Loading...
HomeMy WebLinkAboutDRB140202_A0.00 EM Lot 2_1402336380.pdf ELK MEADOWS RESIDENCES . LOT 2 1626 BUFFEHR CREEK RD VAI L5 CO 81657 MATERIAL SYMBOLS: ABBREVIATIONS: GENERAL NOTES: DRAWING INDEX: GENERAL N /�/. A0.20 COVER 4 -� vp EARTH rz— PLYWOOD ABV ABOVE L LENGTH 1� AFF ABOVE FINISHED FLOOR LDT LIGHT AND DRAPERY TROUGH 01 DO NOT SCALE DRAWINGS TOPOGRAPHIC SURVEY u N N AP ACCESS PANEL LT LIGHT TROUGH ORDENG IH11 �POROUS FILL/DRAINAGE FINISH WOOD AC ACOUSTICAL LTL LINTEL 02 THE VERIFY JOLSTEL DIMENSPROSI ONS,BCONNIDITIONS ANY WORK AND UTILITY R LOCA ITIONS ON C3.2 LOT 2 GRADING PLAN g w -- �i ADD ADDENDUM LVR LOUVER ANY MATERIALS. nOTIFY ARCHITECT OF ANY CONFLICTS OR L1 .21 LOT 2 LANDSCAPE PLAN ADJ ADJACENT MH MANHOLE ALT ALTERNATE MFR MANUFACTURE (ER) DISCREPANCIES IN THE DOCUMENTS IMMEDIATELY. cu ///////// / ALUM ALUMINUM MO MASONRY OPENING 03 AREAS OF CONFLICTS OR DISCREPANCIES MUST BE FULLY /// //// , E // STONE MASONRY WOOD ROUGH// ARCH ARCHITECT (URAL) MTL METAL BSMT BASEMENT MAX MAXIMUM RESOLVED WITH WRITTEN APPROVAL FROM THE ARCHITECT BEFORE DRAWING INDEX: ARCHITECTURAL BRG BEARING MECH MECHANIC (AL) CONSTRUCTION CONTINUES IN THOSE AREAS. STRUCTURAL CONCRETE BLOCKING BVL BEVELED MC MEDICINE CABINET 04 PLAN DIMENSIONS ARE TO FACE OF STUD OR FACE OF CONCRETE, A2.20 GRFA CALC PLANS r' BIT BITUMINUOUS MEM MEMBRANE UNLESS OTHERWISE NOTED.SECTION AND ELEVATION DIMENSIONS ARE A2.21 LOWER LEVEL FLOOR PLAN BLK BLOCK M METER (S) TO TOP OF CONCRETE, TOP OF PLYWOOD, OR TOP OF WALL PLATES OR U Q BLKG BLOCKING MM MILLIMETER BEAMS UNLESS OTHERWISE NOTED. 3 A2.22 UPPER LEVEL FLOOR PLAN CONCRETE MASONRY UNIT GYPSUM BOARD BOT BOTTOM MIN MINIMUM X H 03 Its BLDG BUILDING MIR MIRROR 05 PROVIDE ALL NECESSARY BLOCKING IN STUD WALLS AND CEILINGS. A2.23 ROOF PLAN = CPT CARPET (ED) MISC MISCELLANEOUS LOCATIONS INCLUDE BUT ARE NOT LIMITED TO CEILING AND WALL M 0 v o CSMT CASEMENT MULL MULLION MOUNTED FIXTURES,TOILETS,TOILET ACCESSORIES, CABINETRY, A3.21 ELEVATIONS w o BATT INSULATION C CAULK (ING) NAT NATURAL � < ` 3 CLG CEILING NR NOISE REDUCTION COUNTERTOPS,SHELVES AND CLOSET RODS. � d.� ; A3.22 ELEVATIONS CT CERAMIC TILE NOM NOMINAL CLR CLEAR NIC NOT IN CONTRACT 06 O DENOTES DOORS. REFER TO FLOOR PLANS FOR LOCATIONS. REFER A3.21a BASEMENT CREDIT CALCS RIGID INSULATION TO DOOR SCHEDULE FOR DOOR TYPES. COD CARBON MONOXIDE DETECTOR NTS NOT TO SCALE COL COLUMN OPG OPENING 07 0 DENOTES WINDOWS. REFER TO WINDOWS AND FLOOR PLANS FOR A3.22a BASEMENT CREDIT CALCS CONC CONCRETE OPP OPPOSITE LOCATIONS. REFER TO WINDOW SCHEDULE FOR WINDOW TYPES. CMU CONCRETE MASONRY UNIT OPH OPPOSITE HAND A4.21 MASTER CROSS SECTION 1/ // I STEEL/METAL AS NOTED CONST CONSTRUCTION OH OVERHEAD CONT CONTINUOUS PR PAIR A4.22 ENTRY CROSS SECTION 08 COORDINATE ALL ELECTRICAL AND MECHANICAL FIXTURES TO FIT CJT CONTROL JOINT PK PARKING WITHIN CEILING, FLOOR AND WALLS SPACES. VERIFY LOCATIONS WITH A4.23 LIVING CROSS SECTION CPR COPPER PVMT PAVEMENTCSI CARPET CUST CUSTOM PL PLASTIC LAMINATE ARCHITECT. Iilli II IIIIIIIIIIIIIIIII DT DRAPERY TROUGH PT POINT A4.24 DINING CROSS SECTION