Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
DRB140145_DRB140145 Product Information_1399668840.pdf
All American Heating, Inc. Po Box 7399-235 Office 970-406-1352 Breckenridge, Co 80424 Fax 970-453-2829 Alder Jay & Margge 5020 Main Gore PI Unit F-2 Vail, Co 81657 Phone: 719-210-3182 Email: Almondring@msn.com The following proposal submitted by All American Heating, Inc. at the above said address is to include all materials and labor as noted for a complete installation. 1. ption 1: Rheem M#RGJF Prestige,series communicating modulating Horizontal forced air furnace with ECM blower and contour comfort control. 91% AFUE 45,000 Btu's-100,000 Btu's. 2. Option 2: Rheem R-96V Prestige series communicating 2 stage variable speed Horizontal forced air furnace with ECM blower. 96% AFUE 68,000 Btu's low fire 98,000 Btu's high fire. 3. Option 3: Rheem R-96P Prestige series 2 stage Horizontal forced air furnace with multi speed blower.95% AFUE 68,000 Btu's low fire 98,000 Btu's high fire. 4. Option 4: Rheem R-95P Prestige series 1 stage Horizontal forced air furnace with multi speed blower.95% AFUE 98,000 Btu's high fire. 5. New supply and return air plenums with filter rack and all furnace,duct work hanging materials. 6. Insulated duct system (R-4,6,8)with 14 supply outlets and 2-4 return air ducts with registers. Combination duct system. Supply registers will be white and/or brown w/damper.Soffits and/or drywall by others. Includes job design&site review with client and/or contractor. 7. New black iron gas line with 5 outlets. Includes pressure test. 8. New low voltage wiring,sensors and programming. Licensed electrician required. By others. 9. High altitude kit and any required gas orifices. 10. Required Carbon monoxide detectors for home. 11. Condensate pump,condensate drain lines with neutralizer to existing drain. 12. Install new digital thermostat.Communicating thermostat with option 1 only. 13. New PVC vents system to exterior sidewall and/or roof. 14. Permit Fee's and required inspections. 15. Test and balance system for proper operation. 16. Taxes, Labor,Cleanup and Disposal of existing equipment. 17. Yearly maintenance contract with 1 visit. 18. Warranty on Rheem furnace: 10 year parts&20 year heat exchanger warranty. 19. All American Heating Warranty 2 Years parts and labor. Lifetime workmanship warranty. Furnace Total price(Option 1): Mod 91% AFUE $ 16,647.00 Total price(Option 2): 2 stage 96% AFUE $ 15,868.00 t•--) Total price(Option 3): 2 stage 96% AFUE $ 15,142.00 Total price(Option 4): 1 stage 95% AFUE $ 14,833.00 Water-Heaters C.--Rheem _ _- (Rheem Tankless water heater 94% 199k with plumbing kit,venting and relocation each $ 4,982.IA, Rinnai Tankless water heater 82% 199k with plumbing kit,venting and relocation each $ 4,437.00 9� Electric 80 gallon water heater with mixing valve,insulation cover& relocation $ 2,087.00 Electric 2-40 gallon low boy water heaters w/mixing valve, insulation cover& relocation $ 2,265.00 ILLANzucel Project SummaryJob: Jf41414vail Date: Apr 14,2014 Entire House By: John Fulling - ""i All American Heating 400 North Park Ave#10-B, Breckenridge,Co 80424 Phone:970-453-6640 Fax:970-453-2829 Email:Johnfulling©yahoo.com Web:www.AllAmericanHeatinglnc.com Pro'ect Information +: For: Jay & Margge Adler 5020 Mian Gore Place Unit F-2, Vail, co 81657 Phone: 719-210-3182 Email:Almondring@msn.com