B17-0053_Load Calc_1493402507.pdf
A-Phase Electric, LLC 2440 Chamonix Lane Vail, CO Load Calculation General Lighting and Receptacle Demand Load: 6453 sq. ft. x 3VA = 19359 1,500 VA x 2= 3000 1,500 VA x 1 = 1500 Total connected load: 23,859 3,000 VA @ 100% = 3,000 VA @ 35% = 7,300.7 2555.23 Total general lighting and Receptacle demand load: 5,555 Range demand load: 12,000VA 8,000 Dryer Load: 5,000 Fixed appliance load: Dishwasher 1 1,200 Garbage disposal 1 800 microwave 1 1,200 UC refrigerator 1 1,200 humidifier 1 1,200 ERV 1 1,200 wine chiller 1 1,200 steam shower 1 12,000 subtotal 20,000 demand factor -25% 5,000 Total fixed appliance load: 15,000 Heating load: heat tape 1 5000 fan coil 3 1200 3600 A/C condenser 1 4000 4000 boiler and pumps 1 2000 2,000 Total heating load: 14,600 www.aphaseelectricllc.com 04/28/17 A-Phase Electric, LLC 2440 Chamonix Lane Vail, CO Load Calculation 25% of largest motor: 200 Totals: General lighting and receptacles: 5,555 Range: 8,000 Dryer: 5,000 Fixed appliance: 15,000 Heating: 14,600 25% of largest motor: 200 Total: VA 48,355 AMPS 201.48 Proposed Service Size: 320A single phase x www.aphaseelectricllc.com 04/28/17 A-Phase Electric, LLC 2440 Chamonix Lane Vail, CO Load Calculation x www.aphaseelectricllc.com 04/28/17