DTL DETAIL PSF POUNDS PER SQUARE FOOT 09 IN THE EVENT THAT ADDITIONAL DETAILS OR GUIDANCE IS NEEDED BY A5.21 WINDOW DETAILS DIM DIMENSION PSI POUNDS PER SQUARE INCH THE CONTRACTOR FOR CONSTRUCTION OF ANY ASPECTS OF THIS DR DOOR PL PROPERTY LINE PROJECT,THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE A6.21 EXTERIOR DETAILS IM DRW DRAWING QT QUARRY TILE ARCHITECT. DF DRINKING FOUNTAIN REF REFERENCE A6.22 EXTERIOR DETAILS 1 r 1 ELEC ELECTRIC (AL) REF REFRIGERATOR EL ELEVATION (S) REIN REINFORCE (D), (ING) 10 THE CONTRACTOR SHALL BE RESPONSIBLE FOR SATISFYING ALL A6.23 EXTERIOR DETAILS 0 A4.00 A4.00 APPLICABLE CODES AND OBTAINING ALL PERMITS AND REQUIRED EQ ELEVATOR REQ REQUIRED EQ EQUAL RES RESILIENT APPROVALS. THIS PROJECT IS GOVERNED BY THE INTERNATIONAL EXH EXHAUST REV REVISION (D), (ING) BUILDING CODE, 2003 EDITION. CODE COMPLIANCE IS BUILDING SECTION REFERENCE ELEVATION REFERENCE EXTG EXISTING REV REVERSE MANDATORY.THE CONSTRUCTION DOCUMENTS SHALL NOT PERMIT EXT EXTERIOR RH RIGHT HAND WORK THAT DOES NOT CONFORM TO ALL RELEVANT CODES FOC FACE OF CONCRETE R RISER INCLUDING IBC AND ALL LOCAL AND REGIONAL CODES. DRAWING INDEX: ELECTRICAL FOF FACE OF FINISH R&S ROD AND SHELF Z lin FOM FACE OF MASONRY RD ROOF DRAIN 11 THE CONTRACTOR SHALL FIELD COORDINATE AND OBTAIN E2.21 LOWER LEVEL LIGHTING PLAN 0 1 1 FOS FACE OF STUDS FIN FINISH (ED) RDT RECESSED DRAPERY TRACK RFG ROOFING E2.22 UPPER LEVEL LIGHTING PLAN APPROVAL FROM THE ARCHITECT & ENGINEER BEFORE ANY N 1 A4.00 A4.00 `/ CUTTING, NOTCHING OR DRILLING OF ANY CAST-IN-PLACE > Q FFE FINISHED FLOOR ELEVATION RM ROOM CONCRETE, STEEL FRAMING, OR ANY OTHER STRUCTURAL ELEMENTS FE FIRE EXTINGUISHER RO ROUGH OPENING WHICH MAY AFFECT THE STRUCTURAL INTEGRITY OF THE BUILDING. FDC FIRE DEPARTMENT CONNECTION R/S ROUGH SAWN CO DETAIL REFERENCE DETAIL REFERENCE FHC FIRE HOSE CONNECTION S SEALANT (EXTERIOR) H 0 FEC FIRE EXTINGUISHER CABINET SHTG SHEATHING H1110 o FP FIREPLACE SHH SHOWER HEAD 12 THE CONTRACTOR SHALL VERIFY ALL EXISTING GRADES AND STAKE V MAIN 1 FPS FIREPROOFING, SPRAYED SHC SHOWER CONTROLS OUT THE BUILDING FOOTPRINT FOR OWNER AND ARCHITECT O 100'-0" A4.00 FLG FLASHING SM SHEET METAL APPROVAL PRIOR TO BEGINNING ANY SITE WORK. J FLR FLOOR (ING) SIM SIMILAR 4 0 a FD FLOOR DRAIN SC SOLID CORE 13 IT IS THE INTENT AND MEANING OF THESE DOCUMENTS THAT THE W 4 > HEIGHT REFERENCE FTG FOOTING SPEC SPECIFICATON (S) CONTRACTOR AND EACH SUBCONTRACTOR PROVIDE ALL LABOR, 2 SECTION REFERENCE FND FOUNDATION SQ SQUARE MATERIALS,TRANSPORTATION, SUPPLIES, EQUIPMENT, ETC.TO OBTAIN FBO FURNISHED BY OTHERS STD STANDARD A COMPLETE JOB WITHIN THE RECOGNIZED STANDARDS OF THE j �\ FPHB FREEZE PROOF HOSE BIB ST STAIN INDUSTRY. W FUR FURRED (ING) STL STEEL ROOM NAME GA GAGE, GAUGE SD STORM DRAIN ill GALV GALVANIZED STR STRUCTURAL 14 ALL BUILDINGS TO FIT WITHIN PROPERTY LINES WITHOUT CROSSING GC GENERAL CONTRACT (OR) TEL TELEPHONE EASEMENTS OR SETBACKS. NOTIFY ARCHITECT OF ANY DISCREPANCIES. 