Notes: New furnace with ductwork. • Desi• n Information ,5'. Weather: Leadville, CO, US Winter Design Conditions Summer Design Conditions Outside db -17 °F Outside db 81 °F Inside db 70 °F Inside db 75 °F Design TD 87 °F Design TD 6 °F Daily range H Relative humidity 50 Moisture difference -61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 45379 Btuh Structure 7035 Btuh Ducts 6210 Btuh Ducts 3385 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 51589 Btuh Use manufacturer's data n Rate/swing multiplier 0.86 Infiltration Equipment sensible load 8961 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure -1635 Btuh Ducts -212 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area (ft2) 1689 1422 Equipment latent load 0 Btuh Volume (ft3) 13512 11376 Air changes/hour 0.59 0.30 Equipment total load 8961 Btuh Equiv.AVF (cfm) 133 57 Req. total capacity at 0.70 SHR 1.1 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trade Trade Model Cond AHRI ref Coil AHRI ref Efficiency 80 AFUE Efficiency 0 SEER Heating input 0 MBtuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Low output baseboard 500 Btuh/ft Total coding 0 Btuh Total low baseboard 103 ft Actual air flow 628 cfm High output baseboard 700 Btuh/ft Air flow factor 0.060 cfm/Btuh Total high baseboard 74 ft Static pressure 0 in H2O Space thermostat Load sensible heat ratio 1.00 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2014-Apr-14 14:02:52 Wrightsoft Right-Suite@ Universal 2012 12.1.08 RSU19569 Page 1 ACCP. ...oad Calcs 2013\Jay and Margge Adler 4 14 14.rup Calc=MJ8 Building Front faces: N xamarucW Load Short Form Job: Jf41414vail F :::cc .v Date: Apr 14,2014 i ti ,.. Entire House By: John Fulling Cc All American Heating 400 North Park Ave#10-B, Breckenridge, Co 80424 Phone:970-453-6640 Fax:970-453-2829 Email:Johnfulling@yahoo.com Web:www.AllAmericanHeatingInc.com Project Information :' For: Jay & Margge Adler 5020 Mian Gore Place Unit F-2, Vail, co 81657 Phone: 719-210-3182 Email:Almondring@msn.com Design Information Htg Clg Infiltration Outside db(°F) -17 81 Method Simplified Inside db(°F) 70 75 Construction quality Average Design TD (°F) 87 6 Fireplaces 1 (Average) Daily range - H Inside humidity (%) 50 50 Moisture difference (gr/Ib) 77 -61 HEATING EQUIPMENT COOLING EQUIPMENT Make Make Trade Trade Model Cond AHRI ref Coil AHRI ref Efficiency 80 AFUE Efficiency 0 SEER Heating input 0 MBtuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Low output baseboard 500 Btuh/ft Total coding 0 Btuh Total low baseboard 103 ft Actual air flow 628 cfm High output baseboard 700 Btuh/ft Air flow factor 0.060 cfm/Btuh Total high baseboard 74 ft Static pressure 0 in H2O Space thermostat Load sensible heat ratio 1.00 ROOM NAME Area Htg load Clg load Baseboard (ft) Clg AVF (ft2) (Btuh) (Btuh) Low High (cfm) Living Room 780 18890 5492 38 27 331 Bath 45 1204 112 2 2 7 Office 117 4981 0 10 7 0 Closet 15 1345 0 3 2 0 Chase 9 682 0 1 1 0 Bedroom 2 196 6471 3015 13 9 182 Guest Bath 25 1512 243 3 2 15 Mast closet 25 581 83 1 1 5 Toilet 15 39 21 0 0 1 Master Bath 120 2787 399 6 4 24 Master Bed 192 6591 1055 13 9 64 Bedroom 3 150 6507 0 13 9 0 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2014-Apr-14 14:02:52 wri htSOf ` Right-Suite®Universal 2012 12.1.08 RSU19569 Page 1 ACCA ..oad Calcs 2013\Jay and Margge Adler 4 14 14.rup Calc=MJ8 Building Front faces: N