Loading...
HomeMy WebLinkAboutDRB140248_001-236200 - Condensing Unit - BCER REVIEW_1403706240.pdf Technical Data Sheet for CU-1 Job Number: Y2Z08K Page Prepared Date: 5/19/2014 Job Name: CLINK Vail 2 of 11 www.DaikinApplied.com Job Information Technical Data Sheet Job Name CLINK Vail Date 5/19/2014 Submitted By James Murphy Software Version 03.30 Unit Tag CU-1 Unit Overview Model Number Voltage V/Hz/Phase Total Refrigeration Effect Btu/hr Total Unit Power kW EER RCS045D 208/60/3 449802 49.3 9.1 Unit Model Number: RCS045D Type: Applied Approval: ETL - USA Refrigerant Type: No. of Refrigeration Circuits Refrigerant Weight R410A 2 24.4 lb Refrigerant Type: No. of Refrigeration Circuits Refrigerant Weight, CKT #1 Refrigerant Weight, CKT #2 R410A 2 12.6 13.0 Condensing Section Temperature Altitude Refrigeration Effect Power EER Suction Ambient 45.0 °F 95.0 °F 8120 ft 449802 Btu/hr 49.3 kW 9.1 Compressor Quantity Type Capacity Control Compressor Isolation 4 Scroll 4 steps Resilient Full Load Current: Circuit 1, Compressor 1 42.2 A Circuit 2, Compressor 2 42.2 A Circuit 1, Compressor 3 42.2 A Circuit 2, Compressor 4 42.2 A Condenser Coil Fans Fan Motors Type Number of Rows Fins per Inch Condenser Fan Type Quantity Full Load Current Aluminum tube micro channel 1 18 Quiet 4 3.40 A Sound Casing Radiated Sound Power (db) 63 Hz 125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz 8 kHz 0 86 80 83 85 82 75 71 Physical Dimensions and Weight Length Height Width Operating Weight 80.0 in 73.0 in 99.0 in 2570 lb Technical Data Sheet for CU-1 Job Number: Y2Z08K Page Prepared Date: 5/19/2014 Job Name: CLINK Vail 3 of 11 www.DaikinApplied.com Refrigeration Connections Connection Type Number of Connections Connection Size Suction Line 2 1.62 Liquid Line 2 .88 Hot Gas Bypass 2 .88 Refrigeration Connections Connection Type Number of Connections Connection Size Suction Line Ckt. 1 1 1.62 in Suction Line Ckt. 1 1 1.37 in Liquid Line 2 0.88 in Hot Gas Bypass 2 0.88 in Electrical Voltage MROPD Field Power Connection MCA SCCR Field Outlet Connection 208/60/3 V/Hz/Phase 225 A Single power block 195.7 A 10 kAIC 115V, 20 amp service Options Unit Isolation Valves Per Circuit: Refrigeration Service Valves Hot Gas Bypass: HGBP Tee (See Accessory Tab) Condenser Coil Options: Condenser with hail protection, vandal grd Electrical Wiring Options Sealtite conduit GFI Receptacle Field powered Unit Control Temperature Controls: No temp control, 115 V transformer Low Ambient Control: Fantrol, Low ambient control to 45 degrees Warranty Parts: Standard one year parts Compressor: Extended four year compressor, five year total Notes Accessories Mandatory Part Number Description 193330721 Hot gas bypass kit, one circuit 193330711 Liquid line kit, replace core filter drier RCS045D_Drawing for CU-1 Job Number: Y2Z08K Page Prepared Date: 5/19/2014 Job Name: CLINK Vail 7 of 11 www.DaikinApplied.com RCS045D_Drawing for CU-1 Product Drawing Unit Tag: CU-1 13600 Industrial Park Blvd. Minneapolis, MN 55441 www.DaikinApplied.com Software Version: 03.30 Product: Project Name: CLINK Vail Model: RCS045D Sales Office: Long Building Technologies Sales Engineer: May 19, 2014 Ver/Rev: Sheet 1 of 1 Scale: NTS Tolerance: +/-0.25” Dwg Units: in [mm] RCS Piping_Drawing for CU-1 Job Number: Y2Z08K Page Prepared Date: 5/19/2014 Job Name: CLINK Vail 9 of 11 www.DaikinApplied.com RCS Piping_Drawing for CU-1 Product Drawing Unit Tag: CU-1 13600 Industrial Park Blvd. Minneapolis, MN 55441 www.DaikinApplied.com Software Version: 03.30 Product: Project Name: CLINK Vail Model: RCS045D Sales Office: Long Building Technologies Sales Engineer: May 19, 2014 Ver/Rev: Sheet 1 of 1 Scale: NTS Tolerance: +/-0.25” Dwg Units: in [mm]