2 A GL GLASS, GLAZING TV TELEVISION REVISION REFERENCE ROOM NAME GYP GYPSUM BOARD THR THRESHOLD 15 PROVIDE ACCESS PANEL TO MOTOR FOR ALL WHIRLPOOL-TYPE TUBS. HB HOSE BIB T&G TONGUE AND GROOVE COORDINATE ACCESS LOCATIONS WITH INTERIOR DESIGNER AND HDW HARDWARE TOS TOP OF SLAB ARCHITECT TO PROVIDE INCONSPICUOUS LOCATION. HDR HEADER TOS TOP OF STEEL HTG HEATING TOW TOP OF WALL GRID W11 HVAC HEATING/VENTILATING/AC TB TOWEL BAR HT HEIGHTTR TRANSOM PROJECT SUMMARY: HC HOLLOW CORE T TREAD GRID BUBBLE WALL TYPE REFERENCE HM HOLLOW METAL TYP TYPICAL HOR HORIZONTAL UNO UNLESS NOTED OTHERWISE Code: ILI HWH HOT WATER HEATER VB VAPOR BARRIER International Residential Code 2012 1 INCL INCLUDE (D), (ING) VIF VERIFY IN FIELD Occupancy: One-Family Dwelling ID INSIDE DIAMETER VERT VERTICAL IBC INSTALLED BY CONTRACTOR VCT VINYL COMPOSITION Separations: 4 A8 2 11 IBO INSTALLED BY OWNER WC WATER CLOSET 1 Hour e) 1 Hour (residence/mechanical) INS INSULATE (D), (ION) WP WATER PROOFING 3 INT INTERIOR WWF WELDED WIRE FABRIC JC JANITOR'S CLOSET W WIDTH, WIDE Special Attributes: KIT KITCHEN WDW WINDOW Intelligent Addressable Fire Alarm ISSUED FOR: DATE: INTERIOR ELEVATION REFERENCE WINDOW TAG LAM LAMINATE (D) WO WITHOUT Automatic Sprinkler System SCHEMATIC DESIGN 4.16.14 LAV LAVATORY WD WOOD LH LEFT HAND TOV DRB FINAL REVIEW 6.9.14 ® STN / TILE DOOR TAG MATERIAL BREAK COPY RIGHT RESERVATION The drawings, specifications and other documents prepared by the Architect (Michael Suman Architect, LLC) for this project are instruments of the Architect's service for use solely with respect to this Project and, unless otherwise provided in writing, the Architect shall be deemed the sole and exclusive author of these documents and shall retain,without limitation, all common law, statutory and other reversed rights, including copyright person,co ri ht hereof. No whether C> 2A014 MICHAELRIGHTS SUMANRESERVED.ARCHITECT,LLC. LL having come rightly into possession hereof or otherwise, shall employ these documents on any other project, nor SCALE: ' for additions to this Project nor for the completion of this DRAWN: MDS Project by others, unless with the prior express written OWNER: ARCHITECT: CONTRACTOR: STRUCTURAL ENGINEER: MECH/ELECT. ENGINEER: consent of the Architect and upon appropriate compensation to the Architect in an amount and kind PROJECT#: 1401 Craig and Sharon Cohn SUMAN ARCHITECTS KRM CONSULTANTS, INC RADER ENGINEERING, INC. satisfactory to the Architect. The Architect expressly SHEET TITLE: COVER SHEET 141 Meadow Drive Suite 211 P.O. Box 7760 970.949.9391 P.O. Box 8610 claims all proprietary rights in the material which is issued Vail, Colorado 81657 AVON, COLORADO 81620 CONTACT:Tim Hennum Avon, CO 81620 in confidence for design and/or construction purposes of 970.479.7502 EMAIL: tim@krmconsultants.com (970) 845-7910 this Project as noted. These materials may not be CONTACT: MICHAEL SUMAN (970) 845-7522 FAX copied, modified, nor employed in any way without the EMAIL: michael@sumanarchitects.com CONTACT: BRYAN HOULE specific prior written consent and permission of the EMAIL: bryan@raderengineering.com Architect. AOIOO ©2014 Michael Suman Architect, LLC. All rights reserved.