Entire House 1689 51589 10420 103 74 628 Other equip loads 0 0 Equip. @ 0.86 RSM 8961 Latent cooling 0 TOTALS 1689 51589 8961 103 74 628 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft 2014-Apr-1414:02:52 9 Right-Suite®Universal 2012 12.1.08 RSU19569 Page 2 ACCA ...oad Calcs 2013\Jay and Margge Adler 4 14 14.rup Calc=MJ8 Building Front faces: N ja... "" Building Analysis Job: Jf41414vail F. Date: Apr 14,2014 I 1:'-:- Entire House By: John Fulling .1.".. All American Heating 400 North Park Ave#10-B, Breckenridge, Co 80424 Phone:970-453-6640 Fax:970-453-2829 Email:Johnfulling@yahoo.com Web:www.AllAmericanHeatinglnc.com Pro'ect Information r For: Jay & Margge Adler 5020 Mian Gore Place Unit F-2, Vail, co 81657 Phone: 719-210-3182 Email:Almondring@msn.com Desi• n Conditions Location: Indoor: Heating Cooling Leadville, CO, US Indoor temperature(°F) 70 75 Elevation: 9941 ft Design TD (°F) 87 6 Latitude: 39°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 77.4 -61.3 Dry bulb(°F) -17 81 Infiltration: Daily range(°F) - 30 ( H ) Method Simplified Wet bulbg(°F) - 51 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 1 (Average) Heatin • , Component Btuh/ft2 Btuh % of load Walls 7.4 17095 33.1 Glazing 49.4 3460 6.7 Doors 33.9 9738 18.9 Ceilings 2.8 2896 5.6 °° Floors 3.3 3444 6.7 Infiltration 3.4 8747 17.0 Ducts 6210 12.0 Piping 0 0 ,°w,. Humidification 0 0 Ventilation 0 0 Adjustments 0 Total 51589 100.0 Coolin • Component Btuh/ft2 Btuh % of load Walls 0.5 1102 10.6 WIllnll ,,,,, Glazing 46.9 3290 31.6 Doors 4.2 1194 11.5 Ceilings 1.0 980 9.4 Floors 0.2 211 2.0 ' Infiltration 0.1 259 2.5 Ducts 3385 32.5 °""'- Ventilation 0 0 Internal gains 0 0 Blower 0 0 4fY 11.w. Adjustments 0 Total 10420 100.0 Latent Cooling Load = 0 Btuh Overall U-value= 0.094 Btuh/ft2-°F WARNING: window to floor area ratio= 4.1% - less than 5%. Bold/italic values have been manually overridden 2014-Apr-14 14:02:52 wrightsoft Right-Suite°Universal 2012 12.1.08 RSU19569 Page 1 ACCP ...oad Calcs 2013\Jay and Margge Adler 4 14 14.rup Calc=MJ8 Building Front faces: N Gas Furnaces _Dr, Air RGJF Series 14eeql The new degree of comfort" Rheem Prestige Series' Modulating Horizontal Gas Furnace equipped with the Comfort Control2 System RGJF- Series Up to 94.8% A.F.U.E.t Input Rates from 60 to 120 kBTU [17.58 to 35.16 kW] With Contour Comfort Control® tA.F.U.E.(Annual Fuel Utilization Efficiency)calculated in accordance with - - - Department of Energy test procedures. , gel • The Rheem Prestige Series'"High Efficiency line of horizontal • Reduced firing rates,electrically efficient ECM2+motor,and gas furnaces are designed for utility rooms,closets,or solid doors provide the ultimate in quiet operation. alcoves,attics or crawl spaces.The design is certified by CSA. • Low speed constant fan. • The Comfort Control2 System"provides over 28 on-board • Constant temperature rise for superior comfort. diagnostics and fault history codes by detecting system and electrical problems. "Call for Service"alert notification is sent • Dual Seven segment LED for system diagnostics. to the thermostat to alert the homeowner of required service. • Diagnostic history for troubleshooting. • Serial Communication Enhanced-When installed with a Serial • Two-speed induced draft motor. Communicating Condensing Unit and user interface control • Direct spark ignition with remote sense. (RHC-TST550CMMS)500 Series thermostat this unit offers 4 or • Top electrical connections. 