Loading...
HomeMy WebLinkAboutDRB140202_A4.23 EM Lot 2_1402336380.pdf / / 7 — i 5N ' u inr — n i GENERAL ASSEMPLY NOTES: I ----- _- - -I- ROOF CEILING ASSEMBLY • - •STANDING SEAM METAL ROOF PANELS - - To W.R. GRACE ULTRA HIGH TEMP ROOF MEMBRANE OR EQUAL - -- — - •STRUCTURAL PLYWOOD SHEATHING OVER (RE:STRUCTURAL) I -- -- --- -- - I T • 14"ROOF JOISTS UNLESS NOTED OTHERWISE (RE:STRUCTURAL) • _- - -- - •2"SPRAY FOAM INSULATION AT BOTTOM SIDE OF SHEATHING_R-13 MIN. • - - • 12"BLOWN-IN CELLULOSE INSULATION IN CAVITY_R-45.6 MIN. (R-58.6 TOTAL) - - _- - •2 MIL SMART MEMBRAIN VAPOR RETARDERI - - • lx6 T&G DECKING OR DRYWALL PER REFLECTED CEILING PLANS • - - -- A - • FLOOR CEILING ASSEMBLY -- - - •SEE PLANS FOR FINISH I _- -- - IIV ' • ,� • 1 2'GYP-CRETE WITH RADIANT HEAT LOOPS OVER • - -- -- -- -- - BUILDING HEIGHT LIMIT LINE Ac--.. •3/q' PLYWOOD DECKING OVER - -- A4.21 6k4.22 . 0 - l' c',' ° •STRUCTURAL MEMBERS(RE:STRUCTURAL) _ _ _ _ _ - • BLOWN-IN CELLULOSE INSULATION AT JOIST CAVITIES_R-38 MIN. - - - - - - - - - - - - - - - I .�r� t •SEE RCP'S FOR CEILING FINISH - - - - - -- - - - - - - - - EXPOSED METAL COUNTER • _ _ _ _ _ _ _ _ __ _ _ _ __ _ _ _ _ FLASHING TIED INTO ROOF • • SLAB ON GRADE ASSEMBLY I MEMBRANE COLOR TO I BUILDING ENVELOPE •SEE PLANS FOR FINISH MATCH ROOF PANELS-TYP. LINE TYPICAL FLAT ROOF STRUCTURE •STRUCTURAL CONCRETE SLAB WITH • • • • HYDRONIC HEAT TUBING OVER WITH DECK DR • AINS SEE STRUCTURAL FOR DETAILS • RIGID INSULATION_R-10 MIN. OVER • • 10 MIL POLYETHYLENE VAPOR DIFFUSION RETARDER OVER •4"GRAVEL BALLAST • FRAMED EXTERIOR WALLS 8 - Ct1 1 • 1" BLOWN-IN FOAM INSULATION_R-6.5 MIN. A6.21 �� . • 4.5" BLOWN-IN CELLULOSE INSULATION_R-17 MIN. (R-23.5 TOTAL) • y \ • FOUNDATION WALLS I 'moi II �'7 I IIM • HOTIFLUID APPLIEDWATERPROOFING-OVER N AND DRY BOARD BY MAR-FLEX R-10 OVER • 17II ;T���l����� TTTTTTTMTTMTTTTTT �����������j�j��������I ! ••CONCRETE FOUNDATION WALL (RE:STRUCTURAL) \- / •2x FURRING AND INSULATION PER PLAN ON INTERIOR_R-10 MINIMUM I II . I 0 FRAMED INTERIOR PARTITION WALLS • BLOWN-IN CELLULOSE INSULATION _ • CONDITIONED CRAWLSPACE WALLS I SEE INTERIOR DETAILS 2 • CONTINUOUS DRAIN AND DRY BOARD BY MAR-FLEXR-10 AT EXTERIOR 4 • 2 • OPEN TO FOR GUARDRAIL DETAILS • •CONTINUOUS R-5 RIGID INSULATION AT INTERIOR FACE OF WALLS A6.22 ' HALL • Z fin \ - BEYOND EXTEND WATERPROOFING 0 .I • SE.• E INTERIOR DETAILS 24"MIN. ABOVE GRADE-TYP. H OPEN STEEL GUARDRAIL - - - • ; • • WITH PAINTED FINISH. FOR OPEN TREAD 0 AL UPPER LEVEL l _ _ ; STAIR DETAILS I FFE: 8328'-6" / .. • STAIR 1}.....) m CC • 1 I�1 • 41����4��������;; 201 • -oy 0 I 111 LANDING c �; BOULDER RETAINING H %00 ! •. - WALL. RE: CIVIL • ABOVE - ��% __--- 0 CI V • LINE OF WALL �� o 41 -- SLOPE GRADE AWAY FROM a Q BEYOND ���► I 41. BUILDING FOR POSITIVE W 4 > : ENTRY —— ��� �����0�0������������ 4< • DRAINAGE TYP. I 105 -- Ij = - W la STORAG • ' • — — - d� DOOR ROOM MAR FLEX DRAIN AND DRY BOARD AL LOWER LEVEL I -- - BEYOND 104 FFE: 8317'-6" - OVER WATERPROOFING AT2 • - I °.a FOUNDATION WALL TO GRADE-TYP. AL GARAGE LEVEL • a • FFE: 8317'-0" b. r.\ - - �O•� I FILTER FABRIC AROUND - - - - - - - - - •� • COURSE GRAVEL - - - - - - - - - - - - - - - • - EXISTING GRADE LINE CONCRETE SLAB ON GRADE ON AROUND 4" PERFORATED - - - - - - - - - - - - - - - 10 MIL POLYETHYLENE VAPOR FOUNDATION DRAIN PIPE DIFFUSION RETARDER ON 4 .1 2"RIGID INSULATION ON 4"GRAVEL I DRAIN TO DAYLIGHT-TYP. kr II • •. I . • . Ill . . . • .1 . . . I. • . . . I I L 1 ISSUED FOR: DATE: SCHEMATIC DESIGN 4.16.14 II TOV DRB FINAL REVIEW 6.9.14 • 1 ENTY CROSS SECTION I A4.23 SCALE: 1/4" 1'-0" GENERAL NOTES: •SPRING HEIGHT DIMENSIONS FROM FINISH FLOOR ELEVATIONS •SEE SPECS AND DETAILS FOR ADDITIONAL WATERPROOFING INFORMATION © 2014 MICHAEL SUMAN ARCHITECT,LLC. ALL RIGHTS RESERVED. SCALE: 1/4"= 1'-0" DRAWN: PROJECT#: 1401 SHEET TITLE: SECTIONS A4.23