Loading...
HomeMy WebLinkAboutDRB140195_L001_1402503780.pdfGo r e Cr e e k D r i v e Railroad Tie Retaining Wall to be removed (hatched areas) 7930 7935 P r o p e r t y L i n e 31 32 33 3 4 34 34 33 32 31 31 32 33 35 32 31 Existing Trees to be Removed unless specifically note otherwise. Guard Rail This side of the entryway shall consist of railroad tie removal, lighting modification, removal of existing vegetation unless specifically noted otherwise, and smoothing of grades. Contractor shall coordinate with the Landscape Architect for further direction for this area. Existing Light Fixture to be reinstalled: remove the railroad tie base. Existing Grass to Remain Go r e Cr e e k D r i v e 7930 7935 P r o p e r t y L i n e Retaining Wall: Replace the existing railroad tie wall as shown with a Colorado Buff dry-stacked boulder wall. See Detail 301. 31 32 33 3 4 34 34 33 32 31 31 32 33 35 34 33 33 32 32 31 31 30 32 34.3' Guard Rail Site Drainage: Assure positive drainage away from building and to a natural low point Random Boulders: Granite River boulders to be selected by Landscape Architect. Sizes vary (see Schedule). Repair asphalt from the removal of railroad ties as required (both sides). A B B B C C C C D D D D E E E E E E Lighting: Remove railroad tie base from existing fixture and reinstall fixture in the same place. Verify existing wiring and structure: if the existing light doesn't have a concrete base, provide one as required. Landscape Architect to review the condition as it's being demolished. 32.8' 29.5' B B C D A B C D Approx. 61 2' x 8' River Boulder Address Marker 1 3 E Boulder Schedule Qty. Mark Description Approx. 6' River "Random" Boulder 4 Approx. 4' River "Random" Boulder 4 Approx. 3' River "Random" Boulder; one to screen the uplight from view. 6 Approx. 2' River "Random" Boulder Existing Light fixture: remove existing railroad tie base and reinstall in place. 2 Lighting Schedule Qty. Mark Manufacturer 1 Description Model Number B-K Lighting Power Pipe in-ground junction box (low voltage) in Aluminum housing with a Shasta Series fixture with shroud in black finish and spread lens. SH-5-BLP-9,10-A 1303.00 Job No. Issue Date Sheet L001 of three Copyright Fieldscape Incorporated All Rights Reserved This document, and the ideas and designs incorporated herein, as an instrument of professional service, is the property of Fieldscape Incorporated and is not to be used, in whole or in part, for any other project without the written authorization of Ric Fields. c Demolition/Layout/Grading Plan Casa Del Sol Entry Renovation 2065 West Gore Creek Drive, Vail, Colorado North Pricing Feb. 5, '14 North Demolition Plan Layout/Grading Plan T.O.V. June 2, '14 DRB APPROVED 6/11/2014 12:00:00 AM