2 wire installation,auto-configuration,and diagnostic messag- ing with full communicating capability. • Optional indoor or outdoor combustion air. • Heat exchanger is constructed of all stainless steel for maxi- • All models comply with Department of Energy test procedures mum corrosion resistance and thermal fatigue reliability. for 2%or less electrical efficiency ratings. • Modulating Function:when used with a modulating thermostat, • A variety of cooling coils and plenums designed to use with modulation rate between 40%and 100%of total capacity. the Rheem Prestige Series''gas furnaces are available as • Two-stage Function:when used with a two-stage thermostat, optional accessories. furnace operates at 40%on first stage,and stages up to 65%, then 100%for second stage. • Multistage Function:when used with a single-stage thermo- stat,furnace functions as a three stage furnace operating at 40%,65%and 100%of total capacity. INTEGRATED HOME COMFORT FORM NO.G11-529 Air Table of Contents "O RGJF Series TABLE OF CONTENTS Standard&Optional Equipment 3 Model Features 4 Physical Data&Specifications 5 Model Number Identification 6 Dimensional Data 7 Blower Performance Data 8 Accessories 9 Limited Warranty 10 2M INTEGRATED HOME COMFORT Air Standard&Optional Equipment RGJF Series PRESSURE L.,0 1 , + INTEGRATED GAS VALVE SWITCHES " FURNACE An I ;" — �i d:•M CONTROL dr'"' S1 II ".i •P", Ami ` . t .�„n _ (HH FUEL CODE) DRAFT -. ,• INDUCER .,,� ------ • ..ma�( h_ a / Wit_ ,, :z: " ..„ h BLOWER ASSEMBLY .� i ? WITH ELECTRONIC _ ii = j COMMUTATED MOTOR (— 'ads J REMOTE I SENSOR �i ar .',.4' �% +, a N mt ay / ` j rP�- a ..,... % J. r� PRIMARY AND SECONDARY k, t .d, elk- �. HEAT EXCHANGER IN-SHOT BURNERS DIRECT SPARK IGNITION STANDARD EQUIPMENT OPTIONAL EQUIPMENT Completely assembled and wired;heat exchanger; primary: NOTE: Furnace is not listed for use with fuels other than natural 409 and aluminized 409 stainless steel,secondary:29-4C or L.P.(propane)gas. stainless steel;induced draft;pressure switches;redundant All models can be converted by a qualified distributor or local modulating main gas control;blower compartment door safety service dealer to use L.P.(propane)gas without changing switch;solid state time on/off blower control;limit controls; burners. Factory approved kits must manual shut-off valve;100% safety lock out;cool fan off delay; be used to convert from natural to L.P.(propane)gas and may one hour automatic retry;power and self-test diagnostics; be ordered as optional accessories from a parts distributor. flame sense current diagnostics;electronic air cleaner For L.P.(propane)operation,refer to Conversion Kit Index Form. connections;humidifier connections;humidifier on/off delay, Fossil Fuel Kits for use with heat pumps. dehumidification connection;low speed continuous fan option; transformer;direct drive, ECM variable speed blower motor. (Please note:a thermostat is not included as standard WARNING equipment.See"Accessories"). THIS FURNACE IS NOT APPROVED OR RECOMMENDED FOR USE IN MOBILE HOMES .w,.