HomeMy WebLinkAboutDRB140195_L001_1402503780.pdfGo
r
e
Cr
e
e
k
D
r
i
v
e
Railroad Tie Retaining
Wall to be removed
(hatched areas) 7930
7935
P r o p e r t y L i n e
31
32
33
3
4
34
34
33
32
31
31
32
33
35
32
31
Existing Trees to be Removed
unless specifically note otherwise. Guard Rail
This side of the entryway shall consist of railroad
tie removal, lighting modification, removal of
existing vegetation unless specifically noted
otherwise, and smoothing of grades. Contractor
shall coordinate with the Landscape Architect for
further direction for this area.
Existing Light Fixture to
be reinstalled: remove
the railroad tie base.
Existing Grass
to Remain
Go
r
e
Cr
e
e
k
D
r
i
v
e
7930
7935
P r o p e r t y L i n e
Retaining Wall:
Replace the existing railroad tie wall as
shown with a Colorado Buff dry-stacked
boulder wall. See Detail 301.
31
32
33
3
4
34
34
33
32
31
31
32
33
35
34
33
33
32
32
31
31
30
32
34.3'
Guard Rail
Site Drainage:
Assure positive drainage away from
building and to a natural low point
Random Boulders:
Granite River boulders to be selected by
Landscape Architect.
Sizes vary (see Schedule).
Repair asphalt from the removal
of railroad ties as required
(both sides). A
B
B
B
C
C
C
C
D
D
D
D
E
E
E
E
E
E
Lighting:
Remove railroad tie base from existing fixture and reinstall
fixture in the same place. Verify existing wiring and
structure: if the existing light doesn't have a concrete base,
provide one as required. Landscape Architect to review
the condition as it's being demolished.
32.8'
29.5'
B
B
C
D
A
B
C
D
Approx. 61
2' x 8' River Boulder
Address Marker
1
3
E
Boulder Schedule
Qty. Mark Description
Approx. 6' River "Random" Boulder
4
Approx. 4' River "Random" Boulder
4
Approx. 3' River "Random" Boulder;
one to screen the uplight from view.
6
Approx. 2' River "Random" Boulder
Existing Light fixture:
remove existing railroad tie
base and reinstall in place.
2
Lighting Schedule
Qty. Mark Manufacturer
1
Description
Model
Number
B-K Lighting Power Pipe in-ground junction box (low
voltage) in Aluminum housing with a
Shasta Series fixture with shroud in black
finish and spread lens.
SH-5-BLP-9,10-A
1303.00
Job No.
Issue Date
Sheet
L001
of three
Copyright
Fieldscape Incorporated
All Rights Reserved
This document, and the ideas and
designs incorporated herein, as an
instrument of professional service,
is the property of Fieldscape
Incorporated and is not to be used,
in whole or in part, for any other
project without the written
authorization of Ric Fields.
c Demolition/Layout/Grading Plan
Casa Del Sol Entry Renovation
2065 West Gore Creek Drive, Vail, Colorado
North
Pricing Feb. 5, '14
North
Demolition Plan Layout/Grading Plan
T.O.V. June 2, '14
DRB
APPROVED
6/11/2014 12:00:00 AM