HomeMy WebLinkAboutDRB140156_4289 Nugget Lane-deck gfra and site analysis_1405458420.pdf--
-
OTHER HALF OF DUPLEX
3' - 0"
3' - 0"
3'-0" MIN.
13' - 9"
951 SF
MAIN LEVEL
108
1' - 8 3/16"
1' - 7 1/16" 41' - 8 1/8"
GFRA CALCULATION
R-Two-family residential 0.46 of site area < 10,000 sq. ft., plus
TOTAL SF OF THE BUILDING PER 12-15-3: DEFINITION, CALCULATION, AND BASEMENT EXCLUSIONS =2441-851(BASEMENT EXCLUSION) =1590 SF
TOTAL SF OF THE SITE=4343 SF
TOTAL ALLOWABLE GFRA= .46 X 4343=1997.78 SF
TOTAL PROPOSED WITH DECK AND EXTERIOR STORAGE EXTENSION=1627.5 SF
SITE COVERAGE ANALYSIS
-ADDING 42.5 SF OF EXTERIOR 2ND LEVEL DECK.
-ADDING 37.5 SF OF COVERED STORAGE AREA UNDER THE DECK. APPROX 13 SF OF LANDSCAPED AREA WILL BE COVERED WITH CONRETE AND BECOME
PART OF THE STORAGE AREA.
-ADDING 64 SF OF HOT TUB PIT WITH CENTER DRAIN TO DAYLIGHT WILL
SITE COVERAGE. TOTAL ADDITIONAL SITE COVERAGE: 144 SF.
TOTAL EXISTING=1450 SF
TOTAL SITE=4343 SF
TOTAL ALLOWABLE = .46 X 4343=1997.78 SF
TOTAL PROPOSED= 1594 SF OF IMPERVIOUS GROUND
-If building site is within a conventional zone district in unincorporated Eagle County, you can obtain allowable floor area ratio, lot coverage and impervious cover by referencing Eagle
County Land Use Regulations Article 2-Definitions, Floor Area Ratio, Lot Coverage and Impervious Cover or Materials and Article 3 Zone Districts Table 3-340 Schedule of Dimensional
Limitations, Maximum Lot Coverage, Impervious Materials and Maximum Floor Area Ratio.
--
-
-
11' - 0"
4' - 9" 6' - 3"
6' - 0 3/4"
8' - 11 1/2"
8' - 11 1/2"
65 SF
STORAGE
207
957 SF
BASEMENT
208
7' - 0"
18' - 4"
4' - 0"
32' - 7 1/8"
41' - 7 5/8"
9 FT. CEILINGS
SF TO DEDUCT IN BASEMENT
WALL LENGTH X WALL HT. X % UNDERGROUND
19X9=171
4X9=36
7X9=63
32X9=288
42X9X0.75=283.5
TOTAL=841.5 SF
SCALE
PROJECT NUMBER
DATE
DRAWN BY
CHECKED BY
As indicated
A2.1
GFRA & SITE
COVERAGE ANALYSIS
13.07.01
4289 NUGGET LN EAST VAIL, CO 81658
DESIGN DEVELOPMENT
05.29.2014
HDB
HDB
No. Description Date
1/8" = 1'-0"
2
GFRA ANALYSIS PLAN
1/8" = 1'-0" 1
GFRA LOWER LEVEL FLOORPLAN
DRB
APPROVED
7/15/2014 12:00:00 AM