`. INTEGRATED HOME COMFORT 3 Air Model Features =2.0RGJF Series The Comfort Control2 SystemTM Features: •The Rheem Dual 7-Segment LED Display easily shows •The fault recall feature will allow for the last six fault- system operating status codes and diagnostic codes. codes to be displayed,and will retain these codes even if •The Status Indication power failure occurs. System Diagnostics ." ■In order to save time and money,replacement automotive feature thermostat com- style fuses can be utilized instead of replacing the entire munication capability and 1 , ,: control board. built-in diagnostics.The . , III 'e thermostat communication The -444 M •o Problem-Solving Accuracy capability and alerts the �•:: • i , • 1� 1 homeowner to anyneces- `' w 100% .y sary service requirements. i��I ' t00% Faster,more accurate ser- ; -j 80% -- 92% � - ^• vice is provided by the built- in diagnostics,by providing the HVAC professional with dependable information. 00% 8 p No Diagnostics 40% ■Rheem Comfort Control'System 20% r77 .'. % 0% Entry Level Experienced Model Features: • The Comfort Control2 System TM provides over 28 on-board • Reduced firing rates,electrically efficient ECM2+motor,and diagnostics and fault history codes by detecting system and solid doors provide the ultimate in quiet operation. electrical problems. "Call for Service"alert notification is sent • Low speed constant fan. to the thermostat to alert the homeowner of required service. • Constant temperature rise for superior comfort. • Serial Communication Enhanced-When installed with a Serial Communicating Condensing Unit and user interface control • Dual Seven segment LED for system diagnostics. (RHC-TST550CMMS)500 Series thermostat this unit offers 4 or • Diagnostic history for troubleshooting. 2 wire installation,auto-configuration,and diagnostic messag- • Two-speed induced draft motor. ing with full communicating capability. • Direct spark ignition with remote sense. • Heat exchanger is constructed of all stainless steel for maxi- • Top electrical connections. mum corrosion resistance and thermal fatigue reliability. • Modulating Function:when used with a modulating thermostat, • Optional indoor or outdoor combustion air. modulation rate between 40%and 100%of total capacity. • All models comply with Department of Energy test procedures • Two-stage Function:when used with a two-stage thermostat, for 2%or less electrical efficiency ratings. furnace operates at 40%on first stage,and stages up to 65%, • A variety of cooling coils and plenums designed to use with then 100%for second stage. the Rheem Prestige Series'gas furnaces are available as • Multistage Function:when used with a single-stage thermo optional accessories. stat,furnace functions as a three stage furnace operating at 40%,65%and 100%of total capacity. 4 INTEGRATED HOME COMFORT �� Air Physical Data&Specifications RGJF Series Physical Data and Specifications-Horizontal Models MODEL NUMBERS RGJF-06EMCK RGJF-07EMCK RGJF-09EZCM RGJF-10EZCM RGJF-12ERCM INPUT-MAXIMUM(BTU/HR)[kW] 60,000[17.58] 75,000[21.98] 90,000[26.38] 105,000[30.77] 120,000[35.17] HEATING CAPACITY-MAXIMUM[kW] 54,720[16.03] 69,000[20.22] 83,160[24.37] 95,865[28.09] 110,880[32.49] INPUT-MINIMUM(BTU/HR)[kW] 24,000 [7.03] 30,000 [8.79] 36,000[10.55] 42,000[12.31] 48,000[14.07] HEATING CAPACITY-MINIMUM[kW] 21,888 [6.41] 27,600 [8.09] 33,264 [9.75] 38,346[11.24] 44,352[12.99] HEATING EXT.STATIC PRESSURE[kPa] 0.12[029] _ 0.12[.029] 0.15[.037] 0.20[.049] 0.20[049] BLOWER(D X WIN.)