 1 X 8 WITH KERF CUT BACK GARAGE DOOR TRACK 1/4" SEALANT JOINT AND BACKER ROD GRID LINE 7 1/2" 5 1/2" TYPICAL INTERIOR TRIM RE: SPEC. PROVIDE WEATHER STRIPPING ON ALL 4 SIDES *NOTE - PROVIDE BLOCKING BEHIND DRYWALL AS REQ'D FOR ATTACHMENT OF GARAGE DOOR HARDWARE. NO EXPOSED 2X BLOCKING MAY BE UTILIZED INTERIOR EXTERIOR HSS COLUMN RE: STRUCT. STONE VENEER WALL ASSEMBLY PER 4/A6.7 7/8" FINISHED FLOOR RE: PLANS 3/4" T&G PLYWOOD RE: STRUCT. 14" WOOD I-JOISTS RE: STRUCT. INSULATION RE: SPEC & COVER SHEET FINISH RE: RCP T.O. PLYWOOD RE: SECTIONS / PLANS INTERIOR INTERIOR EXTERIOR GRID LINE WOOD JOISTS RE: STRUCT 3X6 DRIP THROUGH DECKING T.O. DECKING RE: SECTIONS / PLANS CONT. BUG SCREEN STAPLED TO LEDGER WRAPPED OVER AIR VENT MATERIAL TO CREATE MIN 1/2" VENT AT TOP OF THE WALL. 7 1/4" 1" STEP DOOR SILL SET IN BED OF SEALANT PFSM FLASHING RE: SPEC - TURN UP WALL AND UNDER WINDOW/ DOOR SILL W.P. MEMBRANE CONTINUOUS UNDER DOOR SILL LAP OVER L METAL AND CONTINUE DOWN WALL & LAP OVER CONC FOUNDATION W.P. MEMBRANE MIN 6" L METAL FLASHING TURN UP 1/2" @ BACK EDGE OF DOOR RIM JOIST RE: STRUCT. INSULATION RE: SPEC & COVER SHEET 5/8" GWB T.O. PLYWOOD RE: SECTIONS / PLANS INTERIOR INTERIOR FINISHED FLOOR RE: PLANS & SPEC 3/4" T&G PLYWOOD RE: STRUCT. WOOD I-JOISTS RE: STRUCT. DOOR RE: WINDOW SCHED. TYPICAL VERTICAL WOOD SIDING WALL ASSEMBLY PER 2/A6.7 1" STEP GRID LINE EXTERIOR EXTERIOR 2X SLEEPERS @ 24" O.C. W/ TOP RIPPED TO 1/8" PER 1'-0". RE: FLOOR PLANS FOR SLOPE DIRECTION 3/4" PLYWOOD SLOPED AT 1/8" PER 1'-0" W.P. MEMBRANE RE: SPEC DRAINAGE BOARD SLOPES AT 1/8" PER 1'-0" RE: SPEC 4" STONE ASSEMBLY- APPROX 2" OF STONE OVER 1/2" OF GROUT OVER 1 1/2" CONC. SLAB WITH RADIANT TUBING DECK JOISTS RE: STRUCT. PLYWOOD RE: STRUCT. 11 7/8" CONT. BUG SCREEN WRAPPED OVER AIR VENT MATERIAL TO CREATE MIN 1/2" VENT AT TOP OF THE WALL. RIM JOIST RE: STRUCT. 1X T&G DECKING DOOR SILL SET IN BED OF SEALANT PFSM FLASHING RE: SPEC - TURN UP WALL AND UNDER WINDOW/ DOOR SILL W.P. MEMBRANE CONTINUOUS UNDER DOOR SILL LAP OVER L METAL AND CONTINUE DOWN WALL & LAP OVER CONC FOUNDATION W.P. MEMBRANE MIN 6" L METAL FLASHING TURN UP 1/2" @ BACK EDGE OF DOOR INTERIOR EXTERIOR GRID LINE GRID LINE WINDOW RE: WINDOW SCHEDULE FILL W/ EXPANDING SPRAY FOAM INSULATION AND SHIM SEALANT JOINT AND BACKER ROD PROVIDE CAULK JOINT BETWEEN WINDOW FRAME AND R.O. @ INTERIOR TYP. WOOD SIDING. RE: ELEVATIONS & DETAILS ON A6.7 SEE 2/A8.1 FOR TYP. WINDOW JAMB INSTALL & WATERPROOFING CORNER POST RE: STRUCT. DRYWALL WRAP W/ J-MOLDING AND SEALANT JOINT 8 1/2" 8 1/2" SLIDING PATIO DOOR RE: WINDOW SCHEDULE INTERIOR US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Scale Date Drawn by Checked by Issue Date 3/23/2017 1:12:11 PM 3" = 1'-0" LILES RESIDENCE 2440 CHAMONIX LANE VAIL, CO 81657 A8.3 WINDOW & DOOR DETAILS 3-23-2017 CPM HB 3-23-2017 PERMIT SET 3" = 1'-0" 3 GARAGE DOOR JAMB DETAIL @ STONE VENEER 3" = 1'-0" 2 SLIDING DOOR SILL DETAIL @ MAIN LEVEL DECK 3" = 1'-0" 1 SLIDING DOOR SILL DETAIL @ UPPER LEVEL DECK 3" = 1'-0" 4 INSIDE WINDOW CORNER DETAIL REVISION SCHEDULE # DESCRIPTION DATE 04/28/17