[mm] 11 x 7[279 x 178] 11 x 7[279 x 178] 12 x 11 [305 x 279] 12 x 11 [305 x 279] 11 x 10[279 x 254] ECM MOTOR HP[W] 1/2[373] 1/2[373] 1 [746] 1 [746] 1 [746) UNIT AMPS 8.7 8.7 12.0 12.0 12.0 MAXIMUM OVERCURRENT PROTECTION 15 15 15 15 15 HEATING CFM-MAXIMUM[L/s] 795[375] 995[470] 1195[564] 1395[658] 1595[753] HEATING CFM-MINIMUM[Us] 320[151] 430[203] 515[243] 600[283] 685[323] COOLING CFM-RANGE[Us] 600-1200[283-566] 600-1200[283-566] 1200-2000[566-944] 1200-2000[566-944] 1200-2000[566-944] MAXIMUM EXT.STATIC PRESSURE[kPa] 0.80[0.20] 0.80[0.20] 0.80[0.20] 0.80[0.20] 0.80[0.20] TEMPERATURE RISE RANGE°F[°C] 40-70[22.2-38.9] 40-70[22.2-38.9] 40-70[22.2-38.9] 40-70[22.2-38.9] 40-70[22.2-38.9] MAX OUTLET AIR TEMPERATURE°F[°C] 180[82.2] 180[82.2] 180[82.2] 190[87.8] 195[90.6] RETURN AIR CABINETS-RXGR- C17B C17B C21B C21B C24B FILTER SIZE(IN.)[mm]BOTTOM 153/4 x 25[400 x 635] 153/4 x 25[400 x 635] 191/4 x 25[489 x 635] 191/4 x 25[489 x 635] 223/4 x 25[578 x 635] FILTER SIZE(IN.)[mm]SIDE 153/4 x 25[400 x 635] 153/4 x 25[400 x 635] 153/4 x 25[400 x 635] 153/4 x 25[400 x 635] 153/4 x 25[400 x 635] APPROX.SHIPPING WEIGHT(LBS.)[kg] 127[57.6] 133[60.3] 158[71.7) 162[73.5] 170[77.1] AFUE 94.8 93.1 90.2 90.4 91.6 [ ]Designates Metric Conversions INTEGRATED HOME COMFORT 5 - Air Model Number Identification —D RGJF Series Model Number Identification R G JF — 07E M C K S Option 278 Rheem Gas Horizontal Design Series Heating Input Blower Size Variations Heat/Cool Fuel Code 278=Factory- Furnace Modulating F= Designation M=11 x 7 C=Single/ Designation S=U.S.or Supplied High Prestige Communicating [279 x 178 mm] Multi K=600-1200 CFM Canadian Altitude Conversion Electric Series"' R =11 x 10 Zone [283-566 Us] Natural Gas Kit(Not Required 90 Plus Electric Ignition— Input [279 x 254 mm] M=1200-2000 CFM on 60K BTU Model) Ignition NOx BTU/HR Gas Furnace Z 1 06E Models 60,000[17.6 kW] [05 x279 mm] [566 944 Us] 07E 06N 75,000[22.0 kW] 09E 07N 90,000[26.4 kW] 10E 09N 105,000[30.7 kW] 12E 10N 120,000[35.2 kW] 12N [ ]Designates Metric Conversions 6 = INTEGRATED HOME COMFORT Dimensional Data -0 Air RGJF Series E 'm E Illustration '.. m o 1 A084901.S01A o I Illustration A084901.S01B O. O. wa co a LL N W J • Tn A IJ 3 a, .-. -IV m 1 L •Z N3 Ih ]• mci ON Ir §'?3 v3 Zi z 0 I rO OmZ II � \I ' S ¢ O W LL U U Qilk F .F 0 NN A -. I/I MIENIMMEN , ¢ IN NM lick 34� E I n"'im pE sE 3T ' .. `�''? m wZ •mo 3 - o ^.o cnao W U .2_, CM o m w m w N A m 3.. 3Lii_____ 3 3 m 3, ;1 W •it • .II 1 o •, -IS./ , .,1 1 T I Zo� T m� T —. � CO 0 Z 4, . "is) 0 C70 m D 1 --Ia �'ro $;ro m< Z Z 0 m.—. -•a rnN j 3m 1 O� 55 D 3 OD 3 3 ,-.1 N o 3 - 3m z 3 w• �' o] W ! 3 v 371 I N Illustration Illustration 4084901.S018 A084901.S01D 3 MINIMUM CLEARANCE(IN.)[mm] MODEL B C D E F LEFT RIGHT RGJF- SIDE SIDE BACK TOP FRONT VENT 06 171/2[445] 1611/32[415] 155/8 [397] 2[51] 165/8[422] 137/8[352] 0 0 0 1 [25] 2[51] 0 07 171/2[445] 1611/32[415] 155/8 [397] 2[51] 165/s[422] 137/8[352] 0 0 0 1 [25] 2[51] 0 09 21 [533] 1927/32[504] 193/16[487] 2[51] 201/8[511] 173/8[441] 0 0 0 1 [25] 2[51] 0 10 21 [533] 1927/32[504] 193/16[487] 2[51] 201/8[511] 173/8[441] 0 0 0 1 [25] 2[51] 0 12 241/2[622] 2311/32[593] 225/8 [575] 2[51] 235/8[600] 207/s[530] 0 0 0 ` 1 [25] 2[51] 0 [ ]Designates Metric Conversions INTEGRATED HOME COMFORT 7 Air Blower Performance Data RGJF Series BLOWER SIZE ICM CFM[L/s1 AIR DELIVERY MODEL (D X W) MOTOR H.P. BLOWER EXTERNAL STATIC PRESSURE RGJF- IN. W) [WI SPEED INCHES WATER COLUMN[kPa] 0.1 [.021-0.8[.201 HIGH 1200[566] 06 11 x 7 1/2 MED-HI 1000[472] [279 x 178] [373] MED 800[378] LOW 600[283] HIGH 1200[566] 07 11 x 7 1/2 MED-HI 1000[472] [279 x 178] [373] MED 800[378] LOW 600[283] HIGH 2000[944] 09 12 x 11 1 MED-HI 1600[755] [305 x 279] [746] MED 1400[661] LOW 1200[566] HIGH 2000[944] 10 12 x 11 1 MED-HI 1600[755] [305 x 279] [746] MED 1400[661] LOW 1200[566] HIGH 2000[944] 12 11 x 10 1 MED-HI 1600[755] [279 x 254] [746] MED 1400[661] LOW 1200[566] [ ]Designates Metric Conversions 8INTEGRATED HOME COMFORT Accessories -0 Air RGJF Series VENT TERMINATION KITS CONCENTRIC: *PROGRAMMABLE THERMOSTAT ACCESSORIES: HORIZONTALNERTICAL = Adapter Plate=F61-2600 Remote F1451328 and F1451378 Sensor RXGY-E03A(US&Canadian Installations) HORIZONTAL TWO PIPE:RXGY-D02,RXGY-D03,RXGY-D04 *Available through PROSTOCK*. (US Installations) RXGY-DO2A,RXGY-DO3A,RXGY-DO4A(Canadian Installations) FOR HIGH ALTITUDES: RGJF HIGH ALTITUDE FIELD CONVERSION KITS: RXGY-G02(US Only) FUEL KIT:Use Modulating Programmable Thermostat MODEL INPUT HIGH ALTITUDE (see below)for Dual Fuel/Fossil Fuel Kits. FIELD CONVERSION KIT NO. HORIZONTAL:RXGY-G02 RGJF 06 60,000 None Needed RGJF-07 75,000 RXGY-F38(8000 ft.and above only) NEUTRALIZER KIT:RXGY-A01 RGJF 09' 90,000 RXGY-F39 PLENUM DATA FOR "A" COILS RGJF-10* 105,000 RXGY-F40 RGJF-12` 120,000 RXGY-F41 Plenum adapters are required in some instances for use on horizontal applications when plenum and furnace size do *5000 ft.&above only(except where noted). not match. OPTION CODE FOR HIGH ALTITUDE:None available.Kit must FURNACE PLENUM PLENUM ADAPTER COIL be ordered. WIDTH WIDTH UPFLOW PLENUM NOTE:High altitude kits do NOT include additional burner orifices. IN.[mm] IN.[mm] 171/2[445] 161/4[413] RXAA-C186 RXAL-B16BU If a burner orifice change is necessary,they must be ordered 171/2[445] 201/4[514] RXAA-C173 RXAL 6206U through PROSTOCK*.See Installation Instructions for more 171/2[445] 215/8[549] RXAA-C187 RXAL-B21 BU information. 171/2[445] 251/4[641] RXAA-C174 RXAL-B25BU CAUTION:Always follow National Fuel Gas Code(NFGC)guidelines 21 [533] 251/4[641] RXAA-C175 RXAL B25BU when converting furnaces for high altitudes. 21 [533] 221/4[565] RXAA-C176 RXAL-B22BU For all installations above 2000 ft.,the burner orifice size must be 21 [533] 215/o[549] RXAA-C188 RXAL-B21 BU recalculated and verified.A burner orifice change may still be 241/2[622] 251/4[641] RXAA C177 RXAL-B25BU required.See Installation Instructions for more information. 241/2[622] 215/8[549] RXAA-C187 RXAL-B21BU Manifold gas pressure reduction methods may NOT be used on these models.The only method permitted on modulating furnace models is LP KIT:(Available through PROSTOCK"°) to recalculate the burner orifice size.See Installation Instructions for U.S./Canadian=RXGJ-FP07 more information. THERMOSTATS [ ]Designates Metric Conversions RECOMMENDED MODULATING FURNACE THERMOSTAT ri 4 Fi wR RHC-TST550CMMS •7 Day 5/1/1 Programmable Modulating/Two Cool Hardwired •Works in Modulating Furnace and Modulating Furnace Dual Fuel applications(requires optional external sensor) •Bright,12 sq.inch touchscreen display •Keypad lockout option •Hardwired •Easy,menu-driven programming •Audio prompting to ensure program change confirmation • Intuitive red/blue temperature keys • Large,easy-to-see characters •Available only through professional contractors INTEGRATED HOME COMFORT 9